APART REVAMP2600 User manual

REVAMP2600
Instruction manual


Instruction manualREVAMP2600
3
REVAMP2600 MANUAL

4
PROFESSIONAL POWER AMPLIFIER
Safety first!
• Caution! This professional device needs to be installed by
qualified personnel only.
• Please check the carton box for any kind of damage on
reception of the goods. In case of a damaged carton, please
contact your dealer before opening the carton.
• !!!! Danger !!!! Exposure to high sound levels may cause a
permanent hearing loss. Individuals vary considerably to sound
pressure level induced hearing loss but nearly everyone will
lose some hearing if exposed to high sound pressure levels for
a sufficient amount of time. Therefore it is recommended that
all persons exposed to equipment capable of producing high
sound pressure levels, such as this amplifier, be protected by
hearing protection while installing or operating this unit.
• Read all documentation before operating your equipment.
• Keep all documentation for future reference.
• Save the carton and packing material even if the equipment has
arrived in good condition.
• Should you ever need to ship the unit, use only the original
factory packing.
• Do not spill water or other liquids into or on the unit.
• Make sure power outlets conform to the power requirements
listed on the back of the unit.
• Do not use the unit if the electrical power cord is frayed or
broken.
• Always operate the unit with the AC ground wire connected to
the electrical system ground.

Instruction manualREVAMP2600
5
• Set level controls on amplifiers all the way down during power-
up to prevent speaker damage if there are high signal levels at
the inputs.
• Do not connect the inputs / outputs of amplifiers or consoles
to any other voltage source, such as a battery, mains source, or
power supply, regardless of whether the amplifier or console is
turned on or off.
• Power down & disconnect units from mains voltage before
making connections.
• Do not use the unit near stoves, heat registers, radiators, or
other heat producing devices.
• Do not operate equipment on a surface or in an environment
which may distort the normal flow of air around the unit. If the
unit is used in an extremely dusty or smoky environment, the
unit should be periodically “blown free” of dust.
• Do not remove the cover. Removing the cover will expose you
to potentially dangerous volt ages.
• Do not drive the inputs with a signal level higher than that
required to drive equipment to full output.
• Do not run the output of any amplifier back into another input.
• In case of mal-function this device should be serviced by
qualified service personnel only.
• This unit has NOT been designed for use in mobile applications,
such as: mobile discobars, mobile PA systems, Live bands, audio
rental systems, …
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER OR BACK
NO USER-SERVICEABLE PARTS INSIDE
SERVICING ONLY FOR QUALIFIED PERSONNEL

6
PROFESSIONAL POWER AMPLIFIER
Features
• 2 rack units high
• Class H amplifier topology
• 2 channel amplifier
• Dynamic output power: 2x840W @ 4Ω
• Sine wave power per channel: 2x600W @ 4Ω(500 msec)
• High thermal efficiency
• Highest possible damping factor
• Analog power supply with toroidal power transformer
• Active variable speed cooling fan
• Low power consumption
• Integrated Analog Devices® digital signal processor (DSP) with
easy one button operation: simply push the button to select an
operating mode, making this amplifier the ideal multi purpose
tool for your applications
• LF filter for increased stability when using 100 volt transformers
on the output, allowing you to use 100 volt speakers as top
speakers combined with a standard low impedance subwoofer
for example
• Integrated APC limiter/compressor
• Intelligent thermal power limiting circuit: limits the output
power to a safe limit whenever a thermal overload occurs
• Balanced XLR and euroblock inputs
• Unbalanced inputs on RCA with pass through

Instruction manualREVAMP2600
7
• Input level attenuators on all inputs
• 4-pole Speakon®speaker output connectors
• Euroblock speaker output connectors
• Extended speaker and amp protection circuits: DC protect, over
current protect, over temperature protect, input overload
• Individual channel mute buttons and versatile LED status
indicators
• This unit has NOT been designed for use in mobile applications,
such as: mobile discobars, mobile PA systems, Live bands, audio
rental systems, …
• Removable rack-ears
Note: the integrated APC limiter will automatically limit the
incoming audio signal to avoid overloads. This feature can not be
defeated and acts as a lifesaver for your valuable speakers.

8
PROFESSIONAL POWER AMPLIFIER
1. Channel 2 overload led: when this led lights up, you are
overloading the input. Lower the input signal immediately to
prevent the amplifier from shutting down.
2. Channel 1 overload led: when this led lights up, you are
overloading the input. Lower the input signal immediately to
prevent the amplifier from shutting down.
3. Channel 2 input gain setting. Adjust the input gain to the
output level of your source. Make sure to avoid the clip led
lighting up at the strongest input peak level.
4. Channel 1 input gain setting. Adjust the input gain to the
output level of your source. Make sure to avoid the clip led
lighting up at the strongest input peak level.
5. DSP selector switch with led indicators: push the button to
scroll between the various pre-programmed DSP settings.
There are 6 possible DSP settings and 2 available combinations.
The settings will be memorized and recalled when the unit is
Connections
1
10 8 912 14
11 13
3 4 5 6
2 7

Instruction manualREVAMP2600
9
powered up. Full details of the available settings can be found
below.
6. Channel 2 speaker output on 2 pole euroblock connector.
7. Channel 1 speaker output on 2 pole euroblock connector.
8. Channel 2 speaker output on speakon connector. Pin 1+ =
speaker 2 +, pin 1- = speaker 2 -.
9. Channel 1 and 2 stereo speaker output on speakon connector.
Pin 1+ = speaker 1 +, pin 1- = speaker 1 -; Pin 2+ = speaker 2+,
pin 2- = speaker 2-.
10. Channel 2 unbalanced input and link cinch connector: connect
the line level input signal for channel 2 here. Line level is 0 dBV.
Input and link connector are internally connected 1 on 1.
11. Channel 1 unbalanced input and link cinch connector: connect
the line level input signal for channel 1 here. Line level is 0 dBV.
Input and link connector are internally connected 1 on 1. This
connector is also used when DSP mode CH1 SUB – CH2 TOP is
selected.
12. Channel 2 balanced input on 3 pole euroblock connector.
13. Channel 1 balanced input on 3 pole euroblock connector. This
connector is used in bridge mode or when DSP mode CH1 SUB
– CH2 TOP is selected.
14. Mains inlet: connect the mains power cord here.

10
PROFESSIONAL POWER AMPLIFIER
Operation
1. Removable rack ears for 19 rack mounting.
2. Power switch: after switching on the power, the power led will
light up after approx 1 second. The limit-muted leds will light
up for a few seconds to avoid excessive power on pop noise.
3. Power led
4. Channel 1 status led bar and mute switch: when the mute
switch is pressed, the orange “LIMIT – MUTED” led will light
up. This led will also light up when the internal limiter is
activated to avoid the amplifier from being overloaded by high
input signals. The “CLIP – OVERLOAD” led indicates that the
power amplifier is clipping: reduce the input signal at once
whenever this occurs !!! The green “SIGNAL - -40dB” led
will light up when an input signal is present. The red “INPUT
– OVERLOAD” indicates that the input is being overloaded.
Reduce the incoming signal at once !!! This led will blink
when temperature protect is active: in this case the amplifier
will automatically reduce the output power to avoid further
overheating.
1 12 3 4 6
5

Instruction manualREVAMP2600
11
DSP features and audio signal routing
There are 10 possible DSP settings. The settings will be memorized
and recalled when the unit is powered up. 3 of these settings are
meant for low impedance use, the other ones are for 100 volt use
or a combination of low impedance and 100 volt.
5. Channel 2 status led bar and mute switch: when the mute
switch is pressed, the orange “LIMIT – MUTED” led will light
up. This led will also light up when the internal limiter is
activated to avoid the amplifier from being overloaded by high
input signals. The “CLIP – OVERLOAD” led indicates that the
power amplifier is clipping: reduce the input signal at once
whenever this occurs !!! The green “SIGNAL - -40dB” led
will light up when an input signal is present. The red “INPUT
– OVERLOAD” indicates that the input is being overloaded.
Reduce the incoming signal at once !!! This led will blink
when temperature protect is active: in this case the amplifier
will automatically reduce the output power to avoid further
overheating.
6. DSP setting led display: the leds show which of the DSP settings
or combinations have been activated.

12
PROFESSIONAL POWER AMPLIFIER
A. LOW impedance applications
1. NORMAL STEREO (no led): default setting for normal stereo
operation.
2. CH1 SUB + CH2 TOP (led 1): frequencies below 100 Hz are sent
to the sub channel (CH1). Frequencies above 100 Hz are sent to
the top channel (CH2). Filter slope is fixed: 12 dB/oct or second
order Butterworth characteristic. Audio signal from input 1 is
used.
3. CH 1 linked CH 2 (led 4): Both output channels will amplify the
signal from the CH1 input.
B. 100V applications
4. CH1 TRAFO + CH2 full range (led 2): channel 1 is optimized for
transformer loads, channel 2 is optimized for low impedance
applications.
5. CH1 SUB + CH2 TRAFO TOP (led 1 + led 3): frequencies below
100 Hz are sent to the sub channel (CH1). Frequencies above
100 Hz are sent to the top channel (CH2). Filter slope is fixed:
12 dB/oct or second order Butterworth characteristic. Channel
2 is optimized for transformer loads. Channel 1 input is sent to
output 1, channel 2 input to channel 2.
6. CH1 TRAFO + CH2 TRAFO (led 2 + led 3): both channels are
optimized for transformer loads.
7. CH1 TRAFO linked CH2 full range (led 2 + led 4): channel 1 is
optimized for transformer loads, channel 2 is optimized for low

Instruction manualREVAMP2600
13
impedance applications. The input signal from channel 1 is used
for both channels.
8. CH1 full range linked CH2 TRAFO (led 3 + led 4): channel 1
is optimized for low impedance full range loads, channel 2 is
optimized for low transformer loads (100 volt applications). The
input signal from channel 1 is used for both channels.
9. CH1 TRAFO linked CH2 TRAFO (led 2 + led 3 + led 4): channel 1
and 2 are optimized for transformer loads. The input signal from
channel 1 is used for both channels.
10. CH1 SUB linked CH2 TRAFO TOP (led 1 + led 3 + led 4):
frequencies below 100 Hz are sent to the sub channel (CH1).
Frequencies above 100 Hz are sent to the top channel (CH2).
Filter slope is fixed: 12 dB/oct or second order Butterworth
characteristic. The input signal from channel 1 is used for both
channels.

14
PROFESSIONAL POWER AMPLIFIER
!!! IMPORTANT !!!
This amplifier relies on convectional and active cooling. In normal
situations, overheating will not occur. The unit can be built in a 19
inch rack system, but it is forbidden to block the ventilation holes
provided. Therefore, it is absolutely necessary to allow at least
one free rack space or 44 mm above and beneath the amplifier.
Make sure the ambient temperature is between 0 and 40°C.
Operating the unit beyond its normal limits will result in excessive
internal temperature. Power amplifiers are hard workers, and
their behaviour is similar to human beings. In extreme conditions,
human beings are not able to perform efficiently. This also applies
to amplifiers. It is generally a bad idea to mount multiple heat
generating units such as amplifiers in the same rack. If necessary,
use an additional forced ventilation system in your mounting rack.
The mains fuse is located inside the unit. When the fuse is broken,
replace it with a fuse of the same current and voltage rating: 10
AT/250V. For qualified personnel only!
This unit has NOT been designed for use in mobile applications,
such as: mobile discobars and DJ setups, mobile PA systems, Live
bands, audio rental systems, …
Use it in fixed installations only.

Instruction manualREVAMP2600
15
Technical specifications
Dynamic output power 840 W @ 4 Ω
Sine wave power per channel 600 W @ 4 Ω (500 msec)
Minimum output load impedance CH1
and CH2
4 Ω
Input connections 2 x balanced euroblock, 2 x balanced
XLR, 4 x unbalanced cinch with pass
through
Input sensitivity 0 dBV / 1V
Input impedance 22 kΩ
S/N ratio > 98 dB A weighted
THD ch. 1/2 < 0.05% @ 100 W / 4 Ω /1 kHz A
weighted
Frequency response 10 – 24 kHz + 0 / -3 dB
Built-in DSP yes
Protection circuits over current, over temperature, DC
offset, AC and DC over- and undervoltage
Channel separation > 67 dB @ 1 kHz
Damping factor > 60 all channels
APC sytem internal compressor and clip limiter
Power amp topology class H
Power supply toroidal transformer
Cooling forced
Max power consumption 1840W
Operating temperature range 0 to 40°C
Mains operating voltage 230VAC/50-60Hz
Dimensions 483 x 88 x 332 mm (including rack ears)
Net weight 12.1 kg
Gross weight 14.7 kg

16
PROFESSIONAL POWER AMPLIFIER

Instruction manualREVAMP2600
17

18
PROFESSIONAL POWER AMPLIFIER


developed
by
Audioprof nv
Industriepark Brechtsebaan 8 bus 1
2900 Schoten - Belgium
Company names, product names and trademarks are property of their
respective owners.
Apart-Audio specifications are subject to change without notice.
Table of contents
Other APART Amplifier manuals

APART
APART CHAMP-3D User manual

APART
APART REVAMP1680 User manual

APART
APART PIR7600 User manual

APART
APART pubdrive2000 User manual

APART
APART REVAMP4120T User manual

APART
APART REVAMP8250 User manual

APART
APART MA-35 User manual

APART
APART Champ-4 User manual

APART
APART PM7400 MKII User manual

APART
APART Champ - 4 User manual

APART
APART PA4060 User manual

APART
APART PA8250 User manual

APART
APART ZONE4 User manual

APART
APART Concept 1T User manual

APART
APART MA247 series User manual

APART
APART MA30 User manual

APART
APART MA200R User manual

APART
APART MA-35 User manual

APART
APART MA247 series User manual

APART
APART MA240 User manual