ARJO HUNTLEIGH Easytrack 700.10860 Installation guide

EASYTRACK®WALL MOUNT ADAPTOR
MODEL #700.10860
INSTALLATION AND PRODUCT CARE INSTRUCTIONS
001.10650.EN rev. 6 • Jul
y
2012

Design Policy and Copyright
® and ™ are trademarks belonging to the ArjoHuntleigh group of companies.
© ArjoHuntleigh 2012.
As our policy is one of continuous improvement, we reserve the right to modify designs without
prior notice.
The content of this publication may not be copied either whole or in part without the consent of
ArjoHuntleigh.

3
001.10650.EN rev. 6
TABLE OF CONTENTS
GENERAL INFORMATION.......................................................................................................................................... 3
MANUFACTURER INFORMATION ............................................................................................................................. 4
SAFETY INSTRUCTIONS............................................................................................................................................ 4
REQUIREMENTS.................................................................................................................................................. 4
IMPORTANT SAFETY DIRECTIONS.................................................................................................................... 5
GETTING STARTED.................................................................................................................................................... 5
WHAT’S INCLUDED (WALL MOUNT ADAPTOR)...................................................................................................... 7
ASSEMBLY.................................................................................................................................................................. 8
ASSEMBLY FOR WALL BRACKET EASYTRACK SYSTEM ................................................................................ 8
REQUIRED ELEMENTS........................................................................................................................................ 8
SPECIFICATIONS...................................................................................................................................................... 11
EASYTRACK WALL MOUNT ADAPTOR SPECIFICATIONS.............................................................................. 11
WALL MOUNT ADAPTOR DIMENSIONS........................................................................................................... 11
MAINTENANCE ......................................................................................................................................................... 12
NOTES ....................................................................................................................................................................... 13
GENERAL INFORMATION
WARNING: Failure to understand and follow these instructions may result in injury to
yourself and others.
CAUTION: Failure to follow these instructions may cause damage to the product.
NOTE: This is important information regarding the correct use of the equipment.
WARNING:
Do not operate this equipment without first reading and understanding this
manual.
Should you be unable to understand the warnings, cautions and instructions,
contact your local dealer before attempting to use this equipment. Otherwise
injury or damage may result.
WARNING: Maintenance MUST be performed ONLY by qualified personnel.
SAVE THESE INSTRUCTIONS AND KEEP WITH EASYTRACKAT ALL TIMES.

4
001.10650.EN rev. 6
MANUFACTURER INFORMATION
This product has been manufactured by:
ArjoHuntleigh AB
Verkstadsvägen 5
241 38 Eslöv
SWEDEN
T: +46 413 64500
F: +46 413 64583
W: www.ArjoHuntleigh.com
SAFETY INSTRUCTIONS
NOTE: This instruction manual is for the installation of the Easytrack Wall Mount
Adaptor only. For more information about the Easytrack system, please refer to
the specific Easytrack System Instructions for Use.
WARNING: The Easytrack system and its accessories are intended to be used as an
assistive device for transferring a person between the posts. The Easytrack
system is only to be used with the ArjoHuntleigh Portable lift.
WARNING: Failure to meet requirements listed below could result in serious bodily harm.
REQUIREMENTS
The Wall Mount Adaptor should be installed by a licenced contractor. Installation of the Wall
Mount Adaptor by someone unskilled will void ArjoHuntleigh warranty and may cause
serious injury or damage.
A maintenance check should be done every month to ensure the rail is levelled
(see the "Maintenance" section in this manual).
Protect the Easytrack system and its accessories during transport.
WALL REQUIREMENTS: - WOOD STRUCTURE – MINIMUM 2" X 3" STUDS
- CONCRETE STRUCTURE
DO NOT install if wall does not meet requirements.
DO NOT install on a steel structure.
WARNING: USE ONLY AS INTENDED – This product may cause serious injury if not
installed and operated according to the Instructions for Use.

5
001.10650.EN rev. 6
IMPORTANT SAFETY DIRECTIONS
WARNING: Failure to observe Safety Directions listed below could result in serious injury.
Before you install the Easytrack system:
Carefully inspect product upon arrival. If any component is missing (see Figure 8) or
appears to be damaged, do not install the Easytrack system. Arrange for
repair/replacement of any faulty parts by contacting your local distributor for further
instructions.
If you are unsure of the strength or stability of your wall, do not install the Wall Mount
Adaptor. Consult your local distributor.
Do not install on a wall with water damage.
Do not drop product, because it may cause breakage.
Do not completely submerge the Easytrack system in water.
Do not attempt to over-extend the rail past the locking point.
WARNING: Do not use the Easytrack system as a swing.
Refrain from swinging patient sideways of rail.
GETTING STARTED
Upon receipt of your Easytrack Wall Mount Adaptor:
WARNING: Read the "Requirements" and “Important Safety Directions” sections
before attempting to assemble the Wall Mount Adaptor.
Survey the room where you plan to install the Easytrack Wall Mount Adaptor.
Make sure the room meets all the specifications outlined in the section "Requirements".
Use the measurements below to determine the best place to put the Easytrack system :
Over a bed – approx. 915 – 1020 mm/36 - 40 in from the head of the bed (see Figure
1);
Over a tub – approx. 400 – 460 mm/16 – 18 in from the end of the tub (see Figure 1);
Allow 915 mm/ 36 in of open area for transfer working space (see Figure 2);
Allow a minimum of 1340 mm/53 in from the bottom of the rail to the top of any
object to be transferred over (see Figure 3).
Figure 1 Figure 2
915-1020 mm
[36”-40”] 400-460 mm
[16”-18”]

6
001.10650.EN rev. 6
Figure 3
Transfers should only take place under the Easytrack rail (see Figure 4 and Figure 5).
Figure 4 Figure 5
The Wall Mount Adaptor may be installed on either a concrete wall or wood-framed wall.
For wood, the Wall Mount Adaptor must be attached to a minimum of three (3) 2 X 3 studs.
DO NOT attempt to install the wall mount on less than three (3) studs (see Figure 6).
Figure 6
2130 mm – 2745 mm
[84" - 108"]
W
all mount plate
Studs

W
The Wa
l
the wall
W
HAT’S I
N
Item
1
2
Includes:
3
4
5
6
7
8
+0
l
l Mount
A
and the ra
N
CLUD
E
A
daptor m
u
il will mea
s
E
D (WAL
D
e
Wall
Pivoting
Rou
Pivo
t
M1
0
Loc
k
Fixati
o
B
u
st be pos
i
s
ure more
L MOU
N
e
scription
mount pl
a
rail attac
h
nd blue c
a
t
wall mou
0
x 25 scre
w
k
washe
r
M
1
o
n wall m
o
ack plate
i
tioned on
than 30° (
Figure 7
N
T ADAP
a
te
h
ment
a
p
nt
w
1
0
o
unt
Figure 8
the wall t
o
see Figur
e
TOR)
o
ensure t
h
e
7).
Par
t
21
1
70
0
20
0
00
0
00
0
h
at the an
t
numbe
r
1
.10850
0
.10870
0
.10720
N/A
0
.04090
0
.04425
N/A
N/A
gle betwe
e
Qty
1
1
1
1
4
4
1
1
7
001.10650.EN rev. 6
e
n

8
001.10650.EN rev. 6
ASSEMBLY
ASSEMBLY FOR WALL BRACKET EASYTRACK SYSTEM
WARNING: Read the section "Requirements" and the warnings before attempting to
assemble the Wall Mount Adaptor system.
REQUIRED ELEMENTS
Step ladder
Tape measure
Six (6) concrete 3/8" anchors or six (6) 3/8" lag bolts
Drill
Wrench with a 9/16" socket
Stud finder
Someone to assist you
1) Refer to Figures 9 and 10 below for the distance required between the ceiling and where
the top of the Wall Mount Adaptor must be installed. Please note that when the wall bracket
has the pivoting rail of a 3-post system attached, the mounting point must be lower that a
standard rail.
FOR STANDARD RAIL
FOR PIVOTING RAIL
Figure 9 Figure 10
2) Install the wall plate on the wall. The wall plate must be installed on a concrete wall with six
(6) 3/8 in concrete anchors or on three (3) 2 x 3 (minimum size) wooded studs with two (2)
3/8" dia. (M10) and 4 in long lag bolts on each stud (see Figure 11).
28 mm
[1 1/8"]
133 mm
[5 1/4"]

9
001.10650.EN rev. 6
Figure 11
NOTE: Make sure the rail is levelled before securing it to the wall.
Wood studs: Use a stud finder to find the center of each stud. It is necessary to pre-drill holes
into each stud before screwing the lag bolt to prevent the wood from cracking.
Follow drill size recommendation for lag bolt: LAG BOLT M10 (3/8")
PRE-DRILL SIZE 6.5 mm (1/4")
WARNING: Pre-drilled holes must be in the center of the stud.
If holes are not properly centered, serious damage or injury may occur.
WARNING: DO NOT install steel studs, since reinforcement may be required.
Call your ArjoHuntleigh dealer for more information.
WARNING: Avoid drilling close to any electrical wiring or plumbing. Please make sure
you know what is behind the wall you are drilling in before doing any
modifications to it. Failure to do so may cause serious injury.

1
0
001.10650.EN rev. 6
3
)
4
)
5
)
0
)
Insert th
properly
)
See the
into its fi
rail will
n
)
Tighten
Wall Mo
u
MI
N
e pivoting
(see Figu
r
section "
G
nal positi
o
n
ot, when t
the four (
4
u
nt
A
dapt
o
Bott
N
IMUM A
N
rail attac
h
r
e 12).
G
etting Sta
o
n. For the
urning, ge
4
) bolts o
n
o
r.
om
N
GLE
h
ment into
rted" for s
u
3-post as
s
nerate an
n
pivoting
r
the wall
p
Figure 1
2
u
ggested
p
s
embly, th
angle bey
o
Figure 1
3
r
ail attach
m
p
late. Mak
e
2
p
ositions.
S
e bracket
o
nd the m
a
3
m
ent. The
e
sure tha
t
S
lide the
p
must be p
l
a
ximum al
l
rail can n
t
the brac
k
p
ivoting rai
l
aced in a
l
owed (se
e
ow be att
a
k
et is plac
e
l attachm
e
way that t
e
Figure 1
3
a
ched to t
e
d
e
nt
he
3
).
he

S
P
E
A
W
P
ECIFIC
A
SYTRA
C
SPECIFI
C
Product
c
Capacity
Material
Weight
W
ALL MO
U
ATIONS
C
K WALL
C
ATIONS
c
ode
U
NT ADA
P
MOUNT
A
7
0
2
0
An
1
2
P
TOR DIM
A
DAPTOR
0
0.10860
0
0 kg (440 l
b
n
odised alu
m
2
kg (27 lb
)
ENSIONS
SPECIFI
C
b
)
m
inium an
d
)
Figure 1
4
C
ATIONS
d
steel
4
11
001.10650.EN rev. 6

12
001.10650.EN rev. 6
MAINTENANCE
WARNING: Failure to follow maintenance instructions below when indicated could
result in injury or damage.
WARNING:
Periodic inspection should be performed by a person who is suitable and
properly qualified and well acquainted with the design, use and care of the
Easytrack system. Contact your local dealer/distributor.
Inspection should be carried out routinely (at least as often as specified),
and as necessary. All defects and damages that have lead to corrective
actions should be noted, signed and dated by the inspector. Defects and
resulting actions should be reported to your supplier.
Before each time you use the Easytrack Wall Mount Adaptor:
1. Check that the rail is secured in place. Press the rail upward to make sure that the rail is
locked onto the post.
2. Check if there is any appearance of damage. IF THERE IS ANY APPEARANCE OF
DAMAGE, DO NOT USE THE EASYTRACK SYSTEM.
Every month the following should be done :
1. Clean inside of rail with a damp cloth to ensure there is no dust or grease build-up inside of
rail.
2. Check to ensure you still have all your original parts. If any part is missing, it should be
replaced BEFORE USING THE EASYTRACK WALL MOUNT ADAPTOR AGAIN.
3. Check for the appearance of rust. If rust is starting to appear, simply scrub the piece clean.
Examine all joints and pieces for wear and fatigue. Replace any part that looks damaged or
worn.
4. Keep a log of any repair/replacement/inspection.

13
001.10650.EN rev. 6
NOTES


AUSTRALIA
A
rjoHuntleigh Pty Ltd
78, Forsyth street
O’Connor
A
U-6163 Western Australia
Tel: +61 89337 4111
Free: +1 800 072 040
Fax: + 61 89337 9077
BELGIQUE / BELGIË
A
rjoHuntleigh NV/SA
Evenbroekveld 16
B-9420 ERPE-MERE
Tél/Tel: +32 (0) 53 60 73 80
Fax: +32 (0) 53 60 73 81
E-mail: [email protected]
CANADA
A
rjoHuntleigh Canada Inc.
1575 South Gateway Road
Unit "C"
MISSISSAUGA, ON, L4W 5J1
Tel/Tél: +1 905 238 7880
Free: +1 800 665 4831 Institutional
Free: +1 800 868 0441 Home Care
Fax: +1 905 238 7881
E-mail: [email protected]
ČESKÁ REPUBLIKA
A
rjoHuntleigh s.r.o.
Hlinky 118
CZ- 603 00 BRNO
Tel: +420 549 254 252
Fax: +420 541 213 550
DANMARK
A
rjoHuntleigh A/S
Vassingerødvej 52
DK-3540 LYNGE
Tel: +45 49 13 84 86
Fax: +45 49 13 84 87
E-mail: [email protected]
DEUTSCHLAND
A
rjoHuntleigh GmbH
Peter-Sander-Strasse 10
D-55252 MAINZ-KASTEL
Tel: +49 (0) 6134 186 0
Fax: +49 (0) 6134 186 160
E-mail: [email protected]
ΕΛΛΑΔΑ
C. Psimitis Co Ltd
Dimitriou Andr. 59
GR-16121 KAISARIANI ATTIKIS
Τηλ: 21 0724 36 68
Φάξ: 21 0721 55 53
ESPAÑA
A
rjoHuntleigh Ibérica S.L.
Ctra. de Rubí, 88 1ª planta - A1
08173 Sant Cugat del Vallés
ES- BARCELONA 08173
Tel: +34 93 583 11 20
Fax: +34 93 583 11 22
E-mail: [email protected]
FAR EAST
ARJO Far East Limited
Unit 3A, 4/F., block B Hoi Luen
Industrial Centre
55 Hoi Yuen Road,
Kwun Tong, Kowloon
HONG KONG
Tel: +852 2508 9553
Fax: +852 2508 1416
FRANCE
ArjoHuntleigh SAS
2 Avenue Alcide de Gasperi
BP 133
59436 RONCQ CEDEX
Tél: +33 (0) 3 20 28 13 13
Fax: +33 (0) 3 20 28 13 14
INTERNATIONAL
ArjoHuntleigh International Ltd.
ArjoHuntleigh House
Houghton Hall Park
Houghton Regis
UK-DUNSTABLE LU5 5XF
Tel: +44 (0) 1582 745 800
Fax: +44 (0) 1582 745 866
E-mail:
ITALIA
ArjoHuntleigh S.p.A.
Via di Tor Vergata 432
00133 ROMA - ITALIA
Tel: +39 (0) 6 87426211
Fax: +39 (0) 6 87426222
E-mail: [email protected]
NEDERLAND
ArjoHuntleigh Nederland BV
Biezenwei 21
4004 MB TIEL
Postbus 6116
4000 HC TIEL
Tel: +31 (0) 344 64 08 00
Fax: +31 (0) 344 64 08 85
E-mail: [email protected]
NEW ZEALAND
ArjoHuntleigh Ltd
41 Vestey Drive
Mount Wellington
AUCKLAND 1060
Tel: +64 (0) 9 573 5344
Free Call: 0800 000 151
Fax: +64 (0) 9 573 5384
E-mail: [email protected]
NORGE
ArjoHuntleigh Norway AS
Ryenstubben 2
NO-0679 OSLO
Tel: +47 22 08 00 50
Faks: +47 22 08 00 51
E-mail: [email protected]
POLSKA
ArjoHuntleigh Polska Sp. z o.o.
ul. Ks Piotra Wawrzyniaka 2
PL 62-052 KOMORNIKI (Poznan)
Tel: +48 61 662 15 50
Fax: +48 61 662 15 90
E-mail: [email protected]
PORTUGAL
ArjoHuntleigh em Portugal:
MAQUET Portugal, Lda. (Distribudor Exclusivo)
Rua Poeta Bocage n.º 2 - 2G
1600-233 Lisboa, Portugal
Tel: +351 214 189 815
Fax: +351 214 177 413
E-mail: [email protected]
SUISSE / SCHWEIZ
ArjoHuntleigh AG
Fabrikstrasse 8
Postfach
4614 Hägendorf,
Tél/Tel: +41 (0) 61 337 97 77
Fax: +41 (0) 61 311 97 42
SUOMI
ArjoHuntleigh OY
Vanha Porvoontie 229
FI-01380 VANTAA
Puh: +358 9 4730 4320
Faksi: +358 9 4730 4999
SVERIGE
ARJO Scandinavia AB
Verkstadsvägen 5
Box 61
SE-241 21 ESLÖV
Tel: +46 (0) 413 645 00
Fax: +46 (0) 413 645 83
E-mail: [email protected]
UNITED KINGDOM
ArjoHuntleigh UK
ArjoHuntleigh House
Houghton Hall Park
Houghton Regis
UK-DUNSTABLE LU5 5XF
Tel: +44 (0) 1582 745 700
Fax: +44 (0) 1582 745 745
E-mail:
USA
ArjoHuntleigh Inc.
2349 W Lake Street Suite 250
Addison, IL 60101
Tel: +1 630 307 2756
Free: +1 800 323 1245 Institutional
Free: +1 800 868 0441 Home Care
Fax: +1 630 307 6195
E-mail: [email protected]
ÖSTERREICH
ArjoHuntleigh GmbH
Dörrstrasse 85
AT-6020 INNSBRUCK
Tel: +43 (0) 512 204 160 0
Fax: +43 (0) 512 204 160 75
www.arjohuntleigh.com

www.ArjoHuntleigh.com
GETINGE GROUP is a leading global provider of products and systems that
contribute to quality enhancement and cost efficiency within healthcare and life
sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and
MAQUET. ArjoHuntleigh focuses on patient mobility and wound management
solutions. GETINGE provides solutions for infection control within healthcare and
contamination prevention within life sciences. MAQUET specializes in solutions,
therapies and products for surgical interventions and intensive care.
ArjoHuntleigh AB
Verkstadsvägen 5
241 38 Eslöv
SWEDEN
Table of contents