AlkaViva Athena H2 User manual

Owner's Manual
!Athena!H
Warning:(Incorrect(installation(and/or(operation(could(void(your(valuable(warranty.(
Please(protect(your(investment!(READ(THIS(MANUAL(CAREFULLY.
Alkaline Water Ionizer and Hydrogen Generator
Only from AlkaViva
2

Congratulations on Your New Purchase ...................................................
Let’s Take a Tour of Your Athena H
2
.............................................................
Installation Procedure .......................................................................................
Operating Your Ionizer .....................................................................................
Ionizer Performance Factors ..........................................................................
Using Ionized Water ..........................................................................................
How To Replace the Filter ...............................................................................
Using the Cleaning Filters ...............................................................................
Troubleshooting Guide ..................................................................................
TABLE(OF(CONTENTS(
04
06
08
11
14
15
18
20
21
03
Important Safety Warnings and Precautions ...........................................
2
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Manually Adjusting the Power .......................................................................
13

Congratulations,on,Your,New,Purchase
You have just purchased the nest, most advanced alkaline water ionizer and hydrogen generator in the world! Your new
Athena H
2
is designed to provide you with many years of the cleanest, healthiest and most functional water available. There
are many specic uses and benets of this amazing water, so read this manual carefully to learn how to install, maintain, get
optimum performance out of your ionizer and to protect the investment you’ve made.
Your new Athena H
2
produces ltered alkaline, ionized, and hydrogen-rich water. Just exactly what is that? Your ionizer
employs computer accurate and selectable magnetic energy to perform electrolysis through platinum titanium electrodes
inside a water cell. Inside this advanced cell, the magnetic energy separates the water into an alkaline (high pH) and acid
(low pH) stream and enriches the water with dissolved molecular hydrogen (H
2
) without using any chemicals. Ionizing the
water also binds extra oxygen molecules, and concentrates ionized, absorbable and benecial minerals like calcium,
magnesium and potassium.
Your new Athena H
2
also produces acidic water. This type of water has a low pH (less than pH 6) and has many excellent uses.
You will now have the convenience and benets of water that functions in many ways that ordinary tap, ltered or bottled
water cannot.
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
3

Electrical Precautions and Safeguards
NEVER attempt to repair or service the unit yourself. Attempting to do so will void your valuable warranty! Contact
AlkaViva Customer Service to arrange service or repair.
If your ionizer becomes submerged in water, unplug the power cord from the wall before removing the ionizer from the water.
Failure to do so may cause electric shock!
NEVER touch the power cord or plug with wet hands - this may result in electric shock!
Do not wash your ionizer by immersion or by pouring water over the main body; always unplug your ionizer while cleaning the
casing. Clean with damp sponge or cloth.
Ensure the power plug is rmly and properly inserted into the outlet - failure to do so may result in electric shock or re!
Keep the power cord and your ionizer away from hot surfaces or appliances - failure to do so may result in electric shock or re!
Do not operate your ionizer with a damaged power cord or plug or insert into a faulty or worn outlet.
Never insert foreign objects into your ionizer.
Do not use your ionizer at voltages other than specied (AC 110-120V FOR USA). Use a grounded outlet. Do not plug in your ionizer
where it will exceed the rating of the outlet or electrical wiring. Failure to do so can result in re, injury and/or damage to your
wiring, your ionizer, or yourself!
Important Safety Warnings and Precautions
This appliance must be grounded. In the event of a malfunction or breakdown, ground will reduce the risk of electric
shock by providing a path of least resistance for electrical current. This appliance is equipped with a cord having an
appliance grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is
installed and grounded in accordance with all local codes and ordinances.
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Always unplug your ionizer when changing a fuse or cleaning your ionizer. Failure to do so may result in an electric shock!
1
4

Let’s Take A Tour of Your NEW Athena H
2
Front View Rear View
Bottom View
Tap Water Inlet
Diverter
Hose(1/4”) Acidic Water Outlet
Back Panel
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Covers the back of the ionizer.
Control Panel Function controls and display. Detailed on next page.
Flexible Stainless Steel Spout Outlet for either alkaline or acidic water (user-selected).
Front Panel Covers the front of the ionizer.
Filter Cover Remove this panel to change lters.
Bottom Panel Covers bottom of the ionizer.
Acidic Water Outlet For acidic water. Labeled with red sticker.
Water Inlet Tap water supply. Labeled with black sticker.
Key-hole Slots For wall mounting.
Fuse Holder Fuse.
Audio Speaker Transmits voice and melody.
Audio Volume Control Volume control.
Flow Control Valve On/Oand water ow adjustment.
Locking Device Filter cover safety lock. Depress when removing lter cover.
2
Description
Name
#
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
3
4
2
6
13
5 5
9
6
4
1
8
7
12
11
10
14
14
9
5

6
Control Panel
Acidic Water
Indicator
Illuminates when
acidic water is
selected.
Filtered Water
Indicator
Illuminates when
ltered water is
selected.
Alkaline Water
Indicator
Illuminates when
alkaline water is
selected.
Filter Life Indicator
1st and 2nd lter
indication.
Water Flow Indicator
High
H range illuminates to
indicate maximal ow.
(Lower performance.)
Normal
Alkaline Water
Selection Buttons
Low
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Normal range illuminates to
indicate optimal ow.
(Normal performance.)
L range illuminates to
indicate low ow.
(Best performance - water
may taste unpalatable.)
Error Code Indicator
Shows error codes for
trouble shooting with
AlkaViva Customer Service.
Select Alkaline Water.
(Alkaline 1,2,3,4 and
Alkaline 5)
Filtered Water
Selection Button
Select Filtered Water only.
Acidic Water
Selection Buttons
Select Acidic Water.
(Acidic 1, Acidic 2)

7
Protect your ionizer from freezing temperatures.
Protect your ionizer from direct sunlight.
Do not put anything heavy on top of your ionizer.
Do not install your ionizer on an unstable or soft surface.
Install only on a hard and level surface.
Installation Precautions
Installation Procedure
3
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Do not install close to a stove.
Install close to a properly grounded electrical outlet. Do not close, bend, pinch, press or otherwise
obstruct hoses.
If you have installation questions, please call AlkaViva Customer Service.
Installation Options
Install Method 1: At your sink attached to your faucet with the diverter,
Install Method 2: At your sink but plumbed directly to your cold water line (no diverter) and,
Install Method 3: Undersink - completely out of sight with a small dedicated faucet.
It is recommended that Methods 2 and 3 be done by a plumber.
Make Sure You Have All the Accessories
Before installation, please check to ensure you have the accessories pictured below.
Please note that the diverter and adapters accommodate the vast majority of standard faucets. The angle-stop adapter ts both
1/2” and 3/8” standard plumbing. If you have a non-standard or a custom faucet, or plumbing, you may need to locate and
purchase additional parts. If you need help, please contact AlkaViva Customer Service.
Complete Installation Package Angle Stop Adapter pH Test Reagent
In-line Sediment Filter
The sediment iter is an optional accessory that will further protect your ionizer and lengthen the life of your lters. It is
installed in the 1/4” white tap water inlet hose before it enters your ionizer in any of the three installation methods. It can
be opened and cleaned as needed.
Calcium & Scale Guard
Inserts - 1 of each
NOTE

8
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Install Method 1: At the sink with a diverter (easiest)
1. ATTACH DIVERTER TO YOUR TAP - Remove the aerator from tap
(pliers may be required) and attach diverter valve in its place. There are
adapters supplied in case the diverter does not t your tap. If you have
leaks at the diverter, use plumber's Teon tape (included).
2. ATTACH THE 1/4” WHITE TAP WATER INLET HOSE (Fig. 1) - Attach the
white 1/4” hose to the white port on the bottom of the ionizer labeled
TAP WATER INLET. To attach the white hose, simply push it rmly into
the opening on white port. Give it a gentle tug to ensure proper connection.
If it is properly installed, it will not come out. If you need to remove it, press
on the ring at the end of the tting while pulling out.
Tools You May Need:
t4UBOEBSEQMJFSTPSDIBOOFMMPDLT
t"TIBSQLOJGFPSBHPPEQBJSPGLJUDIFOTDJTTPST
3. ATTACH THE GRAY ACIDIC WATER OUTLET HOSE (Fig. 2) - Attach
the gray hose to the white plastic port labeled ACIDIC WATER OUTLET on
the bottom of the ionizer. First, slide a squeeze clamp over the end of the
hose. Attach the gray hose by simply pushing it rmly over the white plastic
port. Soaking it in water for 30 seconds will make attaching it very easy.
Squeeze the clamp and position it over the white port. Ensure the opposite
end runs into the sink.
4. POSITION YOUR IONIZER - Ensure it is on a hard and level surface.
See installation precautions.
5. ATTACH THE 1/4” WHITE HOSE TO THE DIVERTER (Fig. 3) - Measure the
appropriate length of white hose, allowing for a reasonable amount of slack,
and cut using sharp knife or scissors. Remove the small compression nut on
the back of the diverter (opposite of the lever). Slide the nut over the
opposite (free) end of the white 1/4” hose with the threads positioned so it
will screw onto the diverter. Push the hose rmly onto the nipple, then screw
the compression nut back on. Ensure the nut is tightened rmly. Do not over
tighten.
6. CONNECT THE POWER CORD - Use an appropriate grounded outlet.
7. INSTALL FLEXIBLE STAINLESS STEEL SPOUT - Screw the spout clockwise
into the threaded silver port on top of the ionizer. Do not over tighten.
8. SAVE THE BOX
your ionizer came packed in. This will help if your ionizer
needs to be transported at a lat
er date.
1/4" White Hose to Tap Water Inlet Port
Gray Hose To Acidic Water Outlet Port
Attach 1/4” White Hose to Diverter
Fig. 3
Fig. 2
Fig. 1
Fig. 3

9
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Install Method 2. At the sink, direct plumb (more dicult/convenient/attractive)
. 2. ATTACH THE WHITE 1/4” TAP WATER INLET HOSE TO THE ANGLE STOP ADAPTER (Fig. 1)
Attach the white 1/4” hose to the adapter by simply pushing rmly into the white port. Give a
gentle tug to ensure proper connection. It should not come out. You will need a way to route the
white hose from the adapter to your ionizer. Most newer sinks have cutouts that will work for this.
If not, drill a 1/4” hole.
3. ATTACH THE WHITE 1/4” TAP WATER INLET HOSE TO YOUR IONIZER (Fig. 2)
Attach opposite (free end) of the white 1/4” hose to the white TAP WATER INLET port on the
bottom of the ionizer. To attach the white hose, simply push it rmly into the TAP WATER INLET
port. Give it a gentle tug to ensure proper connection. It should not come out. To remove it,
press on the end of the tting and pull it out at the same time.
-
Undersink installations can only be accomplished with an AlkaViva Undersink Conversion kit. Othe shelf parts will not work. Your
ionizer will require a very specialized faucet and a variety ofother parts. The Conversion Kit comes with everything needed including
instructions to complete this type ofinstallation. It is recommended that a plumber perform this type of installation. Please contact
AlkaViva Customer Service for details.
4. ATTACH THE GRAY ACIDIC WATER OUTLET HOSE (Fig. 3) - Attach
the gray hose to the white plastic port labeled ACIDIC WATER OUTLET on
the bottom of the ionizer. First, slide a squeeze clamp over the end of the
hose. Attach the gray hose by simply pushing it rmly over the white plastic
port. Soaking it in water for 30 seconds will make attaching it very easy.
Squeeze the clamp and position it over the white port. Ensure the opposite
end runs into the sink.
5. POSITION YOUR IONIZER - Ensure it is on a hard and level surface.
See installation precautions.
6. CONNECT THE POWER CORD - Use an appropriate grounded outlet.
7. INSTALL FLEXIBLE STAINLESS STEEL SPOUT - Screw the spout clockwise
into the threaded silver port on top of the ionizer. Do not over tighten.
8. SAVE THE BOX
your ionizer came packed in. This will help if your ionizer
needs to be transported at a lat
er date.
Gray Hose To Acidic Water Outlet Port
1/4" White Hose to Tap Water Inlet Port
Attach 1/4” white
hose to angle stop
adapter
Fig. 1
Fig. 2
Fig. 3
Install Method 3. Undersink with conversion kit (most dicult)
1. INSTALL ANGLE STOP ADAPTER (included) to COLD WATER SUPPLY LINE
Locate the cold water line. Shut othe cold water supply. Unscrew the exible supply line from the angle stop. Attach the adapter.
(Fits standard 1/2 and 3/8” plumbing.) Make sure adapter is in “open” position (blue knob parallel to the length of the body of the adapter).
Leave angel stop closed. (water shut o) (Fig 1)
Tools You May Need:
t8SFODI
t1MJFST
t%SJMMXJUIPSCJU

ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Operating Your Ionizer
Operating Precautions
4
Your ionizer is not under warranty for any damage caused by hard water.
If the appliance makes strange or unusual noises or odors are detected, unplug the power cord immediately and contact AlkaViva
Customer Service to arrange service.
Unplug your ionizer if you plan not to use it for an extended period. FIlter replacement may be necessary when you use it again.
Store your lter in a plastic bag inside of your refrigerator to prevent bacterial growth.
Do not use an ionizer downstream of any ion exchange water soft
ening system or
reverse osmosis system without rst consulting
AlkaViva Customer Service
.
Do not use benzene, paint thinner or insecticidal sprays for cleaning your ionizer. Doing so can damage the nish.
Do not run hot water through your ionizer. Doing so will damage your lters.
Do not clean by spraying or pouring water over the ionizer. Clean using warm soapy water and a sponge or clean rag.
Do not close, bend, pinch, press or otherwise obstruct output ports or hoses.
10
DO NOT use your ionizer with well water, water with extreme hardness, high sediment or TDS levels without rst contacting
AlkaViva Customer Service.
Make sure to use your ionizer only with potable water which is suitable for human consumption.

11
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
For Installation Method #1 - at the sink with a diverter:
1. OPEN THE FLOW CONTROL VALVE
- This control is on the front of the machine
and has an ON and OFF position. Try initially setting this half way between
ON and OFF
Important : This is one of the most critical features in controlling your ionizer's
performance. This control WILL DIRECTLY impact the performance of your ionizer.
A slow ow will yield higher performance; a fast ow will yield lower performance.
2. TURN ON YOUR COLD WATER FAUCET - Turn the diverter lever until the water runs
through your ionizer.
3. NOTICE THE DIFFERENCE IN FLOW RATES by adjusting the FLOW CONTROL VALVE from
a slow trickle to the fastest ow. When you begin ionizing the water, start with it in the
normal range for optimal results.
For Installation Method #2 - at the sink direct plumbed
1. TURN ON YOUR WATER SUPPLY LINE AT THE ANGLE STOP - Ensure the angle stop adapter is in the open position. (The blue knob parallel
to the length of the adapter body.)
2.
OPEN THE FLOW CONTROL VALVE
- This control is on the front of machine and has an ON and OFF position. When ionizing
water initially try opening the valve half way between ON and OFF.
3. NOTICE THE DIFFERENCE IN FLOW RATES by adjusting FLOW CONTROL VALVE from a slow trickle to the fastest ow. When you
begin making hydrogen-infused ionized water, start with it in the normal range for optimal results.
WHAT YOU WILL NOTICE:
t5IFDPOUSPMQBOFMXJMMJMMVNJOBUFBOEXBUFSTIPVMEøPXGSPNCPUIIPTFT
t5IF%JHJUBM'JMUFS-JGF*OEJDBUPSXJMMCFHJOUPSFHJTUFSOVNCFSTBOEZPVXJMMIFBSZPVSJPOJ[FShTWPJDFBOOPVODJOHUIFNPEFPGPQFSBUJPO
'PSJOTUBODF1VSJöFEXBUFSTFMFDUFE
NOTE: The water will initially come out discolored (light to charcoal gray) due to carbon dust in the new lter. This is not harmful and is
typical of all carbon lters. Allow the water to ow for 2-3 minutes in the PURIFIED mode until it runs clear.
1. Start the Water Flow Through Your Ionizer
Important : This is one of the most critical features in controlling your ionizer's
performance. This control WILL DIRECTLY impact the performance of your ionizer.
A slow ow will yield higher performance; a fast ow will yield lower performance.

12
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
2. Selecting Alkaline Ionized Hydrogen-Infused Water
Control Panel Alkaline Level Buttons
What You Will See
In the Display
Water Flow Indicator
1. Open the Flow Control Valve to let the water ow in.
Your control panel will illuminate and the word ALKALINE
will show on the display. For optimal perfomance, set the
value so the ow is in the normal range on the display.
2. Use the ALK button to select the level. The level you have
selected will illuminate next to the ALK button and a
numerical approximation of the pH level will appear on
the display.
3. You will hear voice conrmation: “Alkaline Ionized Water
on process.”
4. To change alkaline levels, simply depress the button of the
alkaline level desired, ALK 1-5. ALK 1 is the weakest setting
and ALK 5 is the strongest.
5. Your Athena
H
2
will always“remember” the last setting
used. If you were using ALK 2, the next time you start your
ionizer it will automatically start on ALK 2.
When the tap water ows through your Athena
H
2
, the Water Flow Indicator illuminates: Lwhen the water pressure/ow rate is low and H
when it is high, NORMAL when it is normal. Your Athena
H
2
will produce optimal performance for drinking water (the perfect balance in pH,
-ORP,
H
2
and taste) when it is in the normal range.
3. Selecting Acidic Ionized Water
Acidic Level Buttons
t"DJEJDJPOJ[FEXBUFSJTOPUJOUFOEFEGPSSFHVMBSESJOLJOHXBUFS"DJEJDJPOJ[FEXBUFSIBTNBOZ
great uses. Learn more about this in the next section on using acidic water.
t5IF%"3$DMFBOJOHTZTUFNXJMMLFFQZPVSFMFDUSPEFTDMFBO3VOOJOHBDJEJDXBUFSUISPVHIZPVS
ionizer will keep the rest of the components of the machine clean. If you live in a hard water area
this should be done daily for 1-2 minutes.
1. Open the Flow Control Valve to let the water ow in. Your Control Panel will illuminate.
2. Use the ACID button to select the level. Your control panel will illuminate and the word ACID
will show on the display. For optimal perfomance, set the value so the ow is in the normal range
on the display.
3. You will hear voice conrmation: “Acidic Ionized Water on process.” You will also hear a melody
to alert you that acidic water is running.
4. To change acid levels, simply depress the button of the acidic level desired, ACID 1 or 2. ACID 1
is the weakest setting and ACID 2 is the strongest.
5. Your Athena
H
2
will always“remember” the last alkaline setting used. If you were using ACID 1,
the next time you start your ionizer it will revert to the last ALK 1-4 level you used.
When you select Alkaline water, it will ow through the
Flexible Stainless Spout at the top of your Athena
H
2
.
When you select Acidic water, it will ow through the Flexible Stainless Spout
at the top of your Athena
H
2
6. When the tap water ows through your Athena
H
2
, the Water Flow Indicator illuminates: Lwhen
the water pressure is low and H when it is high, NORMAL when it is normal.
Exception to the above: when ALK 5 (strong alkaline) is
selected, your Athena
H
2
will come on at the last ALK 1-4
level used the next time you use it.
NOTE:
This number will change
depending on the ALK
setting you have chosen.
What You Will See
In the Display
This number will change
depending on the ACID
setting you have chosen.

13
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
4. Selecting Puried Water
Puried water is only ltered, not ionized. When selected, it will ow through the Flexible
Stainless Spout at the top of your Athena
H
2
.
Puried Water Buttons
1. Open the Flow Control Valve to let the water ow in. NOTE: Your control panel will illuminate.
2. Use the PURIFIED button to select ltered water. On the control panel the word PURIFY will
illuminate and the letters“PU” will illuminate on the display panel.
3. You will hear voice conrmation: “Crystal clear water in production.”
4. Your Athena
H
2
will always“remember” the last alkaline setting used. If you were using
PURIFIED, the next time you start your ionizer it will revert to the last ALK 1-4 level you used.
When the tap water ows through your Athena
H
2
, the Water Flow Indicator illuminates:
Lwhen the water pressure is low and H when it is high, NORMAL when it is normal.
What You Will See
In the Display
PU will always appear.
While AutoAdjust automatically provides very ne real-time adjustments to the pulse width, you can also manually adjust the power to
best suit your unique water quality and desired performance requirements. By manually changing the power-steps for each Alkaline
and Acidic level, you can change the main power settings making bigger more impactful changes in performance. Here's how:
Step 1. Start water ow through your ionizer by turning on the Flow Control valve and/or Diverter.
Step 2. For this example, we will use ALK 5 level. You may manually set this for each ALK or ACID level. Select the ALK or ACID
level you’d like to adjust – just as you would for changing levels under normal operation.
Step 3. Press and hold the ALK 5 button until Display changes and looks like this:
5IFöSTUEJHJUNFBOTALK Level 5BOETFDPOEEJHJUNFBOTFMFDUSJDQPXFS
value 3. There are four electric power values available;
Power Level 1 is the lowest and Power Level 4 the highest. If you want to raise or lower the Power Value, press same button
(ALK Level 5). The second digit will change to reect the power level.
Step 4. 1SFTTQVSJGZUPTFUUIFWBMVF5IFOFYUUJNFZPVVTFUIFJPOJ[FSJUXJMMiSFNFNCFSwUIFMBTUNBOVBMMZTFMFDUFE1PXFS-FWFM
You must set each ALK and ACID level.
Step 5. For other levels, please repeat the steps above.
Manually Adjusting the Power
5

14
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
1. Fill a shot glass or other small, clean glass container with about 1 inch of alkaline, acidic or puried water.
2. Place 3 drops of the pH reagent into the vessel and gently shake or stir it. If the reagent and water are not mixed well, the correct result
may not be achieved. Too many or too few drops will aect results.
3. The pH value is determined by matching the color to the pH color chart provided.
4. Keep the pH reagent in a dark and cool place. DO NOT expose to sunlight or heat.
5. Be sure to rinse out the vessel thoroughly prior to each use or the pH level may be incorrect.
6. Do not drink the water that has been tested with the pH testing solution.
How to Measure pH
Very Important Information About Your Ionizer Performance
There are three primary factors that control the performance of your ionizer:
1) The quality of your source water and its mineral content. We cannot control this factor.
2) The voltage being applied to the water. You control this by selecting the ALK level or ACID level on the control panel. The
higher the setting the more voltage or power is being applied to the water.
3) The ow rate of water through your ionizer. You control this with the Flow Control knob on the control panel. This determines
how long the water is being processed. With a fast ow your ionizer will produce lower pH, with a slow ow it will produce
higher pH.
Water quality and mineral content vary greatly in dierent localities. Use the pH Test Kit and be sure to test your source water.
(FOFSBMMZJOIBSEXBUFSBSFBTXIFSFNJOFSBMDPOUFOUJTIJHIFSZPVSJPOJ[FSXJMMFBTJMZSFBDIIJHIMFWFMTPGQ)FWFOXJUIBGBTUFSøPX
*OTPGUXBUFSBSFBTXIFSFNJOFSBMDPOUFOUJTMPXFSZPVSJPOJ[FSNBZPOMZSFBDIUIFIJHIFSMFWFMTPGQ)XJUIBTMPXFSøPX*GZPVSTPVSDF
XBUFSUFTUTBUBWFSZMPXQ)ZPVNBZXBOUUPCPPTUQFSGPSNBODFCZBEEJOHBDBMDJVNDBSUSJEHFJOUPUIFDBMDJVNQPSUBUUIFUPQPGUIF
ionizer lter (see the next section).
Ionizer Performance Factors
6

ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Don't Develop a "Drinking" Problem!
If you have never consumed hydrogen-infused ionized water, do not use a setting higher than 1 to begin with. Let your body adjust
slowly and naturally for 2-3 days. After this initial adjustment period, gradually increase the alkalinity of the water by increasing the
setting you use.
Do not take medications with hydrogen-infused ionized water. Take medications only with puried water.
Consult with a physician before drinking hydrogen-infused ionized water if you are currently under medical treatment, have a chronic
disease, or have achlorhydria.
Consult a physician before using acidic water if you have sensitive skin or allergies.
Only use potable drinking water in your ionizer. Poor water quality may have negative eects on your health and your ionizer! Most
municipal water sources will be ne in your ionizer. Well water and water from smaller systems should be checked
and may require
pre-ltering.
.
Caution
Using Ionized Water
Do not use the following type of water
t"DJEJDXBUFS
t8BUFSESBJOFEBGUFSTFMGDMFBOJOH
t8BUFSUFTUFEXJUIUIFQ)SFBHFOU
Additional Cautions
t%POPUVTFUIFXBUFSJOBOBRVBSJVN
t*POJ[FEXBUFSMPTFTJUTFòFDUJWFOFTTJGTUPSFEGPSNPSFUIBOBEBZPSUXP
7
Ionized hydrogen-infused water is always best fresh out of the machine and
ideal
if consumed on a day-to-day basis.
Carry it with you in glass, ceramic or high quality BPA-free plastic bottles.
Always
keep your stored water cool and away
from direct sunlight to preserve optimal water quality.
NOTE
15

Various dishes
When cooking bamboo shoots, tree shoots, taro and seaweed with the alkaline water, the bitter
taste and the sour taste will be gone while the natural taste will be enriched. When using it as
the water for steaming sh, the shy smell will be eliminated and it will make the sh taste better.
Liquors and cocktails
When used as the water for mixing, liquor will taste softer and milder. Ditto when making a
cocktail using ice made from alkaline water.
Plants
If seeds are soaked in the alkaline water before being planted, the germination rate will be
enhanced. In case of stem cutting or grafting, they will take better.
Vegetables and fruits
Wash vegetables or fruits in alkaline water and they can be kept fresh for a longer period of time.
Vegetables with unpleasant odors
When cooked after being soaked in the alkaline water for about 20~30 minutes, odor will be
reduced, making vegetables softer and tastier.
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
Other Uses for Hydrogen-infused Alkaline Ionized Water (in addition to drinking)
Cooking rice
Try cooking rice after soaking the rice in the alkaline water for 30 ~ 60 minutes in advance.
When cooking rice with the alkaline water, the rice will be glossy, tasty, and it will store better for a
longer period of time.
Coee, black tea and herbal tea
Help remove the bitter taste of coee and the puckery taste of black tea as well as enriching
the faint taste and fragrance unique to black tea.
Heavy drinking and hangover
If you drink a 12-16 oz glass before going to bed or on an empty stomach in the morning you
will minimize the eect of a hangover.
16

Using Acidic Water
Skin Care
Acidic water can be a beauty solution good for your skin. It acts as an astringent and helps make the skin
soft and elastic. (Skin is mildly acidic.)
Hair Care
Use acidic water as a hair rinse after shampooing to neutralize the alkalinity of the shampoo, and help
retain the hair’s natural gloss.
Shaving
Use acidic water after shaving; it can replace skin toner or after shave.
Floral arrangement
Use acidic water for cut owers. It will keep the owers fresh for a longer period of time.
Boiling eggs
When the acidic ionized water is used for boiling eggs, the shell is less likely to crack while cooking
and the eggs will peel easily.
Water for parboiling noodles
When the acidic ionized water is used for parboiling noodles, it will make them chewy and tastier.
Washing or processing deep colored fruits and vegetables
Washing peaches, grapes, strawberries, red cabbages, beans and asparagus etc. with acidic water
will retain their natural colors and they will stay bright and vibrant.
When preparing fried dishes
Use acidic ionized water to prepare batter for fried dishes to make the foods crispy and tastier.
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
General cleaning
When the acidic ionized water is used for cleaning oors, dirt and grime can be easily removed
and it dries quickly.
Cleaning glass
When glass, mirrors and glasses are washed with acidic ionized water, dirt and grime is easily
removed and glass is shiny without streaks.
Encrusted pots and pans
Soak pots and pans in the acidic ionized water overnight to remove encrusted or burnt food.
Cleaning the cutting board or counters
Use acidic ionized water to naturally clean and sanitize your cutting board and counters.
Cleaning dishes and silverware
Use it for cleaning dishes and silverware. It will not leave spots.
1713

ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
How to Replace the Filter
Replace your lter when:
t8IFOUIFöMUFSMJGFJOEJDBUPSOVNCFSSFBDIFTBOEJUJTCMJOLJOH
t$POTJEFSJOHUIBUöMUFSMJGFTQBODBOEJòFSCBTFEPOXBUFSRVBMJUZJOJOEJWJEVBMBSFBTXF
recommend replacing the lter before the end of the life span is reached if the water smells
or the water ow volume decreases.
t8IFOZPVIBWFSVTUZXBUFSEVFUPBHFEQJQFT
t*GUIFSFJTBMPUPGTFEJNFOUPSJNQVSJUJFTJOUIFXBUFSGPSBTIPSUQFSJPEPGUJNF
t*GVTFEJOBQMBDFXIFSFUIFXBUFSQSFTTVSFJTWFSZMPX
8
1. Open Both Filter Covers (Fig. 1)
t1SFTTUIFXIJUFCVUUPOUPVOMPDLUIFDPWFS*UJTJOUIF
middle of the bottom of the cover.
t8JUIUIFDPWFSVOMPDLFEMJGUUIFDPWFSTUSBJHIUVQ
2. Remove Old Filters (Fig. 2)
t5XJTUUIFFYQJSFEöMUFSDPVOUFSDMPDLXJTFBOEMJGUPVU
3. Install New Filters (Fig. 3)
t3FNPWFUIFQSPUFDUJWFTUJDLFSPOUIFCBTFPGFBDIöMUFS
(Bottom as you read the label.)
t*OTFSUUIFPQFOJOHJOCBTFPGUIFOFXöMUFSPOUPUIFSBJTFE
lter base.
t5XJTUDMPDLXJTFVOUJMMPDLFE:PVTIPVME/05CFBCMFUPMJGU
it out. If the lter is not fully twisted, it could cause leaking.
18
Possible situations where lter life can be shortened drastically:
Fig. 1 Fig. 2 Fig. 3 Fig. 4
Fig. 5
4. Reset the Filter Life Indicator (Fig. 4)
t1VTIUIF'JMUFS3FTFU#VUUPO3FEPOUIFSJHIUBOEHSFFOPOUIFMFGU
t:PVXJMMIFBSPOF#&&1XIFOZPVQVTIJU
t)PMEJUEPXOVOUJMZPVIFBSBTFDPOE#&&15IFöMUFSDPVOUFSXJMM
reset. Release the button.
t3FQFBUPOUIFPUIFSTJEF
5. Close the cover. (Fig. 5)
t-JOFVQUIFWFSUJDBMFEHFTBOETMJEFEPXOVOUJMZPVGFFMIFBSUIF
cover lock.
Ensure that you install each lter in its proper place: Pre-lter goes
in the compartment on the right side; Second-Stage lter goes in
the compartment on the left side. This is noted on the lter label.
NOTE

ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
How to Add Scale Guard or Calcium Inserts
1. Ensure the water ow is o.
2. The inserts go into a port on the top of your lter. To access the lter, follow the
instructions in Section 7 - How to Relace The Filter.
3. Once you have the lter removed, unscrew the cap on the top of the lter body.
If you have previously used an insert, dispose of the old insert. (Fig 1)
4. The new insert will have a soft silicone protective cap. Remove the cap.
5. Place the new insert into the port on the top of the lter, with the open end up.
DO NOT EMPTY THE CONTENTS INTO THE PORT. (Fig. 2)
6. Replace the cap on the port of the lter. Tighten rmly. You will experience leaking
water if not tightened properly.
7. Replace the lter following the instructions in the Section 7 - How to Relace The Filter.
19
Fig. 1
Fig. 2
Use scale guard if you have hard water and calcium inserts if you have soft water.

Using the Cleaning Filters
Use the Cleaning Filter Regularly if You Live in a Hard Water Area
How do I know If I have hard water?
If you are not sure about your hardness, use the hard water test strip provided in the Read Me First packet.
If I have hard water how often do I use a cleaning lter?
If your test strip indicated 50 - 120 ppm use the cleaning lter once every 6 months.
If your test strip indicated 121 - 250 ppm use the cleaning lter once very 3 months.
If your test strip indicated >251 ppm use the cleaning lter monthly to maintain optimal performance.
Instructions for Using the Cleaning Filter
Cleaning lter will eliminate most mineral scale on the electrodes and inside the chamber of your ionizer allowing for longer
life and better performance. It insures that the platinum/titanium plates remain clean and free of scale.
9
ATHENA H2
ALKALINE WATER IONIZER
AND HYDROGEN GENERATOR
20
Hard Water Causes Mineral Scale Build Up on Electrodes and Decreases Performance.
The cleaning lters are not included and must be purchased separately.
Alkaline, ionized water delivers profound benets created through ionization. However, the ionizer’s ability to create this alteration
can become compromised over time. Mineral build up or scaling essentially “coats” the electrode. A compromised electrode is limited
in its ability to transform the water eciently, resulting in a decrease in water quality and reduction in benets.
Do not use your regular lters
with the cleaning lter. Be sure
to use the empty cartridge that
comes with the cleaning lter.
Table of contents
Other AlkaViva Water Filtration System manuals
Popular Water Filtration System manuals by other brands

GWW
GWW ValueLine RO VALUE-5EZ50 Installation & service guide

Pentair
Pentair PRESHPOINT GRO-350BP Installation and operation manual

Growonix
Growonix Lil Boss Deluxe-3 GPM owner's manual

Philips
Philips AWP1811 user manual

AICKSN
AICKSN AICKSN-1500 Manual instruction

Pentair
Pentair EZ-RO 200/2G-BL Installation & operation guide

Katadyn
Katadyn Spectra Catalina 340C Installation and operating manual

Watts
Watts OF1465 Installation, operation and maintenance manual

Steinbach
Steinbach Speed Clean Classic 250N instruction manual

CWR
CWR CROWN NEW AIO CWR-BCCTB2 operating instructions

Dantherm
Dantherm ELITE 400 Service manual

Prio
Prio Expert M400 user guide