manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Antelope
  6. •
  7. Amplifier
  8. •
  9. Antelope Isochrone DA User manual

Antelope Isochrone DA User manual

Other Antelope Amplifier manuals

Antelope Discrete 4 User manual

Antelope

Antelope Discrete 4 User manual

Antelope MP8d User manual

Antelope

Antelope MP8d User manual

Antelope ZEO User manual

Antelope

Antelope ZEO User manual

Antelope MP32 User manual

Antelope

Antelope MP32 User manual

Antelope MP32 User manual

Antelope

Antelope MP32 User manual

Popular Amplifier manuals by other brands

Magnat Audio EDITION FOUR Owner's manual/warranty document

Magnat Audio

Magnat Audio EDITION FOUR Owner's manual/warranty document

Inter-m PA-2000A Operation manual

Inter-m

Inter-m PA-2000A Operation manual

Yamaha TX6n owner's manual

Yamaha

Yamaha TX6n owner's manual

Peavey TNT 150 user guide

Peavey

Peavey TNT 150 user guide

Bosch LBB 1903/10 Installation and user instructions

Bosch

Bosch LBB 1903/10 Installation and user instructions

Avocent Emerge DA1200D Installer/user guide

Avocent

Avocent Emerge DA1200D Installer/user guide

Redgum RGi35 operating instructions

Redgum

Redgum RGi35 operating instructions

Cambridge Audio AXA25 user manual

Cambridge Audio

Cambridge Audio AXA25 user manual

Alpine MRP-M200 owner's manual

Alpine

Alpine MRP-M200 owner's manual

Technical Pro H1502UrBT user manual

Technical Pro

Technical Pro H1502UrBT user manual

FMS EMGZ307 operating manual

FMS

FMS EMGZ307 operating manual

Racal Instruments 5601 user manual

Racal Instruments

Racal Instruments 5601 user manual

Valcom V-1094A Technical specifications

Valcom

Valcom V-1094A Technical specifications

Cambridge Audio 851D user manual

Cambridge Audio

Cambridge Audio 851D user manual

QSC 3800 Specifications

QSC

QSC 3800 Specifications

NAD C300 owner's manual

NAD

NAD C300 owner's manual

Rotel RMB-1077 owner's manual

Rotel

Rotel RMB-1077 owner's manual

Peavey Monitor 300 Series operating guide

Peavey

Peavey Monitor 300 Series operating guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Getting Started:
It takes only seconds to harness the benefits of the Isochrone OCX.
Integrating the Isochrone DA into the studio environment couldn't be easier.
Connect the AC input to a power outlet
Connect the master sync device to a corresponding sync input on the on DA's rear
panel. Set the SOURCE knob on front to the input receiving incoming clock.
Connect any devices you want synced to the appropriate outputs on the DA's rear
panel.
Power the DA on via the power button on the front panel. Verify that both the LOCK
and SIGNAL leds are lit.
The DA is now distributing regenerated, low jitter clock to connected devices. Some
devices will automatically sync to clock provided by the DA. Other devices may require
additional configuration in order to utilize this incoming clock.
Note: When making initial connections, do so with the studio volume turned down.
Some devices may emit unpleasant sound until properly configured to accept incoming
clock.
1
2
3
4
5
There should only be one master clock in your studio synchronizing all your gear.
Attempting to daisy-chain your master clock signal through multiple devices will only
result in sync problems like clicks and pops or jitter-colored digital sound. This is where
the Isochrone DA comes to the rescue by providing a large number of buffered outputs,
so you can feed the the master clock to all of your gear individually.
It is not enough to simply distribute the clock signal. Passive sync distribution may end up
redistributing harmful jitter to all your devices. Unlike other DA products, Isochrone DA is
an active distributer; it completely regenerates the clock, always distributing jitter-free
signal throughout your facility.
Front Panel
Power Switch
Source Selector
Designates which input receives the clock distributed to the DA outputs.
Lock and Signal LEDs
When the Signal LED is lit, it verifies that the input chosen by the Source Selector is
receiving clock. The Lock LED verifies that the DA is properly locked to the incoming
clock, and the incoming clock is at a supported frequency (30 kHz- 202 kHz).
Frequency Display
Displays the sample rate received & distributed by the DA.
Contrast Knob
Adjusts the frequency display contrast.
1
2
3
4
5
1234566
Front Panel
6Alternate Sample Rate Selector for Word Clock outputs 7 and 8.
Word clock outputs 7 and 8 are capable of outputting frequencies different from the clock
received by the DA. The first five settings select frequencies that are multiples of the
incoming clock. The final setting, 256 WC, configures the corresponding output to generate
256 FS Clock (sometimes referred to as Superclock), a protocol used by some Digidesign
components.
A red LED is present above each knob. When lit, it indicates that a valid sample rate is
selected. When flashing, the output has been configured to output at a frequency outside
the supported range (32kHz- 192 kHz).
For easy reference, the following chart indicates what frequencies outputs 7 and/or 8
transmit depending on incoming sample rate and knob settings. Although the DA can
receive any frequency between 30kHz and 202 kHz, this chart is limited to those most
commonly used.
32 kHz
44.1 kHz
48 kHz
88.2 kHz
96 kHz
176.4 kHz
192 kHz
X
X
X
X
X
44.1 kHz
48 kHz
WC / 4
X
X
X
88.2 kHz
96 kHz
44.1 kHz
48 kHz
WC /2
32 kHz
44.1 kHz
48 kHz
88.2 kHz
96 kHz
176.4 kHz
192 kHz
WC
X
X
88.2 kHz
64 kHz
96 kHz
176.4 kHz
192 kHz
2 WC
X X
X
X
X
X
X
X
176.4 kHz
128 kHz
192 kHz
4 WC
256 fs
256 fs
256 fs
256 WC
ALTERNATE SAMPLE RATE
SAMPLE RATE
X Output is not valid
Rear Panel
10ft. (3m.).
Power Connection
This IES AC connection accepts an input of 95-245 VAC 50/60 Hz. As a result, the OCX
automatically accommodates a full range of voltages, allowing safe use in any country.
S/PDIF input and S/PDIF thru
The S/PDIF in is an RCA connection that accepts clock via Coaxial S/PDIF The S/PDIF thru
will reamplify and output any audio contained in signal received by the S/PDIF input.
AES/EBU input and AES/EBU thru
The AES/EBU in is an XLR connection that accepts clock via AES/EBU The AES/EBU thru
will reamplify and output any audio contained in signal received by the AES/EBU input.
Word Clock input 1 and 2
BNC connections used to accept clock for distribution.
Word Clock outputs 1-6
The sample rate provided by these outputs always matches the sample rate indicated by
the Frequency Display on the front panel.
Word Clock outputs 7-8 The sample rate provided by these two outputs can either
match the sample rate of outputs 1-6, or can be changed to alternate sample rates by using
their corresponding knobs on the front panel.
AES/EBU outputs
Output clock to devices with AES / EBU inputs.
S/PDIF outputs
Output clock to devices with S/PDIF inputs.
Maximum Cable lengths:
Too long of a cable run can cause unwanted jitter and clock error. For optimum results,
Word Clock cables should be no longer than 20ft. (6m.), AES/EBU no longer than 300ft.
(90m.), and S/PDIF no longer than
7
8
9
10
11
11
12
13
78910 11 11 12 13
Rear Panel