AQUA-RELIEF ARS-2000D User manual

~
K
L
LI
C
I
Hot
and
coldportabletherapy
system
Model
ARS-2000D
Note:pleaseread
all
instructions
and
warningsbeforeoperatingthisunit
OPERATING
INSTRUCTIONS
The
AKS
2000
can
seriously
injure
skin
if
used
improperly.
Follow
all
instructions
to
ensureproduct
safety.
Discuss
TREATMENT
WITH
YOUR
LICENSED
HEALTH
CARE
PRACTITIONER
Provide
a
complete
medical
history
including
any
reactions
to
cold.
Ask
your
practitioner
about
potential
adverse
reactions
and
cold-induced
injuries.
Certain
conditions
make
cold-induced
injuries
more
likely.
Use
only
according
to
your
prescription.
Adhere
strictly
to
doctor'sinstructionsregardinguse,treatmenttimes,treatment
frequency,
settings,
self-assessment
and
generalbest
practices
regardingyourspecificcondition.
1.
Connecttherapy
pad(or
booties
if
provided)
tothe
coolerhose.Couplings
will
click
when
theylock
together.
2.
Make
sure
the
powersupply
is
unplugged
while
adding
water;
3.
For
coldtherapy,open
the
cooler
and
fill
with
iceto
above
the
fill
line
and
then
fill
with
water
tothe
fill
line;
for
heattherapy,
add
warm
tap
water
to
fill
line.
NEVER
OPERATE
UNIT
WITHOUT
WATER.
User
must
fill
water
tothe
fill
line
before
turning
onthe
pump.
4.
Plugpowersupply
into
the
wall
outlet.
(Seepowersupplylabel
for
voltage.)
NOTE:
Always unplug unit
when
refilling
with
ke
and
water.
5.
Position
padonthe
target
therapyarea
with
the
smoothsidetoward
the
skin
or
slip
onthe
booties.
6.
If
booties
are
included
with
yoursystem,always
use
with
the
diabeticsocks
provided;
the
socksprovidebuffering
and
comfort
tothe
area.
Place
feet
into
the
booties
and
secure
Velcrostrap.Always
usean
insulation
barrier(such
as
Webril,Kerlix,cast
padding,
or
elasticbandage)
between
the
ARS
therapy
padand
skin.
NOTE:
Donotletthe
AKS
therapy
pad
treat
exposed
skin.
If a
sterile
dressing
is
required
by
your
doctor,
but
does
not
wholly
cover
the
skin under
the
therapy pad,
usean
additional insulation
barrier.
7.
Ifyouare
using
the
universal
or
backpad,
usethe
enclosedelastic
belt
to
comfortably
hold
the
wrap
in
place.
Donot
over-tighten
the
elastic
belt.
8.
Set-yourtemperaturemode
tothe
desired
temperature;
cold,
low
heat
or
high
heat.
Be
sure
to
consultyourphysician
ifyouare
treating
a
condition.
9.
The
Control
Panel
settings
onthe
unit
are
Cold,
when
using
with
iceand
water,
andHot
when
using
tap
water.Whenusingcoldtherapy,periodicallyreplenish
iceas
needed.
10.
The
treatment
timer
isan
analogue
timer,
onceadjusted,
the
timer
will
setto
that
time
till
expired.DANGER:
TheC
setting
isa
continuous operation
ofthe
unit
(with
no
auto-shutoff)
anditcanbe
dangerous.
Please
Consultyourphysician
for
recommended
treatment
time
settings.
11.
User
MUSTemptywater from
the
unit
afterevery
treatment
session.
CAUTIONS
AND
WARNINGS
Danger
- to
reduce
the
risk
of
burns,
adverse
reactions,
and
malfunction,
this
product
must
be
used
in
accordance
with
the
following
instructions.
cold
therapy
could
result
in
serious
injury
like
full
thickness
skin
necrosis.
Supervision
may
be
necessary
to
ensureprecautions
are
followed,
especially
with
youngchildren
andthe
elderly.
1.
Ensurepads
arenot
wrapped
too
tight.
2.
If
numbness
or
burning
occurs,
discontinue
useand
consult
yourprescribingphysician.
3.
Heat
can
burn
or
irritate
skin.
For
this
reason,
itis
best
nottouseit
directlyagainst
the
skin.
Note:
Minor
skin
redness
istobe
expected.
4.Ifthe
ARS
pump
is
beingused
onan
injury;
refrain
from
usingheat
forat
least
48
hours.
5.
While
in
use,
keep
ona low
surface,
but
awayfrom
disturbance
by
pets
or
children.
CONTRAINDICATIONS
»
History
of
coldinjury,frostbite,
or
adverse
reactions
to
cold
application
»
History
of
heatinjury
or
adverse
reactions
to
heat
»
Monitor
patients
skin
condition
during
therapy(every
20
minutes);
special
care
monitoringmust
be
provided
for
children,
patients
on
prolonged
therapy,
unconscious
or
incapacitatedpatients,diabetics,
and
those
with
poorcirculation
»
Application
areas
with
compromisedlocalcirculation
»
Potentialwoundhealingproblems,includingthose
from
multiple
surgical
procedures;
donot
apply
heat
to
areas
that
are
susceptible
to
developing
bedsores
»
Circulatory
syndromes
such
as
Raynaud's
disease,
Buerger's
disease,
peripheral
vascular
disease,
vasospastic
disorders,
sickle
cell
anemia,
and
hypercoagulable
clotting
disorders
»
Local
tissue
infection
»
Hand/wrist
or
feet/ankle
surgery
w/
polyneuropathy
RISK
FACTORS
FOR
COLD-INDUCED
INJURY
»
Pathologicalsensitivity
to
cold
»
Youngchildren
andthe
elderly
»
Behaviors
that
negatively
effect
circulation,
such
as
poor
nutritional
habits,usingtobacco,caffeineabuse,
and
alcohol
abuse
»
Medications
that
negativelyimpactmentalcapacity
»
Diabetes
»
Application
areadesensitization
dueto
local
anesthesia
or
regionalnerveblocks
»
Medications
that
have
a
negativeeffect
on
peripheral
vascular
circulation:betaadrenergicblockers
and
localized
epinephrine
»
Excessive
moisture
atthe
applicationsite
»
Hand/wrist
or
feet/ankle
surgery
»
Communication
barriers
If
theriskof
cold-inducedinjury
is
greaterthan
the
benefit
of
coldtherapy,
donot
prescribe
the
ARS
2000,
When
prescribing
to
patientswith
risk
factors:
»
Use
highertemperatures
ora
thickerinsulationbarrier
on
the
skin
.»
Shorter
treatmenttimes,
less
frequentapplication,
or
eliminatingnighttimeapplication
»
Frequent
skin
checks
and
follow
up
examinations
ELECTRICAL
PRECAUTIONS
Keep
connectionsdry.
Thq
ARS
2000holds
and
pumps
water,
the
electricalconnections
atthe
power
outlet
and
from
the
powercord
tothe
ARS
2000
unit
arenot
waterproof
and
must
be
keptdry.
Always
keep
the
unit
in
a
placewhere
the
connections
will
not
fall
into
water
(e.g.,
a
tub,sink,
etc.).
Ifthe
electricalconnections
fall
into
water,
donot
touch
anywet
part
ofthe
product.
Unplug
only
atdry
electrical
connections.
Do
not
operate
— or
unplug
immediately
— if
transformer,
plug,
or
cord
is
damaged.
To
resolve
damaged
parts,
unplug
and
contactPMT.
..
CONNECT
TOA
PROPERLY
GROUNDED
OUTLET
ONLY.
»
DONOT
HANDLE
THE
TRANSFORMER
OR
ELECTRICAL
CORD
WITH
WET
HANDS.
..
UNPLUG
TO
STOP
THE
PRODUCT
WHEN
NOTIN
USE.
Unplugimmediatelyafteruse.
Never
leave
unattended
when
plugged
in.
»
USE
INDOORS
ONLY
.
FLAMMABILITY
Do
notusein
places
with
flammable
vapors
or
gasses,
high
oxygen
concentrations
or
other
oxidizers.
Risk
of
explosion
if
used
inthe
presence
of
flammable
anesthetic.
Keep
the
cord
and
transformerawayfrom
heated
surfaces
WATER
DAMAGE
AND
LEAKS
»
WATER
SPILLAGE
CAN
HAPPEN
DURING
USE.
THEREFORE,
PLEASE
SET
THE
ARS-2000
ONA
SURFACETHAT
CAN
TOLERATE
SPILLS
OR
WATER
ABSORPTION.
DoNOTUSEON
WOOD
THAT
CAN
WARP,
FINE
CARPET,
MATERIAL
THAT
WILL
BLEED
COLOR,
ETC.
HOWEVER,
IF
VOUR
PRODUCT
LEAKS
ORHASANY
OTHER
MECHANICAL
DEFECT,
DISCONTINUE
USEAND
CONTACT
YOUR
PROVIDER
IMMEDIATELY.
CARE
AND
MAINTENANCE
|
WARRANTY
The
ARS
Therapy
pump
canrun on tap
water.Distilled water
will
help keep
the
unit running
cleaner
than
tap
water-
but it is not
necessary
to its
operation.
To
clean
your
device,
fill
unit
to
fill line
and
then
add a
quarter
cup of
bleach
or
rubbing alcohol
circulate
through your
unit
for 10
minutes then drain
and
rerun
with
tap
water-
and
then drain again.
This
should
be
preformed
once
every
6-12
months.
When
using
the
large therapy boot (after turning
the
unit on),
add
water
to the
fill line,
asthe
large boot
consumes
more
water.
It is
optimal
to
empty
the
water
out of the
hose
and
therapypad.
However,
all
water
does
not
need
to be
removed from
the
therapy
pad (it is
going
to
be
difficult
to do
so).
If you do not
empty
the
water
out of
your
hose,
upon your next
use
you
will
hove
cold water mixing with your warm
tap
water.Either
let it
cycle
with
the
heater
on
-
or
replenish
the
reservoir
with
hotter
tap
water.
WARRANTY:
A one
year
manufacturer's
warranty
is
given
to all
Water therapy
systems.
This
warranty
is for
replacement
of
like items only.
The
warranty
does
not
cover
items
out of
production.
If the
Item
isno
longer
in
stock,
then
we
will
upgrade
to a
like model.
The
warranty policy only applies
to the
device
and
does
not
include
the pad
or
accessories
supplied
with
the
unit.
The
pad
is
coveredunder
a
30-day
warranty.
Units
used
as
commercial
rentals
can
void
the
warranty.
Prescription
labeling:
Federal
law
restricts
this device
to
sale
orusebyoronthe
order
ofa
practitioner
so
licensed
bythe
state.

ARS-2000
IMPORTANT
SAFETY
INSTRUCTIONS
READ
AND
FOLLOW
ALL
INSTRUCTIONS
DONOT
DESTROY
MUSTREADBeforeUsing
ARS
System
? DONOT
SIT.STAND
ORLAYON
PADS
Pleaseconsultphysicianbeforeusingthisdevice
A
WARNING
The
ARS-2000
canbe
cold
enough
to
seriously
injure
the
skin.
Follow
these
Operating
Instructions,
the
must-read
safety
instructions
and
all
accompanying
documentation.
WATER
DAMAGE
and
LEAKS
?
WATER
SPILLAGE
CAN
HAPPENDURINGUSE.
THEREFORE,
PLEASE
SETTHE
ARS-2000
ONA
SURFACE
THAT
CAN
TOLERATE
SPILLS
OR
WATER
ABSORPTION.
DONOTUSEON
WOODTHAT
CAN
WARP,
FINE
CARPET,MATERIALTHATWILL
BLEEDCOLOR,ETC.HOWEVER,
IF
YOURPRODUCTLEAKS
ORHASANY
OTHERMECHANICAL
DEFECT,DISCONTINUE
USEAND
CONTACT
YOUR
PROVIDERIMMEDIATELY.
TO
REDUCE
THE
RISK
OF
BURNS,
ELECTRICAL
SHOCK
AND
FIRE,
THIS
PRODUCT
MUST
BE
USED
IN
ACCORDANCE
WITH
THE
FOLLOWING
INSTRUCTIONS.
Cautions
and
warnings:
to
reduce
the
risk
of
burns,adversereactions,
and
malfunction,thisproductmust
be
used
in
accordancewithinstructions.
Contraindications
SAFETY
FORTHEARSFORUSE
DURINGPREGNANCY
HASNOT
BEENESTABLISHED.
CAUTIONSHOULD
BE
USED
FOR
PATIENTSWITHSUSPECTED
OR
DIAGNOSEDHEARTPROBLEMS.
CAUTIONSHOULD
BE
USED
FOR
PATIENTSWITHSUSPECTED
OR
DIAGNOSEDEPILEPSY.
Precautions
SENSITIVESKINPATIENTS
OR
PATIENTSWITHCOMPROMISEDCIRCULATORYDISORDERSMUSTCONSULTTHEIRPHYSICIAN
INALL
SITUATIONS.
THERE
is
ABSOLUTEDANGER
IN
USING
ARSIN
CONJUNCTIONWITHEXTERNALANALGESICS.
PLACING
METHYLSALICYLATE,CAMPHOR,
OR
MENTHOL-CONTAININGEXTERNAL
ANALGESICS
ONTHE
PAINFULAREAINCREASESSUPERFICIALBLOODFLOW.
IFA
HEATINGPRODUCT
IS
SUBSEQUENTLYPLACED
ONTHE
MEDICATEDAREA,
THE
HEATDELIVERED
TO
THE
SITECANNOT
BE
REDISTRIBUTED
VIA
BLOOD
FLOW.
THIS
INCREASES
THE
RISK
OF
BURNS.
Warnings
IFYOUARE
PREGNANT,PLEASECONSULTYOURPHYSICIANBEFOREUSING
BURNS
CAN
OCCURREGARDLESS
OF
CONTROLSETTING.
CHECK
SKIN
PLEASECONSULTYOURPHYSICIANBEFOREUSINGUNDER
PAD
FREQUENTLY
IFYOU
HAVESENSITIVESKIN,
OR
SKININSENSITIVITY,PLEASECONSULTNEVERUNPLUG
BY
PULLING
ONTHE
CONNECTINGCORDS
YOUR
PHYSICIAN
TURN
OFF
WHEN
NOTINUSE
ARS
SHOULD
BE
KEPT
OUTOFTHE
REACH
OF
INFANTS
AND
CHILDREN
AFTER
APPLYING
PADRUN
UNIT
FOR15
MINUTES
AND
CHECK
FORANY
DONOTUSE
WHILESLEEPINGDISCOMFORT.
IFYOU
FEELTHAT
THE
TEMPERATURE
ISTOOHOT?
PLEASE
THIS
PRODUCT
ISNOTTOBE
USED
BYAN
INVALID,UNCONSCIOUS PERSONDISCONTINUE
USEAND
CONTACTYOURSUPPLIER
OR
PERSONWITH
LOW
BLOODCIRCULATIONUNLESSATTENDED
DoNOT
TOUCH
ANYOFTHE
COMPONENTSINSIDEYOURRESERVOIRWHILE
DONOT
LEAVEUNATTENDEDWHILETURNED
ONTHE
SYSTEM
IS
PLUGGED
IN
DISCONTINUE
USEIFYOU
EXPERIENCE
IF
RASH
OR
DISCOMFORTPERSISTS
PATIENT
SHOULD
USE
EXTREME
CAUTION
WHEN
USING
UNIT
FOR
LONG
CHECK
SKINUNDERNEATHTHERAPYWRAPPERIODICALLYTHROUGHOUT
A
PERIODS
OF
TIME
AND
SHOULDMONITORSKINUNDERNEATH
PAD
EVERY
20
TREATMENT
SESSIONMINUTES.
ITIS
RECOMMENDED
TO
TAKERESTTIMEFROMTREATMENTS
?
ARS
SHOULD
NOTBE
APPLIEDOVERCANCEROUSLESIONS,WOUNDS,ESPECIALLYTREATMENTSEXCEEDING
60
MINUTES
INFECTEDAREAS
OR
OPENSORES
PHYSICIAN
INSTRUCTIONS
for
PRESCRIPTION
of
thisITEM:
PLEASE
READ
THE
FOLLOWING
AND
PROVIDETHISFORM
TO
YOURLICENSEDHEALTHCAREPROFESSIONAL
Provide
Prescription
and
Instructions
The
ARS-2000
is
classified
bytheFDAasa
Class
II
medicaldevicethatmust
be
prescribed
bya
physician
or
licensedhealthcarepractitioner.
A
properprescription
foruse
must
include:
Operating temperaturerangeFrequency
and
instruction
on
skininspections
Frequency
and
duration
ofuse
(andbreaks
if
applicable)TreatmentPeriod
Treatment
protocolsvarybaseduponspecificpatientconditions
and
healthhistory,physician experiencewith
continuous-flow
coldtherapyapplication,
and
medicaljudgment.
Tellpatients
howto
inspectskin
ofthe
treatment sitewithoutcompromising
the
sterility,
andhow
often
todoso.
Instructpatients
to
stopusing
the
ARS-2000
and
contact
you
immediately
if
theyexperience
any
adversereactionssuch
as:
increased
pain,
burning,
increasedswelling,itching,blisters,increasedredness,discoloration, welts,
or
otherchanges
in
skinappearance
Review
all
product informationwithyourpatient.Review
the
Information
for
Patients
and
MedicalProfessionals
in
thisdocument,
the
OperatingInstructions
onthe
unit,
andall
ancillary
instructions.
PATIENT
DISCHARGE
PROTOCOL
:
Follow
this
protocol
prior
to
discharging
the
patient
from
facility
care
to
home
use
1.
Screening
.
Screen
the
patient
forany
contraindicationsand/orassociated
risk
factors.
Ifthe
patient
hasany
contraindications,
donot
prescribe
the
ARS-2000
tothe
patient.
Ifthe
patient
hasany
associatedriskfactors,consultwith
the
licensedhealthcarepractitioner
to
determine
the
appropriatenessofapplication
ofthe
ARS-2000.
2.
Prescription
.
Instruct
the
patientregarding
the
licensedhealthcarepractitioner'sprescribedprotocol(temperature,frequency
and
duration
of
use,and,
if
applicable,
breaks),
frequency
and
instruction
on
skin
inspections,
and
treatment
period.
3.
Potential
For
Injury
.
Inform
the
patientthatimproper
usecan
result
in
seriousskininjury,includingnecrosis.Emphasize
the
importance
of
following
the
prescribed
protocol,proper
pad
application,
and
skininspection.
4.
Instructions
.
Instruct
the
patient
onhowto
properly
usethe
ARS-2000.Review
the
OperatingInstructions witheach
patient.
5.
Proper
Therapy
Pad
Application
.
Instruct
the
patientthat
an
insulationbarriermust
be
between
the
Therapy
Padand
skinduringuse.
No
part
ofthe
Therapy
Pad
should
touch
the
skin
forany
period
of
time.
6.
Skin
Inspection
.
Instruct
the
patient
to
inspect
the
skinreceivingcoldtreatment
perthe
practitioner'sinstructions,typicallyevery
20
minutes.
If
dressing,wrapping,
bracing,
or
casting over
the
Therapyprevents
the
ability
ofthe
patient
to
regularlyperformskinchecksunder
the
pad,
donot
dispense
the
ARS2000
tothe
patient.
7.
Discontinue
.
Instruct
the
patient
to
stopusing
the
ARS-2000
and
contact theirlicensedhealthcarepractitionerimmediately
if
theyexperience
any
adversereactions
such
as:
increasedpain,burning,increasedswelling,itching,blisters,increasedredness,discoloration,welts,
or
otherchanges
in
skinappearance.
Apply
InsulationBarrier
&
Therapy
Pad
Always
usean
insulationbarrier(such
as
Webril,Kerlix,castpadding,
or
elastic bandage)between
theARS
therapy
padand
skin.
DonotletanyARS
theepy
pad
treat
exposed
skin.
Ifa
sterile dressing
is
required
by
yourdoctor,
but
does
not
whollycover
the
skinunder
the
therapypad,
usean
additionalinsulationbarrier.
Skin
Inspection
Inspect
the
skin
ofthe
treatmentareas
as
prescribed(every
20
minutes).
Donotusethe
ARS-2000
if
dressing,wrapping,bracing,
or
castingoverpreventsskinchecks.Stop
using
and
contactyourpractitionerimmediately
ifyou
experience
any
adversereactions, such
as:
increasedpain,burning,increasedswelling,
itching,
blisters,increasedredness,discoloration,welts,otherchanges
in
skinappearance,
orany
otherreaction
identified
by
yourpractitioner
Table of contents
Popular Medical Equipment manuals by other brands

Ossur
Ossur Form Fit Ankle Brace Instructions for use

Orliman
Orliman 2040-S INSTRUCTIONS FOR USE AND PRESERVATION

Mettler Electronics
Mettler Electronics Sys Stim 206A Maintenance manual

Seca
Seca CT3000/P80 How-to guide

Byond
Byond ResPlus B-30P Bi-Level PAP user manual

Michigan Instruments
Michigan Instruments Thumper 1007CCMII Operation manual

Porter
Porter 6255-1 Installation and operating instruction manual

Boston Scientific
Boston Scientific DYNAGEN CRT-D Technical manual

Shukla Medical
Shukla Medical Xtract-All Nail Winquist III MSK1017 Surgical Technique Guide

Breg
Breg OA IMPULSE Instructions for use

DHP
DHP MAINSTAYS 6028149W quick start guide

Cirs
Cirs 604-GS user guide