Alde Compact 3030 User manual

Operating instructions Alde Compact 3030/3030 Plus
Alde Compact
3030, 3030 Plus
1 zone/2 zone
Certified for use in recreational vehicles
© Alde. All Rights Reserved.


3
Alde Compact 3030, 3030PLUS 1 zone/2 zone
Alde Compact
3030
Alde Compact
3030PLUS
Operating instructions Alde Compact 3030/3030 Plus 30
© Alde. All Rights Reserved
This material may not be distributed to 3rd parties without approval from Alde International Systems AB
Alde Compact 3030
Alde Compact 3030 Plus
Alde Compact 3030, 3030 Plus, 1 zone, 2 zone

30
User safety information
Your safety and that of others is of the utmost importance. Always read and follow all safety instructions
carefully.
All safety information in the manual is marked with this symbol.
All safety instructions are indicated by the safety symbol with the word
“DANGER”, “WARNING”, “CAUTION” or “NOTICE”.
An imminently dangerous situation
that will result in death or serious personal injury.
A potentially dangerous situation
which may result in death or serious injury and/or damage to property.
A potentially dangerous situation
that can lead to minor or moderate injury.
Requires attention to follow
WARNING
NOTICE
CAUTION
DANGER
WARNING
Risk of re or explosion
•
•
• Always use original parts from Alde.
•
• Only use LPG.
Carbon monoxide poisoning
•
if not correctly installed and/or used correctly.
•
•
• Never use the system without adequate ventilation.
•
• Never allow water to enter the system when cleaning the vehicle. If using a high pressure washer
DANGER
Safety warnings

31
GB
WARNING
Hot water
The heating system can supply water at a temperature above 85°C.
•
•
•
How long can the skin be exposed to hot water?
Temperature °C Time before skin injuries occur
70 Extreme danger! < 1 second
66 Very dangerous! 1-5 seconds
60 Danger! < 10 seconds
54 < 30 seconds
52 Warning! 2 minutes
49 5–10 minutes
38 Safe Safe bathing temperature
Source: Moritz, A.R./Herriques, F.C.: Studies of thermal injuries: the relative importance of time and surface
temperature in causation of Cutaneous burns A. J. Pathol 1947; 23: 695–720.
• Before using the hot water tap or shower, let the water run until the temperature is safe and
stabilised.
•
• Never allow a child or a disabled person to bathe unattended.
water conditions and length of pipe to the heating system.
• Damage to the heating system may void your warranty.
•
prevent the boiler from freezing. The warranty does not cover damage caused by freezing.
CAUTION
NOTICE
WARNING
WARNING

32
Table of contents
1. Intended use 33
2. Safety devices 33
3. Important information 34
3.1 Use of the heating system 34
3.2 Winter and sub-zero temperatures 34
3.5 Convection 35
4. Initial operation of the heating system 36
4.2 Using the water heater 37
5. Starting the heating system for the rst time 38
6. Review of Alde Control Panel 40
6.2 Status screen 40
6.3 Set the desired temperature 41
6.4 Hot water 41
6.5 Energy sources 42
6.6 Settings menu 42
7. How your smart Alde Compact 3030/3030 Plus works 44
8. Care and maintenance 45
8.1 Replacing of the air cushion 45
8.2 Emptying water heaters and water pipes 45
8.4 Bleeding the heating system 47
9. Error messages 48
9.1 If a fault persists 49
9.2 Operating messages 49
10. Troubleshooting 50
11. Service menu & resetting 51
12. Technical description of the heating system 52
12.1 Operation on LPG 53
12.2 Operation on electricity 53
13. Warranty 54
14. Health Declaration 290
15. Declaration of Conformity 292
16. Software licence 294

33
GB
1. Intended use
The Alde Compact 3030/3030 Plus heating system is intended for heating of recreational vehicles,
Alde Compact 3030/3030 Plus heating systems each consist of a gas/electric boiler and convectors.
gas and/or electricity in the boiler.
panels in recreational vehicles.
Installation and repairs must only be performed by an Alde Service Partner.
The product is only for use in recreational vehicles.
2. Safety instructions
Flame monitor
Low current shut-off
Exhaust fan monitor
Monitoring boiler temperature
WARNING
Always read and follow these instructions before installing and/or using the system.

34
3. Important information
3.1. Use of the heating system
•
•
3.2 Winter and sub-zero temperatures
•
must not be used while travelling.
The fresh water in the heater must always be drained in case of frost or if the vehicle is not in use,
freezing.
WARNING
Asphyxiation hazard
WARNING
Risk of re or explosion
•
•
• Always use original parts from Alde.
•
• Only use LPG.
WARNING
•
• When the vehicle is not in use.
• Depending on national legislation, the LPG main tap shall be closed while the vehicle is in service.
WARNING

35
GB
3.3 The Glycol uid in the heating system
•
•
•
normal use.
•
information on aeration of the heating system, see section 8.4 Bleeding of the heating system.
3.4. External factors that may aect the heating system
•
stainless steel systems. Rinse the system thoroughly before using the heating system again.
•
deposits that may cause impaired function and rust formation.
•
soot formation.
3.5 Convection
Fig. 1. Convection
Alde Compact Boiler 3030/3030 Plus
Hot surfaces
CAUTION

36
4. Initial operation of the heating system
4.1. Pre-operation check of the heating system
•
system is properly ventilated before putting it into use.
•
air at the chimney.
•
follow the safety instructions.
CAUTION
Fig. 2. Expansion vessel
Fluid level in a
cold system

37
GB
4.2. Using the water heater
The Alde Compact 3030/3030 Plus heating system has a built-in hot water heater.
The water heater can also be used without heat circulating in the vehicle. Set the desired room
automatically.
Procedure:
connected to water.
period, open any hot water tap in the vehicle and allow around 12 litres run out through the tap.
3. Close all taps and start the heating system.
WARNING
Scalding hazard
Remember, the water in the water heater may be very hot.
Freezing risk
-
freezing.
WARNING
WARNING
Avoid using the Boost and Autoboost functions in your Alde Compact 3030 Plus when the water
heater is empty. The water heater must always be full of water when using Autoboost.
CAUTION

38
5. Starting the heating system for the rst time
2. Select language.
pressing the
option arrives.
mode.
The relevant accessory is highlighted if connected:
Pump, 12 V pump. Select Manual if there
is a selector on the pump, otherwise
PWM.
DuoControl, Bottle Switch.
Booster fan.
-
Alde AquaClear UV-C.
Engine pre-heat. Heat the engine using
the Alde heating system.
for increased hot water capacity and
-
5.
Single-zone system
• To change the desired indoor temperature from the status screen, press the menu button multiple times
Raise or lower the temperature using the plus and minus buttons.
Fig. 3. single zone Fig. 4. single zone
1

39
GB
Dual zone system
installed in the zone.
zone whose temperature has changed.
• Activate the other accessories/functions installed via their respective menus.
• To change the indoor temperature from the status screen, press the respective zone icons, e.g. "Liv-
6. Set the time and day by touching the time icon top right of the status screen.
Regardless of the energy choice, the boiler will not use more energy than it needs, so select the
highest setting possible.
Fig. 6. dual zone Fig. 7. dual zone
Fig. 5. dual zone

40
6. Review of Alde Control Panel
6.1. Switching the boiler on and o
6.2 Status screen
When the control panel is in sleep mode, the status screen is shown. Press the relevant status screen
icon to reach its sub menu. Press the button to reach the settings menu.
Icon description for the status screen’s top row (Figs.9a, b)
not an error. Await. Read more in section 9.2 Operating messages.
Information. Flashes when there is an information message.
Day Mode. Shows when the function is activated, and turns green when it is
automatically switched on.
Night Mode. Shows when the function is activated, and turns green when it is
switched on automatically later .
switched on.
it is automatically switched on.
High altitude mode. Flashes if high altitude mode is activated.
Fig. 9a.
Status screen,
single-zone system
Fig. 9b.
Status screen,
single-zone system
Fig. 8. Control Panel
LED out
2. System starting,
LED lit
NOTICE
but will come on again when the screen is touched. Read more under section 6.6. Settings menu.
Footnote. Features marked with star (*) are accessories.

41
GB
Icon description for the status screen’s main menu (Figs. 10a, b)
Single zone system. Indoor temperature. Displays the current temperature and
temperature.
Dual zone system. Zone icons. Displays the current temperature and whether
desired temperature.
meter is fully coloured-in when hot water reaches boost temperature. Press the
section 6.4 Hot water.
temperature is displayed.
6.3 Set the desired temperature
The temperature can be set from +5°C to +30°C in increments of 0.5°C.
For 1 zone, set the temperature by pressing directly on the plus and minus
buttons.
For 2 zones, press the icon for the zone you wish to set the temperature in.
To leave the menu, tap the menu button.
6.4 Hot water
The boiler has a built-in hot water heater with a volume of around 10 litres.
The boiler can be used even without fresh water being in the heater.
• -
ment in the vehicle.
• On - Hot water switched on.
• Boost - Priority hot water production. The boiler will now prioritise the produc-
tion of hot water for 30 minutes. When 30 minutes have passed, the boiler
returns to its previous setting.
Prioritised hot water production is recommended for increased hot water demand.
• Auto - Hot water switched on and goes automatically to Boost as required.
Auto is only available in 3030 Plus.
Fig. 10a.
Main menus on
the status screen,
single-zone system
Fig. 11. Set
temperature
Fig. 12a.
Set hot
water production,
Alde Compact 3030
WARNING
Scalding hazard
requirement.
Fig. 10b.
Main menus on
the status screen,
dual-zone system
Fig. 12b.
Set hot
water production,
Alde Compact 3030 Plus

42
6.5 Energy sources
The boiler can be powered either by gas or electricity, or both at the same time. When the boiler
approaches the set temperature, energy consumption is gradually reduced. Press Energy to reach
Warming up with electricity
Warming up with gas
Priority
It is also possible to prioritise the energy source. When both gas and electricity are switched on, select
Load monitor*
The boiler and Truma AC connected to the Alde system will automatically reduce their consumption
when e.g. a toaster or hairdryer is switched on.
High altitude mode
Only use high-altitude mode if the boiler will be run on LPG at altitudes above 1000 metres amsl.
For high-altitude LPG operation, use propane to ensure stable combustion. Varied operating
conditions at high altitudes may cause the boiler to not always reach full gas operation.
6.6 Settings menu
To reach the Settings menu from the sleep/standby screen, press the button.
Settings menu, Fig. 14
Night Mode. Automatically changes select features during the night. Choose
Day Mode. Automatically changes select features throughout the day. Choose the
should follow.
Fig. 13. Choice of energy sources
Fig. 14.
Settings menu
Footnote. Features marked with star (*) are accessories.

43
GB
Settings menu, Fig. 14
Settings menu, Fig. 15
Pump in constant operation.
when it is cold. Automatic switch-on requires an outdoor sensor to be installed.
Delayed start, automatic boiler start.
230 V. The function is used to start the boiler by connecting 230 V to the vehicle.
but 12 V connected. Some vehicles may be equipped with their own solution
adjusted ± 5 °C if you feel the temperature sensor needs adjusting. Also applies
to outdoor temperature sensor.
Settings menu, Fig. 16
You can also choose whether the status screen should be Normal, Inverted, or
again if touched.
-
-
uously and describe the current status of the boiler. See section 11 Service
Menu & Reset.
Reset. Resets the panel to factory setting. The accessories/features selected
Fig. 15.
Settings menu
Fig. 16.
Settings menu

44
7. How your smart Alde Compact 3030/3030 Plus works
installed dual-zone system is required to control the temperature in two zones.
Alde’s intelligent climate technology
-
temperature. This is to avoid unnecessary energy being consumed and to ensure that the prioritised
-
ty and gas. The boiler never uses more power than necessary.
-
tures which give you the ability to increase comfort by automating changes in temperature and turning
If you also have an AC from Truma installed and connected with your Alde system, and an outdoor
technology. The AC is then controlled from the same sensor as your Alde Heating System and can be
controlled by the same smart Alde technology. If your Truma AC also has a heating function, this also
accordance with national regulations and by a trained professional.
CAUTION
NOTICE

45
GB
8. Care and maintenance
tester, installed as closely to the reduction valve as possible.
•
•
8.1 Replacement of the air cushion
The heating system is designed to have air space, a so-called air cushion, at the top of the hot water
in the heating system.
Always replace the air cushion in the heating system after 10 days of use. Do this by opening the
8.2. Emptying of water heaters and water pipes
2.Open all water taps to the central position so that both hot and cold water run out.
-
used again.
5.Reset all safety/drain valves by closing the handle again and pressing in the blue button on the side.
WARNING
NOTICE
Scalding hazard
Remember, the water in the water heater may be hot.
Fig. 17. Safety valve / drain valve
2. Button for
closing
1. Knob for
emptying Knob for
emptying
Fig. 18. Safety valve / drain valve

46
8.3 Glycol uid
of normal use.
8.3.1 Rell the heating system with Glycol uid
-
CAUTION
NOTICE
bacterial growth and/or overheating.
NOTICE
WARNING
Poisoning
Fig.19. Expansion vessel
Fluid level in
cold system
Other manuals for Compact 3030
2
This manual suits for next models
1
Table of contents
Popular Water System manuals by other brands

UseTECH
UseTECH FlowTimer+ Detect V2 operating instructions

Little Giant
Little Giant WCR Series owner's manual

BIO-MICROBICS
BIO-MICROBICS MicroFAST 0.5 Service manual

Prochem
Prochem EVEREST 650 operating instructions

Little Giant
Little Giant WCR Series installation instructions

Greenlife
Greenlife hybrid manager Installation and operation manual

Pure-Pro
Pure-Pro RO101 user manual

Ocmis Irrigazione
Ocmis Irrigazione AQUA SYSTEM 3 Instruction manual for use and maintenance

Zip
Zip HydroTap G4 installation instructions

Borg
Borg Oasis Studio Kenko Moebius 55 Operation manual

Krausen
Krausen 800 STABLE Installation and user manual

Simer
Simer 2806E owner's manual