1.5 Safety system
The K6 stove is equipped with five independent safety systems.
1. The feeder releases pellets into a chute, which means that the fuel cannot burn back and
spread the fire into the hopper.
2. The pellet hopper is equipped with a tight fitting filler hatch. The hatch must be closed and
locked during use, as soon as the hatch is opened the fuel feed is interrupted and a warning
text is shown on the display.
3. Two thermostats are located as shown in section 1.2 Components (fig 1). If the maximum
permitted temperature is exceeded the feeder stops, the stove switches itself off and the
display shows “Operational stoppage”. The alarm must be confirmed by pressing a button.
Do not forget to rectify the cause of the operational stoppage.
4. A flame sensor is located in the burner (fig 1).If the flame goes out or pellets
are fed in faster than they can be burnt and no flame is indicated for approx 3.5 minutes,
the stove switches itself off, and an exclamation mark illuminates while “operational stop-
page” scrolls through the display.
5. The door is equipped with a safety switch. The door must be closed during operation,
if it is opened the fuel feed is interrupted.
The safety switches are tested by unlocking the filler hatch during use or start-up.
The pellet feeder should then stop.
1.6 Control system settings
The settings are made in the control panel in a menu system. Before entering the menu
the panel is in display mode. Enter the menu by pressing the dial.
If the menu is inactive for a long time the panel returns to display mode. The menu system
consists of a main menu and several sub-menus “Usermenu” and “Settings”.
Turn the dial to scroll through the menu. To jump out of the menu, hold the button in
for 4 seconds. The menu appears as follows:
Main menu
Start? (Stop?) - Confirm by pressing once to start (stop).
Stop T - Press to select and adjust desired stop temperature.
Usermenu - Press for Usermenu.
Back - Press for display.
Usermenu
Settings
SetCode (021)
Settings - Press for Settings.
Service - Menu for authorised service technicians.
View - Press for Display menu
(See levels, operating time, programme version etc.)
OnTimer - Limited operating time.
TimeStrt - Start at desired time.
TimeStop - Stop at desired time.
NghtDrop - Possibility of lowering temperature below
specific time period during the day (1).
DayDrop - Possibility of lowering temperature below
specific time period during the day (2).
Assist.H - Set the lower temperature that is required
when maintenance heating is activated.
Clockset - Set date and time.
Back - Press for main menu.
Service - Menu for authorised service technicians.
Ign.dose - Adjust and test the pellet amount at ignition.
FeedHI - Adjust the pellet amount at high output.
TstHdose - Test the pellet amount at high output.
LoPowOn - Activate low output.
FeedLO - Adjust the pellet amount at low output.
TstLdose - Test the pellet amount at low output.
TempDiff - Adjust the number of degrees between start and stop.
AudioOff - Sound off or on.
Language - Select language.
ResOnLog - Operational time measurement is reset here.
Res#Ign - The counter for number of firings is reset here.
Default? - All the values are reset to factory settings here.
Back - Press for Usermenu.
Flame
Indicated
Firing element
Activated
Feeder motor
Activated
Combustion fan
Activated
Fault function
Indicated
Stove
in operation