CPIN002679
4
If you are still experiencing reception problems after installation, please refer to the
trouble-shooting guide below
Problems with Digital TV Reception
Unlike analogue terrestrial television, it is not possible to view digital channel under weak signal
strength conditions. Therefore, typically you will either receive digital channels with a clear picture and
sound or you will not receive any channels at all.
Insufficient digital signal can cause occasional blocking, freezing or complete loss of picture. Some roof
antennas may not be suitable for digital terrestrial television. Ensure that you have fitted a suitable
antenna to help improve signal quality to a suitable level for clear digital reception. Further check that
all connections & cable from antenna to receiver are good quality, secure and clean.
Blocking, freezing or complete loss of picture can also occur when a digital signal is too strong.
Adjusting the gain control knob until the picture improves may help.
TROUBLE SHOOTING
© This instruction leaflet is subject to copyright and must not be reproduced, copied or otherwise used in any
way or for any purpose without the consent in writing of the owner
Warranty
Arlec guarantees this product in accordance with the Australian Consumer Law.
Arlec also warrants to the original first purchaser of this product (“you”) from a retailer that this product will be free of defects in materials and
workmanship for a period of 12 months from the date of purchase; provided the product is not used other than for the purpose, or in a manner
not within the scope of the recommendations and limitations, specified by Arlec, is new and not damaged at the time of purchase, has not been
subjected to abuse, misuse, neglect or damage, has not been modified or repaired without the approval of Arlec and has not been used for
commercial purposes (“Warranty”).
If you wish to claim on the Warranty, you must, at your own expense, return the product, and provide proof of original purchase and your name,
address and telephone number, to Arlec at the address below or the retailer from whom you originally purchased the product within 12 months
from the date of purchase.
Arlec will (or authorise the retailer to) assess any claim you may make on the Warranty in the above manner and if, in Arlec’s reasonable opinion,
the Warranty applies, Arlec will at its own option and expense (or authorise the retailer to) replace the product with the same or similar product or
repair the product and return it to you or refund the price you paid for the product. Arlec will bear its own expenses of doing those things, and you
must bear any other expenses of claiming on the Warranty.
The Warranty is in addition to other rights and remedies you may have under a law in relation to the product to which the Warranty relates.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for
a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or
replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Arlec Australia Pty. Ltd. ACN 009 322 105 (“Arlec”) gives the Warranty.
Arlec’s telephone number, address and email address are:
Customer Service: (03) 9982 5111
Building 3, 31 – 41 Joseph Street, Blackburn North, Victoria, 3130
Blackburn North LPO, P.O. Box 1065, Blackburn North, 3130
Email: [email protected]
ANTSIG is proudly produced by ARLEC Australia Pty. Ltd.
Visit us at: www.ANTSIG.com
CPIN002679
AMPLIFIER
AntEnnA DIStRIBUtIOn
AP862 AP864 AP868
2 WAY
DISTRIBUTION
AMPLIFIER
4 WAY
DISTRIBUTION
AMPLIFIER
8 WAY
DISTRIBUTION
AMPLIFIER
Fig.02
Fig.01
LED CONFIGURATION
Surge Protection
Red Light: Surge protection has
been activated
When the surge protection red
light comes on, it shows that a
power surge or spike has happened
and the surge protection has been
activated. this will return to normal
and will require no action by
yourself. Wait until the power surge
or spike passes and the red light
goes out. This feature ensures that
you have that extra protection and
piece of mind.
No Light: Normal operation
Power Light
Green when power on
Short Protection
Red Light: Short is detected
When the short protection red
light comes on, it shows a short has
been detected. To check, disconnect
each cable one at a time from the
distribution amplifier until the light
turns green. You can follow that line
until you find the short. (Typically
newly terminated cables).
Green Light: Normal operation
TECHNICAL SPECIFICATIONS
Product Code AP862 AP864 AP868
Inputs 2 2 2
Outputs 2 4 8
Frequency Range
UHF Input (MHz) 520-820 520-820 520-820
Frequency Range
VHF/UHF Input (MHz) 40-820 40-820 40-820
Max Output Level 90dBµV 87dBµV 87dBµV
Gain Per Split 12dB 10dB 10dB
Noise <4dB <4dB <4dB
Isolation Loss 22dB 22dB 22dB
Weight 440g 517g 750g
FEATURES
• Dedicated inputs for UHF and
VHF/UHF combination
• Side mounted terminals provide
easy cable management
• Short protection indicator
• Gain Control
• Surge protection
• Full Digital compatibility for HDTV
• Designed for amplication of digital
TV signals
IDENTIFICATION
GAIN ADJUSTMENT FEATURE
A TYPICAL INSTALLATION
Distribution amplifier can be used with indoor or outdoor antennas, typically installed within your roof
cavity. The “UHF” only input is for UHF only antennas, ie. those not receiving VHF.
Option 1:
Your distribution amplifier can be placed in roof cavity for multiple TV outlets.
Option 2:
It can be placed next to TV to split your wallplate signal or indoor antenna signal between
multiple devises located together. This allows more control over the split signal.
A gain control knob has been incorporated to allow for more
control over the amplified signal level. When setting up your
distribution amplifier begin with the control knob in the
minimum level position and increase until good picture can
be seen.
NOTE: Too much
gain can cause
similar problems to
insufficient signals.
32
INTRODUCTION
Thank you for purchasing the Distribution Amplifier.
Please keep this manual in a safe place for future reference.
This range of antenna amplifiers from Antsig is designed
to improve reception quality by amplifying weak UHF and
VHF signals and distributing the signal to multiple locations
around the home. They can also be used to distribute VCR,
Digital Television and Satellite TV signals around the home
without loss of signal strength.
Designed with style, sophistication and quality in mind,
this range is the preferred choice for both the professional
antenna installer and the home user wanting to get the very
best performance from their AV equipment.
We have integrated the very latest technology, the very best
in Australia designed product styling and highest levels of
safety to produce a class-leading product.
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
DISTRIBUTION AMP
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
LED POWER ON
INDICATOR
LED SHORT
PROTECTION
INDICATOR
LED SURGE
PROTECTION
INDICATOR
TV OUTPUT
TV
TO OTHER TV
DISTRIBUTION AMPLIFIER
UHF ANTENNA
VHF/UHF ANTENNA
COAXIAL CABLE
COAXIAL CABLE
PVR OR RADIO
VHF/UHF
ANTENNA INPUT
UHF ANTENNA
INPUT
RECORDER
OUTPUT
(PVR OR RADIO)
DISTRIBUTION AMPLIFIER
MUST BE INSTALLED WITHIN
ROOF CAVITY AS SHOWN
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
TV
DISTRIBUTION AMPLIFIER
WALL PLATE
INDOOR ANTENNA
OR
COAXIAL CABLE
COAXIAL CABLE
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
DISTRIBUTION AMP
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
LED POWER ON
INDICATOR
LED SHORT
PROTECTION
INDICATOR
LED SURGE
PROTECTION
INDICATOR
TV OUTPUT
TV
TO OTHER TV
DISTRIBUTION AMPLIFIER
UHF ANTENNA
VHF/UHF ANTENNA
COAXIAL CABLE
COAXIAL CABLE
PVR OR RADIO
VHF/UHF
ANTENNA INPUT
UHF ANTENNA
INPUT
RECORDER
OUTPUT
(PVR OR RADIO)
DISTRIBUTION AMPLIFIER
MUST BE INSTALLED WITHIN
ROOF CAVITY AS SHOWN
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
TV
DISTRIBUTION AMPLIFIER
WALL PLATE
INDOOR ANTENNA
OR
COAXIAL CABLE
COAXIAL CABLE
SURGEPROTECTION
POWER
SHORTPROTECTION
TV1 TV2
VHF/UHF UHF
DISTRIBUTION AMP
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
LED POWER ON
INDICATOR
LED SHORT
PROTECTION
INDICATOR
LED SURGE
PROTECTION
INDICATOR
TV OUTPUT
TV
TO OTHER TV
DISTRIBUTION AMPLIFIER
UHF ANTENNA
VHF/UHF ANTENNA
COAXIAL CABLE
COAXIAL CABLE
PVR OR RADIO
VHF/UHF
ANTENNA INPUT
UHF ANTENNA
INPUT
RECORDER
OUTPUT
(PVR OR RADIO)
DISTRIBUTION AMPLIFIER
MUST BE INSTALLED WITHIN
ROOF CAVITY AS SHOWN
SURGEPROTECTION
POWER
SHORTPROTECTION
TV1 TV2
VHF/UHF UHF
TV
DISTRIBUTION AMPLIFIER
WALL PLATE
INDOOR ANTENNA
OR
COAXIAL CABLE
COAXIAL CABLE
SURGEPROTECTION
POWER
SHORTPROTECTION
TV1 TV2
VHF/UHF UHF
DISTRIBUTION AMP
SURGE PROTECTION
POWER
SHORT PROTECTION
TV1 TV2
VHF/UHF UHF
LED POWER ON
INDICATOR
LED SHORT
PROTECTION
INDICATOR
LED SURGE
PROTECTION
INDICATOR
TV OUTPUT
TV
TO OTHER TV
DISTRIBUTION AMPLIFIER
UHF ANTENNA
VHF/UHF ANTENNA
COAXIAL CABLE
COAXIAL CABLE
PVR OR RADIO
VHF/UHF
ANTENNA INPUT
UHF ANTENNA
INPUT
RECORDER
OUTPUT
(PVR OR RADIO)
DISTRIBUTION AMPLIFIER
MUST BE INSTALLED WITHIN
ROOF CAVITY AS SHOWN
SURGEPROTECTION
POWER
SHORTPROTECTION
TV1 TV2
VHF/UHF UHF
TV
DISTRIBUTION AMPLIFIER
WALL PLATE
INDOOR ANTENNA
OR
COAXIAL CABLE
COAXIAL CABLE
SAFETY INFORMATION
• The product is designed for indoor use only.
• The mains wall socket must remain readily accessible.
• The product is not disconnected from mains unless
supply plug is removed.

This manual suits for next models

2

Other Antsig Amplifier manuals

Antsig AP700 User manual

Antsig

Antsig AP700 User manual

Antsig AP861 User manual

Antsig

Antsig AP861 User manual

Popular Amplifier manuals by other brands

Ultrasound PRO-200 owner's guide

Ultrasound

Ultrasound PRO-200 owner's guide

Executive Audio ALPHA Series user manual

Executive Audio

Executive Audio ALPHA Series user manual

Onkyo TX28 Service manual

Onkyo

Onkyo TX28 Service manual

Burmester 077 owner's manual

Burmester

Burmester 077 owner's manual

Burson PC-160 user manual

Burson

Burson PC-160 user manual

Pioneer GM-X542 owner's manual

Pioneer

Pioneer GM-X542 owner's manual

Kustom HV 20T owner's manual

Kustom

Kustom HV 20T owner's manual

NAD 306 Specification sheet

NAD

NAD 306 Specification sheet

Kramer VP-8K-b manual

Kramer

Kramer VP-8K-b manual

Perreaux SM2 manual

Perreaux

Perreaux SM2 manual

Quest Engineering PR Series owner's manual

Quest Engineering

Quest Engineering PR Series owner's manual

Yamaha P1150 Service manual

Yamaha

Yamaha P1150 Service manual

Hayden HGT-A user manual

Hayden

Hayden HGT-A user manual

Denon PMA-710AE user manual

Denon

Denon PMA-710AE user manual

DAPAudio HP-2100 manual

DAPAudio

DAPAudio HP-2100 manual

NAD 116 Service manual

NAD

NAD 116 Service manual

Softel SPA Series manual

Softel

Softel SPA Series manual

ADJ V3001 Plus Service manual

ADJ

ADJ V3001 Plus Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.