manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Anden
  6. •
  7. Humidifier
  8. •
  9. Anden AS35 User manual

Anden AS35 User manual

ABSORPTION
DISTANCE
SUPPLY DUCT
AIRFLOW
AS35 Steam Humidifier
Quick Start Guide
3
PITCH*
DUCT
DISPERSION
TUBE
TUBELETS
5" MINIMUM
* PITCH STEAM HOSE DOWN
FROM DISPERSION TUBE
TO HUMIDIFIER:
2"/FT (15%) MINIMUM
WHEN USING STEAM HOSE.
1/4"/FT WHEN USING
HARD PIPE.
STEAM HOSE OR PIPE.
INSULATE PIPE WITH
1" FIBERGLASS
TO REDUCE
STEAM LOSS.
90° LONG
SWEEP OR TWO
45° ELBOWS
90-2510
2
90-1521
Choose a location in a
conditioned space
Place outside the grow room if possible. The capacity of the
humidifier is reduced by the length of the steam hose or pipe due
to condensation. The maximum recommended length of steam
hose is 6 feet. Use hard pipe insulated with 1" thick insulation
rated for 212°F or higher for lengths greater than 6 feet. If 6-foot
steam hose does not reach from humidifier to dispersion tube,
splice in 1" copper pipe using 3/4" x 1" reducing coupling.
See Installation Manual for more details.
• The steam tubelets must face up
regardless of the airflow direction
in the duct. The plate is labeled
“UP” to indicate proper orientation.
• On horizontal duct runs, install the
dispersion tube low in the duct.
On vertical duct runs, center the
tube on the duct. NOTE: If the dispersion tube is mounted on insulated ductwork,
make sure the insulation is not more than 2" thick at tube location.
1
Duct location and
absorption distance
Absorption distance is the unobstructed straight line distance
needed for steam to be fully absorbed.
• Determine absorption distance based on the lowest air
velocity that the system will see (refer to table below).
• Locate dispersion tube in a straight section of duct, far
enough upstream of any obstructions or bends in the duct.
ABSORPTION DISTANCE
Tonnage
per CFM
Recommended
Absorption
Distance
5 ton
2000 CFM 12 inches
10 ton
4000 CFM 6 inches
CENTER
CENTER
Install dispersion tube
1
Install drain line
• Secure 7/8" drain line with the hose clamp provided. Do not over tighten.
• Make sure drain line has a constant downward slope and is not kinked or blocked.
• If floor drain is not available, use condensate pump to route water to a drain.
NOTE: The humidifier uses cold water to temper drain water to less than 140°F.
Water quality and
canister selection
The Steam Humidifier operates on water with conductivity between
75 and 1,250 EC.
• Connect to water supply. Do not use RO or DI water.
• Use cold water only.
WATER QUALITY GUIDELINES
EC (1:1)
Research
Grains/
Gal Hardness
Recommended Canister by Voltage
120VAC 208VAC 240VAC
75-100 0-3 Naturally
Soft
Installation Not
Recommended AS80LC AS80LC
100-300 3-9 Naturally
Soft AS80LC AS80LC AS80LC
300-500 9-15 Slightly
Hard AS80LC AS80 AS80
500-650 15-20 Moderately
Hard AS80LC AS80 AS80
650-850 20-25 Hard AS80LC AS80 AS80
850-1250 25-36 Very Hard AS80LC AS80 AS80
above
1250
above
36
Extremely
Hard Installation Not Recommended
Softened AS80 AS80 AS80
4
5
6
FACTORY SETTING FOR
11.5 AMP NOMINAL OPERATION
RECOMMENDED SETTING
SLIDE DIP SWITCH #1 TO
“ON” POSITION FOR 16.0 AMP
NOMINAL OPERATION
120
LED D8
208 240
120 208 240
Capacity
Settings are chosen based on desired capacity.
STEAM CAPACITY
Amperage Voltage
Maximum
Steam Capacity
(gal/day)
11.5
120V 11.5
208V 20.5
240V 23.3
16.0
(Nominal)
120V 16.0
208V
(recommended) 30.0
240V
(recommended) 34.6
Circuit board dip switches
For max capacity connect to 240V and set dip
switch from 11.5 to 16 Amps.
90-1959
2
5
FEET
NONO
18"
MINIMUM
NO
Determine
location for
humidifier control
Do not mount humidifier control:
• In the flow of supply registers.
• Behind doors or in corners
• In direct light, near lighting fixtures, or other
appliances that give off heat.
• Outside or in unconditioned area.
90-1666
Humidifier
control wiring
WHT / YLW
WHT / BLU
YLW (C)
ORG (NO)
BLU (NC)
RCWGY
Y
G
W
C
R
HUMIDISTAT
TERMINAL
THERMOSTAT
FURNACE
REMOVE
HUMIDFIER
CONTROL
(OPTIONAL)
DUCT SENSOR
ODT
BLOWER
ACTIVATION RELAY
FAN PACK
24
IN
GND
1
2
7
8
12
13
14
1
2
3
4
4851
90-1992
7
8
3
anden.com
P.O. Box 1467
Madison, WI 53701-1467
800.972.3710 F: 608.257.4357
Printed in USA
©2019 Anden – A Quality brand from Research Products Corporation
10014465 B2208632A 12.19
Running and
programming control
The maximum humidity set point is 90% and the control comes
with the default maximum humidity set point preset to 65%. See
step 4 in Program Mode of ADMC manual.
Humidifier control jumper setting:
24VAC EXT.
 Jumper (JP2) on right: 24VAC dry contact when
wiring terminals 7 and 8.
Sequence of
operation
1. Green lights:
a. Solid “on/off” light indicates humidifier is turned on.
b. 1 minute flashing “on/off” light indicates power is
restored to humidifier.
c. Steam light on means steam is being created.
d. Fill light on means water is being added to
humidifier.
e. Drain light on means water is draining from
humidifier.
2. Expected noises from the humidifier:
a. Clicking noise of valve opening to add water.
b. Clicking noise of drain valve opening during the
drain cycle.
c. Clicking noise of the relays opening and closing
during normal operation of the humidifier.
d. Sound of water flowing through the humidifier.
3. Humidistat will call for humidity,
a. Steam light will turn green.
i. Electricity will pass through the water in the
canister unit causing the water to heat to
boiling point, which sends the steam up the
hose.
ii. On startup and steam canister replacement the
water within the canister could take at least 30
minutes to boil and several days to condition
and reach full capacity.
iii. Once the water in the canister is conditioned,
the water will boil almost immediately.
4. Drain valve operation
a. Any time the drain valve is activated, the Drain light
illuminates green.
For additional help
Call Anden Tech Support at 1-800-972-3710. The Quick Start
Guide is to be used as reference only. Installation is to be
in accordance with Installation and Operating Instructions
provided with the dehumidifier.
9
4

This manual suits for next models

1

Other Anden Humidifier manuals

Anden AS35FP User manual

Anden

Anden AS35FP User manual

Anden AS150 User manual

Anden

Anden AS150 User manual

Anden AS35 Series Operating and maintenance instructions

Anden

Anden AS35 Series Operating and maintenance instructions

Popular Humidifier manuals by other brands

Redmond RHF-3302 Instructions for use

Redmond

Redmond RHF-3302 Instructions for use

Brune B 260 operating instructions

Brune

Brune B 260 operating instructions

Panasonic F-VXK70A Service manual

Panasonic

Panasonic F-VXK70A Service manual

Guardian H7500 user manual

Guardian

Guardian H7500 user manual

Carel humiFog RHM Series user manual

Carel

Carel humiFog RHM Series user manual

Devatec ElectroVap ELMC 1 SM CYL Technical manual

Devatec

Devatec ElectroVap ELMC 1 SM CYL Technical manual

Holmes HM295TG user manual

Holmes

Holmes HM295TG user manual

Evenflo 759200 owner's guide

Evenflo

Evenflo 759200 owner's guide

CA.MI HUMI-ROUND instruction manual

CA.MI

CA.MI HUMI-ROUND instruction manual

Clas Ohlson DF-HU0618UC1 manual

Clas Ohlson

Clas Ohlson DF-HU0618UC1 manual

ARESA AR-4201 instruction manual

ARESA

ARESA AR-4201 instruction manual

Crane EE-4109 instruction manual

Crane

Crane EE-4109 instruction manual

Vornado Ultrasonic Vortex Humidifier owner's guide

Vornado

Vornado Ultrasonic Vortex Humidifier owner's guide

Boneco E2641 Instructions for use

Boneco

Boneco E2641 Instructions for use

SOLIS TWIST AIR 7220 user manual

SOLIS

SOLIS TWIST AIR 7220 user manual

Holmes HCM3955 owner's guide

Holmes

Holmes HCM3955 owner's guide

HoMedics UHE-CM180 Instruction manual and  warranty information

HoMedics

HoMedics UHE-CM180 Instruction manual and warranty information

GeneralAire Elite 570 Installation & owner's manual

GeneralAire

GeneralAire Elite 570 Installation & owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.