manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Anden
  6. •
  7. Humidifier
  8. •
  9. Anden AS35FP User manual

Anden AS35FP User manual

Other Anden Humidifier manuals

Anden AS150 User manual

Anden

Anden AS150 User manual

Anden AS35 User manual

Anden

Anden AS35 User manual

Anden AS35 Series Operating and maintenance instructions

Anden

Anden AS35 Series Operating and maintenance instructions

Popular Humidifier manuals by other brands

Scarlett Comfort SC-AH986E22 instruction manual

Scarlett

Scarlett Comfort SC-AH986E22 instruction manual

SOLAC HU1060 Instructions for use

SOLAC

SOLAC HU1060 Instructions for use

Vicks FilterFree use and care manual

Vicks

Vicks FilterFree use and care manual

Philips HU4902 quick start guide

Philips

Philips HU4902 quick start guide

Bionaire CM1 Instruction leaflet

Bionaire

Bionaire CM1 Instruction leaflet

Air-O-Swiss AOS 7131 Instructions for use manual

Air-O-Swiss

Air-O-Swiss AOS 7131 Instructions for use manual

Vitek VT-1768 BK Manual instruction

Vitek

Vitek VT-1768 BK Manual instruction

KING K 5002 Rainbow instruction manual

KING

KING K 5002 Rainbow instruction manual

Crane EE-6902 instruction manual

Crane

Crane EE-6902 instruction manual

Glaziar Ness user manual

Glaziar

Glaziar Ness user manual

Philips DreamStation Go Faqs

Philips

Philips DreamStation Go Faqs

Honeywell MISTMATE HUL520BC manual

Honeywell

Honeywell MISTMATE HUL520BC manual

Stadler Form Hera Operation instructions

Stadler Form

Stadler Form Hera Operation instructions

Hunter 31206 owner's guide

Hunter

Hunter 31206 owner's guide

TaoTronics TT-AH004 user guide

TaoTronics

TaoTronics TT-AH004 user guide

adorini Cigar Heaven manual

adorini

adorini Cigar Heaven manual

Aprilaire 800 Series user manual

Aprilaire

Aprilaire 800 Series user manual

Pyle SereneLife PHUMDIF8 Instruction book

Pyle

Pyle SereneLife PHUMDIF8 Instruction book

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INTERNAL WALL 24"
16" MINIMUM
FOR STEAM HOSE
FAN
PACK
STEAM
HUMIDIFIER
DRAIN
GROW
LIGHT
GROW
LIGHT
2 FEET
MINIMUM TO
SIDE WALL
1-1/2 FEET
MINIMUM TO CEILING
ALLOW A
3 TO 5 FOOT
PATH FOR THE
STEAM TO DISSIPATE
DEPENDING ON
TEMPERATURE
AS35FP Steam Humidifier
Quick Start Guide
Choose a location in a
conditioned space
Install drain line
• Secure 7/8" drain line with the hose clamp provided. Do not over tighten.
• Make sure drain line has a constant downward slope and is not kinked
or blocked.
• If floor drain is not available, use condensate pump to route water to a drain.
NOTE: The humidifier uses cold water to temper drain water to less than 140°F.
1
3
90-2196
Fan pack location
The fan pack has a set fan speed, the fan blows
over the steam outlet to help the steam absorb
into the surrounding air. See the figure above for
placement guidance. Install the fan pack such that
steam is dispersed above canopy height.
2
1
Water quality and canister selection
The Steam Humidifier operates on water with conductivity between 75 and 1,250 EC.
• Connect to water supply. Do not use RO or DI water.
• Use cold water only.
WATER QUALITY GUIDELINES
EC (1:1) Research Grains/Gal Hardness
Recommended Canister by Voltage
120VAC 208VAC 240VAC
75-100 0-3 Naturally Soft Installation Not Recommended AS80LC AS80LC
100-300 3-9 Naturally Soft AS80LC AS80LC AS80LC
300-500 9-15 Slightly Hard AS80LC AS80 AS80
500-650 15-20 Moderately Hard AS80LC AS80 AS80
650-850 20-25 Hard AS80LC AS80 AS80
850-1250 25-36 Very Hard AS80LC AS80 AS80
above 1250 above 36 Extremely Hard Installation Not Recommended
Softened AS80 AS80 AS80
4
5
FACTORY SETTING FOR
11.5 AMP NOMINAL OPERATION
RECOMMENDED SETTING
SLIDE DIP SWITCH #1 TO “ON” POSITION
FOR 16.0 AMP NOMINAL OPERATION
120
LED D8
208 240
120 208 240
Capacity
Settings are chosen based on desired capacity.
STEAM CAPACITY
Amperage Voltage Maximum Steam Capacity (gal/day)
11.5
120V 11.5
208V 20.5
240V 23.3
16.0
(Nominal)
120V 16.0
208V
(recommended) 30.0
240V
(recommended) 34.6
Circuit board dip switches
For max capacity connect to 240V and set dip switch from 11.5 to 16 Amps.
90-1959
2
5
FEET
NONO
18"
MINIMUM
NO
6
90-1666
Determine location
for humidifier control
Do not mount humidifier control:
• In the flow of supply registers.
• Behind doors or in corners
• In direct light, near lighting fixtures, or other
appliances that give off heat.
• Outside or in unconditioned area.
Humidifier control wiring
7
ANDEN MODEL AS35FP
STEAM HUMIDIFIER
MODEL 5558
HUMIDIFIER
CONTROL
ODT
CIRCUIT
BOARD
HUMIDISTAT
TRANSFORMER
FAN PACK
FAN PACK
24VAC
P4
YELLOW
BLUE
BLUE
YELLOW
WHITE
RED
1
2
1
2
6
12
13
14
7
8
NOTE:
DIGITAL OUTPUT SIGNAL
SELECTOR JUMPER (JP2) MUST BE ON
RIGHT (DRY CONTACT) POSITION OR
THE HUMIDIFIER WILL BE DAMAGED.
90-2349
Running and
programming
control
The maximum humidity set point is 90%
and the control comes with the default
maximum humidity set point preset to
65%. See step 4 in Program Mode of
ADMC manual.
Humidifier control jumper setting:
24VAC EXT.
Jumper (JP2) on right: 24VAC dry
contact when wiring terminals 7 and 8.
8
3
anden.com
P.O. Box 1467
Madison, WI 53701-1467
800.972.3710 F: 608.257.4357
Printed in USA
©2020 Anden – A Quality brand from Research Products Corporation
10014466 B2208633A 1.20
Sequence of operation
1. Green lights:
a. Solid “on/off” light indicates humidifier is turned on.
b. 1 minute flashing “on/off” light indicates power is restored
to humidifier.
c. Steam light on means steam is being created.
d. Fill light on means water is being added to humidifier.
e. Drain light on means water is draining from humidifier.
2. Expected noises from the humidifier:
a. Clicking noise of valve opening to add water.
b. Clicking noise of drain valve opening during the drain cycle.
c. Clicking noise of the relays opening and closing during
normal operation of the humidifier.
d. Sound of water flowing through the humidifier.
3. Humidistat will call for humidity,
a. Steam light will turn green.
i. Electricity will pass through the water in the canister
unit causing the water to heat to boiling point, which
sends the steam up the hose.
ii. On startup and steam canister replacement the water
within the canister could take at least 30 minutes
to boil and several days to condition and reach full
capacity.
iii. Once the water in the canister is conditioned, the water
will boil almost immediately.
4. Drain valve operation
a. Any time the drain valve is activated, the Drain light
illuminates green.
For additional help
Call Anden Tech Support at 1-800-972-3710. The Quick
Start Guide is to be used as reference only. Installation
is to be in accordance with Installation and Operating
Instructions provided with the dehumidifier.
4