BandLuxe E580 Series User manual

E580 Series
(Embedded SIM)
Installation Guide

67
5
44
123
Product Overview
DATA
IN
P+DATA
OUT
POWER IN
DATA
IN
P+DATA
OUT
POWER IN
1
2
Power: Power LED will remain lit while power is applied.
Signal strength: Indicate receive signal strength.
The Signal Strength LEDs are only used at the
power on to assist the installation.
The CPE will turn off all the Signal Strength LEDs after a
timer expires from power on. Such design is to prevent
the outdoor CPE becoming a potential target particularly
at night. The default time is 60 minutes however,
is user settable in the web GUI.
Mount base: Attach the mounting bracket.
Earth ground terminal: It is necessary to
connect a grounding wire to protect the CPE
from ESD (electrostatic discharges) and lightning.
Ethernet port: Connect to a computer using an
Ethernet cable.
Reset button: Short press to
restart the device. Long press for
for 10 seconds to reset the settings
to the factory default settings.
External SIM card slot: The CPE has
3
4
5
6
7
LTE Outdoor CPE Mounting bracket
Passive PoE adapter (E580A series) Passive PoE adapter (E580P series)
Optional: Plug head water
resistant kits (RJ-45)
Package Contents
1
Sprint embedded SIM inside. Please
insert the external SIM card for special
application.

2
Install external SIM card
Notice before installation
Step 1: Unscrew the SIM card slot.
Step 2: Insert a valid SIM card into the SIM card
slot. Push it fully until it clicks into place.
Step 3: Screw the cap back on tightly.
Once the external SIM is plug in,
the embedded SIM will no longer be activated.
Choose a solid and safe place (Wall or Pole) for CPE installation
Note:
For optimum reception, there are few things you should consider before
installation. Please see Appendix 2 for important installation considerations.
Prepare two Ethernet cables
Prepare wrenches
Prepare adjustable wrenches or four combination wrenches
(size: 13mm x 2, 8mm x 1, and 19mm x 1)
1
3
Be sure that one of the cables used is an outdoor grade CAT 5e (or above)
Ethernet cable type and the length of the cables are adequate to reach the
location of the CPE and indoor PPoE.
Warning:
1. Do NOT start any traffic test (ex: throughput
test and internet browsing) before the
installer returns to the ground.
2. Do ground the CPE to provide protection
from ESD (electrostatic discharges) and lightning.
2
The CPE has Sprint embedded SIM inside.
For special application that you have to use an
external SIM card, please follow below steps to
load the external SIM card.
- Choose the best location of the house and the
orientation of the CPE to get the strongest signal
reception from base station.
- The ambient temperature for E580 series
must be within:
E580A series : -10°C to 55°C
E580P series : -40°C to 55°C
SIM card

3
Mount assembly package
A B C D
Kit-1
Quantity: 1
Kit-2
Quantity: 1
Hex Head Bolt
(M8x50mm)
Quantity: 2
M8 Spring Washer
Quantity: 3
M N O P
Kit-4
Quantity: 1
1/2” U Bolt DN63
Quantity: 1
M13 Washer
Quantity: 2
M13 Spring
Washer
Quantity: 2
Q
1/2 Hexagon Nuts
Quantity: 2
E F
Washer M8x22
(OD) mm
Quantity: 2
M8 Hexagon Nuts
Quantity: 2
G H
Hex Head Bolt
(M5x35mm)
Quantity: 2
Spring Washer
(M5)
Quantity: 6
I J K L
Kit-3
Quantity: 1
Washer (M8)
Quantity: 1
Hex. Head Bolt
(M5x20mm)
Quantity: 4
Washer (M5)
Quantity: 4
27
21.6
18.72
12.7
7.9
7.9
16
22
13
13
13.5
8.9

4
Wall-mount Assembly
Step 1.
A
B
C
D
E
F
G
H
D
EF
G
H
I
D
C
J
Step 2.
Step 3.
H
H
H
K
K
K
L
L
L
H
L
K
Step 1: Align the mounting bracket on the wall. Using the bracket as
mounting template, mark the positions to drill the holes.
Step 2: Assemble the bracket as shown in the illustration.
Step 3: Attach the bracket to the back of the CPE.
Step 4: Hang the CPE to the wall and secure the bracket using the designated
screws and washers.

5
Pole-mount Assembly
Step 3.
H
H
H
K
K
K
L
L
L
H
L
K
Step 1.
A
B
C
D
E
F
G
H
D
EF
G
H
I
D
C
J
Step 2.
Step 1: Align the mounting bracket on the wall. Using the bracket as
mounting template, mark the positions to drill the holes.
Step 2: Assemble the bracket as shown in the illustration.
Step 3: Attach the bracket to the back of the CPE.

6
Insert the Ethernet cable
N
O
PQ
M
O
P
Q
For 1.5” to 2” diameter
Step 4.
N
O
PQ
O
PQ
For 2.5” diameter
Step 4.
Unscrew the Ethernet port and insert one
end of the Ethernet cable into the CPE port.
Note:
For best protection against dust and water,
ethernet cable MUST be fitted with a water-proof
RJ-45 jack. Please see Appendix 1 for water-proof RJ-45
cable jack assembly.
Step 4: Align a pole on the bracket and assemble the pole bracket as shown.
Step 5: Adjust the CPE position to an appropriate direction and secure the pole
bracket using the designated screws and washers.

7
Connect to PC
Prepare two Ethernet cables for connection.
Step 1: Insert the other end of the Ethernet cable to “P+D OUT” port of the
PoE adapter.
Step 2: Connect another Ethernet cable to a Network Hub/Router or directly
to PC/Laptop via PoE adapter (“Data/IN” port).
Step 3: Plug the PoE adapter to an electrical outlet.
Using Passive PoE adapter (E580A series)
Using Passive PoE adapter (E580P series)
LTE Outdoor CPE
PoE
PC/Laptop
Network Hub/Router
Data/IN
P+D/OUT
Step 2
Step 1
DATA
IN
P+DATA
OUT
POWER IN
Electrical outlet
Step 3
LTE Outdoor CPE
Adapter
PC/Laptop
Network Hub/Router
Data/IN
P+D/OUT
Step 2
Step 3
Step 1
DATA
IN
P+DATA
OUT
POWER IN
PoE
Electrical outlet

8
Adjusting CPE position
For optimum reception, fine tune the CPE orientation (horizontally or
vertically) to have the best signal strength shown from LED or other test
equipment.
Note: LEDs (on the front panel) indicate signal strength.
Horizontal angle adjustment
Step 1: Loose the top knob using the wrench as
shown.
Step 2: Swivel the device to the left or right
to face the direction of the base
station.
Step 3: Secure the knob using
the wrench after the
position is fixed.
Vertical angle adjustment
Step 1: Loose the side knob using the wrench as
shown.
Step 2: Adjust the device position up or down
to face the direction of the base
station.
Step 3: Secure the knob using the wrench
after the position is fixed.

9
Note
If you can NOT connect to the network, please follow below steps to set
APN manually.
1. Go to
Network > Mobile Internet > WWAN Setting- APN Profile Setting
to enter the APN profile name, then click Add.
2. Enter APN, User Name, and Password, then click Save.
3. Go to Network > Mobile Internet > WWAN Setting- Network Setting
to configure the APN to Manual. Then select the Profile Name you
added from the Profile Selection, then click Apply.
Above change will be applied after the system is rebooted.
Once the external SIM is reinserted, you must restart the CPE to read the
SIM card properly.
For more detail information, please go to
http://www.bandrich.com/UM/E580_Embedded_Series.pdf
to download User Manual.
Using web management
Step 1: Enter the IP address (http://192.168.1.1) of the CPE in your
browser’s address bar then press Enter.
Step 2: On the opening screen, enter the username (admin) and password
(admin).
Step 3: Click OK to login to the main screen.
.
Step 4: Click one of the header tabs for advanced features.
E580 series CPE uses network domain 192.168.1. X.
For any downstream connections, all devices should avoid using this
network domain otherwise there might be IP address conflict and cause
communication failure.
If the PIN verification on your SIM card is enabled, please go to
Network > Mobile Internet > UICC/SIM PIN Management to unlock the
PIN code.

Appendix 1.
Water-proof RJ-45 cable jack assembly
Strip Cable Sheath
Recommended Wire
Gauge: 24AWG
2
Insert The Lock Nut
Into The Housing.
3
Insert The Seal At
The Back End Of The
Housing.
4
Insert The Cable All
The Through.
Crimp The RJ45 Plug 1 Insert The Plug Into
The Hohsing And
Keep The Plug Close
To Housing.
1. First Tighten Lock Nut
2. Then Screw Sealing
Nut Torque Value
Is 6~8Kgf/cm
10
Sealing Nut
Lock Nut
Seal
Housing
Gasket
RJ45 Plug
40.0(REF)
3.5(REF)
7.7
Crimp The RJ45 Plug
Plug
Lock Nut
Seal
Cable
1
56 7

11
Important Installation Considerations
Before installing the outdoor CPE, consider the appropriate location,
clearance, and device orientation.
Location and Cable wiring
Consult your Service Provider to find the best location and angle for
getting the strongest signal from the base station.
Mount the CPE at the highest possible location with a clear view of the
base station signal source. Buildings or other obstructions will affect the
quality of the signal you receive.
Keep the best distance as possible from other devices that may cause
interference.
Check if you can route the cable through the available ventilation holes
to avoid unnecessary drilling and waterproofing the wall.
Disconnect the power cord first before mounting the CPE.
Otherwise this may result in personal injury due to electric shock.
Mounting
Choose a solid wall/ground to mount the CPE.
Mount on a wall/pole that can sustain the CPE dimensions and weight.
Mount upright on a vertical surface.
Appendix 2.
Do a walking test around the house to find the best spot with the
strongest signal if you don’t obtain related information from your
Service Provider.
1
1

Warning:
To receive stronger signal, please do NOT
place your head or body in front of the
CPE while you are positioning the CPE
or checking the signal strength LEDs on
the front panel.
Position Adjustment
The CPE must be directed towards the nearest base station. By pointing
the CPE in the proper direction ensures that you receive the strongest
signal.
Fine tune the signal by
adjusting the orientation
horizontally or vertically to
increase the CPE signal
strength.
To verify the signal strength level:
Check the LEDs on the front panel - increasing lighted LEDs indicates
stronger signal.
Access the web management and go to Status > Mobile Network >
Information to view the Rx Signal Strength.
Appendix 2.
12
13

P/N: 68060211021 Rev.A
68060211021
Table of contents
Popular Antenna manuals by other brands

Comba Telecom
Comba Telecom CriticalPoint UHF DAS user manual

Vivanco
Vivanco TVA 202 operating instructions

Ruijie Networks
Ruijie Networks RG-ANTx3-5800D Hardware installation and reference guide

COBHAM
COBHAM SAILOR 60 GX-R2 4.5 W installation manual

SureCall
SureCall SC-248W user manual

Winegard
Winegard WX980 product manual

Ten-Haaft
Ten-Haaft Oyster Premium Mounting instruction

Monster
Monster MAVA5011H user manual

Valcom
Valcom AS-3226B/URC Technical manual

M2 Antenna Systems
M2 Antenna Systems 6M-3SS Assembly manual

Inmarsat
Inmarsat BGAN Thrane&Thrane Explorer 500 user manual

Tarheel Antennas
Tarheel Antennas 40A-HP instruction manual