Ampetronic C Series User manual

Box Contents
• 1xCSeriesDriverincluding:
• 1xLoopconnectors(2xforC5-2,C7-2)
• 1xDCconnector
• 2xInputconnectors
• 1x100Vlineconnector
• 1xLineoutconnector
• 2x2mmsteel1Urackmountbrackets
• Alsoincludes:
• 1xCSeriesquickstartguide
• 1xPowercable(regionspecic)
• 1xInductionLoopSign
• 4xselfadhesivefeet
This symbol is used to alert the user to important operating or maintenance instructions.
The Lightning bolt triangle is used to alert the user to the risk of electric shock.
1. SAFETY
1. Itisimportanttoreadtheseinstructions,andtofollowthem.
2. Keepthisquickstartguideinanaccessibleplace.
3. Cleanonlywithadrycloth.Cleaninguidsmayaecttheequipment.
4. Donotblockanyventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
5. Donotinstallthisequipmentnearanyheatsourcessuchasradiators,heatingventsorotherapparatus
thatproducesheat.
6. WARNING–THISAPPARATUSMUSTBEEARTHED/GROUNDED.
7. Onlypowercordswiththecorrectpowerconnectormaybeusedtomaintainsafety.Cablesincorporating
theUK13Afusedplug,SchukowithearthingcontactsandULapproved“groundingtype”areacceptable.
Thesemustbepluggedintopoweroutletswhichprovideaprotectiveearth.
8. Referallservicingtoqualiedpersonnel.Servicingisrequiredwhentheapparatushasbeendamagedin
anyway,suchasapowersupplycordorplugisdamaged,liquidhasbeenspilledorobjectshavefallen
intotheapparatus,theapparatushasbeenexposedtoanyrainormoisture,doesnotoperatenormally
orhasbeendropped.
9. WARNING–Toreducetheriskofreorelectricshock,donotexposethisapparatustorainor
moisture.Theapparatusshallnotbeexposedtodrippingorsplashingandnoobjectslledwith
liquids,suchasvases,shallbeplacedontheapparatus.
10. Warning:Connectiontoa100Vlinesystemmayinvolvetheriskofelectricshockandtherefore
mustbecarriedoutbyaninstructedorskilledperson.
2. TOOLS AND EQUIPMENT
Smallhandtoolsincludingawirestripper,smallatbladeandposiscrewdriverswillberequired.
Amagneticeldstrengthmeter,LoopworksMeasureApp&R1Reciever,oratminimumaninductionloop
receiverisvitaltocheckthattheloopsystemisprovidingthedesiredlevelofperformance.
Ampetronic C Series Quick Start Guide Page 1
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE THE
COVER. THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL
9.0
4.5
2.3
1.2
CURRENT (A pk)
CLIP
CH B
CH A
36
28
20
12
AGC (dB)
ERROR
QUICK
MAIN
STATUS
2.1 Current
Current =-52.0dB
MENU
MULTILOOP DRIVER
D SERIES
NETWORKED DUAL 14A DSP
Induction Loop Driver
~ 230V 45 - 65Hz
Power: 85W Fuse: T 3.15A L
Designed and Engineered in the UK
D14-2
LOOP O/P CONNECTIONS
1-
2-
1+
2+
www.ampetronic.co
CHANNEL A
LOOP OUTPUT 0.1A
+12V
DC OUTPUT
Serial No.
CHANNEL B
LOOP OUTPUT USB
(UPDATE ONLY) ETHERNET SLAVE IN SLAVE OUT
AC POWER INPUT
INPUT 2
MIC / LINE / AES
INPUT 1
MIC / LINE
C Series Quick Start Guide

4. SETTINGS
TheCSeriesdrivershavetheiradjustmentssetindecibels(dB).Asettingof0dBequatestomaximum
currentortomaximuminputgain.Anegativevaluewillreducethecurrentorinputgainaccordingly.
Fromthefactorythedriversareprovidedwiththefollowingsetting:
5. ADDITIONAL FEATURES
• Home screen timeout –ifnoactionistakeninamodescreenafter30sthehomescreenisdisplayed.
Foravaluescreenthetimeoutis60s.
• Sleep mode–Aftera10minuteperiodofuseroraudioinactivitythedriverturnsonthe‘Loopoutputs
disabled’testsignalandturnsothescreentosavepower.TheStatusledashesgreentoindicatethis.
Anyuseractivityorpresenceofaudiosignalbringsthedriveroutofsleep.Theinactivitytimecanbe
changedviathewebsite(wherenetworkoptiontted)
• Lock screen –Alongpressonthehomebuttonbringsupthelockmenu.Thisgivesaccesstostandby,
re-start(sameasinsettingsmenu)&lock.Selectinglockmakestheusercontrolsinactive.Anyuser
inputresultsinapadlockbeingdisplayed.Tounlocktheunitpressthehomebuttonsixtimes.Unlock
instructionsareshownbrieywhenlockisselected.
• Standby –Thisisauserimposedsleep.Onlyuseractivity(notaudiosignal)bringsthedriveroutof
standby.
3. INPUTS AND OUTPUTS
Thedriverhastwoinputslabelled1and2.Each
inputcanbeseparatelyconguredtomicorline
signallevelusingarearpanelpushswitch.Global
24Vphantompowercanbeenabledtosupply
anyinputsettomiclevel.Alternativelyinput2can
accepta100Vlineusingadedicated2pinsocket.
Do not use both input 2 sockets at the same
time.
Warning:Connectiontoa100Vline
systemmayinvolvetheriskofelectricshock
andthereforemustbecarriedoutbyaninstructed
orskilledperson.
ThedriverhastwoloopoutputslabelledLoopA
andLoopB.Inordertoachievecorrectoperationit
isrecommendedtheloopandfeedresistance
shouldbebetween0.2and10Ω(atDC).
(Screen)
-(Signalcold)
+(Signalhot)
-
-
+
+
TwistedPairpositiveand
negative.
Home/power
button
Navigate(rotate)
andselect(press)
control
128x160pixel
colourdisplay
StatusLED:
Solidgreen=OK
FlashingRed=error–checkerrorlist.
Flashinggreen=sleeporstandbymode
Flashingamber=reprogramming
Ampetronic C Series Quick Start Guide
Page 2
• Current:-20dBfromfulloutput
• MetalLossCompensation(MLC)OFF
• InputGainChannel1-80.0dB
• InputGainChannel2-80.0dB
• DriverName“Namenotset”
• PhaseShiftON
• EthernetParametersSetbyDHCP
Figure1:Inputconnections Figure2:Outputconnections
Do not run input and output cables close together
Figure3:Frontpaneldisplayandcontrol

Ampetronic C Series Quick Start Guide Page 3
6. NETWORK CONNECTION (OPTION)
WherettedCSeriesdriversfeatureawebinterfacethatcanbeviewedinawebbrowser.Although
optimisedfortheChromebrowser,anybrowsercanbeusedtoviewtheinterface.Thewebinterfaceis
usedtomonitorandadjustthedriver.YouwillbeaskedfortheUserNameandPasswordforthedriverasa
deterrenttounauthorisedparties.Thesevaluesarecasesensitiveandneedtobeenteredoncepersession
toaccessthedriver.
7. TROUBLESHOOTING
OUTPUT A / B OPEN CIRCUIT: ThedriverhasdetectedthattheloopconnectedtoA/B
outistoohighimpedance.
HEATSINK TOO HOT PLS SWITCH OFF: Thedriverheatsinkhasreachedacriticaltemperatureand
thedrivermustbeswitchedo.
Thefollowingerrormessagesallindicateanerrorintheinternalcircuitryofthedriver.Please
contactAmpetronictechnicalsupportifanyoftheseerrorsareseen,quotingtheerrormessagetext.
OUT A / B IDLE OVERCURRENT
OUT A / B FUNC TEST HIGH OVERCURRENT
OUT A / B FUNC TEST LOOPS CROSSWIRED
Theseerrormessagesindicateapossibleerrorwiththelooportheconnectionstotheloop:
LOOP A / B R < 200mR FIX AND RESTART: Thedrivermeasured<200mRfortheloopimpedance.
Thisistoolowforthedriverandmustbexedbeforethedriverwillnishthestart-updiagnostics.
Switcho,xthefaultandswitchonagain.
LOOP A / B > 10R LOOP COULD CLIP:Theloopisnotopencircuitbuthasaresistanceof>10R.
Thisistoohighandthedriverwillcliponoutputpeaks.Thisisawarningandthedriverwillcontinue
after5seconds.
CHANNEL A / B OPEN CIRCUIT: Thismessageisdisplayediftheloopisdisconnectedwhilstthe
driverisoperating(e.g.ifacarpetttercutstheloop).Themessageisdisplayedonthefrontpanelfor
5secondsandonthewebinterface.
Theseareinformationmessagesanddonotindicateanerror:
DIAGNOSTICS IN PROGRESS: Thismessageisdisplayedonthefrontpanelwhilstthestart-uptests
arebeingperformed.
New IP Address XXX.XXX.XXX.XXX AnewEthernetaddresshasbeenassignedtothedriver.This
canoccurwhenanEthernetcableispluggedintothedriverortheDHCPsystemre-assignsanewIP
address.
Thesemessagesappearinthestatusmenuwhentheassociatederrorispresent:
Power Limit - derated: Thedriverisoverloadedandthedrivecurrenthasbeenreduced
Loop A open circuit: ThedriverhasdetectedanopencircuitonloopA.
Loop B open circuit: ThedriverhasdetectedanopencircuitonloopB.
Temp Limit - derated: Theinternalheatsinkistoohotandthedrivercurrentonboth
channelshasbeenreduced.
Temp Limit - muted: Theinternalheatsinkhasreachedanunacceptableleveland
outputshavebeenturnedo.
User Name = superadmin, netadmin, audioadmin
Passwords = ampetronic (default)
Fourlevelsofaccessareavailable:
1. superadmin-allowsaccesstoallsettings
2. netadmin-accessthenetworksettingspage
only
3. audioadmin-accesstheaudiosettingspages
only
4. nologin-allowsaccesstostatuspage

UP19802-2ContentsCopyright©AmpetronicLtd2018.Allrightsreserved.
Channel A Clipping: ThedriveroutputmaximumvoltageisbeingexceededandtheloopAsignalis
beingclipped.
Channel B Clipping: ThedriveroutputmaximumvoltageisbeingexceededandtheloopBsignalis
beingclipped.
8. ASSOCIATED DOCUMENTS
• UP19801–CSeriesInstallationHandbook&UserGuide
• UP39801–CSeriesDatasheet
Associatedocumentsareavailableasadownloadfromwww.ampetronic.co,inLoopworksLearnorcanbe
requestedbycontacting[email protected]/+44(0)1636610062
9. WARRANTY
ThisproductcarriesaveyearpartsandlabourwarrantyfromdateofshipmentfromAmpetronic.Toqualify
fortheveyearwarranty,theproductmustberegisteredatwww.ampetronic.co(products/warranty),without
whichthewarrantywillbevalidfortwoyearsonly.
Thewarrantycouldbeinvalidatediftheinstructionsinthishandbookarenotfollowedcorrectly,oriftheunit
ismisusedinanyway.
10. DECLARATION OF CONFORMITY
Manufacturer: AmpetronicLtd.
Unit2,TrentsideBusinessVillage,FarndonRoad,Newark,
Nottinghamshire,NG244XB,UnitedKingdom.
Declaresthattheproduct:
Description: Hearing/InductionLoopDriver
Type name: CSeries
inaccordancewiththefollowingdirectives,conformstothefollowingDirective(s)andNorm(s):
2014/35/EU TheLowVoltageDirectiveanditsamendingdirectives
2014/30/EU TheElectromagneticCompatibilityDirectiveanditsamendingdirectives
2011/65/EU TheRoHSDirectiveanditsamendingdirectives
andhasbeendesignedandmanufacturedtothefollowingspecications:
Safety Standards:
EN62368-1/ Audio,videoandsimilarelectronicapparatus–Safetyrequirements
UL62368-1
EMC Standards:
EN55032 EMC–Productfamilystandardformultimediaequipment:Emission
EN55035 EMC–Productfamilystandardformultimediaequipment:Immunity
Date: August2018
J.R. Pieters
Managing Director,
Ampetronic Ltd.
CAUTION:ChangesormodicationsnotexpresslyapprovedbyAmpetronicoranauthorised
partnercouldvoidtheuser’sauthoritytooperatetheequipment.
NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttoPart
15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhenthe
equipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradiofrequency
energyand,ifnotinstalledandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferenceto
radiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhich
casetheuserwillberequiredtocorrecttheinterferenceattheirownexpense.
Ampetronic C Series Quick Start Guide
Page 4
Table of contents
Other Ampetronic Stereo System manuals