manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ALLEN & HEATH
  6. •
  7. I/O System
  8. •
  9. ALLEN & HEATH DX88-P User manual

ALLEN & HEATH DX88-P User manual

Other ALLEN & HEATH I/O System manuals

ALLEN & HEATH DT20 User manual

ALLEN & HEATH

ALLEN & HEATH DT20 User manual

ALLEN & HEATH DT22-M User manual

ALLEN & HEATH

ALLEN & HEATH DT22-M User manual

ALLEN & HEATH DT02 User manual

ALLEN & HEATH

ALLEN & HEATH DT02 User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

M-system R7D-YV2A instruction manual

M-system

M-system R7D-YV2A instruction manual

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DX88-P User Guide
AP13293

DX88-P
Getting Started Guide
The DX88-P is a fixed installation I/O Expander for Allen & Heath 96kHz digital
mixing systems. It provides 8 remote controlled mic/line preamps and 8 line
outputs. It connects to the mixer over a single Cat5 cable.
A second DX88-P, DX164-W, DX012 or DX168 can be connected via the DX B
connection.
The DX88-P can be operated freestanding or rack mounted using the optional
DX88-P-RK19/X kit.
Update the mixing system to the latest available version of firmware
before connecting the DX Expander. The unit might operate
incorrectly when running earlier firmware.
Contents
Check that you have received the following with your DX88-P unit:
•16 x 3-Way Phoenix Contact Plug
•DC 12V power supply
Front panel
Power LED indication and Ready Indicator.
Ready lights up when the unit is successfully booted and
ready to pass audio.
DX88-P User Guide
AP13293






Rear panel
Inputs Balanced Phoenix mic/line inputs.
Output Balanced Phoenix line outputs.
DC Input DC 12V connector via external PSU.
  Use only the power supply provided with the product (Adapter
Tech EDA4012-C14, A&H part code AM13303). The use of a different
power supply can cause electrical or fire hazards.
DX A Ethernet port for connection to the mixing system. The cable
carries the audio signals as well as preamp control and
system status data.
DX B Ethernet port for daisy chaining of a second unit.
Vents Ensure good ventilation at the sides and back of the unit.
Avoid obstruction of vents while operating. Avoid dirt or liquid
ingress.
Connection
dLive Surface /
MixRack, DX Hub,
DX Link card,
SLink
DX A
DX A
DX B
DX88-P User Guide
AP13293
Cables
Cat5e or higher STP cable is required for connections, with a maximum cable
length of 100m per connection.
The DX88-P and its network connection are for indoor use only.
Specification
Mic/Line Inputs
Balanced Phoenix, +48V phantom power
Mic/Line Preamp
Fully recallable
Input Sensitivity
-60 to +15dBu
Analogue Gain
+5 to +60dB, 1dB steps
Pad
-20dB Active PAD
Maximum Input Level
+30dBu (PAD in)
Input Impedance
>4kΩ (Pad out), >10kΩ (Pad in)
Mic EIN
-127dB with 150Ωsource
Analogue Outputs
Balanced Phoenix
Output Impedance
<75Ω
Nominal Output
+4dBu = 0dB meter reading
Maximum Output Level
+21dBu
Residual Output Noise
-92dBu (muted, 20-20kHz)
-90dBu (muted, 20-40kHz)
Operating Temperature Range
0°C to 40°C (32°F to 104°F)
Power
DC Input
12V DC via external PSU, 3.3A max
Mains Power Consumption
39.6W max
Dimensions and Weight
Width x Depth x Height x Weight
DX88-P
216.5 x 195.4 x 42.8 mm x 1.51kg
(8.5” x 7.7” x 1.7” x 3.33lbs)
DX88-P User Guide
AP13293
Dimensions
Read the Safety Instructions Sheet included with the product and the information printed on the panel before operating.
A limited one year manufacturer’s warranty applies to this product, the conditions of which can be found at:
www.allen-heath.com/legal
By using this Allen & Heath product and the software within it you agree to be bound by the terms of the relevant End
User Licence Agreement (EULA), a copy of which can be found at: www.allen-heath.com/legal
Register your product with Allen & Heath online at: http://www.allen-heath.com/support/register-product/
Check the Allen & Heath website for the latest documentation and software updates.
ALLEN&HEATH
Copyright © 2023 Allen & Heath. All rights reserved