Amico AHM Service manual

Installation Instructions Manual
Adjustable Height Monitor (AHM) Arm

Preface
IMPORTANT, PLEASE READ CAREFULLY
Thank you for your purchase with Amico Accessories Inc.
This unit is designed for long lasting performance, providing the end user complies with assembly and maintenance
procedures. This Instruction Manual is your guide to ensure that you get the best performance out of the equipment.
Amico Accessories is not responsible for any damage as a result of (but not limited to) abuse and other problems that
may be a direct or indirect result of failure to comply with the instructions provided in this manual.
Please note these key words and symbols:
WARNING Steps where extra care should be taken to prevent injuries and damage.
NOTE Steps that point out helpful information.
Medical Facility Responsibilities
Preventive maintenance checks must be performed regularly to maintain the quality and performance of this product.
Any parts that may be broken, missing, worn, distorted, or contaminated in any way should not be used and all
affected parts should be replaced immediately. Should the necessity of any repair be suspected; please contact your
local distributor or call 1-877-264-2697.

Table of Contents
Section 1: Installation Preparation 4-6
Installation Tools Requirements 4
Pre-Installation Information 5
Typical Installation Reference for AHM 6
Section 2: Installation on Rail Systems 7-11
Mounting to the Monitor Rail System (MRS) with the MON-Adapter 7
OSHPD Anchor Pre-Approval OPA-1743 7
Mounting to Hill-Rom Vertical Rail (with the G-Track Adapter (GTA)) 8
Mounting to the VRS (Vertical Rail System)and the Ohmeda Rail 9-10
Mounting to the ARS (Amico Rail System) 11
Section 3: Monitor Installation 12-18
Monitor Mounting 12
Monitor Shelf: 3" (76.2 mm) Top/Back Mount, 5" (127 mm) Top/Back Mount and VESA 13
Monitor Shelf: 6" (152.4 mm) Drop On 14
Monitor Shelf: Philips Intellivue 15
Monitor Shelf: Welch Allyn 16
Monitor Mounting: VESA 75/100 17
Accessory Shelf: Disc 18
Section 4: Adjustments 19-27
Rotation (AHM Side To Side) 19
Monitor Tilt 20-21
Rotation (Monitor Head Side to Side) 22
Portrait and Landscape Adjustment 22
Portrait and Landscape Limiter 23
Height Locking Lever Adjustments 23
Attaching the Extension Arm 24
Counterbalance 25
Counterbalance: Fail Safe Mode 26
Cable Management: AHM Arm 27
Section 5: Troubleshooting, Maintenance and Product Classification 28-33
Preventive Maintenance 28-29
Troubleshooting 30
Cleaning 31
Part Number Matrix 32-33
Warranty Information 34

4Amico Accessories Inc.
Section 1: Installation Preparation
Installation Tools Requirements
The following table lists all the tools and parts required for installation
NOTE: Amico does not provide any display hardware, nor the tools necessary for assembly (All above in grey text).
A B
1
2
3
4
Item Item number Quantity
Phillips screw driver #2 A1 1
Hex keys (1/8" [0.3 cm], 3/16" [0.5 cm], M3, M4) A2 1 each
Socket wrenches (12 mm [1.2 cm],1/2" [0.05 cm]) A3 1 each
Adjustable wrench A4 1
AHM arm B1 1
Mounting adapter/plate (many options)
and Monitor dependant hardware set B2 1
Mounting shelf (0-9, W) B3 1
Extension arm (optional) B4 1

www.amico.com 5
Section 1: Installation Preparation
Pre-Installation Information (Please read carefully before starting)
WARNING: VERIFY THAT RAILS HAVE BEEN INSTALLED IN ACCORDANCE WITH AMICO RAIL INSTALLATION
INSTRUCTIONS. RAIL FAILURE WITH DEVICES MOUNTED CAN CAUSE SERIOUS INJURY AND EQUIPMENT DAMAGE.
WARNING: IT IS DANGEROUS TO USE THE ARM FOR WEIGHTS OUTSIDE OF THE RATED RANGE. STRUCTURAL
FAILURE AND/OR SERIOUS INJURY COULD RESULT.
WARNING: DO NOT POSITION THE MONITOR ARM ABOVE A PATIENT.
WARNING: THE AHM MONITOR ARM CONTAINS A STRONG GAS SPRING WHICH IS USED TO COUNTERBALANCE
THE WEIGHT OF THE MOUNTED DEVICE. THE ARM HOUSING SHOULD NEVER BE DISASSEMBLED BY NON-AMICO
PERSONNEL. FAILURE TO FOLLOW THESE GUIDELINES COULD RESULT IN SERIOUS INJURY. THE MOUNTED DEVICE
SHOULD BE WITHIN THE “DUTY WEIGHT RANGE” FOR BEST PERFORMANCE AND RELIABILITY.
WARNING: IT SHALL BE THE RESPONSIBILITY OF THE HOSPITAL, ITS CONSULTANTS AND/OR CONTRACTORS TO
DETERMINE IF THE WALL IS ADEQUATE TO SAFELY MOUNT THE SPECIFIC INSTRUMENT. THIS INCLUDES THE
SELECTION OF APPROPRIATE FASTENERS AND THE PROPER INSTALLATION OF EQUIPMENT, REGARDLESS OF WHAT
IS SUPPLIED WITH YOUR AHM MONITOR ARM. SEE RAIL INSTRUCTIONS FOR SPECIFIC WALL CHANNEL GUIDELINE
INFORMATION.
WARNING: VERIFY THE WEIGHT OF THE DEVICE TO BE MOUNTED. (AHM LCD AND PATIENT MONITOR ARMS ARE
RATED AT 40 LBS (18.1 KG) OF LOAD, THIS RATING APPLIES TO ALL AHM WITH OR WITHOUT EXTENSIONS). (PLEASE
REFER TO WEIGHT RATING LABEL, LOCATED EITHER ON THE TOP OR BOTTOM OF THE ARM ASSEMBLY, DEPENDING
ON THE MODEL). CHECK THAT THE DEVICE TO BE MOUNTED DOES NOT EXCEED THE WEIGHT RATING. SERIOUS
INJURY AND DAMAGE TO THE ARM CAN OCCUR AS A RESULT OF OVERLOADING ARM ASSEMBLY. THE ABOVE
WEIGHT RATING APPLIES TO ALL UNITS WITH EXTENSIONS.
For installation on non-Amico rails, ensure the rail is safe for the application.
If you are unsure about any part of the installation process or product use, please contact an Amico Accessories
product Specialist: 1-877-264-2697
Considerable efforts have been made to ensure the safety of your hospital staff and your patients. The installation itself
is beyond the control of Amico Accessories. Accordingly, Amico Accessories will not be responsible for failure related to
the installation of the product.
HAVE A PRODUCT QUESTION? GIVE US A CALL AT: 1-877-264-2697

6Amico Accessories Inc.
Typical Installation Reference for AHM
The diagram below illustrates the components referenced in relation to one another in the installation of the AHM
Monitor Arm. Please follow the instructions outlined herein to ensure proper installation.
AHM MONITOR ARM
1. Monitor Mounting Adapter
VESA LCD mount shown, other options available
2. Monitor Head - Rotation
Monitor rotation adjustment
3. Height Locking Lever
Locks the arm at a desired height
4. Counter Balance
Used to adjust for zero movement
5. Extension Arm
6" (152.4 mm) extension arm shown
6. Mounting Adapter
MON adapter shown for MRS rail
7. Monitor Head - Tilt
Tilt Adjustment Handle
8. Cable Management
Manages the cables of the monitor for better organization
Section 1: Installation Preparation
1
2
3
4
5
6
7
8

www.amico.com 7
Section 2: Installation on Rail Systems
Mounting to the Monitor Rail System (MRS) with the MON-Adapter
WARNING: NEVER ATTEMPT TO MOUNT OR REMOVE THE ARM
FROM THE RAIL WHEN A MONITOR IS INSTALLED
WARNING: TO PREVENT THE ADAPTER FROM FALLING DOWN
THE CHANNEL, ENSURE THAT THE FOUR SET SCREWS ARE
FASTENED TO THE TIGHTEST POSSIBLE POSITION (FIGURE 1).
NOTE: For safety, top and bottom stoppers prevent the adapter
from sliding out of the MRS. To remove, the adapter must be
taken out from the top of the rail with the top stopper pressed
back into the rail (Figure 2).
1. With the AHM arm locked in the highest vertical position, support
the bottom of the arm and guide the MON-channel adapter into
the top of the wall channel.
2. Once the arm is at the desired height, tighten all four screws on
the MON-channel adapter using a 1/8" (3 mm) hex key (Figure 1).
Figure 2
Bottom
Stopper
Top Stopper
MRS Rail: Length for representational use only
Figure 1
Standard
MON-Adapter
1/8" (3 mm)
set screws
MRS Rail
OSHPD Anchor Pre-Approval OPA-1743
In compliance with standards established for the anchor and installation of instrument support systems by the
California Office of Statewide Health Planning and Development (OSHPD), Amico Accessories Inc. has obtained
preapproval for MRS 19" (48.26 cm) Wall Channels or longer with extension arm. For proper installation requirements
please refer to our OPA Document.

8Amico Accessories Inc.
Section 2: Installation on Rail Systems
Mounting to Hill-Rom Vertical Rail (with the G-Track Adapter (GTA))
WARNING: TO PREVENT THE ADAPTER FROM FALLING DOWN THE CHANNEL, ENSURE THAT THE SCREWS ARE
SECURED TO THE TIGHTEST POSSIBLE POSITION. AFTER INSTALLATION, ROTATE THE AHM ARM SIDE TO SIDE AND
VERIFY NO MOVEMENT IS PRESENT BETWEEN THE ADAPTER AND THE RAIL.
WARNING: REMOVAL OF LOCK NUTS WILL REQUIRE A NEW SET FOR REINSTALLATION. PLEASE CONTACT AMICO
ACCESSORIES INC. FOR SPARE PARTS, 1-877-264-2697.
1. With the AHM arm locked in the highest vertical position, support the bottom of the arm and guide the head of the
top screw into the opening of the rail (Figure 1). Ensure the flange on the GTA is properly aligned with the rail. Slide
the GTA up so that the head of the bottom screw slides into the opening of the rail.
2. Position the arm to the desired height. Tighten the jam nuts and then the lock nuts on the top and bottom of the
adapter using a 12 mm wrench (Figure 2). Cover the nuts with the plastic caps provided (Figure 3).
Figure 1
Hill-Rom
Rail
Front
Opening of
the rail
Jam nut,
lock nut, and
plastic cap
Figure 3
12 mm nut, lock nut,
and plastic cap
Figure 2
Flange
Backside
Head of
the top GTA pin
Head of the
bottom GTA pin
G-adapter Screw

www.amico.com 9
Section 2: Installation on Rail Systems
Mounting to the VRS (Vertical Rail System)and the Ohmeda Rail
WARNING: Both adapters must be sitting in the rail securely.
WARNING: To prevent the adapter from falling down the channel ensure that the screw knobs are fastened to the
tightest possible position. After the installation, rotate the AHM arm side to side to verify that no movement is
present between the adapters and the rail.
WARNING: Please be sure to fasten the nuts to the screw knobs since screw knobs alone are not safe to hold the
weight of the monitor (Figure 3 and 6).
NOTE: On the side of the V-adapter and the D-adapter there are screw knobs that lock the adapter into the rail
once secured. When you turn the knob counter-clockwise the side of the adapter moves outwards, putting the
adapter into an unlocked position (Figure 1 and 4). When the knob is turned clock-wise the side of the adapter
moves inwards, putting the adapter into a locked position (Figures 2 and 5).
V-adapter for the VRS: Sliver adapter (Figure 1 to 3).
D-adapter for the Ohmeda rail: Black adapter (Figure 4 to 6).
Figure 1
Screw knob
Slide inwards
Locked
Figure 4
Screw knob
Slide inwards
Locked
Figure 2
Screw knob
Slide outwards
Unlocked
Figure 5
Screw knob
Slide outwards
Unlocked
Figure 3
Opposite side of the V-adapter
Figure 6
Opposite side of the V-adapter

10 Amico Accessories Inc.
Section 2: Installation on Rail Systems
Mounting to the VRS (Vertical Rail System)and the Ohmeda Rail
1. Ensure the V-adapter (or the D-Adapter) is in the UNLOCKED position, and ensure the AHM arm is LOCKED in the
highest vertical position.
2. Angle the adapters into the groove of the channel. Then straighten once inserted (Figures 4 and 5).
3. Tighten screw knobs with a 3/16" (4.76 mm) HEX key when adapter is at desired height. Once tightened, the screw
knob will protrude from the other side. Fasten the nut to the screw to secure the adapter. Check all nuts and screw
knob are tightened to ensure V-adapter is locked (Figure 6).
V-adapter: Silver adapter (Figure 1 and 2).
Dovetail adapter: Black adapter (Figure 4 and 5).
Figure 2 Figure 3
Mounted on the VRS
Figure 1
AHM Arm
V-adapter
Screw Knob
Figure 4
AHM Arm
D-Adapter
Screw Knob
Figure 5

www.amico.com 11
Section 2: Installation on Rail Systems
Mounting to the ARS (Amico Rail System)
WARNING: NEVER ATTEMPT TO MOUNT OR REMOVE THE ARM FROM THE RAIL WHEN A MONITOR IS INSTALLED.
WARNING: YOUR AHM IS PRE-ASSEMBLED WITH THE ARS ADAPTER(S), ENSURE THAT THE ARS ADAPTER IS
SITTING INSIDE THE RAIL PROPERLY BEFORE INSTALLING A MONITOR. DO NOT INSTALL THE AHM WITH JUST ONE
ADAPTER. BOTH ARS ADAPTERS MUST BE INSTALLED. ONLY EXCEPTION IS IF YOUR UNIT IS TO BE INSTALLED ON A
SINGLE ARS RAIL. IN THIS CASE, ENSURE THE SUPPORT BLOCK IS SITTING FLUSH AGAINST THE WALL.
(Following steps apply only to units to be mounted on a headwall)
1. Determine the best location to install the AHM arm, then remove the two screws at the bottom of the AHM
horizontal adapter to free one of the ARS adapters. Install the freed ARS adapter into the bottom rail by angling the
upper lip into the inside lip of the ARS rail, hold the tab on the ARS and push the ARS adapter into the rail. Once
secure, release the tab (Figure 1).
2. Mount the AHM arm by angling the top ARS adapter attached to the ARS horizontal adapter in the same way as
step 1, ensuring the two holes on the bottom ARS adapter can be seen through the AHM horizontal adapter, secure
the two Philips screws from the bottom of the AHM horizontal adapter (Figure 2).
(Following step applies only to units to be mounted on a single rail)
3. Install the AHM arm by installing the ARS adapter attached to the AHM arm by angling the upper lip into the inside
lip of the ARS rail, hold the tab on the ARS and push the ARS adapter into the rail. Once it is secure, release the tab
ensure the support block is sitting flush and firmly against the wall (Figure 3).
ARS Adapter
Lever on ARS
ARS Rail
Figure 1
Figure 2
AHM Horizontal
Adapter
ARS Adapter
installed
ARS
Rail
Mounting on
a headwall
AHM Arm
Figure 3
Mounting
Adapter Channel
ARS Rail
Support Block
Mounting on a
single ARS AHM Arm

12 Amico Accessories Inc.
Section 3: Installation to Monitor and Accessory
Monitor Mounting
WARNING: ENSURE THAT THE ARM IS IN THE HIGHEST POSITION AND IS LOCKED BEFORE MOUNTING OR
REMOVING THE ARM FROM THE CHANNEL.
WARNING: ENSURE THE MONITOR SHELVES/PLATES PROVIDED BY AMICO ACCESSORIES INC. OR OTHER
MANUFACTURERS ARE ASSEMBLED AS DIRECTED AND MATCH THE SHELF REQUIREMENT. IF A MONITOR SHELF OR
PLATE DOES NOT MATCH THE REQUIREMENT, PLEASE CONTACT AMICO ACCESSORIES INC., 1-877-264-2697.
NOTE: Amico Accessories Inc. carries a variety of Mounting Shelves and adapters that attach to the AHM Arm.
View the AHM Matrix on page 32 and 33 for more information.

www.amico.com 13
Section 3: Installation to Monitor and Accessory
Monitor Shelf: 3" (76.2 mm) Top/Back Mount, 5" (127 mm) Top/ Back Mount and VESA
WARNING: ENSURE THE MOUNTING SHELF IS SECURELY LOCKED AND HORIZONTAL TO PREVENT THE MONITOR
FROM SLIDING AND FALLING.
WARNING: ON THE BOTTOM OF THE MOUNTING SHELF THERE IS A PLUNGER THAT SECURES THE SHELF TO THE
MOUNTING ADAPTER. SIMPLY PULL DOWN ON THE PLUNGER, ALIGN THE ADAPTER PLATE WITH THE SHELF AND
RELEASE THE PLUNGER ONCE POSITIONED OVER THE CLEARANCE HOLE (FIGURE 3).
NOTE: The plunger can be locked in the open position by pulling and twisting it.
1. First install the mounting adapter to the device (Please refer to the adapter installation manual provided with the
adapter) (Figure 1).
2. Loosen the plastic screws on the bottom side of the mounting shelf. Pull down on the plunger lock at the bottom of
the mounting shelf and twist it to keep it open. Slide the adapter laterally onto the mounting shelf until the plunger
aligns with the clearance hole at the front of the mounting adapter (Figure 3).
3. Release the plunger and tighten the plastic screws by hand (Figure 4).
Mounting shelf
Monitor
Mounting
adapter
Front of the
mounting
adapter
Monitor
dependant
hardware
Figure 1 Figure 2
Mounting shelf
Front of
the shelf
Plunger Lock
5" (127 mm) mounting shelf is shown above
Plastic
Screws
Plunger released
Plunger pulled
Figure 3 Figure 4

14 Amico Accessories Inc.
Monitor Shelf: 6" (152.4 mm) Drop On
WARNING: ENSURE THE MOUNTING SHELF IS SECURE AND VERTICAL TO PREVENT THE MONITOR FROM SLIDING
AND/OR FALLING.
NOTE: Quick installation system: On the back of the mounting plate there is a plunger that secures the plate to
the mounting adapter. Simply slide and align the adapter to the shelf and the plunger will automatically engage
and lock.
1. First, install the mounting adapter to the back of the monitor (Please refer to the adapter installation manual
provided with the adapter).
2. Lift the monitor and slide the mounting adapter plate on to the mounting shelf. Slide the monitor down until
the mounting hole on the mounting adapter aligns with the plunger (Figure 1). When the hole and the plunger
are perfectly aligned the plunger will automatically lock. If the plunger does not lock automatically then lock the
plunger manually by turning it. Tighten the locking screws by hand to the tightest possible position (Figure 2).
Figure 1 Figure 2
Mounting
shelf
Plunger Lock
Locking screws
Mounting adapter
plate
Mounting hole
Section 3: Installation to Monitor and Accessory

www.amico.com 15
Monitor Shelf: Philips Intellivue
WARNING: ENSURE THE MOUNTING SHELF IS FIRMLY LOCKED AND HORIZONTAL TO PREVENT THE MONITOR
FROM SLIDING AND FALLING.
NOTE: Philips recommends a Maximum tilt of 15°.
NOTE: It is recommend to use M6 x 20 mm screws with thread locker or patched screws in order to eliminate
possible dangers.
1. Attach the table top mount from Philips (not supplied by Amico) to the mounting shelf by securing the 3 screws
through the shelf (Figure 2).
2. Place the monitor to the table top mount until it clicks (Figure 3).
3. Tilt the monitor to the desired angle and re-adjust the tension as needed with a 12 mm wrench (Figure 4).
Philips Table Top Mount
(not supplied)
12 mm hex nut
To tighten
To loosen
Three 20 mm
M6 screws
Table top
mount
Mounting shelf
Figure 1 Figure 2 Figure 3 Figure 4
Section 3: Installation to Monitor and Accessory

16 Amico Accessories Inc.
Monitor Shelf: Welch Allyn
WARNING: ENSURE THE MOUNTING SHELF IS SECURE AND HORIZONTAL TO PREVENT THE MONITOR FROM
SLIDING AND FALLING.
1. To attach the monitor to the Welch Allyn shelf, lift the monitor to match the front lip of the mounting plate. Slide the
monitor laterally until the mounting hole on the monitor aligns with the thumb screw on the adapter (Figure 1).
2. Tighten the thumb screw to the tightest possible position (Figure 2).
Figure 1 Figure 2
Thumb screw
Front lip
Thumb screw
Section 3: Installation to Monitor and Accessory

www.amico.com 17
Section 3: Installation to Monitor and Accessory
Monitor Mounting: VESA 75/100
WARNING: ENSURE THAT THE AHM ARM IS IN THE HIGHEST VERTICAL POSITION AND LOCKED BEFORE
MOUNTING OR REMOVING DEVICES FROM THE FALCON WORKSTATION.
NOTE: See page 29 for instructions on locking and unlocking the AHM Arm.
NOTE: 4x M4 screws are provided for mounting the display to the VESA Head, different screws may be needed if
the provided screws are not the right size, standoffs may be needed depending on the hole pattern on the
display.
1. Determine the display mounting configuration. VESA 75 (75 mm x 75 mm M4 thread) or VESA 100 (100 mm x
100 mm M4 threads).
2. VESA 100 configuration: Partially thread two screws into the top 2 holes in the back of the display. The display can
then be hung up on the VESA Head through the two slots at the top. Insert 2 more screws through the VESA 100
mounting holes at the bottom and tighten all screws (Figure 1).
3. VESA 75 configuration: Rotate the VESA Head so the 2 slots for the VESA 75 configuration are located at the top.
Partially thread two screws into the top 2 holes in the back of the display. The display can then be hung up on the
VESA Head through the two slots at the top. Insert 2 more screws through the VESA 100 mounting holes at the
bottom and tighten all screws.
4. When removing the display, the display arm and the display should be placed at the highest position
(Figure 2). Remove the 2 bottom screws from the VESA plate, loosen the top 2 screws, and lift the display off the
VESA plate.
Front of the VESA 75/100
M4 mounting
hole for VESA 75
M4 mounting
hole for VESA 100
Figure 1 Figure 2

18 Amico Accessories Inc.
Accessory Shelf: Disc
NOTE: It is possible to attach accessories to the top or bottom side of the AHM Arm using this same mount
(Figure 1).
NOTE: Amico Accessories Inc. carries a variety of different accessories that attach to the head of the AHM Arm.
Figure 1
Figure 5
Figure 2
Figure 6
Figure 3
Figure 7
Figure 4
Figure 8
6" and 12" post
(152.4 mm and 304.8 mm)
Single or dual
cord holder
Keyboard
handle
Screw type:
10 x 32
Top side Bottom side
(Disc installed on the top and Disc
installed on the bottom)
Dual Head Keyboard Tray Laptop Holder ARS Rail
Section 3: Installation to Monitor and Accessory

www.amico.com 19
Rotation (AHM Side to Side)
WARNING: IN AHM WITH EXTENSIONS, BOTH
ARMS HAVE A 180 DEGREE ROTATION. ENSURE
PROPER CLEARANCE AROUND THE ARM(S) TO
AVOID COLLISION.
NOTE: If the arm becomes difficult to rotate, or
too loose, please contact Amico Accessories Inc.:
1-877- 264-2697.
Rotation at the MON Adapter:
To rotate the arm, simply push on the side of the arm or the mounted monitor in the direction desired (Figure 1).
Rotation at the End of Extension
Applies to AHM IT Stations with Extension Arm AHM 55, 15, 35, 75 and AHM-IT 55, 15, 35, 75
To rotate at the end point (near wall), push on the side of the extension arm, near the mid-way point. (Figure 2) To
rotate at the midway point, hold the extension arm with one hand and push on the side of the AHM arm with the
mounted monitor in the direction desired (Figure 3).
Section 4: Adjustments
12
3
DETAIL 1
SCALE 1 : 4
DETAIL 2
SCALE 1 : 4
DETAIL 3
SCALE 1 : 4
Detail 1
Scale 1:4
Detail 2
Scale 1:4
Detail 3
Scale 1:4
(Figure 1)
Arm rotated
(Figure 2)
To rotate at first arm
First arm rotated
(Figure 3)
To rotate at second arm
Second arm rotated

20 Amico Accessories Inc.
Section 4: Adjustments
Monitor Tilt
WARNING: ALWAYS SUPPORT THE MONITOR IF ADJUSTING THE TILT ANGLE WHILE A MONITOR IS MOUNTED.
WARNING: FOR HEAVIER MONITORS, IT IS STRONGLY RECOMMENDED TO CHECK WHETHER THE TILT-SETTING
LEVER IS TIGHTENED TO THE TIGHTEST POSITION WHILE THE MONITOR IS ATTACHED. IF THE ADJUSTMENT LEVER
CANNOT BE TIGHTENED ENOUGH TO SECURE THE MONITOR IN PLACE, PROCEED TO STEP 3.
WARNING: DO NOT ADJUST TILT-ANGLE WITHOUT FIRST LOOSENING THE TILT-SETTING LEVER.
NOTE: Tilt-angle setting is ONLY ACHIEVED BY TIGHTENING THE TILT-SETTING LEVER. DO NOT tighten nuts
adjacent to the Tilt-setting Lever.
Tilt Hinge Tilt-Setting Lever
4 mm (5/32")
Allen Nut
Patient Monitor
Shelf
1. To TIGHTEN the Tilt-Hinge (in order to set the desired tilt angle), TURN the Tilt-Setting Lever CLOCKWISE. [Turning
the Lever COUNTER-CLOCKWISE will ENABLE tilt movement]
4 mm Allen Key 12 mm Socket Wrench
Tools Reference
Tighten Loosen
Other manuals for AHM
1
Table of contents
Other Amico Rack & Stand manuals

Amico
Amico Falcon IT Guide

Amico
Amico RS-42-PKS Series Original operating instructions

Amico
Amico Sparrow Original operating instructions

Amico
Amico Falcon IT User manual

Amico
Amico HMA-VESA-SPK-PLT Technical specifications

Amico
Amico ARS User manual

Amico
Amico Gooseneck User manual

Amico
Amico BARCHLD2 Product manual

Amico
Amico VRS User manual

Amico
Amico SSM Arm Guide