ELECTRONIC PARAMETERS
Power supply: 4*AA alkaline batteries
Alarm voltage: DC 4.2V±0.2V
Static current: ≤30uA
Dynamic current: ≤400mA
Working temperature: 0℃~55℃
Working humidity: 20% ~ 93% ±2RH

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
3
NOTICES
Position the smart safe in a level and a covert area.
Place the smart safe in cool and dry place.
Avoid direct sunlight.
Do not dismantle the smart safe privately.
Do not tread on the smart safe.
Do not mix the different types of batteries or mix new batteries and the old batteries together.
Make sure that the positive and negative electrodes are connected correctly.
The man-made destruction is not on the warranty in the contract scope.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
4
MATERIAL CONTAINED INSIDE THE PACKAGING

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
5
INSATLLATION
When you received the smart safe, you need to carry out some simple operations.
INTRODUCING BATTERIES
Remove the protective lid unscrewing the screws, and fit the batteries into their seats.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
6
ASSIGNING IB CARD CODE
The safe needs an initial setting for the assignment of the IB card code which comes with it. This code varies,
depending on the IB card and must be assigned to the safe proceeding as follows.
Place the IB card against the receiver, an acoustic signal (“beep”) will confirm assignment of the code
NOTICE
When installing, always make sure that the IB card opens the safe.
POSITION
Now you can position the smart safe on the top of a piece of furniture, or inside a cabinet. Lock it in place
using the 2 wooden screw provided with the smart safe. For fastening in place, the smart safe has 4 through
holes –2 on the back wall and 2 on the horizontal surface. The installer should use these, at his own
discretion, depending on where the smart safe is to be placed.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
7
DRILLING DIAGRAMS
SMART SAFE 3001D-1GL
SMART SAFE 3001D-3GL
SMART SAFE 3001D-5GL

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
8
USER INSTRUCTIONS
Now the smart safe is delivered to the user with the door open and ready to use.
ASSIGNING OWNER KEY
Make sure that the smart safe has been initialized.
Place an IB card against the receiver; an acoustic signal will confirm assignment of the card.
Only one owner key is allowed.
CHANGE AN OWNER KEY
Loose the screws of the back lock housing and remove the cover.
Press the Reset button of the PCB and follow the above procedure to assign a new owner key.
NOTICE
Once the owner key was deleted, the master key and the code will be deleted also.
ASSIGNING MASTER-KEY
Press */Cbutton, the display will show LIGHT_ON.
Place the owner key against the receiver, the display will show Pafter one beep.
Place the owner key against the receiver again.
Place another IB card against receiver, the display will show P_S1 after one beep, master key will
be confirmed assignment. (Master key assignment can be continue before display off, the display
will show P_S2…P_S5 till to FULL show on display)
DELETE SOME MASTER KEY
Press */C button, the display will show LIGHT_ON.
Place the owner key against the receiver, the display will show Pafter one beep.
Place the owner key against the receiver again.
Place a master key against the receiver, the display will show P_S1 after 2 beeps, the master key
will be deleted. (Master key can be deleted until the display off)
DELETE ALL MASTER KEY
Press */C button, the display will show LIGHT_ON.
Place the owner key against the receiver, the display will show Pafter one beep.
Place the owner key against the receiver two times again, the display will show P_ED, now all the
master key will be deleted.
CLOSING AND OPENING THE SAFE
To close the safe, the user must keep the door
pressed and key the code onto the keyboard,
followed by the key #. This code may consist
of anything between one and nine digits, at the
discretion of the user.
To indicate that the door has closed, a green
LED lights up in the receiver.
To open the safe, you just key in the same
code followed by the key #. As you set the
code, if you key in a wrong digit, you can press
* to delete it and write in the right digit.
You can change the secret code during any
safe closing or opening cycle.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
9
USING THE IB CARD
If you forget the code when the safe is shut, you can open it again by using the IB card. To do so, process as
follows.
Place the IB card again the receiver, an acoustic signal (“beep”) will confirm the opening of the safe.
USING THE MECHANICAL KEY
In case of accidental loss of the IB card, or a fault on the electronic board, you can open the safe with the
mechanical key, proceeding as follows.
Take the front adhesive off from the door and put the mechanical key –provided with the product –into the
lock. You may now open the door manually.
NOTICE
Never leave the mechanical key and the IB card inside the safe.
ALARM FUNCTION
When someone key in the wrong code, after the third attempt, the safe will let out an acoustic alarm signal
lasting sixty seconds, and will be blocked.
After sixty seconds, the safe will keep quiet again.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
10
REPLACING THE BATTERIES
If the green LED flashes for about eight seconds and the safe lets out an acoustic signal (“beep”), the
batteries need to be replaced.
In order to do so, remove the protective lid unscrewing the screw and replace the run out batteries with the
new ones.
NOTICE
Make sure that the batteries used are of an alkaline 1.5 Volt type.
EMERGENCY POWER SUPPLY
If the batteries are not replaced before they run out completely, you can put a 9V battery against the two
contacts on the right, to feed the safe temporarily, and hence open it.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
11
UNIVERSAL SOCKET (OPTIONAL)
On request, a universal power socket can be provided. It will be located on the inside of the door of the safe. It
can connect various devices –for example, a personal computer or a cell phone battery charger –to the
power mains. The power supply cable of this socket comes out from the back of the safe, and ends with three
small cables (phase, neutral and earth) which can be
directly connected to the terminals of the wiring system, or to
a normal plug. In case of direct connection to the wiring
system, the wiring system must be equipped with a
complete line cut off device, with a contact opening distance
of at least 3.5mm. If the power supply cable is connected to
a normal plug, the plug must be perfectly accessible.
NOTICE
If the power supply cable is damaged for any reason
whatsoever, disconnect it from the power supply system –or
take the plug out of the socket –and get in touch with our
Sales Service.
SMART SAFE SYSTEM (OPTIONAL)
The system is used to memorize the openings of the smart safe, in a data archive. This system manages the
archive according to the customer code used and the kind of key used. (IB card or mechanical card),
showing the date and time the smart safe was opened.
NOTICE
To install the program, you need the following minimum system requirements:
OS: Windows XP, Windows 2000, Windows 98
Ram memory: 64MB Ram
Processor: Pentium Ⅲ

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
12
SOFTWARE INSTALLATION
First of all, fit the installation CD into the computer reader and then start up the installation software called
SETUP inside the CD.
After that, a series of installation windows will open consecutively, guiding the user step by step to installing
the software.
This window shows the version of the driver.
Press the Next button to proceed with the
installation.
Press the Cancel button to exit.
In this window, you must select the language for
the system, there are two languages to select, the
simple Chinese and the English.
Select the language which you are needed, then
press the OK.
This window will ask you to fill in your name and
your company name.
Press the Next button to proceed with the
installation.
Press the Back button to go back to the previous
windows.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
13
This window asks the user to choose the path to
the software.
Press the Browse button to select any other
destination.
This window will ask the user to select the Setup
type. There are three types to be selected.
After select a type, press the Next button to the
next steps.
This window will ask you to choose the
components which you want to install, and clear
the components you do not want to. Click the
Next button to the next step.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
14
This window will ask you to select a program
folder; we can name this folder as Smart Safe.
Press the button Next to the next step.
The installation is now finished.
Press the button Finish to finish the operation.
ENCODER INSTALLATION
The encoder supplies two ports to connect to the computer, the USB port (DS9490R) and the serial port
(DS9097U). The serial port is not need to install the drivers. But if you select the USB port, the drivers must
be installed.
FOR WINDOWS XP, WINDOWS 2000,
WINDOWS 98
This window asks you to choose the kind of
installation. On the first screen, choose No, not
now, then click Next, choose install software
automatically (suggested choice) on the second
screen and then click Next. Press the button
Cancel if you do not wish to perform the
installation.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
15
This window asks for the path to choose the driver for the
USB unit, model DS9490. Press the Browse button, in the
folder C:\Program Files\Be-Tech\Smart Safe
V2009.07\Driver and then choose the file
ds2490winusb_x86.inf, press the button OK to continue
installation.
The installation of the driver is now complete. Press Fine
button to complete the installation.
NOTICE
There are two kinds of driver software in the RW-32 folder, the WinUSB_32 folder is used for the 32 bit
computer, the WinUSB_64 folder is used for the 64 bit computer.
For Windows Vista
User Account Control (UAC) can help you prevent unauthorized changes to your computer. It works by
prompting you for permission when a task requires administrative rights, such as installing software or
changing settings that affect other users. But it will block many drivers so that a lot of software can’t use in
Vista. User should turn UAC off before installing smart safe software. The follow procedure will show you ho
to turn User Account Control off.
Open User Accounts by clicking the Start button,
clicking Control Panel, clicking User Accounts
and Family Safety (or clicking User Accounts,
if you are connected to a network domain), and
then clicking User Accounts.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
16
Click Turn User Account Control on or off. If
you are prompted for an administrator password
or confirmation, type the password or provide
confirmation.
Select the Use User Account Control (UAC) to
help protect your computer check safe to turn
on UAC, or clear the check safe to turn off UAC,
and then click OK
Open the folder which is the system software in. The
default path is C:\Program Files\Be-Tech. Then open the
Driver folder.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
17
The WinUSB_32 folder is used for the 32 bit
computer, the WinUSB_64 folder is used for the
64 bit computer. Select a correct folder to open.
Double click the install_wire_driver_x86_v401
to process the driver’s installation.
This window will ask you to read the drivers
license agreement. Check the square and press
the Install button to process the installation.

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
18
The driver is installing, please wait until the
installation is finished.
The driver is finished completely. Press the
Finish to exit the installation.
OPERATOR INTERFACE

SMART SAFE 3001D-1GL/3GL/5GL
SMART SAFE 3001D 1GL/3GL/5GL
19
INITIAL SETTINGS
For the serial interface select DS9097U. For the USB interface select DS9490. Beside, you can also select
the kind of COM port used, like COM1 and COM2, etc.
The button Holders is used to read key ID, register holder key, revise holder key and delete holder key.
The buttonAudit Trail is used to make a data card, in order to query the information of the smart safe.
The button ClockAdjustment is used to make a time card, in order to set the time into the safe.
REGISTER THE HOLDERS
This manual suits for next models
2
Table of contents
Popular Other manuals by other brands

Aqua One
Aqua One Windsor 88 Assembly instructions

GIGA-TMS
GIGA-TMS TS100 series Hardware user's guide

MRHANDSFREE
MRHANDSFREE FAMILY CHARGER Technical specifications

Aero-motive
Aero-motive 11207 installation instructions

Aqua One
Aqua One Royale 90 Assembly instructions

Purpleline
Purpleline kojack KJ4T user manual