ArcTiv Technologies Server Racks User manual

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
1
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
USER MANUAL
SERVER RACKS
NETWORK RACKS
Server & Network Racks
™

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
2
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
TABLE OF CONTENTS
PRODUCT OVERVIEW ……………………………………………………………………………………………………………………………………….
3
SAFETY INSTRUCTIONS …………………………………………………………………………………………………………………………………….
4
COMPONENT IDENTIFICATION ………………………………………………………………………………………………………………………..
5
PACKAGING …………………………………………………………………………………………………………………..………………………………..
6
ASSEMBLY ……………………………………………………………………………………………………………………………………………………….
7
CONFIGURATION ……………………………………………………………………………………………………………………………..……………..
11
WARRANTY ..………………………………………………………………………………………………………………………….………………………..
12

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
3
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
PRODUCT OVERVIEW
ArcTiv Server and Network Racks offer greater capacity, load rating and cable & airflow accessories to manage your
critical IT systems. The Server Racks are compatible with ArcTiv Aisle Containment and PDU’s for fast installation
and reliable operation. The key features of the product line include:
Curved Door with
130oRadius
Heavy Duty Castors &
Leveling Feet
Multi-Bay
Compartments
Server Racks
Split Locking
Side Panels
High Airflow, Vented
Locking Doors
Adjustable
Mounting Rails
Top Cable Entry
Access Holes
Tool-less iPDU
Mounting
Network Racks
Vertical Cable
Management
Network & Power
Cable Separation
750 & 800mmW
Options

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
4
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
SAFETY INSTRUCTIONS
•Keep the Server Racks in a controlled indoor environment, away from moisture, temperature extremes,
flammable liquids and gasses, conductive contaminants, dust and direct sunlight.
•Leave adequate space at the front and rear of the racks for proper ventilation. Do not block, cover or insert
objects into the external ventilation openings of the enclosure.
•The Server and Network Racks are heavy, use caution when handling. Do not attempt to unpack, move or
install it unassisted. Use a mechanical device such as a forklift or pallet jack to move the system in the shipping
container.
•Do not place any object on the enclosures, especially containers of liquid, and do not attempt to stack the
enclosures.
•Inspect the shipping container and the enclosure for shipping damage. Do not use the system if it is damaged.
•Leave the Server and Network Racks in the shipping container until it has been moved as close to the final
installation location as possible.
•Install the enclosures and containment system in a structurally sound area capable of handling the load, or on
a level floor that is able to bear the weight of the enclosure, all equipment that will be installed in the
enclosure and any other enclosures and/or equipment that will be installed nearby.
•Use caution when cutting packing materials. The enclosure could be scratched, causing damage not covered
by the warranty.
•Save all packing materials for later use. Repacking and shipping the enclosures and containment system
without the original packing materials may cause product damage that will void the warranty.
•Do not reship the enclosures and containment with additional equipment. The combined weight of the
enclosure and installed equipment must not exceed the load capacity of the pallet. ArcTiv Technologies is not
responsible for any damage that occurs during reshipment.
•The enclosure casters are designed for minor position adjustments within the final installation area only. The
casters are not designed for moving the enclosure over longer distances.
•When rolling the enclosure on its casters, always push it from behind; never pull it toward you.
•A rolling enclosure can cause personal injury and property damage if not properly supervised. If rolling the
enclosure down a ramp is required, use extreme caution. Do not attempt to use ramps that have a slope
steeper than 1:12.
•Use of this equipment in life support applications where failure of this equipment can reasonably be expected
to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not
recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen
or nitrous oxide.

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
5
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
COMPONENT IDENTIFICATION
Item
Component
Quantity
1
Front vented door with lock
1
2
Rear door
2
3
Top cover
1
4
Side panel
4
5
Vertical rail
4
6
Horizontal beam
6
7
Cable management rail
2
8
Door frame
2
9
Leveling feet
4
10
2” heavy duty castor
4
Important: Bottom Plate Installation Instruction (Optional)
It is better to install the optional bottom plate during steps 4 and step 5. Secure the bottom plate to the corner
bracket with M4*8mm self-tapping screws (4pcs), the bottom plate is tightened to the enclosure with M8*25mm
hexagon headed bolt.
Note: Refer to the mounting instructions
before installing the bottom plate.

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
6
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
PACKAGING
The flat-pack concept allows shipped enclosures to reduce
space, which can save container and transportation costs.
CARTON A -19" FRONT & REAR DOOR KITS
Carton A
Parts List
Quantity
(1)
Front door assy
1
(2)
Top cover
1
(3)
Rear doory assy
1
(4)
Bottom plate
1
CARTON B-19" RAILS & BEAM KITS
Carton B
Parts List
Quantity
(5)
Horizontal beam
1
(6)
Vertical rail, left
1
(7)
Cable mgmt. rail
1
(8)
Vertical rail, right
1
CARTON C-19" SIDE PANELS KITS
Carton C
Parts List
Quantity
(9)
Side panel assy
1

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
7
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
ASSEMBLY
Step 1: Connect corner brackets to the lower beams with 2 screws.
Step 2: Connect each of 6 beams to the rear door with 2 screws.

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
8
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
Step 3: Fasten each of 6 beams in Step 2 to the front door with 2 screws
Step 4: Fasten corner brackets in Step1 to the front with 2 screws

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
9
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
Step 5: Install the cage nuts to the required square openings in the mounting beams, one for each beam where you
plan to install the cable management rails. Use M6 washers and mounting screws to secure the cable management
rails, one for each side. Place M6 washers between the screws and the equipment mounting rails.
Step 6. Install the cage nuts to the desired square openings as step 5. Fasten the rails to the mounting beams with
3 screws and M6 washers, two rails for each side.

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
10
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
Step 7. While holding the top cover, arrange the 2 pins near the rear of the top cover into the holes in the enclosure
frame. Pull the roof panel downward until it’s close to the enclosure frame.
Step 8. Open side panel latch by sliding it downward, then install side panels into the frame.

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
11
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
CONFIGURATION
Step 1. Placement
Use the casters to move the enclosure over a level, smooth and stable surface by pushing the unit.
Step 2. Leveling
After locating the enclosure in right place, use the leveling feet on 4 corners to level the unit on the floor. Make
sure the enclosure is leveled before attempting to install equipment.
Step 3. Grounding Connection
Make sure all the parts of the enclosure are properly bonded and grounded to the frame, then connect to one of
the designated grounding locations (two M6 threaded inserts on front/rear door frame) directly to your facility's
earth ground connection with 8AWG wire. Do not use the enclosure without a proper earth ground connection.
Step 4. Alignment
Align the enclosures and join them using one M5 flat-head screw (pre-installed on the door frame) per bracket-two
brackets for the front and two brackets for the rear.
Step 5. Equipment installation
Do not install any equipment until the unit is stabilized. Install the heavier equipment first and towards the bottom.
Note: The square holes at the middle of each U-shaped vertical rail are numbered and also include a small notch to
aid identification. When installing equipment, use cage nut to secure your equipment to the U-shaped vertical rail.

USER MANUAL: ARCTIV SERVER & NETWORK RACKS
12
© 2021 ArcTiv Technologies, LLC ATSVR-NWR-MANUAL-01
WARRANTY
2-Year Limited Warranty. Seller warrants this product, if used in accordance with all applicable instructions, to be
free from original defects in material and workmanship for a period of 2 years from the date of initial purchase. If
the product should prove defective in material or workmanship within that period, Seller will repair or replace the
product, at its sole discretion.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE,
ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH
HEREIN.
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate
or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no
representation or warranty as to the suitability or fitness of these devices for any specific application.
If you have questions about this product or need technical support, please contact us or visit our website.
ArcTiv Technologies, LLC
30 N Gould St Ste 22117, Sheridan, WY 82801
www.arctiv-tech.com
Latest Revision: June, 2021
™
This manual suits for next models
1
Table of contents
Popular Rack & Stand manuals by other brands

PDR
PDR AWM125-120 instructions

SilverStone
SilverStone RMS01 installation guide

Digital Equipment
Digital Equipment VAX 4000 Series Installation information

X-Stand
X-Stand PATRON XSFP456 Assembly and Safe Use Manual

KONDATOR
KONDATOR LA-911 user manual

Smart Inventions
Smart Inventions FSSBID 100 Installation and integrator's guide