9
GAS CONNECTION - NATURAL GAS (NG)
NEVER CONNECT THE POWER BURNER TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for natural gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury. The installation of this appliance must conform with
local codes or, in the absence of local codes, to the national fuel gas code, ANSI Z223.1a-1988. Installation in
Canada must be in accordance with the Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-
B149.2, Propane Installation Code.
• ARTP-PB 60,000 BTUH
Manifold pressure with NG: Operating: 5.0” W.C. (.14 PSI)
Non-operating: 5.5” W.C. (.16 PSI)
Optimum pressure: 7.0” W.C. (.25 PSI)
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply pressure is ad-
equate (7.0” W.C. supply pressure is preferred) to maintain 4.5” W.C. manifold pressure.
Use a minimum 1/2” ID flex hose to prevent gas starvation.
NATURAL GAS CONNECTION:
Ensure that the service pipe supplying the Power Burner is fitted with a shut off valve conveniently positioned
and easily accessible as an emergency gas shutoff.
Your Artisan™ Power Burner for use with Natural Gas comes equipped with its own regulator which MUST
NOT be removed.
If this regulator needs to be replaced use only the type specified by Artisan™ for this appliance.
! CAUTION
CYLINDERS MUST BE STORED OUTDOORS IN A
WELL VENTILATED AREA OUT OF THE REACH OF
CHILDREN.
DISCONNECTED LP CYLINDERS MUST HAVE THREADED
VALVE PLUGS TIGHTLY INSTALLED, AND MUST NOT BE
STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED
AREA. THE GAS MUST BE TURNED OFF AT THE SUPPLY CYL-
INDER WHEN THE UNIT IS NOT IN USE. IF THE APPLIANCE IS
STORED INDOORS, THE CYLINDER MUST BE DISCONNECTED
AND REMOVED FROM THE APPLIANCE.
! WARNING
YOUR ALFRESCO™ AXEVP PRESSURE
REGULATOR HAS A MAXIMUM INPUT
PRESSURE OF 14” WC. (OR APPROX. .5
PSI) , AND A SAFETY LIMIT OF 69” WC.
(2.5 PSI).
! REGULATOR NOTICE
Exposure to pressures above the safety
limit of 69” WC. will permanently damage
the gas regulator requiring a replacement.
OVER PRESSURE DAMAGE IS NOT
COVERED BY YOUR ALFRESCO
! MISE EN GARDE
LE CYLINDRE DOIT ÊTRE STOCKÉ À L'EXTÉRIEUR
DANS UN ENDROIT BIEN VENTILÉ ET HORS DE LA POR-
TÉE DES ENFANTS.
DÉBRANCHER LES BOUTEILLES DE LP DOIVENT
AVOIR DES BOUCHONS DE VALEUR VISSÉS
HERMÉTIQUEMENT INSTALLÉS, ET NE DOIVENT
PAS ÊTRE STOCKÉS DANS UN BÂTIMENT, GARAGE
OU TOUT AUTRE ESPACE FERMÉ. LE GAZ DOIT
ÊTRE ARRÊTÉ AU NIVEAU DU CYLINDRE D'ALIMEN-
! AVERTISSEMENT
VOTRE RÉGULATEUR DE PRESSION AL-
FRESCO GOURMET GRILLADES A UNE
PRESSION D'ENTRÉE MAXIMALE DE 14"
WC (OU ENVIRON 0,5 PSI), ET UNE LIM-
ITE DE SÉCURITÉ DE 69" WC (2,5 PSI).