AXE 5 Digit DISPLAY(48x96mm)
MMX-RS series
■Features
◎
Readout Range from -19999~99999
◎
Modified inside parameter, must have pass code
◎
RS485 Communication interface, Protocol MODBUS RTU
MODE
◎
EEPROM Saving, data safekeeping about 10 years
◎
BAUD RATE:19200/9600/4800/2400
◎
Decimal point can be modified
■
Name of Parts
Key Introduce Operation Manual
Key Function
1. In normal display, The key function is call out setting group
2. In parameter setting page, The key function is data Enter , and go to next page
Key Function
1.
Into parameter setting page, the parameter mark & data is alternate display, If need modify data
can press shift key into setting procedure, The dis
play is lock parameter data, this time must let off
key about 0.2 sec, press again, the cursor(twinkle express)is cycle moving left. (Key Response
about 0.2 sec)
Key Function
1. Into parameter setting page, the parameter mark & data is alternate display,
can press shift key into setting procedure, The display is lock parameter data, this time must let off
key about 0.2 sec, press again, the cursor(twinkle express)is cycle moving right. (Key Response
about 0.2 sec)
Key Function
1. Int
o parameter setting page, the parameter mark & data is alternate display, If need modify data
can press up key into setting procedure, The display is lock parameter data, this time must let off
key about 0.2 sec, press again, the parameter data will increment. (Key Response about 0.2 sec)
Key Function
1.
Into parameter setting page, the parameter mark & data is alternate display, If need modify data
can press down key into setting procedure, The display is lock parameter data, this time must let
off key about 0.2 sec, press again the parameter data will decrement. (Key Response about 0.2 sec)
& Key Function
In setting group or setting page press & key return normal display, but if in setting page the
modify data will be lost
No Key in anything In setting group or setting page no key in anything about 2 minutes, return normal display
Step
Parameter mark
description
Parameter mark
Operation manual
1
Normal display
Press /FUNC key into P.COD setting page
1-2
P.COD(Pass code input
page)
Default=0
1. Key in 6 digit pass code with & & key
2.Press key, the pass code is right into setting group , otherwise
return normal display
1-3
DP1(Decimal Point
setting page)
Default=0
1.Decide decimal point position with
& key (0 to 4)
2.Press key enter data and into DP2
setting page
Set-value right
Parameter Enter
Set-value left
Communication indicate
DIO
Display 1
Display 2