Anyload 805HP User manual

805HP
Handheld Digital Weight Indicator
User’s Manual (v1703)
Anyload Transducer Co. Ltd
Website: www.anyload.com
Email: info@anyload.com

TABLE OF CONTENTS
1. Introductions and Features 2
2. Safety Recommendations 2
3. Display Icon List 3
4. Keys 4
5. Work Mode 5
6. Start Up and adjust 6
6.1 Battery Installation 6
6.2 Indicator Dimensions 7
6.3 Connection Diagrams 8
7. Weighing Modes 7
7.1 Normal Weighing Mode 7
7.2 Gross/Net Mode 8
7.3 Peak Mode 10
7.4 Cumulate Mode 11
7.5 Calibration Mode 12
8. Configurations and Menu Operations 13
8.1 Menu Operations 13
8.2 Overload 17
8.3 Modify Password 18
9. Communication 19
9.1 RS232 Communication 19
9.2 Wireless Communication 20
10. Calibration and Parameter Settings 21
10.1Standard Value Calibration 22
10.2 Digit Calibration 24
11. Troubleshooting Guides 26
12. Technical Specifications 27
13. Appendices 29
1 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

1. Introductions and Features
Thank you for choosing Anyload 805HP Handheld Digital Weight Indicator.
The 805HP hand held digital weight indicator is a general purpose and durable
indicator that provides high accuracy, reliability and multiple functions. The
805HP can drive up to eight 350Ω or thirty two 1000Ω load cells. With an IP65
ABS wash down enclosure, the 805HP digital weighing indicator is ideal for use
in Transportation, Entertainment, Aerospace, Military, Food and Agricultural
industry.
Key Features include:
Exceptionally long battery life ( 3-AA batteries )
LED backlight and panoramic FSTN LCD view angle
Material: ABS
IP Rating: IP65
LCD 6-digit display with LED backlight
Non-volatile memory for reliable date saving
Units of Measurement: kg, g, t, lb, Klb, N, kN, oz, user-
defined unit
Configurable 21 set-points for precaution and warning
User-selectable display interval
Overloading recording
10 user-selectable analog-to-digital converting frequency
Weight calibration and digital calibration
User-selectable auto power-off and power-saving timing
Functions: Auto-Zero Tracking, Auto-Zero, Manual-Zero,
Hold, Peak-Hold, TARE
This manual provides installation, operation and configuration information of
805HP indicator. It is recommended to go through the manual in details before
installing, operating or configuring the indicator.
2. Safety Recommendations
Important instructions which involve safety are highlighted with the
appropriate mark:
2 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

When it is required to work inside the indicator enclosure for some
procedures described, the work can only be performed by qualified technical
personnel.
3. Display Icon List
Icon
Meaning
805HP Battery Power indicator
Peak hold mode
Weights saved to memory
Tare value acquired
Gross weight mode
Cumulate Mode
Scale is zeroed
Wireless signal strength
Load cell battery power indicator
Weight exceeded the maximum capacity “overload warning
value “signal
Signal stability
There are hidden figures which can be shown on the
following page
3 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

Refer to Section 13 (Appendices) for detailed on alphanumeric symbols.
( Appendix 13.1-Seven Segment digital display alphanumeric table )
4. Keys
4.1 Key List
Key
Functions
Power Button
Tare; Down key
Unit; Left key
Zero; Up key; Return key
Peak; Right key
Cumulate; Enter key
4 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

4.2 Key Instructions for all weighing modes
Buttons
Press
Duration
Modes
Normal
Peak
Cumulate
【SWITCH】
Short press
(0.5 sec)
Long press
(2 sec)
Turn Off
Turn Off
Turn Off
【
CUMULATE
】
Short press
(0.5 sec)
Accumulate
(Add weight to
memory)
Long press
(2 sec)
Show
cumulative
value
Show
cumulative
value
Exit cumulate
mode
【ZERO】
Short press
(0.5 sec)
Zero the scale
Long press
(2 sec)
Clear
Cumulative
value
【HOLD】
Short press
(0.5 sec)
Holding/
Cancel
Clear Peak
Value
Long press
(2 sec)
Go to Peak
Mode
Return to
Normal
Weighing
Mode
【TARE】
Short press
(0.5 sec)
Tare/Untare
Long press
(2 sec)
Gross/Net
Weight
Gross/Net
Weight
【
UNITS
】
Short press
(0.5 sec)
Switch units
Switch units
Long press
(2 sec)
5 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

5. Work Modes
5.1 Overview
Operation mode
Function
Power-off
When the indicator is turned off, date will be saved in
non-volatile memory.
Operation mode
When the indicator enters wake-up mode, all functions
are enabled and the power run dynamically.
Power-saving
When LCD is on and backlight is off, the RS-232 circuit
is off.
5.2 Operation Mode Switching Diagram
6 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

6. Start Up and Adjust
6.1 Battery Installation
Open the battery compartment cover and install the battery as shown in figure
below.
Note: Remove the battery when indicator will not be used for a long period.
Start up - After installing the battery, long press the on/off button
for 2-3 seconds then release it. The indicator will beep and the screen
shows initialization until reached to indicator weighing system.
Power off: Long press on/off button for 2-3 seconds then release
it. The screen shows OFF, the indicator is turning off.
7 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

6.2 Indicator Dimensions
(Unit)
H
H1
H2
L
L1
L2
L3
W
Inches
6.7
1.1
0.5
3.9
2.8
0.6
3.2
1.3
mm
170
27
13
98
72
15
80
34
8 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

6.3 Connection Diagrams
6.3.1 805HP Wired Model
Connect load cell (communication & printer) to 805HP according
to the following connection diagram:
9 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

6.3.2 805HP Wireless Model
The indicator is set to match the corresponding wireless transceiver of a
wireless scale. Usually 805HP-WL wireless model is paired with Anyload 110RH-
WL TENSLINK scale or 110ES-WL Salt Waterproof scale. If you need to change
the indicator’s wireless configurations due to radio frequency interference, you
can configure the communication parameters with the following steps in
Section 9.2- Wireless Communication of this manual.
7. Weighing Modes
The indicator has three (3) weighing modes namely, Normal Mode, Cumulate
Mode and Peak Mode. The indicator will automatically set to Normal Mode
upon starting it up. Usually it will be zeroed automatically when it is within the
20% of the full range zero range.
7.1 Normal Weighing Mode
Normal Mode is the most common application in weighing mode which is
enabled by default in the indicator. This mode meets most of the weighing
requirements. The Normal Mode is the real-time feedback and the accurate
weighing.
When indicator is set to the Normal Weighing mode, (Peak mark) will
not appear in the display
7.1.1 Basic Operations in Normal Weighing Mode
I. Zero the Scale
Remove the loads from the scale and wait until [Stable mark] appears. The
scale should not in Tare mode and [Gross weight mark] is on. Press ↑
【ZERO】and (Zero mark) appears. Zero the scale setting is completed.
10 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

II. Acquire Tare Value
When no Tare is stored [Tare mark] does not appear. Place the load on the scale
and wait until (Stable mark) appears. Press ↓【TARE】, the tare weight will be
stored. The display is in Net weight when (Tare mark) is displayed and (Gross
weight mark) is off.
III. Remove Stored Tare Value
When indicator has stored tare weight value other than 0, [Tare mark] appears.
Press ↓【Tare】to remove the stored tare weight value. The display is in Gross
weight mode when (Tare mark) is off.
7.2 Gross/Net Mode
When tare weight is stored (indicator has stored tare weight value other
than 0), press ↓【TARE】to change from net weight to gross weight or
vice versa.
(Gross Weight mark) appears if it is in gross weight mode.
(Gross Weight mark) disappears if it is in net weight mode.
7.3 Peak Mode
Peak Mode is a weighing mode which indicator shows and hold the peak weight
value In the process of weighing. This mode is typically applied to a system
when recording the peak reading of weights.
To activate Peak Weighing Mode, long press →【HOLD】and (Peak mark)
appears
11 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

I. Peak/Normal Weighing Mode
When (Peak mark) appears, peak mode is activated. The display always shows
the maximum value of load which has been applied to the load cell. When the
load is removed, the display still shows the peak load. When (Peak mark)
disappears, peak mode is deactivated. The value shown on display changes
according to the load applied to the load cell. Long press the →【HOLD】can
change the indicator from Peak mode to Normal Weighing mode, or vice versa.
II. Remove Peak Mode Value
When Peak mode is on, [Peak mark] appears. Remove the load and short press
the → 【HOLD】button. The Peak mode value is removed and indicator will
start another Peak mode operation.
7.4 Cumulate Mode
Cumulate Mode is a special function added under the normal weighing mode. In
this mode, the indicator saves weight readings into memory and previews the
accumulated weight value for all saved weight readings. Both real-time
feedback weighing data can also check the cumulative weighing value.
I. How to cumulate weighing values?
Only and during in the normal weighing mode and if the indicator reading is
more than zero or when the weight has been tared, short press to record
the current weight data. Indicator shows as follows:
The recently saved weight readings will be displayed in the screen after 1
second. The M+ sign appears in the lower left corner of the screen. This means
that weight data are recorded and be accumulated.
12 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

II.How to view the cumulative value?
Long press the and it shows the cumulative value. The sign appears In
the middle of the screen. Indicator shows as follows:
Long press , indicator changes from Cumulate to Normal weighing mode
or peak mode, or vice versa.
III.Gross/Net Mode
Press ↓【TARE】, the indicator changes from Gross mode to Net mode, or vice
versa.
Display shows total gross weight value - (Gross Weight mark) is on.
Display shows total net weight value - (Gross Weight mark) is off.
IV. Clear Cumulative Value
Long press ↑【ZERO】,the total gross weight value and total net weight
value will be cleared
7.5 Calibration Mode
In this mode, you have to enter the menu and parameter settings module.
(Refer to Section 10 for the Calibration of the scale system)
13 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

8. Configurations and Menu Operations
8.1 Menu Operations
I. Menu Settings
II. Menu Operations
Entering the menu :
Press at the same time for 1-2 seconds, the indicator will show the
password interface:
Short press or →Choosing digit
Short press →Increasing the numerical value of the digit
Short press →Decreasing the numerical value of the digit
Adjusting the screen till shows required password, and short press to enter
the menu.
The default password is: P00805.
14 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

III. Menu Layout Structure and Navigation key operation
IV. Menu Structure and Parameter Description
There are 4 directional keys ←,→,↑,↓to be used for the operation. ←,→ are
used for horizontal movement in the same level menu and parameters. ↑,↓are
used for moving up and down through different level menus.
Use ←,→ to choose a parameter in a menu and use↓ to move to the next level
menu or parameter.
When moving into a parameter of a menu, the indicator shows the previous
choice.
If you want to change the parameter values, use ↙ to move into the parameter
change status. When the parameter of a menu is a fixed value, use←,→ to
move horizontally. Use ↙ to store the selected parameter and to return to the
last menu.
When a parameter value of a menu is editable, directional keys ←,→ are used
to edit the digit selected, directional keys ↑,↓ are used to increase and
decrease the value of the selected digit. Press ↙ to save the input values and
exit
In the actual menu structure, the selected menu item is displayed horizontally.
The parameter value with the symbol〔〕is the default value of system reset.
15 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

16 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

17 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

8.2 Overload
I. Records Overload
1. This indicator records the real time overload situation. When load weight
exceeds the overload alarm set value, the background light flashes (if
background light is enabled), the panel shows (warning), the display
flashes, and shows the error message
2. When load weight exceeds the overload alarm set value, the background
light flashes (if background light is enabled), the panel shows (warning
signs), the display flashes, shows the error message , and the
buzzer warns intermittently
3. If, overload weight exceeds the historical maximum overload weight, the
historical maximum overload weight will be updated. You can find the
maximum overload in the menu.
18 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)

8.3 Modify Password
Press the ↑, ↓ key, and hold for 1 second, indicator pops up the password
interface.
Press the arrow keys ←, →, ↑, ↓ Enter the password 08050, then press ↙ key
Display shows the password menu (PWORD). Press ↓ to enter.
The first parameter is the user's password (USER P), press ↓ to enter, display
the current password, for example . Note that the password is
effective only within five-digital, one hundred thousand digits will be discarded.
Press ↙ key to start modification, press the arrow keys ←, →, ↑, ↓ enter the
new password, press ↙ key again to save, press ↑ key to return to the previous
menu. Details are as follows:
19 | ANYLOAD 805HP Handheld Digital Weighing Indicator User’s Manual (V1703)
Other manuals for 805HP
2
Table of contents
Popular Touch Panel manuals by other brands

Lenze
Lenze EPM-H520 operating instructions

SperryMarine
SperryMarine Rudder Angle Indicator System Operation, Installaion and Service Manual

Manta
Manta MM263 user manual

3M
3M MicroTouch Near Field Imaging (NFI) Integration guide

Protech Systems
Protech Systems SP-7155 Quick reference guide

Avalue Technology
Avalue Technology APC-2138 Quick reference guide