Atlas CP700 User manual

CP700 Commercial Power Amplifier
HIGH-PERFORMANCE, DUAL-CHANNEL, COMMERCIAL AUDIO AMPLIFIER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
2
TABLE OF CONTENTS
Introduction, Features, Applications.............................................................………………………………….3
Front Panel Description......................................................................…………………………………..…….4
Rear Panel Description......................................................................…………………………………..……..5
Input Wiring......................................................................…………………………………..…………………..7
Speaker Output Wiring...................................................................................………………………………..9
Specifications..........................................................................................…………………………………….15
Warranty................................................................................................……………………………………...16
SAFETY INSTRUCTIONS
Please Read Carefully Before Installing or Operating This Product
• Read instructions fully.
• Pay attention to any and all warnings.
• Connect this amplifier only to the correct operating voltage.
• Do not attempt to service this unit. Only a qualified service technician should open this unit for
servicing.
• Warning - To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.
HEARING DAMAGE!
All professional loudspeaker systems are easily capable of producing very high sound pressure levels.
Use care with the operation of this amplifier and wear the appropriate hearing protection. Exposure to
excessive sound pressure levels can cause permanent hearing damage.
SHOCK HAZARD!
The Atlas Sound CP700, when in operation, can produce a shock hazard at the speaker terminals.
Make sure the amplifier is turned off when installing or removing connections at the speaker terminal
barrier strip. After connecting the proper speaker load, REPLACE the terminal strip cover!
VENTILATION
Although the CP700 is fan cooled and has thermal protection circuitry, allow adequate ventilation to
assure trouble free operation. When rack mounting one or more of the CP700s, install an exhaust fan in
the rack to evacuate heat buildup. Consult Atlas Sound’s Technical Support at 1-800-876-3333 for advice
on thermal management and help with rack selection for this product.
RACK MOUNTING
Although the internal output transformers are mounted close to the front panel when rack mounting the
CP700, be sure the unit is adequately supported.

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
3
INTRODUCTION
Congratulations and thank you for purchasing the Atlas Sound CP700 dual channel power amplifier. This
product is a professional grade audio power amplifier specifically designed for demanding contractor
applications and engineered to provide years of faithful service. Two independent channels driven by
separate power supplies ensure maximum channel separation and ultra low distortion figures. Whether
your application is a large distributed constant voltage sound system or a high SPL sound reinforcement
system, the Atlas Sound CP700 is the answer for high power/low cost amplification needs.
FEATURES
• Independent power supplies
• Soft clip limiter protection
• Dual-speed, high efficiency fan cooling
• Stepped attenuators mounted on the rear for security
• Stereo, bridge, or parallel operating modes selectable via rear mounted switch
• Balanced inputs on barrier strip and XLR connectors
• Loop through feature on male XLRs, one per channel input
• Short-circuit, temperature, and DC offset protection
• 25V, 70.7V, 100V, and direct coupled (2,4, and 8 Ohm) outputs mounted on barrier strips with covers
for safety
• Toroidal output transformers provide extended high frequency response and effectively lower the
electrical interference
• Power-up muting
APPLICATIONS
The Atlas CP700 is the perfect choice for distributed paging/BGM systems, foreground music systems, and
distributed sound masking applications. It is also at home in night clubs, theaters, portable sound systems,
and anywhere clean high-fidelity audio amplification is needed.

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
4
FRONT PANEL DESCRIPTION
Figure 1
1. Power Switch
This rocker switch supplies power to the CP700 amplifier. A red LED located above the power switch
will illuminate when the CP700 is switched on.
2. Protect LED Indicators
The CP700 features several types of protection circuitry to prevent damage during turn-on or fault
conditions. If any of these LEDs illuminate, one of the various protection features is safeguarding the
amplifier. The output relays will disconnect the speaker loads when the protection circuitry detects a
fault condition.
•Loudspeaker Protection - When power is first applied, the speaker protection relay is
open, preventing transients from reaching the loudspeakers. After the internal power supplies
have stabilized, the relay will close, connecting the amplifier output to the load. The yellow
Protect LEDs will illuminate during this power up process.
•Thermal Protection - The CP700 protection circuitry monitors itself for excessive internal
operating temperatures. In the event of this circuitry detecting abnormal thermal conditions
(blocked cooling fan and high ambient temperatures), the speaker relay will disconnect the
speaker load from the amplifier. Once the internal operating temperature drops back to a safe
level, the relay will close, reconnecting the speaker load to the amplifier.
•Short Circuit Protection - The yellow Protect LEDs will illuminate should the amplifier detect
a short circuit on the attached speaker load or if the load impedance is too low. When this
condition is detected, the internal speaker relays will open up, disconnecting the load from
the amplifier. The protection circuitry will stay activated until the fault is cleared.
Note: Once the specific fault has been corrected, the power may have to be cycled to reset the
protection circuitry.
3. Signal "Status" LED Indicator
The green "Status" LEDs will illuminate once the input signal has reached -26dBv or higher.
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
2
3
4
1

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
5
4. Limit LED Indicator
The CP700 comes equipped with limiter circuitry and LEDs to indicate when this circuitry is activated.
The limiter circuitry engages only when the input signals reach a specific, factory set magnitude. Once
this limit has been reached, the circuitry will reduce the input level enough to prevent clipping at the
speaker output terminals.
REAR PANEL DESCRIPTION
Figure 2
5. Gain Controls
One stepped attenuator per channel increases or decreases the sensitivity of the CP700 2dB per step.
Maximum voltage gain of the CP700 is 32dB.
6. CH1/CH2 Inputs (XLR Connectors)
Two female XLR inputs (one per channel) are provided. These inputs are balanced and configured as
follows: pin 1 ground, pin 2 plus, pin 3 minus. The XLR connections are typically used in portable audio
systems where quick connect and disconnect is warranted.
7. Balanced Barrier Strip Inputs
Balanced inputs are provided on this barrier strip for permanent installation applications. The use of
the appropriate spade type lug is highly recommended for best connection integrity and a neat,
professional appearance.
8. CH1/CH2 Loop Through
Two male XLR (one per channel) are provided for looping the input signals to other CP700s or similar
devices. These connectors are wired in parallel with the female XLR inputs, pin for pin.
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Output Power
400 W / 4 Ohms
350 W / 70.7 V
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PARALLEL BRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
7
9
11
5
8
6
10

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
6
9. Stereo/Parallel/Bridge Switch
This 3 position switch changes the operating mode of the CP700. DO NOT move this switch when the
amplifier is powered up and connected to a load!
• Stereo - When the switch is in this position, the CP700 operates as two independent amplifiers.
Use this position for stereo program material or for two discreet paging/sound masking zones.
• Parallel - When the switch is in this position and a mono input signal is to be used, connect the
input wiring to either channel one OR channel two. The one input signal will drive both amp
channels. Use this position when two speaker zones are being fed by a mono signal.
(See note below)
• Bridge - When the switch is in this position, connect your mono input signal to channel one
ONLY. The speaker load is connected across the two positive terminals as shown in Figure 7 on
page 10. The CP700 will deliver approximately twice the voltage across the load. Please
observe the minimum load specification when operating in Bridge mode.
10. CH1/CH2, Low Impedance Speaker Outputs
The CP700 direct speaker outputs bypass the internal constant voltage transformers and are used
for direct connection to loudspeakers. The CP700 will operate into 2, 4, and 8 Ohm loads. The use of
appropriately sized spade lugs is recommended for speaker wire termination; connect the speaker line
common to the "-" terminal and the positive lead to the "+" terminal.
For high power applications, use the proper gauge wire for the speaker connections. Contact Atlas
Sound Tech Support (1-800-876-3333) for assistance in determining the proper size wire.
11. CH1/CH2, 25/70.7/100V Speaker Outputs
The CP700 will drive constant voltage speaker loads for use in commercial business music/paging
systems and sound masking systems. The use of spade lugs for terminating and connecting the
speaker home runs is recommended. The speaker line common connects to the "0" terminal and the
positive lead connects to whatever voltage your system requires for proper operation.
Calculating Constant Voltage Loads
To calculate the maximum quantity of transformer coupled loudspeakers you can safely connect to the
CP700, first add up the total number of speakers that will be connected to one channel of the CP700,
then multiply that total speaker number by the tap setting you plan to use. The result will be the load
in watts that the amp output channel will see. It is good engineering practice to leave a 20% margin
below the maximum rated output power of the CP700. In this case, one channel of the CP700 can
supply 350W of power at 70.7V, so derate this by 20%, leaving 280W of power available for constant
voltage speakers.
Note: A 6dB loss of output power will occur when operating in parallel mode. To over come this loss,
connect the positive terminal on input 1 to the positive terminal on input 2 and connect the negative
terminal on input 1 to the minus terminal on input 2. Short lengths of 22 gauge wire can be used.

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
7
INPUT WIRING
Balanced Inputs
Balanced input wiring requires two conductors with shield (22 gauge is the most common). The use of
crimp type spade lugs is highly recommended for permanent installations. At the input section located on
the rear of the CP700, wire the "hot"/positive lead to the "+" terminal, the "cold"/negative lead to the "-"
terminal and the shield/drain to the "ground" terminal.
The XLR inputs (+4dB balanced line level) can be utilized with standard 3-pin XLR male to female patch
cables to accommodate outputs from a mixer, equalizer or crossover when the CP700 is used as a
portable sound system amplifier (Figure 3).
Figure 3
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
SIGNAL
CH-2
CH-2
+
THRU
IN
GND
LEVEL
AMPLIFIER INPUTS
CH-1
THRU
IN
+ - -GND
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
Black (-)
Shield
White (+)
Black (-)
Shield
White (+)

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
8
Unbalanced Input
Unbalanced wiring typically is found on consumer equipment (CD players, DVD players, etc.) and is
generally a compromise of noise rejection and cable lengths. A single conductor and an overall shield
are most common, as in the "bargain type" cables supplied with consumer gear. Keep unbalanced wire
lengths within 10 feet between equipment, and wire the hot lead to the "+" terminal, and the shield to the
ground terminal. Do not forget to install a jumper wire between the "-" terminal and the ground, as a loss
of gain will result without this jumper (Figure 4).
Figure 4
Jumper
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
SIGNAL
CH-2
CH-2
+
THRU
IN
GND
LEVEL
AMPLIFIER INPUTS
CH-1
THRU
IN
+ - -GND
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
White/Red (+)
Shield White/Red (+)
Shield

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
9
SPEAKER OUTPUT WIRING
Low Impedance Direct Coupled Output (Stereo)
For direct coupled operation into 2, 4, and 8 Ohm loads, connect the loudspeaker leads to the barrier strip
connections labeled "Direct Output"; connect the hot lead to the "+" terminal and the common lead to
the "-" terminal. The use of heavy gauge wiring is recommended to avoid voltage drops, resulting in
wasted power in the cable. Contact Atlas Sound Tech Support (1-800-876-3333) for suggestions on cable
capacities. Be sure you know the quantity of speakers and cable lengths before calling (Figure 5).
Low Impedance Direct Coupled Output (Parallel Mono)
Observe the speaker connection information in the preceeding paragraph (Stereo Direct Coupled Output).
With the CP700 turned OFF, move the rear mounted selector switch to the "Parallel" position and connect
your mono input wiring to either the channel one or channel two inputs. Both channels will be driven from
this mono signal (Figure 6).
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
To direct coupled
loudspeakers
To direct coupled
loudspeakers
Switch set
to Parallel
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
SIGNAL
CH-2
CH-2
+
THRU
IN
GND
STEREO
PARALLEL BRIDGE
LEVEL
AMPLIFIER INPUTS
CH-1
THRU
IN
+ - -GND
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
White
Black
Shield
Figure 5
Figure 6
Optional Jumpers
See Note on Page 6

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
10
Bridge Mono Configuration (Direct Coupled)
If higher power levels are required, the Atlas CP700 can be used in Bridge Mono mode, which utilizes
both channels of the amp across the speaker load.
With the CP700 turned OFF, move the rear mounted selector switch to the "Bridge" position and connect
the input signal to channel one. Connect your speaker load (4 and 8 Ohm only) across the "+" terminals of
both channels, with channel one being positive (Figure 7).
Caution! A high voltage potential exists across the two "+" speaker terminals when operating in
any Bridge Mode application!
Figure 7
25V, 70.7V, and 100V Transformer Output Wiring
For transformer coupled operation into high impedance loads, connect your loudspeaker leads to the
barrier strip connections labeled "Audio Transformer." Connect the speaker home runs as follows:
• 25V - Connect the positive speaker lead to the terminal labeled "100" and the negative speaker
lead to the terminal labeled "70" (Figure 8).
• 70.7V - Connect the positive speaker lead to the terminal labeled "70" and the negative speaker
lead to the terminal labeled "0" (Figure 9).
• 100V - Connect the positive speaker lead to the terminal labeled "100" and the negative speaker
lead to the terminal labeled "0" (Figure 10).
• Refer to page 6 of this manual to the paragraph entitled "Calculating Constant Voltage Loads" to
determine how many transformer coupled loudspeakers you can drive with the Atlas CP700.
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
To loudspeakers,
4 Ohm minimum
Ensure the Stereo,
Parallel, and Bridge
Switch is set to "Bridge."
STEREO
PARALLEL BRIDGE

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
11
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
To 70.7V speaker load
25V
To 25V speaker load
To 25V speaker load
70.7V
To 70.7V speaker load
Figure 8
Figure 9

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
12
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
100V
To 100V speaker load
To 100V speaker load
Figure 10

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
13
Bridge Mono Transformer Coupled Output Wiring for 140V/200V Output Operation
The CP700 can be configured to drive 140V and 200V speaker lines.
Please observe all necessary safety precautions as the potential for electric shock at the speaker
terminals is present.
With the CP700 turned off, move the rear mounted selector switch to the "Bridge" position and connect
the input signal to channel one. Connect your speaker load across the "+" terminals of both output
terminals as follows:
• 140V Operation - Connect the positive lead of the speaker load to the channel ONE 70V
positive "+" terminal, the negative speaker lead connects to the channel TWO 70V positive "+"
terminal. Connect a suitable jumper wire between the two terminals labeled "0." Consult your
local codes to determine if Class I wiring is required (Figure 11).
• 200V Operation - Connect the positive lead of the speaker load to the channel ONE 100V
positive "+" terminal, the negative speaker lead connects to the channel TWO 100V positive
"+" terminal. Connect a suitable jumper wire between the two terminals labeled "0." Consult
your local codes to determine if Class I wiring is required (Figure 12).
Caution! A high voltage potential exists across the two "+" speaker terminals when operating in
any Bridge Mode application!
Figure 11
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
Note Jumper
To 140V speaker load

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
14
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+ 70 1000
BRIDGE
MONO
-
Figure 12
Note Jumper
To 200V speaker load

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
15
SPECIFICATIONS
DIRECT POWER OUT PROTECTION CIRCUITS
Max Average Power @ 35Hz-20kHz with 0.1% THD
(10-80K Filter)
8 Ohm, 1kHz, 0.1% THD 240W X 2
4 Ohm, 1kHz, 0.1% THD 400W X 2
2 Ohm, 1kHz, 0.1% THD 550W X 2
Bridged Mono 8 Ohm 850W
1kHz, 1% THD
Bridged Mono 4 Ohm 1100W
1kHz, 1% THD
Output Offset Voltage Protection
Heat Sink Overheat Protection
Transformer Overheat Protection
Load Shorting Protection
Power On/Off Protection
Soft Clip Limiters
TRANSFORMER OUTPUTS CONTROLS
25V 280W X 2
70V 350W X 2
100V 350W X 2
140V Bridged 700W
200V Bridged 700W
Power Switch, Ch 1/Ch 2 gain (41 step)
Parallel/Stereo/Bridge Switch
FREQUENCY RESPONSE COOLING
Direct Outputs (+0/-3dB) 30Hz-50kHz
Transformer Outputs (+0/-3dB) 30Hz-16kHz
Dual Speed Fan, Temperature Controlled
THD+N INDICATORS
8 Ohm, 1kHz, 240W per channel <.05% Power, Protect, Signal, Limit
SENSITIVITY DIMENSIONS
Rated Output into 8 Ohms 1.25V 132mm X 480mm X 428mm (5.19" X 18.9" X 16.85")
VOLTAGE GAIN NET WEIGHT
32dB 24.3kg (54 lbs)
INPUT IMPEDANCE SHIPPING WEIGHT
Balanced/Unbalanced 20k/10k Ohm 26kg (57 lbs)
DAMPING FACTOR
8 Ohms Output, 10 Vrms >200dB
S/N RATIO
8 Ohms per Channel @240W >100dB

Specifications are subject to change without notice
AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. • TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
©2005 ATLAS SOUND LP Printed in U.S.A. ATS002102 RevC 9/05 PP
OWNER'S MANUAL
CP700 COMMERCIAL
POWER AMPLIFIER
16
Limited Warranty
All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or
commercial purchaser to be free from defects in material and workmanship and to be in compliance with
our published specifications, if any. This warranty shall extend from the date of purchase for a period
of three years on all Atlas Sound products, including SOUNDOLIER brand, and ATLAS SOUND brand
products except as follows: one year on electronics and control systems; one year on replacement parts;
and one year on Musician Series stands and related accessories. Additionally, fuses and lamps carry no
warranty. Atlas Sound will solely at its discretion, replace at no charge or repair free of charge defective
parts or products when the product has been applied and used in accordance with our published operation
and installation instructions. We will not be responsible for defects caused by improper storage, misuse
(including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres,
water immersion, lightning discharge, or malfunctions when products have been modified or operated in
excess of rated power, altered, serviced or installed in other than a workman like manner. The original
sales invoice should be retained as evidence of purchase under the terms of this warranty. All warranty
returns must comply with our returns policy set forth below. When products returned to Atlas Sound do
not qualify for repair or replacement under our warranty, repairs may be performed at prevailing costs for
material and labor unless there is included with the returned product(s) a written request for an estimate of
repair costs before any nonwarranty work is performed. In the event of replacement or upon completion of
repairs, return shipment will be made with the transportation charges collect.
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF
CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY, ATLAS SOUND SHALL NOT BE LIABLE IN
TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE
ARISING OUT OF THE INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS. THE ABOVE
WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Atlas Sound does not assume, or does it authorize any other person to assume or extend on its behalf,
any other warranty, obligation, or liability. This warranty gives you specific legal rights and you may have
other rights which vary from state to state.
Other manuals for CP700
2
Table of contents
Other Atlas Amplifier manuals

Atlas
Atlas AA240 User manual

Atlas
Atlas MVXA User manual

Atlas
Atlas DPA-102PM User manual

Atlas
Atlas MA40G User manual

Atlas
Atlas TSD-ML22VCA User manual

Atlas
Atlas PA702 User manual

Atlas
Atlas CP700 User manual

Atlas
Atlas AA200PHD-CE User manual

Atlas
Atlas TSD-PA10VG User manual

Atlas
Atlas AA50PHD User manual

Atlas
Atlas AA200PHD User manual

Atlas
Atlas AA120 User manual

Atlas
Atlas TSD-ZDC User manual

Atlas
Atlas STRATEGY AA35 User manual

Atlas
Atlas AA60 User manual

Atlas
Atlas TSD-PA252G User manual

Atlas
Atlas STRATEGY AA35 User manual

Atlas
Atlas DSP8807 User manual

Atlas
Atlas DSP2210 User manual

Atlas
Atlas 100 Series User manual