Dear Customer!
Please read this user manual carefully before using the ARPACK AirClean AC 40 device.
1. Intended purpose and recommendations on use
The device is intended for disinfection (bactericidal and virucidal activity) and air purification from volatile organic
compounds (odours) after their photocatalytic mineralisation on a nanocrystalline titanium dioxide affected by
UV radiation in the wavelength range A (365 nm).
The main types of volatile organic compounds removed by the product are as follows:
■bacteria, viruses, mould spores;
■hydrocarbons of a series of methane and ethylene;
■aldehydes, esters, ketones;
■aromatic hydrocarbons;
■herocyclic carcinogens;
■allergens;
■ozone and active forms of oxygen;
The device can be used at home, in medical facilities, schools and boarding schools, hotels and apothecaries,
offices, service rooms, production and warehousing facilities with a recommended surface area of no more than
28 m2. The product is most efficient in enclosed, poorly ventilated spaces with high microbiological
contamination, e.g.:
•Resuscitation and bedridden units;
•Laboratories with operational microbiological facilities;
•Spaces with large amounts of plastics, household chemical agents and objects
emitting phenol and formaldehyde (e.g. furniture made from particle board).
The device can be used in the presence of people, animals and plants, and is intended for continuous operation.
2 | ARPACK GmbH

EN
Table of contents
1. Purpose and recommendations on use................................................................................................(p. 2)
2. Recommendations on use ....................................................................................................................(p. 3)
3. Information on the device ....................................................................................................................(p. 4)
4. Safety....................................................................................................................................................(p. 4)
5. Safety guidelines...................................................................................................................................(p. 7)
6. Scope of delivery/transport..................................................................................................................(p. 9)
7. Functionality / operation....................................................................................................................(p. 10)
8. Technical data.....................................................................................................................................(p. 14)
9. Warranty.............................................................................................................................................(p. 15)
10. Storage................................................................................................................................................(p. 15)
11. Recycling and disposal........................................................................................................................(p. 16)
12. Declaration of conformity...................................................................................................................(p. 17)
3Information on the device
■Please read this document prior to commencing work.
■Comply with the guidelines specified in this document.
Otherwise, the warranty claim against ARPACK GmbH will expiry.
3.1 Document validity
This document concerns the ARPACK AirClean air purification devices.
3.2 Target group
This document is dedicated for the air purification device operator or user.
3.3 Storage of documents
Documents must be kept in an adequate location and must be readily available. The device’s user is
responsible for keeping all documents.
3 | ARPACK GmbH

EN
4 Safety
■Works on the air purification device can only be performed by qualified personnel.
■Works on electrical components in accordance with VDE 0105 part 1 can only be performed by qualified
electrical engineers.
■The regulations on accident prevention (UVV) must be observed during the works.
■Pay attention to labels placed on the air purification devices and its components.
4.1 Use
Use as intended
The ARPACK AirClean AC 40 air purification device is a ventilation and air-conditioning device that can
neutralise viruses, germs, bacteria, spores and micro-fibres (e.g. paper and textile) as well as unpleasant
odours.
This allows the device to shorten the presence and lessen the concentration of the aerosol and suspension
cloud in the room in which the device is installed.
The AirClean AC 40 air purification device is intended for filtering or purification of normal air in rooms. The
device is intended for internal installation in frost-resistant rooms. It is mainly intended for air purification in
locations such as schools, kindergartens and nurseries,, but also in bedrooms, restaurants, waiting rooms,
offices, halls, common rooms, etc.
Compliance with the delivered user manual as also classified as intended use!
The device can be used by children aged above 8 and older, and by persons with impaired physical, sensory or
mental abilities, or persons without experience and knowledge, provided that they are supervised or were
instructed on the safe use and they understand the related hazards. Children cannot play with the device.
Cleaning and maintenance can only be performed by persons aged 18 and above.
Improper use
Uses other than those specified above are deemed improper. It is especially forbidden to use the device in
external areas, in rooms with high humidity (constantly above 65±15% relative humidity), high dust levels,
with aggressive or explosive atmospheres. It is forbidden to introduce structural changes or use the device
improperly. ARPACK GmbH is not liable for the resulting damage. Liability and risk shall be borne solely by the
user.
4 | ARPACK GmbH

EN
4.2 Safety measures
Do not remove, combine or otherwise disable protective and monitoring devices. The device must only
be used when in perfect technical condition. Failures and damage that negatively affect or that may
affect safety must be promptly removed in a professional manner.
■Damaged structural elements must be replaced with original ARPACK spare parts.
■Original ARPACK spare parts can be obtained within a short time via e-mail at
It is forbidden for the user to make self-repairs.
Warranty or service request must be placed via telephone at +49 800 22 33 889 or via e-mail
4.3 General information on safety HAZARD
Voltage!
Death resulting from electrocution.
■Do not open the device
■Delegate electrical works to professionals
■Regularly check electrical elements, such as cables and plugs, and delegate defect repairs to
professionals
4.4 Guidelines/recommendations for the device operator
■Inspection and maintenance in accordance with chapter 7.5
■Repairs must only be delegated to professionals
■Use only original ARPACK spare parts.
■Do not introduce any technical changes in the air filter or the control system elements.
■This manual and co-binding documents must be kept carefully and in an appropriate location. They should be
readily available at any time.
5 | ARPACK GmbH

EN
4.5 Declaration of conformity
Declaration of conformity (see chapter “12 Declaration of conformity) This product complies with the
European directives and domestic requirements.
6 | ARPACK GmbH

EN
5Safety guidelines
5.1 General information
This manual only applies to the operation of the ARPACK AirClean AC 40 air purification device.
The personnel appointed to perform appropriate work prior to start-up or maintenance must be
acquainted with this manual. The guidelines specified in this manual must be observed. This manual
must be kept in a readily available location as a component of the delivered device.
If the user manual is not observed, the warranty claim against ARPACK GmbH will expiry.
5.2 Notification signs
The following notification signs and symbols are used in this manual.
These important instructions concern the personal and technical protection for operational safety.
SAFETY GUIDELINE
A safety information means instructions that must be strictly observed
to avoid hazards and injuries to people and damage to the device.
HAZARD
Hazard due to voltage on electrical components!
Attention: Disable the operating switch before removing the housing. Do not
touch the electrical components and contacts when the operating switch is
enabled!
There is a risk of electrocution harmful to health or a risk of death. The
connection terminals are live even when the operating switch
is disabled.
The information means technical instructions that must be observed to avoid
damage to the device or its defects.
Apart from the user manual, the device features guidelines/instructions in the
form of labels that must also be observed.
7 | ARPACK GmbH
INFORMATION

EN
Works on the electrical system can only be performed by qualified electrical engineers. In
the case of electrical engineering works, the VDE regulations and the regulations of the
local power supply company (EVU) apply.
HAZARD
The device can only be operated in the efficiency range specified in
the ARPACK technical documentation. The device can only be operated
in a perfect technical condition. Defects and damage that affect or
that may affect safety or the correct operation of the device
must be promptly removed in a professional manner.
Only air can be pumped by the device.
The air cannot include any harmful, flammable, explosive,
aggressive, corrosive or otherwise hazardous components, otherwise
the substances would be disseminated in the room, thereby posing
a health or life hazard for the people, animals or plants present in the room.
During the device’s installation, the general regulations on accident
prevention (UVV) must be observed.
5.4 Fire
The device itself does not pose a direct fire hazard.
5.5 Warnings
It is forbidden to remove or disable protective and monitoring devices! The device can only be operated in a
perfect technical condition. Defects and damage that negatively affect safety must be promptly removed.
8 | ARPACK GmbH
5.3 Safety instructions
HAZARD

EN
Scope of delivery and transport
Open the packaging and make sure that the device does not feature visible transport
damage. The scope of delivery includes the following:
-1 ARPACK AirClean AC 40 air purification device
-1 wall mount + assembly material
-1 stand + assembly material
-1 user manual
In case of any damage to the damage, notify the vendor immediately.
Fig. 1 Condition at the time of delivery
Assembly
material
Air
purification device
Stand
Stand
9 | ARPACK GmbH

EN
7 Functionality / Operation
7.1 Functionality
The device’s functionality is based on the
photocatalytic oxidation of volatile organic
compounds on the surface of nanocrystalline
titanium dioxide affected by UV-A radiation. The
contaminated air reaches the photocatalytic
treatment area through convective air flow or air
streams that are generated by the heat released
from the UV-A diodes (Fig. 2). The pollutants,
bacteria and viruses are absorbed from the
surfaces of photocatalytic elements and are mainly
mineralised into carbon dioxide and water vapours
due to the UV-A diodes’ light.
Photocatalytic
elements
UV-A LED
Housing
Power feeder
Power feeder
Switch
Fuse
Fig. 2 Device presentation
10 | ARPACK GmbH
Air flow

EN
7.2 Operation
It is necessary to select the device’s installation location. The location may include a floor, shelf, table or
other adequate structure. The device should not constitute a hindrance and should be protected against
overturning.
7.2.1 Stand
Mount the stand on the device using the adequate screws (Fig. 3). Prior to first start-up, make sure that the
device is heated up to the room temperature and that no condensation occurs. Pay attention to the
following aspects when starting up the device:
•The device is supplied with the mains voltage of 220V/50Hz.
•The device’s working position is the vertical position.
•The device’s ventilation openings are always open (Fig. 3).
•The device is started up by pressing the switch.
•The device is heated up and enters the operating mode after approx. 20 minutes from start-up.
7.3 Equipment and operating specification
The device’s housing is made from steel sheets and is powder coated.
The device’s lower part features a lever switch and a replaceable fuse. The housing’s interior features a flat
photocatalytic element based on porous quartz glass and a LED-UV-A emitter with a power feeder.
The device’s operation is silent and the device does not require regular replacement of the photocatalytic
elements, because they are not contaminated with dust particles during operation.
11 | ARPACK GmbH

EN
7.4 Preparation for operation and exploitation
Recommended procedure for floor stand fixing:
•Place the device
with its front side downwards
on a horizontal
surface (Fig. 3).
•Mount the
stand to
the housing using
the M3 screws.
Fig. 3 Stand installation
Recommended procedure for wall mount fixing:
-Fix the wall mount (2) to the wall using the provided screws and dowels.
-Screw the provided rubber legs (3) into the threaded openings in the device’s rear side.
-Carefully hang the device on the wall mount and make sure that it is safely mounted.
12 | ARPACK GmbH
Switch
Fig. 4 Lever switch

EN
7.5 Maintenance and maintenance intervals
It is recommended to wipe the device’s outer surface regularly with a moist cloth. For
disinfection, it is possible to use a 3% hydrogen peroxide solution with 0.5% synthetic detergent
or 1% chloramine solution.
During longer breaks in operation, the device must be placed in a location with minimum
exposure to dust; prevent permeation of dust through the ventilation openings.
Only qualified personnel can perform the device’s maintenance.
Do not use acetone or liquids with acetone to wipe the device.
13 | ARPACK GmbH
It is forbidden to spray the device with aerosol for “testing” purposes.
This leads to shock concentrations of organic pollutants. The regeneration and resumption
of normal photo catalyser operation can take up to several days.
Connect the power cable to a domestic socket 230 V and 50 Hz. Start up the product using the lever switch (Fig.
4).
During start-up, the housing’s top rectangle opening will feature a light-blue lamp that signals the activation of
the UV-A LED emitter.
The device is heated up and enters the operating mode after approx. 20 minutes from start-up.
The continuous mode is the recommended operation mode.
The product is stopped using the lever switch. If a longer standstill period is planned, it is recommended to
disconnect the power cable from the socket. The continuous mode is the recommended operation mode.
The product is stopped using the lever switch. If a longer standstill period is planned, it is recommended to
disconnect the power cable from the socket.

EN
8Technical data
Model
Arpack AirClean AC 40
Parameters
Values
Maximum purification capacity in m3/h
approx. 20
Recommended maximum room size in m2
<28
Glass-based photocatalytic filter with TiO2
+
Complete mineralisation without accumulation of efficient organic airborne
pollutants and pathogenic microflora on the photocatalytic filter
+
Capacity to remove volatile organic compounds in mg/min
approx. 14
Maximum noise emission in dB
0
UV-A body’s safe operating range in nm
315-400
Ozone generation
none
Mains connection in V / Hz
220 (+/-10%) / 50
Dimensions: W x H x D in mm
255 x 995 x 50
Total weight in kg
10.8
Preferred operating mode
continuous
Maximum energy consumption in W
120
Warranty period in months
24
Wall and floor mountable
+
14 | ARPACK GmbH

EN
9Warranty
The product is covered by a 24-month warranty from the date of purchase.
The manufacturer is not liable for the product’s failure in the following cases:
•Incorrect storage, operation and transport by the owner
•Failure to comply with the operation regulations
•The device is repaired by companies explicitly not authorised by the manufacturer
•Using the device in mains with voltage fluctuations exceeding the normal values
•In case of defects that can derive from incorrect or intentional actions
•In case of defects resulting from structural changes
•In case of the device’s failure due to force majeure events
•In case of damage caused by penetration of foreign bodies or liquids
•In case of mechanical damage
10 Storage
In case of devices packaged in film, we recommend removing the film immediately after delivery. The film
only constitutes transport packaging for short-term device protection. The film is not suitable for long-term
device storage, because films usually favour the formation of condensate and thereby corrosion. If the device
is not installed immediately after delivery, it is necessary to store it in a dry room resistant to atmospheric
conditions, protect it (with suitable packaging) and place it on an even, horizontal surface keeping the stand
safe. It is especially important to prevent damage and negative impact caused by weather conditions
(moisture, temperature, dust, dirtying) and external factors (impact, animals, rodents). The device’s openings
must be tightly sealed.
15 | ARPACK GmbH

EN
11 Packaging and disposal
Never dispose of the device with household wastes!
According to the Act on waste disposal, the following elements must be disposed of and recycled in an
environmentally-friendly manner via certified collection points:
•Old device
•Wear parts
•Defective elements
•Electrical or electronic scrap
Environmentally-friendly means classified by material groups to achieve the maximum possible use of primary
materials with the lowest environmental burden.
•Cardboard packaging, plastics intended for recycling and filling materials from plastics
must be disposed of in an environmentally-friendly manner via adequate recycling
systems or waste collection points.
•Comply with relevant domestic or local regulations.
•The collection service is available via telephone at 0800/ 22 33 88 9 or via e-mail at: [email protected]m
We strive to protect the environment and to achieve sustainable development.
Do not dispose of the device with household wastes.
Send the device to the manufacturer, which covers the costs.
16 | ARPACK GmbH
Attention!

EN
Declaration of conformity
- Original declaration of conformity -
EC/EU Declaration of conformity
Product: Air purification and disinfection device
Product data: Product Type no.
Arpack Air Clean AC 20/AC 40 See nameplate
Year of manufacture: acc. to the nameplate
Issuing body: Arpack GmbH
Askanischer Platz 4, 10963 Berlin
Federal Republic of Germany
Legal bases: EN ISO 14120:2016
EN ISO 12100:2011
EN ISO 13857:2020
EN ISO 13854:2020
EN 60335-1 : 2012 + AC:2014 + A11:2014
EN 60335-2-65 : 2003 + A1:2008 + A11:2012
EN 61000-6-3 : 2007 + A1:2011
EN 61000-6-2 : 2019
EN 55014-1 : 2006 + A1:2009 + A2:2011
EN 55014-2 : 1997 + A1:2001 + A2:2008
EN 55015 : 2006 + A1 : 2007 + A2 : 2009
EN 61000-3-2 : 2014
EN 61000-3-3 : 2013
EN 62233 : 2008
EN 51547 : 2009
We hereby declare that the aforementioned product covered by this declaration
complies with Appendix III of the EU Directive 2004/108/EC, i.e. with the current
provisions of the aforementioned legal regulations in their latest edition.
Berlin, 17.03.2021
Mark Arinstein
Managing Director
17 | ARPACK GmbH

EN
18 | ARPACK GmbH
Table of contents
Other ARPACK Air Cleaner manuals