manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Air King
  6. •
  7. Humidifier
  8. •
  9. Air King 3LA79A Instructions for use

Air King 3LA79A Instructions for use

Rev. A 9/05 1 2084779
DIGITAL RECIRCULATING HUMIDIFIER
9 GALLON MODEL 3LA79A/9929A
READ AND SAVE THESE INSTRUCTIONS
OPERATING INSTRUCTIONS & PARTS MANUAL
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION
The AirKing 9 Gallon (34.1 liter) Humidifier features 3-Speed whisper
quiet operation. This unit is capable of humidifying up to 3200 sq. ft.
(355.6 sq. yards) and features a 7.5 ft. (2.3 m) 18/3 cord set.
SPECIFICATIONS
Motor....................................120V, 50/60 Hz
Blade diameter ....................9" (22.86 cm)
Speeds.................................3
Control .................................Rotary Switch
Approvals.............................UL/CUL Listed
MODEL
3LA79A/9929A
SPEED
HIGH MED LOW
RPM 1300 1100 900
Amps 0.590 0.500 0.450
Watts 62.8 58.8 49.8
dB A 61 59 53
NOTE: A few droplets of water may be present
in your Humidifier as a result of our quality
testing prior to packaging and shipment.
DO NOT pour water into Grill. DO NOT spill water on Control Panel.
Water should only be poured into the Unit using the Jug.
CAUTION:DO NOT fill unit
before assembling.
1. Remove Water Jug then,
Upper Housing from base
of unit.
(Figure 1)
2. Laybaseof unit onit’sside
so the bottom of the unit
is facing you.
3. Fully insert the four Castors into
the holes in the bottom of the unit.
(Figure 2)
4. Replace Upper Housing, then Wa-
ter Jug into unit.
ASSEMBLY
Figure 1
Base
Upper Housing
Water Jug
MODEL 3LA79A/9929A
TROUBLE PROBABLE CAUSE SOLUTION
Fan not working or • No power Make sure Unit is plugged in
Humidifier doesn’t Check that the Power Switch is On
turn on • Humidistat not set correctly Set Humidistat to higher humidity level
•Top of Humidifier not seated properly Make sure top is properly seated on Base
on Base (Unit is equipped with an
automatic shut off)
•Filter Holder not assembled properly Make sure Filter Holder is seated in place
or is missing (Unit is equipped with an
automatic shut off)
Water leaking • Base is overfilled Reduce water level in Base
•Filter is old and dirty Replace Filter
Foul odor • Filter needs to be replaced Replace Filter
•Base needs to be cleaned Follow Instructions in CLEANING section
•Whole Humidifier needs cleaning Follow Instructions in CLEANING section
Filter discoloration • Mineral deposits in water Replace Filter
Water discoloration • Humidifier needs to be cleaned Follow Instructions in CLEANING section
•Hard water - Iron in water Use filtered or distilled water
•Some humidifier additives can cause
discoloration
Lights do not work:
Humidistat Light Off, • Humidity is not yet achieved in room Allow Humidifier to continue running
Power Light On
Power Light Off, • Room has reached desired Set Humidity Knob for more Humidity
Humidistat Light On Humidity level
No water show • No water in Unit Refill Unit
•Hose not connected to Pump Connect Hose to Pump
•Hose not connected to Water Show Connect Hose to Water Show
TROUBLE SHOOTING GUIDE
Figure 2
Hole
Castor
Rev. A 9/05 4 2084779
1 2010598 Humidifier Top 1
2 02091220I Screw #8 x 1/2 PPH Type 30A ZP 15
3 02030008EG Motor/Control Box Assembly 1
4 2010588 Chassis 1
5 2010590 Drip Shield 1
6 2010591EG Base 1
7 2010592 Front Filter Holder 1
8 2010593 Rear Filter Holder 1
9 02010860S Lever 1
10 02010861 Spring 1
11 02010862 O-Ring 1
12 02010871 Plunger 1
13 2010844 Jug 1
14 2010597 Jug Top 1
15 2010596 Jug Lid 1
16 02010868S Water Distribution Block 1
17 02010869S Water Show Assembly 1
18 2010870 Filter 1
19 2011073 Blade 1
20 2011074 Basket 1
21 2069093 Tube 1/4” x 24 1/2” 1
22 2069094 Tube 1/4” x 15 1/2” 1
23 02091221I Screw #8 X 3/4” PTH Type 30A ZP 7
24 02098038 Castors 4
25 02010601 Handle 1
26 02010867S Impellor 1
27 02010866LS Lower Pump Housing 1
28 02010866US Upper Pump Housing 1
KEY PART NO. DESCRIPTION QTY. 12
3
4
16
21
2
5
6
19
2023
322
17
28
26
27
25
14
13
12
11
15
10
9
7
8
18
24
GENERAL SAFETY INFORMATION
1. Makecertainthatthepowersourceconformstotheelectricalrequire-
ments of the Humidifier.
2. The power cord is equipped with a three-prong grounded plug that
must be inserted into a matching receptacle. Under no circum-
stancesmustthegrounding prong be cut offtheplug. Whereatwo-
prong wall receptacle is encountered, it must be replaced with a
properly grounded three-prong receptacle installed in accordance
with the National Electrical Code (NEC) and all applicable local
codes and ordinances. This work must be done only by a qualified
electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER
IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE
THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS ARE
NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT
REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY
SUPPLIED PLUG. IFTHE FAN DOES NOT FUNCTION PROPERLY,IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS
PLUG. RETURNTO AN AUTHORIZED SERVICE CENTER OR CALL
800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 AM AND 5:00 PM
EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED,
CALLTHETOLL FREE NUMBER FOR A REPLACEMENT LABEL.
3. Where possible, avoid the use of extension cords. If they must be
used, minimize the risk of overheating by ensuring that they are UL
listedand ofthepropergageandlength. Neveruseasingleextension
cord to operate more than one Humidifier.
4. Donotinsert fingers or foreignobjects into the Humidifier. Donotblock
ortamper with the Humidifier inany manner while it is in operation. Do
not touch the Humidifier while in operation or just after it has been
turned off, as some parts may be hot enough to cause injury.
5. Unplug power cord before filling or servicing the Humidifier.
WARNING: DONOTDEPENDUPONTHEON-OFFSWITCHASTHESOLE
MEANS OF DISCONNECTING POWER WHEN FILLING OR SERVICING
THE HUMIDIFIER. ALWAYS UNPLUG THE POWER CORD.
6. This Humidifier is intended for general use ONLY. It must NOT be
used in potentially dangerous locations such as flammable, explo-
sive, chemical-laden or wet atmospheres.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT USE THIS HUMIDIFIER WITH ANY SOLID STATE SPEED
CONTROL DEVICE.
7. Always place the Humidifier is on a stable, flat, level surface when
operating, to avoid the chance of the Humidifier overturning. Locate
the Power Cord so the Humidifier or other objects are not resting on it.
Keep the Power Cord away from room traffic.
8. Alwaysdirect air flow away from walls and furniture.Excessive moisture
may cause damage.
9. Completely reassemble Humidifier, according to instructions, before
reconnecting to power supply.
10. Humidifiers require regular cleaning to maintain proper operating condi-
tions. Refer to the CLEANING section for proper cleaning procedures.
Rev. A 9/05 3 2084779Rev. A 9/05 2 2084779
MODEL 3LA79A/9929A
CAUTION: Do not pour water through the
Exhaust Grill on the Upper Housing. Doing
so may cause damage and personal injury.
CAUTION: •Unplug Unit when filling.
•Always place Humidifier on a firm level surface.
Locate the Power Cord so the Humidifier is
not resting on it, and is away from traffic.
•Be careful not to overfill.
•Do not pour water through Exhaust Grill,
doing so may cause damage and personal injury.
•Take extra care to prevent water spillage
that may damage furniture or flooring. The
manufacturer will not accept responsibility for
damage to property caused by water spillage.
•Always be sure the Power Knob is in the OFF
position when plugging Humidifier into a
grounded 120 volt AC wall outlet.
•To prevent risk of electrical shock and injury to
persons, do not plug Humidifier into electrical
outlet with wet hands.
1. Itisrecommended that allHumidifiers be cleanedprior to use.Please
read Cleaning Instructions for Base and Jug cleaning.
2. Use the convenient Carrying Handle found on the bottom of the
Water Jug to bring it to a faucet.The Water Jug features a‘Quick
Fill/QuickEmpty’Spout.Tofill, hold Jugupside down bythe Handle.
Use thumb to press down Stopper Lever, and fill Jug. Fill theWater
Jug with cool tap water.Never use hot water.
(Figure 3)
When the Jug is replaced back into the Base it will quickly
empty to fill Base.
NOTE:While carrying filled Water Jug back to the Humidifier, hold
the Handle with one hand, while supporting bottom of Water Jug
with other hand.
3. Place the Water Jug securely in the Base. If positioned
properly, water will quickly pour into Base and automatically stop
when reaching desired amount.
4. When gurgling noise stops lift up the Water Jug to see if it is
empty. Refill if empty. When the Unit is full, some water will re-
main in the Jug.
5. Even though your Humidifier will produce approximately 9.0
gallons in a 24 hour period*, the water capacity (amount of water
the Humidifier will hold at one time) is 4.5 gallons.
(3 FULL Jugs).
Figure 3
Water Capacity of Unit is 4.5 Gallons
Carry Handle
Stopper Lever
Quick Fill /
Quick Empty
Spout
(Jug Holds 1-1/2 Gallons)
(Base Holds 3 Gallons)
The presence of water flow in theWater ShowWindow indicates
the circulation of water to the Filter.
(Figure 4)
OPERATION
1. Turn fan speed knob to desired speed.
-For fast humidification of a large room or house,
approximately 9 gallon per day.*
-For normal operation.
-For quiet, night time operation or after desired moisture
level is reached.
* Calculations based on ambient room conditions of 70°F
and 30% relative humidity in a room of average insulation.
The correct room humidity display will set itself 10 seconds after
the power cord is plugged into a 120 V outlet.
2. Push the humidity set button up or down, to adjust the
humidity to the desired level. The desired humidity range is
25% to 95%.
The desired humidity level is displayed in small numbers and the
correct room humidity % is displayed in large numbers.
Oncethecurrentroom humiditylevelreachesthedesiredhumid-
ity level, the fan will turn off and the humidity indicator light will
comeon. Thislight indicates thatthehumidifier is stillon and will
again start when the current room humidity level falls below the
desired set level.
If the current room humidity drops below 25% or goes above
95%, the display will blink off and on until the current room
humidity is within the 30% to 90% range.
▼
▲
1
2
3
0
1
54
3
2
Figure 5
1. Fan Speed Knob
2. Humidity Set Button
3. Desired Humidity %
4. Current Room Humidity %
5.
Humidity Indicator Light
- Light comes on when desired humidity
level is the same or lower than current
room humidity while the speed knob is
in the on position.
Figure 4
3
2
1
OFF-SEASON STORAGE
1. Clean and dry Humidifier thoroughly per the CLEANING
sectionabove.Do not leaveany waterin the Unit when storing.
2. Dispose of the Evaporative Filter Pad. Do not store used
Evaporative Filter Pad in the Humidifier.
3. Place Humidifier back into its carton and store in a cool
dry place.
FILTER CARE
The Filter inside your Humidifier plays a very important part in its
operation. In order to maintain peak performance, it is highly
recommended to use only AIRKING REPLACEMENT FILTERS.
Some imitation filters do not comply with AirKing’s quality standards,
resulting in decreased performance of your Humidifier.
CAUTION: To prevent electric shock, always turn Power
Control Knob to OFF position and unplug before servicing.
1. To replace the Evaporative Filter Pad, remove the Jug and Upper
Housing from the Base. Be careful not to let excess water
from pump spill onto furniture or flooring.
2. Remove Evaporative Filter Pad Holder from Base and inspect
Small Water Drip Holes for any blockage.
(Figure 6)
3. To open the Filter Holder apply outward pressure to the two
snaps and it will hinge open. Remove used Filter from Holder
and discard.
(Figure 7)
4. Insert new Filter into Holder, snap closed, and reinstall Holder
into Base.
(Figure 7)
The Filter will only fit into the Holder one
way. Make sure the Rounded side of the Filter Holder is facing
outward. Replace Upper Housing, then Water Jug into Base.
5. To increase the life of your Filter Pad turn
Filter around (so the bottom of Filter is
now at the top).
6. Filter life may be extended by cleaning
the Filter in a 20% vinegar solution. To
clean Filter, mix one part undiluted vin-
egar with four parts warm tap water. Soak the Filter in this
solution for 20 minutes, rinse Filter thoroughly with warm wa-
ter to remove vinegar odor.
DO NOT FLATTEN, SQUEEZE ORTWIST FILTER WHEN CLEANING.
7. Discoloration of the Evaporative Pad is normal after
extended use.The discoloration is caused by mineral deposits
in the water, and the degree of discoloration will vary depending
upon the amount of mineral content in the water.When the Fil-
ter surface area is thoroughly discolored, or you notice
reduced water usage, it is a good indicator that the Filter Pad
needs to be replaced. The Evaporative Pad should be
replaced at least once every season.
CLEANING
1. Regular cleaning is necessary to ensure proper and
efficient operation.The frequency of cleaning depends on
the amount of impurities which may be found in the water
or how often the Humidifier is in operation. In either in-
stance, it is recommended that the Humidifier be
cleaned at least once a week.
NOTE: Unscrew bottom of Water
Jug for easy cleaning.
(Figure 8)
CAUTION: Make sure bottom of
Jug is securely fastened to Jug
before reinstalling into Base.
2. TO DESCALE BASE, JUG
AND DRIP SHIELD: Mix one
part undiluted white vinegar
with four parts warm tap wa-
ter. Let vinegar solution
stand for 20 minutes then
wipe away any scale buildup
using a soft brush or cloth.
Do not use soap or deter-
gents and never use an
abrasive cleaner.
3. TO DISINFECT BASE, JUG
AND DRIP SHIELD: Fill Jug with 1 teaspoon of chlorine bleach
and 1 gallon of water. Let solution stand for 20 minutes.Carefully
empty Jug and rinse well with water until bleach smell is gone.
4. Commercial"Descalers" and "Bacteriostats"areavailableatyour
local home improvement center.
5. Do not operate Humidifier when there is still cleaner in the water.
Figure 6
Filter Pad Holder
Base
Drip Holes
MODEL 3LA79A/9929A
Figure 7
Snaps
Evaporative Filter Pad
Model 9930
Figure 8
Na
t
u
r
a
l
Ca
sc
a

This manual suits for next models

1

Other Air King Humidifier manuals

Air King AK4500 User manual

Air King

Air King AK4500 User manual

Air King 7000 EC Operating instructions

Air King

Air King 7000 EC Operating instructions

Air King 6000 Manual

Air King

Air King 6000 Manual

Air King 5000 Manual

Air King

Air King 5000 Manual

Air King 6000 User manual

Air King

Air King 6000 User manual

Air King AK4500 Manual

Air King

Air King AK4500 Manual

Air King 7000 User manual

Air King

Air King 7000 User manual

Air King Model 5000 Operating instructions

Air King

Air King Model 5000 Operating instructions

Air King AK5000 Operating instructions

Air King

Air King AK5000 Operating instructions

Air King 5000 User manual

Air King

Air King 5000 User manual

Air King AK7000 Operating instructions

Air King

Air King AK7000 Operating instructions

Air King 3LA80A Service manual

Air King

Air King 3LA80A Service manual

Popular Humidifier manuals by other brands

Crane TOP FILL EE-6913 instructions

Crane

Crane TOP FILL EE-6913 instructions

Fedders Herrmidifier Mister 50 user guide

Fedders

Fedders Herrmidifier Mister 50 user guide

DREVAL 7 STAGE user manual

DREVAL

DREVAL 7 STAGE user manual

Levoit LUH-D301S-WUK user manual

Levoit

Levoit LUH-D301S-WUK user manual

Anden AS35 quick start guide

Anden

Anden AS35 quick start guide

Honeywell HCM 890 - 2 Gallon Cool Moisture Humidifier owner's manual

Honeywell

Honeywell HCM 890 - 2 Gallon Cool Moisture Humidifier owner's manual

Pego EASYSTEAM installation manual

Pego

Pego EASYSTEAM installation manual

Aprilaire 400 Series Instructions and installation instructions

Aprilaire

Aprilaire 400 Series Instructions and installation instructions

Xiaomi CJJSQ01ZM manual

Xiaomi

Xiaomi CJJSQ01ZM manual

Honeywell Home HE400 installation guide

Honeywell Home

Honeywell Home HE400 installation guide

Crane EE-5202 instructions

Crane

Crane EE-5202 instructions

e-Ware XJ-5K128 Instructions for use

e-Ware

e-Ware XJ-5K128 Instructions for use

Philips HU4814/10 user manual

Philips

Philips HU4814/10 user manual

Vornado Evaporative Humidifier owner's guide

Vornado

Vornado Evaporative Humidifier owner's guide

Honeywell HEV320 Series instruction manual

Honeywell

Honeywell HEV320 Series instruction manual

Tommee Tippee Nursery humidifier Guide

Tommee Tippee

Tommee Tippee Nursery humidifier Guide

Apex Digital 9S-006500 user manual

Apex Digital

Apex Digital 9S-006500 user manual

HygroMatik DG8 quick start guide

HygroMatik

HygroMatik DG8 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.