AJAX Systems HomeSiren User manual

HomeSiren User Manual
Posted on October 6, 2021
HomeSiren is a wireless home siren with the capacity up to 105 dB. Developed only
for indoor use. It can be quickly installed and set up, is furnished with a LED (plus
allows connecting an external LED), and can operate up to 5 years from a battery.
HomeSiren operates within the Ajax security system, by connecting via the
protected protocol to the . The communication range is up to 2,000
meters if there are no obstacles.
The siren is set up via a for iOS and Android-based
smartphones. The user is notied of all events through push notications, SMS
messages and calls (if activated).
Operates only with . Connection to and integration
modules is not provided.
Jeweller hub
mobile application
Ajax hubs ocBridge Plus uartBridge

The Ajax security system is self-sustaining, but the user can connect it to the
central monitoring station of a private security company.
Functional elements
Operating Principle
The siren signicantly improves the eciency of the security system, being the
most operational means of response to the intrusion into a room. With a high
probability, its alarm signal will be sucient to frighten away the intruders.
Buy home siren HomeSiren
1. Light indicator
2. Siren buzzer covered with a fabric
3. SmartBracket attachment panel (perforated part is required for actuating the
tamper in case of any attempt to tear off the siren from the surface)
4. QR code
5. Tamper button
6. Socket for connecting an outside-mounted light indicator
7. On/off button

from far. Subject to correct installation, it would be hard to dismount and
deactivate the actuated siren: the body is rm, the power supply is autonomous,
and the on/off button will be blocked when the security system is set in the guard
mode.
Connecting the Siren to the hub
The HomeSiren siren operates only with the Ajax security system. Up to 10 sirens may be
connected to the Ajax hub
Before starting connection:
Only users with administrative privileges can add the device to the hub
How to connect the siren to the hub:
1. Following the hub instruction recommendations, install the on
your smartphone. Create an account, add the hub to the application, and create
at least one room.
Ajax application
2. Go to the Ajax application.
3. Switch on the hub and check the internet connection (via Ethernet cable and/or
GSM network).
4. Ensure that the hub is disarmed and does not start updates by checking its
status in the mobile application.
1. Select the Add Device option in the Ajax application.
2. Name the device, scan/write manually the QR Code (located on the body and
packaging), and select the location room.

For the detection and interfacing to occur, the siren should be located within the
coverage area of the wireless network of the hub (at a single protected object).If
the device was already assigned to another hub, switch off HomeSiren and then
perform the standard adding procedure.
Request for connection to the hub is transmitted for a short time at the time of
switching on the device.
If the connection to the Ajax hub failed, the siren will switch off after 6 seconds.
You may repeat the connection attempt then. To retry the connection, you do not
need to turn off the device.
The siren connected to the hub will appear in the list of devices of the hub in the
3. Select Add — the countdown will begin.
4. Switch on the device (by pressing on/off button for 3 seconds).

States
Siren states can be found in the Ajax app:
Parameter Value
Temperature
Temperature of the device. Measured on the
processor and changes gradually. Displayed in
1°C increment.
Acceptable error between the value in the app and
temperature at the installation site: 2–4°C
Jeweller Signal Strength
Signal strength between the hub/range extender
and siren.
We recommend installing the siren in places with
the signal strength of 2-3 bars
Connection
Connection status between the hub/range
extender and siren:
Battery Charge
Battery level of the device. Two states available:
1. Go to the Devices tab.
2. Select HomeSiren from the list.
• Online — the siren is connected to the
hub/range extender
• Oine — the siren is not connected to the
hub/range extender
•
• Battery discharged
How battery charge is displayed in

the detachment of or damage to the body
Alarm Volume
Volume level in case of alarm
The volume level is measured 1 m away from the
siren
Alarm Duration, sec Duration of the alarm sound: from 3 to 180
seconds
LED indication
LED indication of the siren settings:
Beep When Arming/Disarming
If active, the siren noties you about the
activation and deactivation the system of the
guard mode by the LED and a short sound signal
Notify about switching the Night mode on/off
When enabled, the siren noties you when the
system is on and off the Night mode by ashing
the LED and making a short beep
Beep on Entry/Exit delay If activated, siren will beep delays (available in
devices with rmware version 3.50 and later)
Notify about the entry/exit delay in the Night
If this option is enabled, the siren beeps to signal
• Muted — the siren does not sound when the
alarm is raised
• Quiet — 81 dB volume
• Loud — 93 dB volume
• Very loud — 105 dB volume
• Disabled— LED indication is off
• Armed — the siren blinks only when alarm is
enabled
• Always — the siren blinks regardless of the
state of the security system
More about indication

Temporary Deactivation
Shows the status of the device: active, completely
disabled by the user, or only notications about
triggering of the device tamper button are
disabled
Firmware Detector rmware version
Device ID Device identier
Device No. Number of the device loop (zone)
Setting Up the Detector
To change the HomeSiren settings in the Ajax app:
Setting Value
First eld
Siren name that can be edited. The name of
device you can see at notications in the event
feed.
The name can contain up to 12 Cyrillic characters
or up to 24 Latin symbols
Selecting the virtual room to which StreetSiren
What is chime
1. Select the hub if you have several of them or if you are using the PRO app.
2. Go to the Devices tab.
3. Select HomeSiren in the list.
4. Go to Settings by clicking on the .
5. Set the required parameters.
6. Click Back to save the new settings.

Alarms in Group Mode
Regardless of the group selected, the siren will
respond to activation and alarms
Alarm Volume
Volume level in case of alarm:
The volume level is measured 1 m away from the
siren
Alarm Duration, sec
The setting determines how long the siren
sounds, if the alarm is activated (from 3 to 180
seconds per each actuation)
LED indication
LED indication of the siren settings:
indication are related to alarms and events of
this group
• When attached to all groups, the siren and its
indication are related to alarms and events of
all groups in the system
Night Mode
Learn more
• Muted — the siren does not sound when the
alarm is raised
• Quiet — 81 dB volume
• Loud — 93 dB volume
• Very loud — 105 dB volume
• Disabled— LED indication is off
• Armed — LED blinks once every 2 seconds
only when the system is armed
• Constantly — LED blinks once every 2 seconds
regardless of the mode state

Volume Test
Jeweller Signal Strength Test
Switching the siren to the Jeweller signal strength
test mode. The test allows you to check the signal
level between the hub and HomeSiren and
determine the optimal installation location
Signal Attenuation Test
Switches the siren to the signal fade test mode
(available in devices with rmware version 3.50
and later)
User Guide Opens the HomeSiren User Manual
Temporary Deactivation
Allows the user to disconnect the device without
removing it from the system.
Two options are available:
What is Volume Level Test
What is Jeweller Signal Strength Test
What is Attenuation Test
• No — the device operates normally and
transmits all events
• Entirely— the device will not execute system
commands or participate in automation
scenarios, and the system will ignore device
alarms and other notications
• Lid only— the system will ignore only
notications about the triggering of the device
tamper button
Learn more about temporary
deactivation of devices

Arming/Disarming
When this option is enabled, the siren warns of
arming and disarming by lighting of the LED
frame and by a short beep
Night mode Activation/Deactivation
If enabled, the siren alerts you by backlighting the
LED frame and a short beep when arming and
disarming the system from the Night mode
Entry Delays
If this option is enabled, the siren beeps to signal
about an entry delay
Exit Delays
If this option is enabled, the siren beeps to signal
about an exit delay
Entry Delays in Night Mode
If this option is enabled, the siren beeps to signal
about an entry delay in the Night mode
Exit Delays in Night Mode
If this option is enabled, the siren beeps to signal
about an exit delay in the Night mode
When enabled, the siren beeps 1 to 4 times to
indicate that opening detectors in the Disarmed
What is Night mode
What is Delay When Entering/Leaving
What is Delay When Entering/Leaving
What is Night mode
What is Delay When Entering/Leaving
What is Night mode
What is Delay When Entering/Leaving

Beep volume
The volume level was measured 1 m away from
the siren
Setting up the processing of detector alarms
Through the Ajax app, you can congure which detector alarms can activate the
siren. This can help to avoid situations when the security system noties of
LeaksProtect detector alarm or any other device alarm. The parameter is adjusted
in the detector or device settings:
Setting the tamper alarm response
The siren can respond to the tamper alarm of devices and detectors. The option is
disabled by default. Note that the tamper reacts to the opening and closing of the
body even if the system is not armed!
• Quiet — 80 dB volume
• Loud — 93 dB volume
• Very loud — 98 dB volume
1. Sign in to the Ajax app.
2. Go to the Devices menu.
3. Select the detector or device.
4. Go to its settings and set the necessary parameters for activating the siren.

Setting the response to pressing the panic button in the Ajax
app
The siren can respond to pressing the panic button in Ajax apps. Note that the
panic button can be pressed even if the system is disarmed!
For the siren to respond to pressing the panic button:
Setting the siren after-alarm indication
5. Enable the Alert with a siren if the hub or detector lid is open option.
1. Go to the Devices menu.
2. Select the hub and go to its settings .
3. Select the Service menu.
4. Go to Siren Settings.
5. Enable the Alert with a siren if in-app panic button is pressed option.

The option functions as follows:
Thanks to this feature, system users and security companies patrols can
understand that the alarm has occurred.
The siren after-alarm indication does not work for always active detectors, if the detector
was triggered when the system was disarmed.
To enable the siren after-alarm indication, in :
1. Go to siren settings:
2. Specify what events the sirens will inform about by double blinking before the
security system is disarmed:
1. The system registers the alarm.
2. The siren plays an alarm (duration and volume depend on settings).
3. The siren LED and external LED (if connected) blinks twice (about once every 3
seconds) until the system is disarmed.
Ajax PRO app
• Hub→Settings →Service →Siren Settings
• Conrmed alarm
• Unconrmed alarm

How to set Chime
Chime is a sound signal that indicates the triggering of the opening detectors when
the system is disarmed. The feature is used, for example, in stores, to notify
employees that someone has entered the building.
Notications are congured in two stages: setting up sirens and setting up opening
detectors.
HomeSiren with rmware 5.55.1.0 and later supports this function.
Siren settings
Learn more about Chime
1. Go to the Devices menu.
2. Select the siren.
3. Go to its settings by clicking the gear icon in the upper right corner.
4. Go to the Beeps Settings menu.
5. Scroll down and enable the Chime on opening option in the Beep when
disarmed
category.

Detectors settings
7. Click Back to save the settings.
8. Repeat steps 2–7 for other sirens on which you want to enable the
notications.
1. Go to the Devices menu.
2. Select the detector.
3. Go to its settings by clicking the gear icon in the upper right corner.
4. Go to the Chime Settings menu.
5. Select the events to be notied by the siren:
• If a door or a window is open.
• If an external contact is open (available if the External Contact option is
enabled).
6. Select the chime sound (siren tone): 1 to 4 short beeps. Once selected, the Ajax
app will play the sound.
7. Click Back to save the settings.
8. Repeat steps 2–7 for other detectors on which you need to enable the
notications.

settings
Switching on the device LED lights up once
Switching off the device LED will light up for 1 second, then blink three
times
Registration failed LED lights up and goes out, then the siren
switches off
Security system set in the armed mode
(if the indication is activated)
Blinks once with a LED and emits a short sound
signal
Security system is disarmed
(if the indication is activated)
Blinks twice with a LED and emits two short
sound signals
Siren in the armed mode
(if the indication is activated) LED lights up for a short time every 3 seconds
Battery low
LED smoothly lights up and goes out when the
system is armed or disarmed (if the indication is
activated), the tamper is actuated or alarm is
given
Performance testing
The Ajax security system allows conducting tests for checking the functionality of
connected devices.
The tests do not start straight away but within a period of 36 seconds when using

transmission: walls, inserted oors, large-size objects located within the room.
The device developed only for indoor use.
Check the signal level at the installation location.
The communication range is up to 2000 meters if there are no obstacles. Please
consider it when choosing an installation place for HomeSiren.
If the signal level is one division, we cannot guarantee stable operation of the
security system. Take possible measures to improve the quality of the signal! As a
minimum, move the device — even 20 cm shift can signicantly improve the quality
of reception.
If, after moving, the device still has a low or unstable signal strength, use a
.
Recommended installation height — 2.5 meters and more. This will complicate the
access to the device for intruders in case of intrusion.
ReX
radio signal range extender

If the light indicator of the siren is not actuated after installation in SmartBracket,
check the tamper mode in the Ajax Security System application and then the xing
tightness of the device on the panel.
In case of any attempt to dismount the siren, you will receive the notication.
Do not install the siren:
The double-sided adhesive tape may be only used for temporary attachment of the
siren. The tape will run dry in course of time, which may result in the falling and
damage of the device.
2. Put the siren on the SmartBracket panel and turn it clockwise. When installing
in the attachment panel, the tamper will switch and the siren will blink with a
LED.
1. outside the premises (outdoors)
2. in places where the acoustic signal will be attenuated (inside furniture, behind
thick curtains, etc.)

polarity during the connection. Black terminal wire — “+” contact.
Outlet power supply:3 V, 10 mA.
Siren Maintenance and Battery Replacement
Check the operational capability of the HomeSiren on a regular basis.
Clean the siren body from dust, spider web and other contaminations as they
appear. Use soft dry napkin suitable for equipment maintenance.
Do not use for cleaning the siren any substances containing alcohol, acetone,
gasoline and other active solvents.
The batteries installed in the siren ensure up to 5 years of autonomous operation
(with the inquiry frequency by the hub of 1 minute) or at least 6 hours of the buzzer
sound. If the battery is discharged, the security system will send respective notices
and the LED will smoothly light up and goes out when the armed mode is activated.
How long Ajax devices operate on batteries, and what affects this
Battery Replacement

Radio signal modulation GFSK
Radio signal range Up to 2,000 m (any obstacles absent)
Battery supply 2 × CR123A, 3 V
Battery life Up to 5 years
Socket for connecting
an external light indicator Yes (power supply 3 V, 10 mA)
Body protection level IP50
Installation method Indoors
Operating temperature range From -10°to +40°
Operating humidity Up to 75%
Overall dimensions 75 × 76 × 27 mm
Weight 97 g
Other manuals for HomeSiren
1
Table of contents
Popular Security System manuals by other brands

Eminent
Eminent EM8610 user manual

aquilar
aquilar AquiTron AT-ZAP Installation & operation

Honeywell Home
Honeywell Home Ademco Vista Series quick guide

C & K Systems
C & K Systems Sierra user manual

Leitronic AG
Leitronic AG EasyAlarm BASIC User instructions

Response
Response SA1 E Installation & operating manual

Bentel
Bentel LADY-FPI manual

Nice
Nice HSSOC Instructions and installation for use

American Bus Video
American Bus Video FHD4W quick start guide

Videofied
Videofied SE651 Product installation sheet

Cooper Security
Cooper Security i-on16 Installation and programming guide

Studio Technologies
Studio Technologies Annoucer's Console 233 user guide