aptos MAC DTU User manual

Version 1.0 (August 2021)

2
MACTM DTU
Contents
1. Important Safety Information..................................................................................................................................3
1.1 Read this First.........................................................................................................................................................3
1.2 Safety Instructions................................................................................................................................................ 3
1.3 User...........................................................................................................................................................................3
1.4 Support and Contact Information.................................................................................................................... 3
1.5 Other Information.................................................................................................................................................4
2. Aptos Microinverter System...............................................................................................................................4
2.1 Microinverter..........................................................................................................................................................4
2.2 DTU........................................................................................................................................................................... 4
2.3 Aptos Monitoring Server.............................................................................................................................. 4
3. Interface Layout...........................................................................................................................................................5
3.1 Interface Layout.................................................................................................................................................... 5
3.2 Export Management Function (RS485 port)...................................................................................................5
3.3 Remote Active Power Control (RS485 port).....................................................................................................6
3.4 DRM Port................................................................................................................................................................. 6
3.5 Local Install Assistant...........................................................................................................................................7
4. DTU Installation........................................................................................................................................................... 8
4.1 System Capacity.....................................................................................................................................................8
4.2 Basic Conditions Required..................................................................................................................................8
4.3 Dimensions............................................................................................................................................................. 8
4.4 System Installation Sequence............................................................................................................................9
4.5 Preparation.............................................................................................................................................................9
4.6 Install the DTU..................................................................................................................................................... 10
5. Complete Installation Map......................................................................................................................................12
6. Site Creation on HMP................................................................................................................................................13
7. Customer Login..........................................................................................................................................................14
8. Browse the Web Station...........................................................................................................................................14
9. View Phone APP......................................................................................................................................................... 15
10. LED Indicators.......................................................................................................................................................... 15
11. Technical Data..........................................................................................................................................................16
© 2021 Aptos Solar Technology, LLC. All rights reserved.

3
1. Important Safety Information
1.1 Read this First
This manual includes important instructions for installing and maintaining the Aptos Data
Transfer Unit (MACTM DTU).
1.2 Safety Instructions
Note that only professionals can install or replace DTU.
Do not try to repair DTU without approval from Aptos. If DTU is damaged, please return
to your installer for repairing/replacing. Disassembling DTU without approval from Aptos will
invalidate remaining of the warranty period.
Please read all instructions, warnings, and technical specifications carefully.
Do not use Aptos products in ways unspecified by manufacturer. Doing so may result
death/injury to persons or damage to equipment.
1.3 User
This manual is only for professional installation and maintenance personnel to use.
1.4 Support and Contact Information
Symbol
Usage
Indicates a hazardous situation that can result in deadly electric
shock hazards, other serious physical injuries, or fire hazards.
Indicates directions that must be fully understood and followed
entirely to avoid potential safety hazards including equipment
damage or personal injury.
Indicates that the described operation must not be carried out. The
reader should stop, use caution, and fully understand the operations
explained before proceeding.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

4
If you have technical queries concerning our products, please contact your installer or
distributor. If further support is required, please contact Aptos’ support at this link.
www.aptossolar.com
Aptos customer service center: [email protected]m
1.5 Other Information
Product information is subject to change without notice. The user manual will be updated
frequently; please refer to Aptos Solar Technology's official website at
www.aptossolar.com for the latest version.
2. Aptos Solar Technology Microinverter System
2.1 Microinverter
The Microinverter converts the DC output of PV modules into grid-compliant AC power. It
sends the output information of PV modules and the operation data of the microinverters to
the DTU, which is the hardware basis of the module-level monitoring. With conversion
efficiency up to 96.7%and MPPT efficiency up to 99.9%, Aptos microinverters rank in
the first class of the world’s microinverter industry.
2.2 DTU
The DTU is the key component in Aptos microinverter system. It works as the
communication gateway, which operates between the Aptos microinverters and the
Aptos Monitoring Server. The DTU communicates with the microinverter wirelessly via
2.4GHz Proprietary RF (Nordic), collecting the operation data of the system. Meanwhile, the
DTU connects to the Internet via router and communicates with Aptos Monitoring Server. The
microinverter system operation data will be uploaded to Aptos Monitoring Server via DTU.
2.3 Aptos Monitoring Server
The Aptos Monitoring Server collects the operation data and status of the microinverters in
the system and provides the module-level monitoring for the users and maintenance staff.
The following diagram shows the Aptos Microinverter system:
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

5
3. Interface Layout
3.1 Interface Layout
Item
Description
A
SD Card Slot
B
DTU Power Indicator
C
DTU Communication Indicator (With Server)
D
DTU Communication Indicator (With MI)
E
DTU Alarm Indicator
F
WiFi Antenna (2.4G)
G
RS485
H
DRM Port (For Australia only)
I
Ethernet Port
J
USB Port
K
Reset Bottom
L
Power Port
M
2.4G Antenna
3.2 Export Management Function (RS485 port)
a. Device Required.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

6
Aptos Microinverter: 2-in-1 Unit and Single Unit
DTU: MACTM DTU:
Meter: Chint Meter (DDSU666)/Chint Meter (DTSU666)/CCS WattNode
Meter
b. Export Control Type.
Type 1: Zero Export: to limit the exporting power to zero so that it can prevent the
generated power feed back to the grid.
Type 2: Export Limit: to limit the exporting power within a certain value.
Type 3: Production and Consumption Monitoring: enable to measure the PV
generating under a high accuracy.
c. Installation Diagram.
MAC 800R MAC 800R
MAC 800R MAC 800R
Note: Please refer to “Aptos Export Management Technical Note” for more details.
3.3 Remote Active Power Control (RS485 port)
Some countries require generating plants to be equipped with a logic interface (input port) in
order to cease output active power or limit active power to a regulating level. This logic
input can be RS485 port, Ethernet port, etc. MACTM DTU provide RTU Modbus protocol
over RS485 port for this remote active power control. For more information, please refer to
“Modbus implementation Technical Note”.
3.4 DRM Port
DRM port is provided to support several demand response modes as below by connecting
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

7
external control device with a standard RJ-45 connector. For MACTM DTU, it can
support DRM0/5/6/7/8 if used with Aptos microinverters.
Mode
Requirement
DRM0
Operate the disconnection device
DRM1
Do not consume power
DRM2
Do not consume at more than 50% of rated power
DRM3
Do not consume at more than 75% of rated power AND Source reactive power if
capable
DRM4
Increase power consumption
(subject to constraints from other active DRMs)
DRM5
Do not generate power
DRM6
Do not generate at more than 50% of rated power
DRM7
Do not generate at more than 75% of rated power AND Sink reactive power if capable
DRM8
Increase power generation
(subject to constraints from other active DRMs)
3.5 Local Install Assistant
Local Install Assistant is a new function integrated with MACTM DTU. Please download
the Installer App (for installer/distributor use only) first.
MACTM DTU has improved from the previous generation of DTU products. New
functions allow installer to:
a. One step to complete the WiFi configuration;
b. Station overall Inverters status indication allows the installer to see how many MI under
this DTU is working properly (and the details for each MI) and how many is abnormal (and
the details for each MI) with one glance of eyes;
c. Add the Connection status, which will display the signal strength between each MI with
connected DTU, so that installer can adjust the DTU installation location accordingly. This
function will simplify the DTU installation, and avoid a second visit by the installler due to a
poor connection between DTU and certain MI.
Note: Please refer to “Aptos Local Install Assistant Technical Note” for more details.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

8
4. DTU Installation
4.1 System Capacity
The MACTM DTU is capable of monitoring up to 99 panels. If the communication between
the DTU and microinverter caused by the installation conditions, the number of PV modules
that the DTU can monitor may be reduced.
Note: Max. monitoring quantity is for open space, installation condition meets the
requirement from both DTU and Microinverter manual, and the distance between
Microinverter and DTU needs to be within the required range.
4.2 Basic Conditions Required
Before installing the DTU, ensure that the site meets the following requirements:
Standard 220 VAC power outlet.
Stable broadband internet connection.
Router with Ethernet port.
The environmental requirements for DTU installation:
Away from dust, liquid, acidic, or corrosive gas.
The temperature should be between -20ºC and 55ºC.
If you plan to install the DTU on the wall, please prepared two #8 (4.166mm diameter) screws
and a screwdriver in advance.
4.3 Dimensions
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

9
1. Install the PV modules and
microinverters and repeater
2. Locate the DTU
9. Wall-mount the DTU (optional)
4. Start procedure
5. Normal operation
7. Add Microinverter ID
6. Login the local interface of the DTU
8. Check the Communication
between Microinverters and DTU
(Unit: mm)
4.4 System Installation Sequence
4.5 Preparation
A. Download the Aptos mobile App
3. Connect to the Internet
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

10
B. Check the box for following items:
-Aptos MACTM DTU
-Two Antennas
-Adapter
-Bracket
-5-Pin Plug
C. Choose the way MACTM DTU connects to the Internet:
Use WiFi or Ethernet. Please prepare for the following items, if
needed:
- Ethernet Cable (for Ethernet option).
-Aptos Installer App.
4.6 Install the DTU
Step 1: Install the antennas
Take two 2.4G antennas out from the box. Screw the antenna into the WiFi port and 2.4G port.
Note:If the DTU installation location is inside the metal box or under the metal / concrete roof,
extended 2.4G cable or 2.4G sucker antenna will be suggested, which can be purchased from
Aptos or local electrical store (Please contact Aptos Tech. support team for the detail type of the
Step 2: Choose an Installation Location
- Installed on the top floor to increase the signal strength.
- Installed near the center of the PV array.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

11
-Installed at least 0.5m above the ground and more than 0.8m away from the corner.
Note: To prevent signal dilution, do not install the DTU directly above metal or concrete.
Step 3: Choose the Installation Method
Option 1: Mount the DTU on the wall.
-Screw the bracket on the wall. Choose at least two screw holes (one from each side) to affix the
bracket (the M4 screws need to prepare by installer);
-Match the brackets upper buckle with MACTM DTU;
-Match the brackets lower buckle by gently press the lower side of the MACTM DTU until you
hear a click. Please make sure the antennas are vertical to the wall.
Option 2: Place the DTU on the table
-Place DTU on the table. Ensure the antennas are vertical to the table;
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

12
a. Plug in the power adapter to power the DTU;
b. Set up with Internet.
a. Use a smart phone or tablet to open the Installer App and log-in. Approach to “Me”
on the bottom
of the page and then “Network Configuration”. Complete the WiFi configuration (for WiFi
option);
b. Use the LAN cable. Connect one side with the house router and the other side with the DTU
Ethernet port
Use the smart phone/tablet to open the Installer App and login. Approach to “Me” on the
bottom of the page and then “Network Configuration”, select “Ethernet” (for Ethernet option).
5. Complete Installation Map
Please complete the installation map.
A) Peel the serial number label (as circled below) from the DTU and place it on the installation
map.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

13
B) Complete system information of the installation map shown as follows.
6. Site Creation on HMP
A. Install Aptos Installer APP by searching “Aptos” at the App Store (IOS) or Play Store
(Android).
B. Open the APP and login in with your installer account name and password. If you are a
new installer with Aptos, please apply an Installer account from your distributor in
advance.
C. Add Station, select the “Station” tab on the bottom, then select “⊕” on the right top side of
the page.
D. Select “Quick” for Single-DTU and “Profession” for Multi-DTU.
E. Please fill in the station details accordingly, and press “Next” after completed.
F. Press “Add DTU ID”, scan the DTU ID (or you can manually input ID) and press “Next” after
complete.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

14
G. Click “Start binding” and choose the angle and tilt base on the installation.
H. Scan the Microinverter ID (or manually input the ID) and click the check box after
completing each ID input. Press “Finish” once all Microinverter ID has been input.
I. Disable the Scan function on the top of the right-hand side and design the Layout base
on the installation. Click the tick box on the top of the right-hand side. Then select “Next”
after completing the design.
J. Upload a picture of the site and select “Finish” to complete the site creation.
K. The new site will appear on the Station list from the Installer account.
L. Please click the “Networking” button after the power station is created.
M.Please wait about 30 minutes, the station will show online, and all the MI-IDs are found.
7. Customer Login
a. Please download the End User App. You can search “Aptos” at the App Store (IOS) or
Play Store (Android).
b. Log in with the Password and Username that has been set up by Installer on the
previous step (Section 6, step e), and press “Login”.
c. Customers can view all details once data uploads. Estimated time: 30 minutes.
d. Customer can also view the Microinverter generating details by accessing the Aptos
monitoring platform website at https://world.hoymiles.com.
8. Browse the Web Station
Log in your account and browse the web station.
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

15
9. View Phone APP
Download mobile phone application to view station information
10. LED Indicators
The system status can be viewed by Aptos local APP or LED indicators.
LED
mark
LED Color
Explanation
DTU power on or power off
Network communication
Microinverter communication
Fault State
LED States
LED
Indicator
Status
Description
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

16
11. Technical Data
Model
MACTM DTU
Type
2.4GHz Proprietary RF (Nordic)
Maximum distance (open space)
200m
Monitoring data limit from solar
panels
992
Communication to Cloud
Type
WIFI(802.11b/g/n)1/Ethernet
Sample rate
Per 15 minutes
Communication to Meter
Signal
RS485
Maximum distance (RS485 cable)
500m
Display
LED
LED Indicator * 4 – RUN, Cloud, MI, ALM
APP
Local APP
Power Supply
Type
External plug-in adapter
All
Firmware upgrading
Starting up
DTU power on
DTU power off
DTU are communicating with Aptos Monitoring
Server
Internet disconnected
Internet connected, Server disconnected
Local APP connected
Microinverters are communicating
MI IDs Incomplete
No MI ID (Please perform Networking)
Normal
DTU alarm occurred
Microinverter alarm occurred
Meter alarm occurred
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MACTM DTU

17
Adapter input voltage/frequency
100 to 240 V AC / 50 or 60Hz
Adapter output voltage/current
5V / 2A
Power consumption
2.5W (typical), 5W (maximum)
Mechanical Data
Ambient temperature (℃)
-20°C to 55°C
Dimensions (W×H×D)
200mm×101mm×29mm
Weight
0.20 kg
Mounting system
Wall mounting / Desktop mounting
Features
Compliance
FCC 15B, FCC 15C, EN60950-1, EN61000-3-2,
EN61000-3-3, EN301489, EN300328, EN300440, RCM
*1 If the DTU installation location is inside the metal box or under the metal/concrete roof, extended antenna will
be suggested.
*2 Depending on the installation environment, please refer to user manual for more details.
© 2021 Aptos Solar Technology, LLC. All rights reserved.