bebob factoryGmbH – Höglwörtherstr. 350 – D-81379München – Tel.: +49 89 27818282
www.bebob.de
April2016
BatterySwap
·The ML-120ALEXdetectsa batteryasemptywhen the voltage dropsbelow12,5V
·The ML-120ALEXinstantlytakesoverpowering theARRI AlexaandtheD-Tap port fora
maximumof2 minutesanddisplaysa redLED alarm
·The LEDAlarmflashesfor90s, turnsto solid forthe last 30s.
·Afterthe emptybatteryhasbeen replacedbya charged one (voltage underload of over
14,5V), powering ofthe ARRI Alexainstantlyrevertstothe V-Mount battery.
·The ML-120ALEXswitchesup to 6 Timesbefore running empty
·Ifthe emptybatteryisnot replaced within2 minutesthe ML-120ALEXand the ARRI Alexa
willswitchoff.
Alarm LED´sbrightness
·To allowthe AlarmLED to be visibleinbright environments(sunlight etc.)butnot
disturbinglyoverbrightindarkerenvironments(studioetc.), the ML-120 hasautomatic
brightness adjust.
·The brighterthe environment the brighterthe alarmLEDwill show.
·The environment lightdetectorislocated at the top – middle ofthe ML-120 housing.
·Covering the housing (withtape forinstance)willswitch off the automaticbrightness adjust
and the alarmLEDwillflashwith minimumbrightness
Safetyinstructions
·Onlyforprofessionaluse!Keep Chargerout ofreachofchildren and personnelthat has
not beeninstructed in the use!
·Use onlywith recommended batteries.
·Keep the ML-120ALEXdryand do not immerse inwater.
·Do not attempt to open orrepairthe ML-120V7V. Contact yourdealerforhelp ifit becomes
defective.
·Handlewithcare!Do not throw!Do not drop!
Warranty
·The ML-120ALEXiscovered bya 2years unconditionalwarrantyon allparts,except the
cells.
·The cellsare covered bya 2yearwarranty,80%oftheoriginalcapacity.
·Forwarrantyissuesorif you haveanyadditionalquestions,please contact the appropriate
bebob distributorlisted at www.bebob.de.