AutomationDirect ATLAS ATM1500 User manual

1
www.automationdirect.com
1 - 8 0 0 - 6 3 3 - 0 4 0 5
AT AS INDUST IAL FLAT PANEL PC MONITO
QUICK INSTALLATION GUIDE
3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860, USA
TM
1. Verify Contents of the Box:
• Atlas Flat Panel Monitor – (A “T” at the en of the part number
esignates the touch screen option.)
• VGA vi eo cable – 10’ length
• RS-232 Serial touch screen cable (touch screen mo els only) – 10’ length
• USB touch screen cable (touch screen mo els only) – 10’ length
• Mounting clips an screws (qty of 14)
• USB retention bracket an mounting screw (touch screen mo els only)
• Optional power plug protective cover
• Documentation an Driver CD
• This Quick Installation Gui e
Description:
The Atlas monitor is a high performance color TFT flat panel monitor
specifically designed for harsh industrial environments including Class
I Division 2, Class II Division 2 and Class III Hazardous Locations. The
Atlas monitor accepts standard analog VGA input or digital DVI input,
and can display all VESA video modes up to 1280 x 1024 at 75 Hz with
16 million colors. An optional 5-wire analog touch screen is available
that offers both RS-232 and USB interface capability. The monitor is
housed in a heavy duty steel chassis with a powder coated machined
aluminum bezel. The monitor is certified to NEMA 4/4X/12 standards,
is UL/CUL listed, meets CE requirements and is RoHS compliant.
Panel mounting is simplified using convenient mounting clips instead
of conventional studs. All monitors are shipped with a power input
wiring receptacle, 10’ VGA cable, 10’ RS-232 cable (touch panel
models only), 10’ USB Cable (touch panel models only), mounting
hardware, this uick Installation Guide, and CD-ROM containing
Hardware User’s Guide (ATM-USER) and touch screen driver
software for Windows® operating systems.
NOTE:SEE THE HARDWARE USER’SGUIDE, ATM-USER,
INC UDED ON THE SUPP IED DOCUMENTATION & DRIVER CD FOR
ADDITIONA DETAI S. THE USER’SGUIDE IS IN PDF FI E FORMAT AND
REQUIRES DOWN OADING ADOBE’S FREE ACROBAT READER TO OPEN
AND VIEW.
Atlas Industrial Monitor
Contents:
3
12
B
F
C
A
E
D
Dimensions:
Agency Approvals:
Mounting Clips
(qty. 14)
VGA Video
C ble
Atlas
Monitor
P ck ging
M teri l
Document tion
& Driver CD
RS-232 C ble
& hex sp cers
(“T” ver. only) USB C ble
(“T” ver. only)
Certific tions & St nd rds
Name UL508 ANSI/ISA
12.12.01-2012 CE
Atlas
Flat Panel Monitor E157382 E200031
EN 55022-1: Class A,
EN 61000-3-2: Class A,
EN 61000-3-3,
EN 61000-6-2,
IEC 60950-1
UL
CUS
R
Mode A B C D E F
ATM1500/ATM1500T 12.80”
(325.1 mm)
15.80”
(401.3 mm)
2.65”
(67.3 mm)
3.95”
(100.3 mm)
1.17”
(29.8 mm)
2.40”
(61.0 mm)
ATM1700/ATM1700T 14.48”
(367.8 mm)
17.14”
(435.4 mm)
2.85”
(72.4 mm)
5.00”
(127 mm)
1.32”
(33.5 mm)
2.60”
(66.0 mm)
ATM1900/ATM1900T 15.70”
(398.8 mm)
18.66”
(474.0 mm)
2.95”
(74.9 mm)
6.00”
(152.4 mm)
1.50”
(38.1 mm)
2.70”
(68.6 mm)
Quick
Inst ll tion
Guide

2
www.automationdirect.com
1 - 8 0 0 - 6 3 3 - 0 4 0 5
WARNING: Damage can occur by applying excessive torque to the
mounting clips.
2. Install Monitor through Enclosure Door or Wall
• The monitor must be installe on a flat surface of a NEMA type 1, 4, 4X
or 12 enclosure.
• Use imensions as shown in the iagram below to provi e a
rectangular mounting cutout in an approve NEMA 4/12 enclosure’s
oor or wall.
• Mount the monitor through the enclosure cutout, install an tighten (14)
mounting clips to a torque of 8.0 inch-poun s as shown in the iagram
to the right.
CUTOUT
A
B
Cutout Dimensions:
CUT AWAY
VIEW
MAXIMUM ALLOWABLE
PANEL THICKNESS
Mounting Clip Installation:
Warning: Suitable for use in Class 1, Division 2 Groups A, B, C,
and D; Class 2 Division 2 Groups F and G, Class III hazardous
locations, or nonhazardous locations only.
3. Connect DVI or VGA Video Cable between Monitor & PC
• Connect the inclu e 10’ VGA vi eo cable from the vi eo connector on
the monitor to the vi eo output connector on the host PC being use
with the monitor or use a igital DVI cable (sol separately).
• If using a DVI cable, input selection must be change to DVI by pushing
the UP button on the rear of the monitor.
4. Connect USB or Serial Cable between Monitor & PC
• Applies to touch screen version only.
• Use either the inclu e 10’ RS-232 Serial touch screen cable or the 10’
USB touch screen cable from the appropriate connector on the monitor
to the appropriate connector on the host computer; o not connect
both.
• If using the USB cable, secure the cable using the inclu e USB
retention bracket an screw; consult the Har ware User’s Gui e,
ATM-USER, on the supplie Documentation an Driver CD for etails.
*NOTE: USE ONE OR THE
OTHER, NOT BOTH.
TOUCH SCREEN
CABLES *
VIDEO CABLE *
DISPLAYPOWER
WARNING
Touch Screen is still
active while display
power is off
Cable Connections:
NOTE:THE 17” AND 19” MONITORS WI PRODUCE THE BEST IMAGE
QUA ITY IF THE PC IS SET FOR A 1280 X1024 PIXE S @ EITHER 60,
OR 75 HZ. VIDEO MODE.
Mode A B
ATM1500/ATM1500T 12.00”
(304.8 mm)
15.00”
(381.0 mm)
ATM1700/ATM1700T 13.70”
(348.0 mm)
16.35”
(415.3 mm)
ATM1900/ATM1900T 14.90”
(378.5 mm)
17.75”
(450.9 mm)
NOTE:THE 15” MONITOR WI PRODUCE THE BEST IMAGE QUA ITY IF
THE PC IS SET FOR A 1024 X768 PIXE S @ EITHER 60, 70 OR 75 HZ.
VIDEO MODE.
NOTE:WHEN USING THE USB TOUCHSCREEN CONNECTION, THE USE
OF THE USB RETENTION BRACKET IS REQUIRED FOR HAZARDOUS OCA-
TIONS AND HIGH Y RECOMMENDED FOR NONHAZARDOUS OCATIONS.
WARNING - EXPLOSION HAZARD - Do not connect or disconnect the
USB ports unless the power has been switched off or the area is
known to be non-hazardous.
AVER ISSEMEN - RISQUE D'EXPLOSION - Ne pas brancher ou débrancher
le ports USB á moins que l'alimentation á été coupée ou si la zone
n'est pas hazardeuse.
ADVER ENCIA - PELIGRO DE EXPLOSIÓN - No conecte o desconecte los
puertos USB a menos que la computadora se encuentre apagada o
el área se considere no peligrosa.
WARNUNG - EXPLOSIONSGEFAHR - USB-Ports nur anschließen oder
trennen, wenn keine spannung anliegt oder der Bereich nicht
explosiongefährdet ist.
NOTE:TOPREVENT INADVERTANT DISCONNECTION OF VIDEO AND / OR
SERIA TOUCHSCREEN CAB ES ASSURE THAT THE THUMBSCREWS ARE
SUFFICIENT Y TIGHT.
WARNING: An operating temperature of 0 to 50 °C (32 to 122 °F)
ambient termperature inside the enclosure needs to be maintained
for proper operation of the monitor.

3
www.automationdirect.com
1 - 8 0 0 - 6 3 3 - 0 4 0 5
6. Apply Power to the Monitor & PC
• Press the DISPLAY POWER button on the rear of the monitor to wake the
monitor up. Pressing the DISPLAY POWER button again turns off the
backlight inverter an puts the monitor in a re uce power state but
the touch screen remains active. It is important to note that this switch
oes not isconnect power from the monitor. Power is always supplie
to the internal AC/DC power supply, which in turn continually supplies
power to the internal monitor electronics an the optional touch screen
controller.
7. Install the Appropriate Touch Screen Driver
• The calibration of the touch screen occurs by a calibration utility that
installs as part of the touch screen river installation process.
• Applies to touch screen version only.
• Insert the Documentation an Driver CD into the host PC’s CD rive.
• If the CD oes not start automatically with the win ow shown below
isplaye , then go to Start > Run, browse to the CD’s “atlas.exe” file,
open it, an click OK.
• From the Atlas screen, the user can view the Har ware User’s Gui e for
the monitor being use , an /or install the touch screen rivers for the
particular PC operating system being use . Before installing the rivers,
please rea the Touch Screen Driver Documentation for operating
system etails.
• Reboot the PC an restart the monitor to activate the river.
• For the latest rivers go to:
http://support.automation irect.com/pro ucts/atlas.html
8. Verify Video and Touch Screen Functionality
• Verify the monitor’s vi eo isplay by running a familiar program.
• If using the touch screen mo el, use the touch screen to navigate by
running a familiar program.
Display Power
Button
Power
Indicator
DISPLAY POWER
WARNING
Touch Screen is still
active while display
power is off
LCD Power Button:
MAIN MENU
BRIGHTNESS/CONTRAST
1280X1024 63.9KHZ/60HZ
COLOR
POSITION
SETUP
EXIT
R G B
OSD Settings Main Menu:
9. Adjust the Monitor OSD Settings as equired
• Press the Select (Auto A j) control button on the rear of the panel to
initiate an automatic configuration of the screen.
• Although normally not nee e , the control buttons on the rear of panel
can be use to make other a justments to the screen.
• Consult the Har ware User’s Gui e, ATM-USER, on the supplie
Documentation an Driver CD for etaile usage of the OSD settings.
10. Installation Complete
WARNING: he monitor does not automatically select a video input
mode. he user must press the “UP (VGA/DVI)” button on the rear
of the monitor to select either VGA or DVI input. If a “No Video”
message appears on the screen, it is also suggested the user try using
the “UP (VGA/DVI)” button to select the active video input.
NOTE:ONCE YOU HAVE CONNECTED YOUR PC AND THE MONITOR,
SE ECTED THE VIDEO SOURCE, AND POWERED BOTH UNITS, IT IS
SUGGESTED THAT THE “SE ECT (AUTO ADJ)” BUTTON ON THE REAR
OF THE MONITOR BE PRESSED TO MAXIMIZE THE VIDEO SETTINGS.
5. Connect Power to the Monitor
• Power source nee s to be 100 - 240 VAC, 50/60 Hz.
• See power connection iagram to the right.
• Secure plug retention screws to monitor.
• Power shoul not be applie until all cables are attache an the
monitor is rea y to operate.
TOP VIEW
FRONT VIEW
ADC P.N. ATM-AC-CON or
PHOENIX CONTACT P.N. 1777992
LN
Plug Retention Screws
Power
Connection
Label
PE
WARNING: Damage can occur if power is not properly connected.
Power Connections:
100 VAC - 240 VAC INPUT (1.0 Amps Min)
31 2
PIN N . Definiti n
1 AC Line Input
2 AC Neutral Return
3 Protective Earth Ground
P nel Power Dr w
ATM1500 (T) 25 W
ATM1700 (T) 30 W
ATM1900 (T) 35 W
WARNING - EXPLOSION HAZARD - Do not disconnect equipment while
the circuit is live unless the area is known to be free of ignitable
concentrations.
Warning - Explosion Hazard - Substition of any components may
impair suitability for Class 1, Division 2.
Required Wire Specific tion
Wire Size 18 - 12 AWG (0.8 - 3.3 mm2)
Wire Material and
Temperature 60 °C or 60 / 75 °C Copper
Tightening T rque 7.0 lb·in (0.79 Nm)
WARNING – ouch screen is still active while display power is off.
A EN ION – L'écran tactile est toujours actif, méme quand l'af-
ficheur n'est pas alimenté.
ADVER ENCIA – La pantalla táctil sigue activa aún cuando el dis-
play esté apagado.
WARNUNG – ouch screen ist immer noch aktiv, während die
anzeigefläche ausgeschaltet ist.

4
www.automationdirect.com
1 - 8 0 0 - 6 3 3 - 0 4 0 5
Copyright 2007-2018, Automationdirect.com Incorpor ted/All Rights Reserved Worldwide
Accessories & eplacement Parts:
P rt Number Description
ATM-CBL-VGA10 10 ft. 15-pin coaxial VGA cable. Connects any Atlas monitor to a standard VGA card.
ATM-CBL-VGA25 25 ft. 15-pin coaxial VGA cable. Connects any Atlas monitor to a standard VGA card.
ATM-CBL-VGA50 50 ft. 15-pin coaxial VGA cable. Connects any Atlas monitor to a standard VGA card.
ATM-CBL-DV2M 6 ft. (2 meter) DVI (type D) video cable. Connects ATM1700 and ATM1900 to a standard DVI-D
port. DVI cables provide a higher bandwidth video interface than the VGA cables.
ATM-CBL-DV3M 10 ft. (3 meter) DVI (type D) video cable. Connects ATM1700 and ATM1900 to a standard DVI-D
port. DVI cables provide a higher bandwidth video interface than the VGA cables.
ATM-CBL-10 10 ft. serial communication cable. Connects Atlas monitor to std. 9-pin R -232 port.
(touch screen models only)
ATM-CBL-25 25 ft. serial communication cable. Connects Atlas monitor to std. 9-pin R -232 port.
(touch screen models only)
ATM-CBL-50 50 ft. serial communication cable. Connects Atlas monitor to std. 9-pin R -232 port.
(touch screen models only)
USB-CBL-AB3 3-ft (0.9 meter) tandard U B 2.0 cable with tandard-A plug to tandard-B plug. uitable for all
U B devices. (touch screen models only)
USB-CBL-AB6 6-ft (1.8 meter) tandard U B 2.0 cable with tandard-A plug to tandard-B plug. uitable for all
UB devices. (touch screen models only)
USB-CBL-AB10 10-ft (3 meter) tandard U B 2.0 cable with tandard-A plug to tandard-B plug. uitable for all
U B devices. (touch screen models only)
USB-CBL-AB15 15-ft (4.6 meter) tandard U B 2.0 cable with tandard-A plug to tandard-B plug. uitable for all
U B devices. (touch screen models only)
ATM-AC-CON Replacement Power Wiring Connector for AC Powered Units.
ATM-CLIP Replacement flat panel mounting clip kit. Package of 16 clips and screws.
ATM-CBL-VGA10 ATM-CBL-VGA25
ATM-CBL-VGA50 ATM-CBL-DV2M
ATM-CBL-DV3M
ATM-CBL-10 ATM-CBL-25
ATM-CBL-50 USB-CBL-AB3
USB-CBL-AB6 USB-CBL-AB10
USB-CBL-AB15 ATM-AC-CON
ATM-CLIP
WA NING
To minimize the risk of potential safety problems, you should
follow all applicable local and national codes that regulate the
installation and operation of your equipment. These codes vary from
area to area and it is your responsibility to determine which codes
should be followed, and to verify that the equipment, installation, and
operation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result from the failure
to follow all applicable codes and standards. We do not guarantee the prod-
ucts described in this publication are suitable for your particular applica-
tion, nor do we assume any responsibility for your product design,
installation, or operation.
If you have any questions concerning the installation or operation of
this equipment, or if you need additional information, please call
Technical Support at 770-844-4200.
This publication is based on information that was available at the time
it was printed. At Automationdirect.com®we constantly strive to
improve our products and services, so we reserve the right to make
changes to the products and/or publications at any time without notice
and without obligation. This publication may also discuss features that
may not be available in certain revisions of the product.
Additional Help and Support
• For pro uct support, specifications, installation, an
troubleshooting, a Har ware User’s Gui e, ATM-
USER, is inclu e on the supplie Documentation
an Driver CD, or ownloa able from the Online
Documentation area of the AutomationDirect Web site.
• For a itional technical support an questions, call our Technical
Support team @ 770-844-4200.