Operating interval of pressure in water
supply network 0,5–6,0 Atm. (50–620 kPa).
Recommended pressure interval in water
supply network 2,0–5,0 Atm (206–515 kPa).
Difference of cold and hot water pressure
should not exceed + /– 10 %. In case
of deviation of water supply system
pressure parameters to the specied
values installation of devices for pressure
increase / reduction is required.
To avoid mechanical (abrasive) particles
penetration inside the product it is
compulsorily required to install lters of
100–300 mk.
MIXER INSTALLATION
1. Disconnect hot and cold water supply
system. Screw in eccentric adapters to the
outlets of the water supply pipelines having
rst sealed the threaded part with insulating
material. Adjust the location of the eccentric
adaptors so that they match together and
correspond to the mixer connecting position,
herewith mixer position should be horizontal
(distance between eccentric centers —
150 mm).
2. Remove (screw loose) aerator
4. Switch on water supply system. Once
mixer is in the closed position check all
connections for leakproofness. When
necessary arrange additional tightening and
sealing of connections.
5. Connect shower hose and hand shower.
6. Open cold and hot water supply through
mixer outow for short period of time,
afterwards close water supply and install
(screw tight) aerator.
of bath / shower mixer (to avoid aerator
clogging during rst water startup).
3. Install wall plates onto the eccentric
adaptors using a tool with soft coating
(to avoid damage of mixer nuts decorative
cover), connect mixer housing.