manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Atomberg
  6. •
  7. Fan
  8. •
  9. Atomberg RENESA SMART + User manual

Atomberg RENESA SMART + User manual

Atomberg Technologies Pvt Ltd
Corporate office:
Rupa Solitaire, Office No. 1205, Millenium Business Park, Mahape, Navi Mumbai 400 710.
Maharashtra, India W: www.atomberg.com
Manufacturing unit
Plot No D-130 B, TTC Industrial Area, Shirawane, Navi Mumbai 400 706.
Ok Google
works with
Google is a trademark of Google LLC.
MAINTENANCE
Periodic cleaning of your ceiling fan is the only maintenance needed.
When cleaning, use only a soft lint-free cloth or a brush to avoid scratching the smooth
paint finish. You can use a moist cloth to remove stains if required. However, do not use
water directly. Abrasive cleaning agents are not required and should be avoided to prevent
damage to the outer finishing.
WARNING
• Do not use water when cleaning your ceiling fan. It could damage the motor by
causing a short-circuit and create the possibility of an electrical shock.
• Do not bend the blades while cleaning. A bend in the blade may result in unstable fixing
and affect air delivery.
CEILING FAN
RENESA SMART +
INSTRUCTION
MANUAL
IMPORTANT NOTE:
Read this manual carefully before installing or operating your
new Atomberg RENESA SMART+ Ceiling Fan. Ensure you save
this manual for future reference.
IOT enabled
Works with App
Problem Cause Solution
Restart/speed Regulator is not bypassed Make sure the regulator is
variation eliminated from the connection
Blades have wrong sweep Check the sweep of the blades
with the fan sweep before
assembling
INSTALLATION
Assembly:
Mandatory Step:
Bypass or eliminate the regulator from the
connection before installing an Atomberg
fan for optimal performance
The picture shown above depicts the exact order of placement of various parts.
Dear Customer,
Congratulations on purchasing ATOMBERG'S super-efficient RENESA SMART+ ceiling fan.
Please read this guide before using this product. It would also be advisable to store this
guide safely for future reference.
WARNING
PACKAGE CONTENTS
MOTOR 3 ALUMINIUM
BLADES
DOWN
ROD
SHACKLE
KIT
MANUAL
2
CANOPIES WARRANTY
CARD
REMOTE
Shackle kit
Top canopy
Down rod
Bottom canopy
Blade
Shaft with motor
FEATURES
India's most energy-efficient RENESA SMART+ ceiling fan • More than 65% energy saving
as compared to an ordinary fan • Highest service value (air delivery/power consumed)
in India • Runs 3 times longer on inverter resulting in longer battery runtime • Smart
sensorless algorithm for greater reliability • No heating of fan even after long hours of
runtime, resulting in an extra-long life • Consistent speed even at low voltages • Easy
speed controls using a smart remote • LED indications for easy remote use • TIMER
mode automatically switches off the fan • SLEEP mode reduces the fan speed after a
preset duration and saves energy • Full copper motor and double ball-bearing for
better stability and longer life • Aluminum body and blade, resulting in zero rust •
Zinc-plated parts and accessories for a rust-free life • Protective coating over
electronics for better resistance against moisture • All fans are tested for durability
under extreme conditions before shipping.
BIG ENERGY SAVINGS
Atomberg is India's most energy-efficient ceiling fan. A super-efficient BLDC motor
technology is used, which consumes very little energy. Atomberg fans consumes just
1/3rd of the power used by ordinary induction fans. Ordinary induction fans run on
75watts, whereas Atomberg fans run on just 28watt at full speed.
There is huge saving potential for households, and institutions such as hospitals,
colleges, schools and commercial spaces.
SAFETY INSTRUCTIONS
• Be careful of the fan and blades while cleaning, painting, or working near the fan.
Always turn off the power to the ceiling fan before servicing.
• Do not put your hand or any other objects near the fan blades while the fan is running.
• Do not modify the blade design to change the air flow.
• Do not install or use this fan if any part is damaged or missing.
• This product is designed to be used only with the parts or accessories supplied with this
product and/or any accessories designed specially for use with this product by Atomberg.
Any such use of other parts or accessories may turn the product warranty null and void, and
may result in personal injury or property damage as well.
WARNING
• Observe the following to reduce the risk of fire, electric shock or injury: Only use this unit
in the manner intended by Atomberg. If you have any questions regarding the product,
please contact Atomberg.
• Before servicing or cleaning, switch off the main power panel and switch.
• Wiring of the fan must be done only by a qualified and certified electrician.
Step 1.
Carefully remove the motor from the box and keep it
on soft padding to prevent it from getting scratched. Motor
Ceiling
Hook
Step 2.
Insert the canopy into the shaft and securely attach
the shackle to the hanger or ceiling hook using the
screws provided with the package. Fasten the nut,
and make sure that you fit the safety nut, washer
and the R-pin to prevent slipping. Adjust the top
canopy so that it covers both the assembly and the
connection.
Step 3.
Align the holes on the blade shank with the motor
holes. Securely fasten the blades with the screws
and washer provided.
HOW TO HANG THE FAN
Step 4.
Insert the screw to assemble the
shaft and the down rod. Insert
the washer, nut and R-Pin in the
sequence depicted in the illustration
below. Pull down the canopy to
cover the PCB
box.
Spring
washer
R pin
Nut
Hex
screw
Down rod
Canopy
WARNING
• If the blades are not secured properly with the screws and the washer, it may cause injury
during operation. Also, an imbalanced fan may cause damage to the motor and reduce the
lifetime of the fan.
• Any damage caused by incorrect installation and wrong practices followed while connecting
the fan are not covered under the warranty terms. Please check the warranty terms in detail.
• Do not turn on the fan until the blades are securely fastened to the ceiling fan.
Step 6.
Step 5.
Ceiling
At least 7 feet
At least 1 foot
Floor
USING YOUR CEILING FAN
Congratulations! You have successfully installed your new ceiling fan using the instructions
provided in this guide.
1 Restore the electrical power.
2 Power 'ON' the ceiling fan using the switch on the panel in the room. The LED indicator
flashes ‘ON’ when power supply is restored.
WARNING
• The fan blade must be hung with at least 1 foot of
clearance from the ceiling for optimal performance and
safety.
• Any object next to the fan must be at least 2 feet away
from the tip of the fan blade to reduce chances of
risk or injury.
• The fan must be hung with at least 7 feet of clearance
from the floor to the blades.
HOW TO USE YOUR REMOTE
Longlasting AAA batteries are used in the remote
The remote provided along with
your
ceiling fan is ergonomically
designed.
The soft controls on the remote are
longlasting.
SPEED
CONTROL
BOOST
MODE
TIMER
MODE
SLEEP
MODE
LED
CONTROL
ON/OFF
CONTROL
WARNING
DO NOT use the fan regulator as
the fan is operated using a remote.
Eliminate the regulator by using a
direct connection from the switch
to the fan.
SLEEP mode adds smart comfort, as
the temperature drops over the night
and if you wish to auto-reduce the
speed.
With TIMER mode, you can switch
off the fan automatically after set
hours to further save energy.
WARNING
• Any connection to wires must be securely sealed using electrical insulation tape to prevent
electric shocks or fire hazard.
• Avoid pinching of wires between the shackle kit, down rod and ceiling hook assembly to
prevent electric shocks or fire hazard.
3 Use your remote to operate the ceiling fan.
4 If you are leaving the room or facility for a long duration or a holiday, then power 'OFF'
the ceiling fan using the switch on the panel.
WARNING
The performance of the fan gets affected if the regulator is not bypassed, and may lead to
speed variations, restarting or low speed. Eliminate regulators by using a direct connection
from the switch to the fan.
ELECTRICAL WIRING INSTRUCTIONS
Make the correct wire connections to operationalise the
fan. Adjust the canopy as required.
Color codes of the wires may vary from region to region.
Please check your state or country notifications regarding
the same.
Not recommended for use in high humid areas like washroom,
direct or indirect exposure to water entries etc.
TROUBLESHOOTING
Your ceiling fan is designed to be longlasting with a strong body and well-tested
electronics. However if any problem arises, please refer to the guidelines shared. Please
contact a local electrician or service engineer if you need any help.
Problem Cause Solution
Fan does Fuse down / MCB shut off Check fuse of the MCB on the mains.
not start
Loose wire connection to Check the wire connection
fan or to the switch on the and restore the connection
panel
Fan still does not start Please contact the service
number provided.
Regulator is connected to It is recommended that the
the fan regulator should not be
connected to this ceiling fan and
it is instead controlled using
the remote provided with it.
Fan making Bearing inside the housing This ceiling fan is designed to
noises has problems be longlasting. However, after
many years of use, the
bearing may wear off and may
need to be replaced.
Fan blades are not seated Make sure the blades are
properly on the motor properly fastened to the body.
Loose connection may cause
accidents.
Shackle kit rattling Make sure that the screws and
nuts are securely fastened
along with washer provided.
Fan is wobbling Nut holding motor shaft Securely fasten the nut and
and the down rod is loose bolts along with washers as
per the instructions provided
in this manual.
Nut holding down rod and Securely fasten the nut and
shackle kit is loose bolts along with washers as
per the instructions provided
in this manual.
Screws in the shackle kit and Securely fasten the nut and
the ceiling hook are loose bolts along with washers as
per the instructions provided
in this manual.
Fan blades are not seated A common mistake is fixing the
properly on the motor blades in the reverse direction.
Please set it right, and
securely fasten the screws.
Fan blades are out of balance Make sure that the blades are
not bent during cleaning. Also,
interchanging them helps
balance the blades.
CONTROLLING THE FAN’S SPEED WITHOUT THE REMOTE
Renesa Smart+ is a loT enabled smart fan that works with Amazon Alexa App/Echo and Google Home
App/Assistant it can also be controlled by Atomberg Application.The fan's main switch can be used to control
its speed. Turn the fan's switch OFF and ON repeatedly to set the fan to the desired speed. Delay between
toggling between the OFF and ON buttons should be approximately 1 second. If toggling is too fast or too
slow, it will not work. While toggling, the LEDs will glow to indicate the speed of the fan. Refer to the below
table to control the fan using the switch.
Remote key Function Description LED status
1 Speed 1 Sets fan to speed 1 One LED will glow for 1 sec
2 Speed 2 Sets fan to speed 2 Two LED will glow for 1 sec
3 Speed 3 Sets fan to speed 3 Three LED will glow for 1 sec
4 Speed 4 Sets fan to speed 4 Four LED will glow for 1 sec
5 Speed 5 Sets fan to speed 5 Five LED will glow for 1 sec
B Boost Speed Sets Fan to boost Mode All LEDs blink thrice
Timer OFF Timer/ •Fan automatically Timer 1-One LED blinks twice
Wakeup switches OFF/ON after the Timer 2-Two LEDs blink twice.
Timer set hours (1,2,3 & 6 Hrs). Timer 3-Three LEDs blink twice.
•No. of LEDs suggest no. of hrs set Timer 6-All LEDs blink twice.
•Press the Timer key 5 times, Timer disable - Odd and Even
to disable Timer or once LEDs blink in a pattern thrice.
after 6 Hr timer indication.
Sleep Reduce •Sleep mode works for Sleep Mode Enable - Four LEDs
speed of 4 Hours. Speed is reduced in square blink twice.
fan by 1 by 1 every 2 hours. Afterwards, the Sleep Disable - Odd and Even
every 2 fan continues to run on a reduced LEDs blink in a pattern thrice.
hours for constant speed. Fan speed will not
4 hours reduce below speed 1.
•If sleep mode is already set and sleep
key is pressed, it will disable sleep mode.
LED LED ON/OFF Turn ON/OFF LEDs. All six LEDs will glow.
Note: Sleep mode will not work if the fan is OFF.
1 time Previous Fan runs at the No indication
speed same speed
2 times Speed 1 Lowest speed 1 1 LED will glow and turn off
after 1 second.
3 times Speed 2 Speed 2 2 LEDs will glow and turn off
after 1 second.
4 times Speed 3 Medium speed 3 3 LEDs will glow and turn off
after 1 second.
5 times Speed 4 Speed 4 4 LEDs will glow and turn off
after 1 second.
6 times Speed 5 High speed 5 5 LEDs will glow and turn off
after 1 second.
7 times Boost Boost mode speed 6 LEDs will glow and turn off
after 1 second.
Toggle
(Turn switch
OFF and ON)
LED statusDescriptionsSpeed

Other Atomberg Fan manuals

Atomberg RENESA User manual

Atomberg

Atomberg RENESA User manual

Atomberg Ozeo User manual

Atomberg

Atomberg Ozeo User manual

Popular Fan manuals by other brands

impress IM-712W Use and care book

impress

impress IM-712W Use and care book

Monte Carlo Fan Company 5BCTR20 Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5BCTR20 Series Owner's guide and installation manual

Pro-Elec PEL01915 instructions

Pro-Elec

Pro-Elec PEL01915 instructions

Warehouse DL03P02 Use and care guide

Warehouse

Warehouse DL03P02 Use and care guide

QuFresh SL100-3 instructions

QuFresh

QuFresh SL100-3 instructions

ARDES AR5T85R Instructions for use

ARDES

ARDES AR5T85R Instructions for use

Titon TP461BC manual

Titon

Titon TP461BC manual

Westinghouse 72076 manual

Westinghouse

Westinghouse 72076 manual

Sortimo GA 00005 Instructions for use

Sortimo

Sortimo GA 00005 Instructions for use

Levante LEV9MDF Operation manual

Levante

Levante LEV9MDF Operation manual

Airius 45/EC installation guide

Airius

Airius 45/EC installation guide

Hunter 28488 Parts guide

Hunter

Hunter 28488 Parts guide

Miele DFKS Operating and installation instructions

Miele

Miele DFKS Operating and installation instructions

EFBE-SCHOTT VT 801 manual

EFBE-SCHOTT

EFBE-SCHOTT VT 801 manual

Hinkley 52 TREY instruction manual

Hinkley

Hinkley 52 TREY instruction manual

Ventamatic CXSOLGB installation instructions

Ventamatic

Ventamatic CXSOLGB installation instructions

LUCCI Airfusion Aria Installation instructions manual

LUCCI

LUCCI Airfusion Aria Installation instructions manual

Craftmade Union installation guide

Craftmade

Craftmade Union installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.