Axis STAV20 User manual

Vertical automatic stand
STAV
User Manual
File: 2019-01-31 STAV GB

2USER MANUAL
_____________________________________________________________________________________________________________________
Index:
1. Introduction....................................................................................................................................... 3
2. Complete set .................................................................................................................................... 3
3. Technical data.................................................................................................................................. 3
4. Stand’s keyboard.............................................................................................................................. 4
5. Safety rules ...................................................................................................................................... 5
6. Disposal rules................................................................................................................................... 5
7. Preparing to work ............................................................................................................................. 6
8. General operation rules.................................................................................................................... 7
9. Communication interface.................................................................................................................. 8
10. Dimensions....................................................................................................................................... 9
11. Applications menu .......................................................................................................................... 10
11.1 Advanced mode ............................................................................................................. 10
11.2 Manual, Peak, Cycle and Step mode............................................................................. 12
12. Main menu...................................................................................................................................... 12
12.1 Home position ........................................................................................................... 12
12.2 Force gauge .............................................................................................................. 13
12.3 Applications .............................................................................................................. 13
12.4 Configuration............................................................................................................ 13
Communicates ............................................................................................................................................ 14

USER MANUAL 3
_____________________________________________________________________________________________________________________
1. Introduction
STAV500 vertical test stand with electric drive is designed for FB50, FB200,
FB500, FC50, FC200 and FC500 force gauges. Thanks to precise programming
motion mechanism STAV500 enables to perform precise measurements during e.g.
material resistance testing.
2. Complete set
Basic set consists:
1. Automatic stand
2. Mounting element (force meter mounting)
3. Power supply
3. Technical data
Type
Automatic stand STAV
Maximal tested force (max)
500N
Stroke (travel)
300mm
Maximal speed
300mm/min
Rigidity*
1,3mm
Travel accuracy
+/- 0,2mm
Travel resolution
0,01mm
Working temperaturę
0÷+40°C
Interfaces
RS232C, USB
Power supply
-230V 50Hz 100VA / 24V 4 A
Weight
22,5kg
*Maximal difference in distance at maximum applied force and at lack of force
(measured between force meter tip and stand’s pin)

4USER MANUAL
_____________________________________________________________________________________________________________________
4. Stand’s keyboard
turn on / off the stand,
start/stop movement,
- opening applications (functions) menu,
- back,
- during inscribing data used for deleting or used for returning to
previous position (inscribing PIN code),
- opening main menu,
- enter (choosing option),
- during inscribing data adds another position or used for moving
to next position (inscribing PIN code),
STOP safety button that disconnects motor’s supply,
Knob enables to move cursor up or down (moving the knob right or left) and
choosing selected option (by pressing the knob).
Knob

USER MANUAL 5
_____________________________________________________________________________________________________________________
5. Safety rules
It is necessary to follow the safety rules. Obeying this
rules is crucial to avoid electrical shock, damaging the
stand or other connected devices.
Repairs and necessary regulations can be done by authorized personnel
only
To avoid fire risk use a feeder of an appropriate type (supplied with stand)
and supply voltage must be compatible with specified technical data.
Do not use the stand if the cover is open.
Do not use the stand in explosive conditions.
Do not use the stand in high humidity environment.
If the stand does not seem to operate properly, turn it off and don’t use it
until checked by authorized service centre.
During measurements keep safe distance from the moving elements
and the sample.
6. Disposal rules
According to current acts of low about protection of
natural environment, wasted balances should not be put
into waste containers together with ordinary waste.
Wasted stand after operation period can be delivered to units authorised
for gathering wasted electronic devices or to the place where it was
bought.

6USER MANUAL
_____________________________________________________________________________________________________________________
7. Preparing to work
The stand must be used in room where the following requirements must be
fulfilled: temperature must be between 0 to 40°C, air humidity 20% ÷80%.
Preparing device to work:
1. Put the stand on flat stable surface.
2. Carefully mount a force meter to the stand by using supplied mounting
element.
3. Connect supply to stand.
4. Connect force meter to supply (if user doesn’t use internal accumulators).
5. Turn on the force meter (press ON/OFF) and the stand (press I/Q ).
6. The stand is ready to work.
Stand must be set in room in such way as to allow easy access
to safety button STOP !

USER MANUAL 7
_____________________________________________________________________________________________________________________
8. General operation rules
1. Make every effort to put the sample safetly and stable before starting
measurements.
2. During work keep hands in safe distance from sample and moving parts.
During work keep hands in safe distance from sample and
moving parts!
In case of any danger of losing health immediately press safety
button STOP located on the device’s front!

8USER MANUAL
_____________________________________________________________________________________________________________________
9. Communication interface
The stand is equipped with interfaces: RS232C and USB.
RS232C is used to connect the stand to force meter in order to receive actual force
value from the force meter. Wireless communication is also possible if force meter
is equipped with wireless module.
USB is used to connect computer with stand in order to send measurements to
computer.

USER MANUAL 9
_____________________________________________________________________________________________________________________
10. Dimensions

10 USER MANUAL
_____________________________________________________________________________________________________________________
11. Applications menu
After pressing key applications/functions menu shows up:
The applications menu enable to select working mode that fits user’s needs.
11.1 Advanced mode
Advanced mode is multifunctional mode. After selecting Advanced user can select
from the list proper motion program. After selecting motion program user can
either Edit or Load.
Edit is used for setting the motion program.
Load is used for loading previously set motion program.
After selecting Edit user can choose from:
- ID –inscribing motion program name,
- Steps –inscribing number (max 8) of
steps (actions that are included in one
cycle),
- Ref. Pos. Set –setting position from
which the movement will start,
- Ref. Pos. –value of actual reference
position,
- Cycles –inscribing number of cycles
(how many times the movement will be
repeated) 1 ÷ 9999,
- Auto Return –returning to reference
position,
- Break Stop –automatic detecting that the
sample breaks and stopping the
measurement.
Depending on number of Steps that user will inscribe number of positions on list
will increase. Each step will add positions to the list.
APPLICATIONS s
1. Manual
2. Peak
3. Cycle
4. Step
5. Advanced
ADVANCED s
ID: ………..
Steps: ….
Ref. Pos. Set
Ref. Pos. : ….
Cycles: ….
Auto Return: ON/OFF
Break Stop: ON/OFF
SAVE SAVE&LOAD EXIT

USER MANUAL 11
_____________________________________________________________________________________________________________________
The picture on the left shows example of
setting Step 1.
To configure each Step user can select from below options:
Action:
Move Up –moving up the force meter
Move Down –moving down the force meter
Hold –no movement
Const. Force –automatic move that is maintaining constant force
on the force meter
Speed:
Inscribing movement speed (20-300 mm/min range)
End:
Travel –Distance option will show up where user can inscribe
travel in [mm].
Time –Duration option will show where user can inscribe time in
[s].
Sample break –automatic detection of sample break
Force –Condition (greater or less) and Force (value in Newtons)
options will show up
Position –Point option will show where user can inscribe exact
position point in [mm]
After all configuration is done, user by pressing key can select to Save ,
Save&Load or Exit.
After selecting Load below screen will show up:
Actual data of the measurement will show
up. User can by using the knob select Start
to start the measurement or Select to select
other motion program.
ADVANCED s
STEP 1 g
Action: Move Down
Speed: 75mm/min
End: Travel
Distance: 10.00mm
SAVE SAVE&LOAD EXIT
Profile 1 s
Cycle No: 0
Step No: 0
Speed: 0 mm/min
Distance: 0.00 mm
Force: 0,00 N
Start Select s

12 USER MANUAL
_____________________________________________________________________________________________________________________
11.2 Manual, Peak, Cycle and Step mode
Manual mode enables to move the force meter by using the knob on the keyboard.
Peak, Cycle and Step modes are simplified modes of Advanced mode.
Peak –used when user wants to measure single peak force.
Cycle –used when user wants to perform many cycles on a object to check its
durability.
Step - used when user wants to set motion steps based on force meter movement
up and down.
12. Main menu
After turning on the stand following menu appears:
User by turning knob changes selected position on the screen and enters it by
pressing the knob or →key. Exit from selected option by pressing ←.
12.1 Home position
Home position –this option moves the force meter to base position. STAV will
also remind about that before loading motion program.
Thanks to base position driver can evaluate start position.
Setting base position is required to use automatic modes.
Main menu s
1. Home position……..
2. Force gauge
3. Applications
4. Configuration
5. Info
6. Service
Reference position

USER MANUAL 13
_____________________________________________________________________________________________________________________
12.2 Force gauge
If force gauge is equipped with wireless module then Force gauge option is used
for connecting force gauge with stand.
Select Search option to search for any force gauge nearby.
12.3 Applications
Applications option is used for fitting
stand options to user’s needs. User can set
which work modes are available in
application/functions menu (which modes
are available after pressing key).
12.4 Configuration
- Units –setting units standard,
- Speed –setting max movement speed,
- Peak detect –minimal deviation in % to
state it is a peak,
- Min. Peak –minimal peak value,
- Overload –Set max force which can act
on force meter,
- Send Start –enables to send start
command to force meter by key on
stand,
- Send Zero –enables to zero value on
force meter,
- Interface –serial interface
communication parameters configuration,
- Printout –choosing what information is
send (to computer or printer),
- Time&Date –setting time and date,
- Password –setting password that secures
configuration options,
- Format profiles –erases motion program
profiles.
APPLICATIONS s
1. Manual: Enabled/Disabled
2. Peak: Enabled/Disabled
3. Cycle: Enabled/Disabled
4. Step: Enabled/Disabled
5. Advanced: Enabled/Disabled
6. Exit
CONFIGURATION s
1. Units: mm/min
2. Speed: 300 mm/min
3. Peak detect: 10%
4. Min. Peak: 1N
5. Overload: 499N
6. Send Start: Off/On
7. Send Zero: Off/On
8. Interface
9. Printout
10. Time&Date
11. Password
12. Firmware update
13. Restore defaults
14. Format profiles
15. Exit

14 USER MANUAL
_____________________________________________________________________________________________________________________
Communicates
Communicate/
state
Reason
Solution
POSITION
UNKNOWN
Reference position is not
known
Choose in main menu Reference
position
NO SUPPLY
Stand engine supply off
–security STOP buton
pressed
Turn off STOP button.
If the button is off then contact
AXIS service.
OVERLOAD
Stand loaded above
Fmax value
Change Fmax value or use other
sample which needs lower force. If
still the stand is overloaded contact
AXIS service.

USER MANUAL 15
_____________________________________________________________________________________________________________________
Declaration of Conformity
The last two digits of the year in which the CE marking was affixed: 19
We:
AXIS Spółka z o.o. 80-125 Gdańsk, ul.Kartuska 375B
confirm with all responsibility that the stand:
STAV500
marked with comply with the following:
Directive 2004/108/EWG EWG (electromagnetic compatibility) and harmonized norms:
-EN 61000-6-3:2008+A1:2012
-EN 61000-4-3:2007 +A1:2008+A2:2011
Informacje dodatkowe:
Additional information:
-Conformity evaluation were carried out by Laboratorium Badawcze Oddziału Instytutu
Elektrotechniki in Gdańsk, accredited by PCA (AB007),examination report nr 037/LMC-
934/2014 from 20.05.2014 r.
Per pro Director of AXIS Sp. z o.o.:
Production Manager Jan Kończak _______________ Gdańsk, 22-10-2018 r.

16 USER MANUAL
_____________________________________________________________________________________________________________________
Notes
Table of contents