Alien green Mostat Guide

Instructions for Installation v1.0

Read the instructions attentively before starting installation of the thermostat, as the booklet contains important
information about safety guidance and normative rules regarding the thermostat and its installation.
Keep the User Safety Guidance for further usage, if needed.
The thermostat must be set up according to current installation standards
Before starting the work, make sure the boiler is NOT supplied with voltage power
USER SAFETY GUIDANCE
01
NOTE: The pictures of the printed circuit board of the boiler in the User Safety Guidance give a general idea of
its looks while an actual printed circuit board may differ schematically in products of the various manufacturers.
!
Read all warnings with great attention!

IN THE BOX
Temperature and Humidity
Transmitter (Room Sensor)
Process Control Block (PCB)
Outside Antenna
Antenna Connector
2x AA Batteries
Power Cable
2-strand Wire
2x Bolts
02
2x Cable Ties

Process control block (PCB)
is installed in the central heating boiler
DEVICE DESCRIPTION
03
Wi-Fi router is connected to the Internet, and
provides the connection between the devices
(NOT applied to the complexion)
The temperature and humidity transmitting sensor
can be installed in the office, or private residence

Setting up the process control block (PCB) in the central heating boiler
CAUTION: Before starting the work, please make sure that the boiler is NOT supplied with voltage power!
Unpack the (PCB).process control block
Open the boiler so that you can reach the printed circuit board.
(If necessary, use the instructions for the boiler).
INSTALLATION
!
04

1. Drill a hole in the casing to set up the antenna there,
as shown on the picture.
2. Connect one end of the antenna connector to the
process control block (PCB).
3. Fix another end of the antenna connector in the hole,
and wrap it around the bolt.
4. Screw the antenna to the casing, as shown on the picture.
2
3
4Green
Lights
AP Status
Status
Red Light of
Power Indicator
Green Light of
Boiler Indicator
Button
7 mm
1
05

TA1
6. Connect one end of the power cable
to the process control block (PCB),
and another end of the power cable
to the printed circuit board, as shown
on the picture.
Make sure that everything is connected
according to the instructions, and switch
on the central heating boiler. If the power
cable is connected to the process control
block (PCB), the red light appears
while the green light of is blinking.Status
2-strand Wire Power Cable
Printed Circuit Board
5. Find the connector for the room thermostat with the number TA1 (if you have a boiler by Ariston),
or TA,LS-LR,COM-NO (if you have a boiler by any other manufacturer but Ariston). Disconnect the connector
on TA1, and connect the 2-strand wire, as shown on the picture.
06
5
6
Green Lights
of Status
Red Light of
Power Indicator

FUNCTIONAL TESTING
Push the button on the process control block (PCB) once and wait till the green light appears on the boiler. If the
connector (TA1) of process control block (PCB) is connected properly, the boiler flame will appear within 10 seconds.
The flame will fade when the button on the process control block (PCB) is pushed again. If the boiler flame did not
appear, swap the strands of TA1 wire, and repeat the procedure.
Button
Green Light
of Boiler
07

Online activation of the thermostat is necessary for receiving the full service. For online activation, please open
the thermostat application on your mobile phone, or go on the web page from your https://app.aliangreen.ge
computer, and register yourself as a user.
Open application in the mobile phone, and push the button.MOSTAT Configuration
Using Wi-Fi of your mobile phone, connect to Mostat device named . MOSTAT-[Serial number of your device]
If asked for a password, type in capital letters: , and follow the application instructions.MOSTAT123
The application will connect the devices to your home Internet.
QR-CODE can also be used for
downloading the application
ONLINE ACTIVATION OF THE THERMOSTAT AND ITS LINKAGE
TO THE PERSONAL ACCOUNT
08

DESCRIPTION OF PROCESS CONTROL BLOCK (PCB)
The red light of power indicator is on when the process control block (PCB) is supplied with voltage power.
The green light of is blinking when the factory reset, i.e. configuration option is active.Status
The green light of is blinking when the device is connecting to Wi-Fi router.AP-Status
The green light of is on when the process control block (PCB) is active.Status
The green light of is on when the process control block (PCB) is connected to the Wi-Fi router.AP-Status
The green light of boiler indicator is ON when the heating is ON.
The green light of boiler indicator is OFF when the heating is OFF. TA1
Green
Lights
AP Status
Status
Red Light
of Power Indicator
Green Light
of Boiler Indicator
Button
09

SETTING UP THE ROOM SENSOR
It is recommended to set up the room sensor in the area of private residence where the
family members spend most of their time.
The distance between the floor and the device must be 120-150 cm.
The device must be 200-300 cm away from the door and windows.
Avoid the sunlight.
TIP: These recommendations are given for avoiding the measurement errors of temperature
!
mostat
120-150 cm
200-300 cm 200-300 cm
10

CONFIGURATIONS OF THE ROOM SENSOR
Take the room sensor out of the box, and move its lid off.
Remove the pull to start tab for activating the battery, as shown on the picture.
Take the room sensor to the central heating boiler, and push the button once;
When the button is pushed, the blue light starts blinking, which means the device
is ready for configuration option.
At this moment push the button on process control block (PCB) in
the central heating boiler once so that the light starts blinking.Status
During this activity the configuration parameters are exchanged
between the process control block (PCB) and the room sensor.
After the configuration is successfully completed, the green light
will blink three times on the room sensor. If the configuration is
successfully complete, push the button again.
RUN RST
Button
Light
If the configuration is NOT successfully complete, push again the
button on the process control block (PCB) and the room sensor.
CAUTION: While replacing the battery, press the PCB with a finger of one
hand and use another hand to carefully take the battery out, without damaging the device.
!
11
!
Use only Lithium FR6 or Alkaline LR6 batteries, preferably, Energizer or Duracell.
!

When the room sensor is all set up, make sure that and lights on process AP-Status Status
control block (PCB) are permanently ON, without blinking.
Only when and lights are permanently ON, close the central heating boiler and switch it on.AP-Status Status
A GUIDE TO OCCATIONAL PROBLEMS AND HOW TO SOLVE THEM
AP-Status light is blinking: This signals that the process control block (PCB) cannot connect to your home
Wi-Fi router. In this case, the process control block (PCB) must be restored to its factory state.
Hold down the button on process controlHow to Perform a Factory Reset on the Process Control Block (PCB):
block (PCB) for 10 seconds until the and lights start blinking fast. Then let the button go – and AP-Status Status
this way the device will be factory reset. Open the application on your mobile phone, choose “ ”Configuration
and follow the instructions on your phone.
Hold down the room sensor button for 10 seconds until How to Perform a Factory Reset on the Room Sensor:
the red light starts. Let the button go – and the blue light will start blinking. This way the device will be factory reset.
Open the application on your mobile phone, choose “ ” and follow the instructions on your phone.Configuration
In case of resetting the password, the process control block (PCB)How to Reset Password on Wi-Fi Router:
must be .factory reset
12

TECHNICAL SPECIFICATIONS
Room Sensor (83.5 mm x 26.5 mm)
Process Control Block (PCB) (82 mm x 53 mm)
Wireless Internet (Wi-Fi 802.11b/g/n @ 2.4GHz, 5GHz 802.15.4 @ 2.4GH)
Room Sensor and Process Control Block (PCB) are connected to each other by means of Wi-Fi Unlike to other
thermostats, this one does not need an additional router because both modules use the home wireless Internet
Temperature Sensor (-40ºC to +120ºC)
Temperature Feeling (+/-0.01ºC)
Humidity Sensor (0 up to 100% RH)
Humidity Feeling (+/-0.04% RH)
Room Sensor (2x AA battaries; will run for a year)
Process Control Block (PCB) (Supplied with power from the central heating boiler)
Wi-Fi Internet connection is mandatory
Compatible to 90% of the central heating boilers used in Georgia
Thermostat is controlled through applications iOS, Android, Web (Safari, Chrome, Firefox). Communication to the
room sensor is held only through the application. Control is possible from several devices at the same time.
2-year
13
Dimensions:
Communication:
Sensors:
Power Supply:
Compatibility:
Application:
Warranty:

+995 32 2424622
https://aliengreen.ge/ka/thermostat/faq
https://aliengreen.ge/ka/contact-us
https://www.instagram.com/mostatge/
https://www.facebook.com/mostatge
http://twitter.com/mostatge
Whether you need a technical support, or simple advices,
Feel free to contact us.
Sincerely,
Alien Green team
14
Table of contents
Popular Thermostat manuals by other brands

Tecnocontrol
Tecnocontrol Easy 503 PROGRAMMING INSTRUCTIONS AND INSTALLATION GUIDE

Prostat
Prostat PRS6420 Installer manual

MCOHome
MCOHome MH7H-WH user manual

EasyHeat
EasyHeat Warm Tiles FGS Operating & installation instructions

Environmental Technologies
Environmental Technologies SST-2 Installation and operation manual

Silvercrest
Silvercrest RT2000 operating manual

Comfort Zone
Comfort Zone 8259 Programming guide

Krom Schroder
Krom Schroder T20 Instructions for installation, use and maintenance

Tecnocontrol
Tecnocontrol geca Nota 503 Quick user guide

Pro 1 IAQ
Pro 1 IAQ T705 operating manual

Pro 1 IAQ
Pro 1 IAQ R751WO Operation manual

Timeguard
Timeguard TRT034 Operating & installation instructions