Foreword
This manual is used with P900 Controller version. It contains all technical information pertaining to the
installation of the access control system: wiring requirement, connection to devices and controller
parameter settings.
ASIS Technologies reserve the right to change product design at any time for product improvement.
Information in this manual is subjected to change without further notice.
ASIS Technologies make all efforts to ensure this Manual is up to date and corresponds to the product
being shipped. However, ASIS Technologies assumes no responsibility for any errors that may occur in
this manual.
This manual contains proprietary information that is protected by copyright. Neither this manual nor any
part of it may be reproduced, photocopied, translated, or electronically transmitted in any way without the
prior written permission of ASIS Technologies.
For enquiries and support in installing the P900 Controller, please contact ASIS Technologies or any
representative in your region.

Limited Warranty
ASIS Technologies warrants its products to be defect free in material and workmanship when they have
been installed in accordance with the manufacturer’s instructions.
The warranty will not apply if the product is tampered with or misused, unauthorized modification and
improper maintenance. Consumables items, such as batteries, have no warranty.
ASIS Technologies does not assume any responsibility for damage or injury to person or property due to
improper care, storage handling, abuse, misuse, normal wear and tear, or an act of God.
The product warranty shall expire one (1) year after shipping date. Except as stated above, ASIS
Technologies makes no other warranty or condition, whether written or oral, expressed or implied, as to
any matter whatsoever, including their merchantability, or fitness for any particular application.

Table of Contents
Foreword 2
Limited Warranty 3
Table of Contents 5
1.1 P900 Professional Series Web Based Controller Overview 8
Controllers 8
Features 8
I/O onboard 8
Wiegand port on boards 8
Max Reader Support 8
Modular subunits 8
1.2 Key Features of P900 family Professional Controller 9
1.3 Note to Installation 17
1.4a Dual Redundant Controller setup connectivity Diagram 18
1.4b Single Controller with addon board (Type A) 18
1.4c Single Controller with addon board (Type B) 18
1.5 Network Connectivity Diagram for P901 19
1.6 Network Connectivity Diagram for P908 and Modules 20
1.6 Power and Data Connectivity for P908 21
1.8 Product Specification 22
2.2 All in one Enclosure 26
2.3 All in one Enclosure Dimension 28
3.1 Powering P908 31
3.2 Battery Backup 31
3.3 Power up P908 and Status Indicators 32
4.1 P908 Wiegand Interface 36
4.2 P908 RS-485 Reader Interface 38
5.1 Cluster Anti-Passback (APB) 41
5.2 Anti-Passback Mode 41
5.3 Arm Mode Setting 42
5.4 High Security Door Setting 44

5.5 Other Door Settings 45
5.6 Lift Controller Operation 46
5.7 Modular Fire Alarm 47
6.1 Input Configuration 49
6.2 Input Type 49
6.3 Supervised Input 49
6.4 End of Line Resistor 50
6.5 Non-Supervised Input 52
6.6 P90x Input Setting 52
6.7 Input Arm Setting 53
7.1 Output Connection 56
7.2 Output Select for Relay 57
7.3 Output Mode 58
8.1 P90x/ P91x /P9x0 Addressing 65

Introduction

Page | 8
1.1 P900 Professional Series Web Based Controller Overview
P900 is a family name for a range of Professional Series, Card Access and Intrusion
monitoring Controllers. Different configurations of controllers are available, and different
modular addon subunits are in the families.
Controllers
Features
I/O onboard
Wiegand
port on
boards
Max
Reader
Support
P901
Dual
redundant
controller
n/a
n/a
n/a
P904
Single mode
controller
16/4
4
8
P908
Single mode
controller
24/12
8
12
Modular
subunits
P914
Addon
Reader and
I/O
16/4
4
8
P918
Addon
Reader and
I/O
24/12
8
12
P920
Addon I/O
32/8
n/a
P930
Addon I/O
8/32
n/a
Relationship between a Controller and Module is one to Many, even in the case of P901
where two units must be connected to work, as at any given time only one P901 is online.
The connected module will not know the presence of a second Controller.

Page | 9
1.2 Key Features of P900 family Professional Controller
●From dual redundant controller to expandable to 32-doors
●Navikey for setup and diagnostic at controller panel and quick credential enrolment
●Input Output only expandable module
●Reader Interface (ADNET,OSDP & Wiegand)
●Support 32x Readers via Wiegand or 64 x Readers via RS485
●150,000 cardholder capacity
●2,500,00 event buffer
●Build in report generator with PDF,CSV file export
●Floor Plans with real-time status icon
●“InstaSTART” button for easy and quick setup
●Platform independent, compatible with IE,Firefox,Safari.Chrome,etc
●Non-SPOF design with FailOver Controller, Redundancy Ethernet and Redundant
CANbus link
●AES and SHA1 encryption communication to Host
●Simple Wiring Diagram
●Compatible with IBSS.web
●Cluster Anti Passback
Expandable from 8 doors to network of 32 doors:
●Networking with CAN bus for up to 32 doors
●Interface to advanced Windows server based Security Management software
(IBSS.web)
State of the art design assures long term investment protection:
●Flash memory design for easy upgrade of controller software

Page | 10
P901 has no readers, input or output terminal points. It is a barebones controller with CAN BUS, and LAN
Port connection. P901 can link up with a second P901 thru Ethernet to form dual redundant controller
systems. Modular subunit (P914,P918,P920,P930,P940) link up thru CAN bus to form a complete
network. Navikey mounted on the controller displays vital functional information of the controller. It
doubles up as enrollment readers when necessary.

Page | 11
P904 supports 8 readers in RS485, 16 inputs, 4 outputs terminal points. It comes with CAN BUS, and
LAN Port connection. Modular subunit (P914,P918,P920,P930) link up thru CAN bus to form a complete
network. Navikey mounted on the controller displays vital functional information of the controller. It
doubles up as enrollment readers when necessary.

Page | 12
P908 supports 16 readers in RS485, 24 inputs, 12 outputs terminal points. It comes with CAN BUS, and
LAN Port connection. Modular subunit (P914,P918,P920,P930) link up thru CAN bus to form a complete
network. Navikey mounted on the controller displays vital functional information of the controller. It
doubles up as enrollment readers when necessary.

Page | 13
Submodule P914 supports 8 readers, 16 inputs, 4 outputs terminal points. It comes with CAN BUS to
communicate with the controller, A total of 3x P914 can be added to the controller.
Submodule P918 supports 16 readers, 16 inputs, 4 outputs terminal points. It comes with CAN BUS to
communicate with the controller, A total of 3x P918 can be add to the controller.

Page | 14
Submodule P920 has 0 readers, 32 inputs, 8 outputs terminal points. It comes with CAN BUS to
communicate with the controller, A total of 4x P920 can be add to the controller.

Page | 15
Submodule P930 has 0 readers, 8 inputs, 32 outputs terminal points. It comes with CAN BUS to
communicate with the controller, A total of 4x P920 can be add to the controller.

Page | 16

Page | 17
1.3 Note to Installation
The Installation and Mounting should observe the following:
●The controller should be kept at least 6 feet from any other RF emitting device.
●The controller should be mounted away possible of water leaking location or if in exterior
location sealed to prevent water from seeping into the electronics.
●The controller should be protected from extreme heat and sunlight.

Page | 18
1.4a Dual Redundant Controller setup connectivity Diagram
1.4b Single Controller with addon board (Type A)
1.4c Single Controller with addon board (Type B)

Page | 19
1.5 Network Connectivity Diagram for P901
*mixture of max 4 units of P920/P930 is supported
P901 dual redundancy single line connectivity, P901 does not have any I/O or reader ports. Its
primary function is to provide Controller dual redundancy. It serves CAN bus connected Modules for
Access and Intrusion purposes.
Figure 1.3 Single Line Drawing Connectivity for P901 dual redundant controller

Page | 20
1.6 Network Connectivity Diagram for P908 and Modules
*mixture of max 4 units of P920/P930 is supported
Figure 1.4 Single Line Drawing Connectivity for P908,P918,P920,P930
Table of contents
Popular Controllers manuals by other brands

Hydrofarm
Hydrofarm Active Aqua Grow Flow instruction manual

Allen-Bradley
Allen-Bradley controllogix 1756-L61 Programming manual

CBS ArcSafe
CBS ArcSafe RSA-138A Installation and operation

Norac
Norac UC5 Topcon X30 installation manual

Mitsubishi Electric
Mitsubishi Electric MELSEC-F FX-16E-TB user guide

GYS
GYS STARTPACK 12.24 CI instructions