Belden grass valley GV K-FRAME X Technical manual

Installation Planning Guide
13-00010-000AA
2/22/18
GV K-FRAME X
VIDEO PRODUCTION FRAMES

ii
Notices
Copyright and Trademark Notice
Copyright © 2018, Grass Valley USA, LLC. All rights reserved.
Belden, Belden Sending All The Right Signals, and the Belden logo are trademarks or
registered trademarks of Belden Inc. or its affiliated companies in the United States and
other jurisdictions. Grass Valley, GV K-Frame X, Kayenne, Karrera, and GV Korona are
trademarks or registered trademarks of Grass Valley USA, LLC. Belden Inc., Grass Valley USA,
LLC, and other parties may also have trademark rights in other terms used herein.
Terms and Conditions
Please read the following terms and conditions carefully. By using K-Frame Video
Production Switcher documentation, you agree to the following terms and conditions.
Grass Valley hereby grants permission and license to owners of K-Frame Video Production
Switchers to use their product manuals for their own internal business use. Manuals for
Grass Valley products may not be reproduced or transmitted in any form or by any means,
electronic or mechanical, including photocopying and recording, for any purpose unless
specifically authorized in writing by Grass Valley.
A Grass Valley manual may have been revised to reflect changes made to the product
during its manufacturing life. Thus, different versions of a manual may exist for any given
product. Care should be taken to ensure that one obtains the proper manual version for a
specific product serial number.
Information in this document is subject to change without notice and does not represent a
commitment on the part of Grass Valley.
Warranty information is available in the Support section of the Grass Valley Web site
(www.grassvalley.com).
Title GV K-Frame X Installation Planning Guide
Part Number 13-00010-000AA
Revision 22 February 2018, 10:03 am

iii
GV K-Frame X
Installation Planning Guide
Important Safeguards and Notices
Symbols and Their Meanings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
This section provides important safety guidelines for operators and service personnel.
Specific warnings and cautions appear throughout the manual where they apply. Please
read and follow this important information, especially those instructions related to the risk
of electric shock or injury to persons.
Symbols and Their Meanings
Important Safeguards and Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Indicates that dangerous high voltage is present within the equipment
enclosure that may be of sufficient magnitude to constitute a risk of electric
shock.
Indicates that the user, operator or service technician should refer to the product
manuals for important operating, maintenance, or service instructions.
This is a prompt to note the fuse rating when replacing fuses. The fuse
referenced in the text must be replaced with one having the ratings indicated.
Identifies a protective grounding terminal which must be connected to earth
ground prior to making any other equipment connections.
Identifies an external protective grounding terminal which may be connected to
earth ground as a supplement to an internal grounding terminal.
Indicates that static sensitive components are present, which may be damaged
by electrostatic discharge. Use anti-static procedures, equipment and surfaces
during servicing.
Indicates that the equipment has more than one power supply cord, and that all
power supply cords must be disconnected before servicing to avoid electric
shock.
The presence of this symbol in or on Grass Valley equipment means that it has
been tested and certified as complying with applicable Canadian Standard
Association (CSA) regulations and recommendations for USA/Canada.
The presence of this symbol in or on Grass Valley equipment means that it has
been tested and certified as complying with applicable Underwriters Laboratory
(UL) regulations and recommendations for USA/Canada.

iv
Notices
Warnings
Important Safeguards and Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
A warning indicates a possible hazard to personnel, which may cause injury or
death. Observe the following general warnings when using or working on this
equipment:
• Appropriately listed/certified mains supply power cords must be used for the
connection of the equipment to the mains voltage at either 120 V AC or 240 V AC.
• This product relies on the building's installation for short-circuit (over-current)
protection. Ensure that a fuse or circuit breaker for 120 V AC or 240 V AC is used on the
phase conductors.
• Any instructions in this manual that require opening the equipment cover or enclosure
are for use by qualified service personnel only.
• Do not operate the equipment in wet or damp conditions.
• This equipment is grounded through the grounding conductor of the power cords. To
avoid electrical shock, plug the power cords into a properly wired receptacle before
connecting the equipment inputs or outputs.
• Route power cords and other cables so they are not likely to be damaged. Properly
support heavy cable bundles to avoid connector damage.
• Disconnect power before cleaning the equipment. Do not use liquid or aerosol
cleaners; use only a damp cloth.
• Dangerous voltages may exist at several points in this equipment. To avoid injury, do
not touch exposed connections and components while power is on.
• High leakage current may be present. Earth connection of product is essential before
connecting power.
• Prior to servicing, remove jewelry such as rings, watches, and other metallic objects.
• To avoid fire hazard, use only the fuse type and rating specified in the service
instructions for this product, or on the equipment.
• To avoid explosion, do not operate this equipment in an explosive atmosphere.
• Use proper lift points. Do not use door latches to lift or move equipment.
• Avoid mechanical hazards. Allow all rotating devices to come to a stop before servicing.
• Have qualified service personnel perform safety checks after any service.
The presence of this symbol in or on Grass Valley equipment means that it has
been tested and certified as complying with applicable Intertek Testing Services
regulations and recommendations for USA/Canada.
The presence of this symbol in or on Grass Valley product means that it complies
with all applicable European Union (CE) directives.
The presence of this symbol in or on Grass Valley product means that it complies
with safety of laser product applicable standards.

v
GV K-Frame X
Installation Planning Guide
Cautions
Important Safeguards and Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
A caution indicates a possible hazard to equipment that could result in equipment
damage. Observe the following cautions when operating or working on this
equipment:
• This equipment is meant to be installed in a restricted access location.
• When installing this equipment, do not attach the power cord to building surfaces.
• Products that have no on/off switch, and use an external power supply must be
installed in proximity to a main power outlet that is easily accessible.
• Use the correct voltage setting. If this product lacks auto-ranging power supplies,
before applying power ensure that each power supply is set to match the power
source.
• Provide proper ventilation. To prevent product overheating, provide equipment
ventilation in accordance with the installation instructions.
• Do not operate with suspected equipment failure. If you suspect product damage or
equipment failure, have the equipment inspected by qualified service personnel.
• To reduce the risk of electric shock, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so. Refer all
servicing to qualified service personnel. Servicing should be done in a static-free
environment.
• This unit may have more than one power supply cord. Disconnect all power supply
cords before servicing to avoid electric shock.
• Follow static precautions at all times when handling this equipment.
Electrostatic Discharge (ESD) Protection
Electrostatic discharge occurs when electronic components are improperly
handled and can result in intermittent failure or complete damage adversely
affecting an electrical circuit. When you remove and replace any card from a frame
always follow ESD-prevention procedures:
• Ensure that the frame is electrically connected to earth ground through the power cord
or any other means if available.
• Wear an ESD wrist strap ensuring that it makes good skin contact. Connect the
grounding clip to an unpainted surface of the chassis frame to safely ground unwanted
ESD voltages. If no wrist strap is available, ground yourself by touching the unpainted
metal part of the chassis.
• For safety, periodically check the resistance value of the antistatic strap, which should
be between 1 and 10 megohms.
• When temporarily storing a card make sure it is placed in an ESD bag.
Note: Limited access restrictions apply to Video Processor Frames and
Servers, not to operator controlled equipment such as Control Panels,
Menus, Aux Panels, etc.

vi
Notices
• Cards in an earth grounded metal frame or casing do not require any special ESD
protection.
Battery Handling
This product includes a backup battery. There is a danger of explosion if the battery
is replaced incorrectly. Replace the battery only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the
manufacturer’s instructions. Before disposing of your Grass Valley equipment, please
review the Disposal and Recycling Information appendix.
Cautions for LCD and TFT Displays
Excessive usage may harm your vision. Rest for 10 minutes for every 30 minutes of
usage.
If the LCD or TFT glass is broken, handle glass fragments with care when disposing
of them. If any fluid leaks out of a damaged glass cell, be careful not to get the liquid crystal
fluid in your mouth or skin. If the liquid crystal touches your skin or clothes, wash it off
immediately using soap and water. Never swallow the fluid. The toxicity is extremely low
but caution should be exercised at all times.
Mesures de sécurité et avis importants
Signification des symboles utilisés . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Mises en garde . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
La présente section fournit des consignes de sécurité importantes pour les opérateurs et le
personnel de service. Des avertissements ou mises en garde spécifiques figurent dans le
manuel, dans les sections où ils s’appliquent. Prenez le temps de bien lire les consignes et
assurez-vous de les respecter, en particulier celles qui sont destinées à prévenir les
décharges électriques ou les blessures.
Signification des symboles utilisés
Signale la présence d’une tension élevée et dangereuse dans le boîtier de
l’équipement ; cette tension peut être suffisante pour constituer un risque de
décharge électrique.
Avertit l'utilisateur, l’opérateur ou le technicien de maintenance que des
instructions importantes relatives à l'utilisation et à l'entretien se trouvent dans
la documentation accompagnant l’équipement.
Invite l'utilisateur, l’opérateur ou le technicien de maintenance à prendre note du
calibre du fusible lors du remplacement de ce dernier. Le fusible auquel il est fait
référence dans le texte doit être remplacé par un fusible du même calibre.

vii
GV K-Frame X
Installation Planning Guide
Avertissements
Mesures de sécurité et avis importants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Les avertissements signalent des conditions ou des pratiques susceptibles
d’occasionner des blessures graves, voire fatales. Veuillez vous familiariser avec les
avertissements d’ordre général ci-dessous :
• Un cordon d’alimentation dûment homologué doit être utilisé pour connecter
l’appareil à une tension de secteur de 120 V CA ou 240 V CA.
Identifie une borne de mise à la terre de protection. Il faut relier cette borne à la
terre avant d’effectuer toute autre connexion à l’équipement.
Identifie une borne de mise à la terre externe qui peut être connectée en tant
que borne de mise à la terre supplémentaire.
Signale la présence de composants sensibles à l’électricité statique et qui sont
susceptibles d’être endommagés par une décharge électrostatique. Utilisez des
procédures, des équipements et des surfaces antistatiques durant les
interventions d’entretien.
Le symbole ci-contre signifie que l’appareil comporte plus d’un cordon
d'alimentation et qu’il faut débrancher tous les cordons d'alimentation avant
toute opération d’entretien, afin de prévenir les chocs électriques.
La marque C-CSA-US certifie que l’appareil visé a été testé par l'Association
canadienne de normalisation (CSA) et reconnu conforme aux exigences
applicables en matière de sécurité électrique en vigueur au Canada et aux États-
Unis.
La marque C-UL-US certifie que l’appareil visé a été testé par Underwriters
Laboratory (UL) et reconnu conforme aux exigences applicables en matière de
sécurité électrique en vigueur au Canada et aux États-Unis.
La marque ETL Listed d’Intertek pour le marché Nord-Américain certifie que
l’appareil visé a été testé par Intertek et reconnu conforme aux exigences
applicables en matière de sécurité électrique en vigueur au Canada et aux États-
Unis.
Le marquage CE indique que l’appareil visé est conforme aux exigences
essentielles des directives applicables de l’Union européenne en matière de
sécurité électrique, de compatibilité électromagnétique et de conformité
environnementale.
Le symbole ci-contre sur un appareil Grass Valley ou à l’intérieur de l’appareil
indique qu’il est conforme aux normes applicables en matière de sécurité laser.

viii
Notices
• La protection de ce produit contre les courts-circuits (surintensités) dépend de
l’installation électrique du bâtiment. Assurez-vous qu'un fusible ou un disjoncteur pour
120 V CA ou 240 V CA est utilisé sur les conducteurs de phase.
• Dans le présent manuel, toutes les instructions qui nécessitent d’ouvrir le couvercle de
l’équipement sont destinées exclusivement au personnel technique qualifié.
• N’utilisez pas cet appareil dans un environnement humide.
• Cet équipement est mis à la terre par le conducteur de mise à la terre des cordons
d’alimentation. Pour éviter les chocs électriques, branchez les cordons d’alimentation
sur une prise correctement câblée avant de brancher les entrées et sorties de
l’équipement.
• Acheminez les cordons d’alimentation et autres câbles de façon à ce qu’ils ne risquent
pas d’être endommagés. Supportez correctement les enroulements de câbles afin de
ne pas endommager les connecteurs.
• Coupez l’alimentation avant de nettoyer l’équipement. Ne pas utiliser de nettoyants
liquides ou en aérosol. Utilisez uniquement un chiffon humide.
• Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement.
Pour éviter toute blessure, ne touchez pas aux connexions ou aux composants exposés
lorsque l’appareil est sous tension.
• Avant de procéder à toute opération d’entretien ou de dépannage, enlevez tous vos
bijoux (notamment vos bagues, votre montre et autres objets métalliques).
• Pour éviter tout risque d’incendie, utilisez uniquement les fusibles du type et du calibre
indiqués sur l’équipement ou dans la documentation qui l’accompagne.
• Ne pas utiliser cet appareil dans une atmosphère explosive.
• Présence possible de courants de fuite. Un raccordement à la masse est indispensable
avant la mise sous tension.
• Après tout travail d’entretien ou de réparation, faites effectuer des contrôles de sécurité
par le personnel technique qualifié.
Mises en garde
Mesures de sécurité et avis importants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Les mises en garde signalent des conditions ou des pratiques susceptibles
d’endommager l’équipement. Veuillez vous familiariser avec les mises en garde ci-
dessous :
• L’appareil est conçu pour être installé dans un endroit à accès restreint.
Remarque: Les restrictions d'accès s'appliquent aux châssis et serveurs de
traitement vidéo, et non aux équipements contrôlés par l'opérateur tels que les
panneaux de contrôle, les menus, les panneaux auxiliaires, etc.
• Au moment d’installer l’équipement, ne fixez pas les cordons d’alimentation aux
surfaces intérieures de l’édifice.
• Les produits qui n'ont pas d’interrupteur marche-arrêt et qui disposent d’une source
d’alimentation externe doivent être installés à proximité d'une prise de courant facile
d’accès.

ix
GV K-Frame X
Installation Planning Guide
• Si l’équipement n’est pas pourvu d’un modules d’alimentation auto-adaptables, vérifiez
la configuration de chacun des modules d'alimentation avant de les mettre sous
tension.
• Assurez une ventilation adéquate. Pour éviter toute surchauffe du produit, assurez une
ventilation de l’équipement conformément aux instructions d’installation.
• N’utilisez pas l’équipement si vous suspectez un dysfonctionnement du produit. Faites-
le inspecter par un technicien qualifié.
• Pour réduire le risque de choc électrique, n'effectuez pas de réparations autres que
celles qui sont décrites dans le présent manuel, sauf si vous êtes qualifié pour le faire.
Confiez les réparations à un technicien qualifié. La maintenance doit se réaliser dans un
milieu libre d’électricité statique.
• L’appareil peut comporter plus d’un cordon d'alimentation. Afin de prévenir les chocs
électriques, débrancher tous les cordons d'alimentation avant toute opération
d’entretien.
• Veillez à toujours prendre les mesures de protection antistatique appropriées quand
vous manipulez l’équipement.
Protection contre les décharges électrostatiques (DES)
Une décharge électrostatique peut se produire lorsque des composants
électroniques ne sont pas manipulés de manière adéquate, ce qui peut entraîner
des défaillances intermittentes ou endommager irrémédiablement un circuit
électrique. Au moment de remplacer une carte dans un châssis, prenez toujours les
mesures de protection antistatique appropriées :
• Assurez-vous que le châssis est relié électriquement à la terre par le cordon
d'alimentation ou tout autre moyen disponible.
• Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau.
Connectez la pince de masse à une surface non peinte du châssis pour détourner à la
terre toute tension électrostatique indésirable. En l’absence de bracelet antistatique,
déchargez l’électricité statique de votre corps en touchant une surface métallique non
peinte du châssis.
• Pour plus de sécurité, vérifiez périodiquement la valeur de résistance du bracelet
antistatique. Elle doit se situer entre 1 et 10 mégohms.
• Si vous devez mettre une carte de côté, assurez-vous de la ranger dans un sac
protecteur antistatique.
• Les cartes qui sont reliées à un châssis ou boîtier métallique mis à la terre ne
nécessitent pas de protection antistatique spéciale.
Remplacement et élimination des piles
L’appareil renferme une pile. Pour réduire le risque d’explosion, vérifiez la polarité et
ne remplacez la pile que par une pile du même type, recommandée par le fabricant.
Mettez les piles usagées au rebut conformément aux directives du fabricant. Avant
de vous défaire de l’équipement, assurez-vous d’avoir lu l’appendice Disposal and Recycling
Information.

x
Notices
Précautions pour les écrans LCD et TFT
Regarder l’écran pendant une trop longue période de temps peut nuire à votre
vision. Prenez une pause de 10 minutes, après 30 minutes d’utilisation.
Si l'écran LCD ou TFT est brisé, manipulez les fragments de verre avec précaution au
moment de vous en débarrasser. veillez à ce que le cristal liquide n'entre pas en contact
avec la peau ou la bouche. En cas de contact avec la peau ou les vêtements, laver
immédiatement à l'eau savonneuse. Ne jamais ingérer le liquide. La toxicité est
extrêmement faible, mais la prudence demeure de mise en tout temps.
Recycling
Visit www.grassvalley.com for recycling information.
Certification and Compliance
Safety Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Restriction on Hazardous Substances (RoHS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Restriction on Hazardous Substances (RoHS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Safety Compliance
This equipment complies with the requirements of CSA/UL/IEC/EN 60950-1,
2nd Ed. + AM1: 2009, AM2:2013, AM22014, Safety of information technology
equipment.
The power cords supplied with this equipment meet the appropriate national
standards for the country of destination.

xi
GV K-Frame X
Installation Planning Guide
Restriction on Hazardous Substances (RoHS)
Restriction of Hazardous Substances (RoHS)
KAYN-2-25-2M-KC, KAYN-2-25-3M-KC, KAYN-3-35-
3M-KC, KAYN-3-35-4M-KC, KAYN-3-35-4M-KS, KAYN-
3-35-5M-KS, KAYN-4-35-4M-KS, KAYN-4-35-5M-KS,
KAYN-PNL-100-15, KAYN-PNL-200-25, KAYN-PNL-
200-35, KAYN-PNL-300-25, KAYN-PNL-300-35, KAYN-
PNL-400-25, KAYN-PNL-400-35, KOR-1-15-1M-KCS,
KOR-2-20-2M-KCS, KRR-2-25-2M-KC, KRR-2-25-C-
2M-KC, KRR-2-25-C-2M-KCS, KRR-2-25-2M-KCS,
KRR-2-25-3M-KC, KRR-3-35-3M-KCS, KRR-2-25-C-
3M-KC, KRR-3-35-3M-KC, KRR-3-35-4M-KC, KRR-3-
35-4M-KS, KRR-3-35-5M-KS, KRR-PNL-200-25, KRR-
PNL-200-25-C and KRR-PNL-300-35
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥㔶৺⭥㔶㓴Ԧ
Cables and Cable Assemblies
XOOO O O
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
ᱮ⽪㻵㖞
Display Assemblies
XOOO O O
㓴㻵仾ᡷ
Fan Assemblies
XOOO O O
䠁䴦Ԧ
Metal Parts
XOOO O O
ກᯉ઼㚊⢙䴦Ԧ
Plastic and Polymeric Parts
XOOO O O
KOR-PNL-100-15, KOR-PNL-200-20KRR-ELITE-25-PS
and KRR-ELITE-35-PS
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥㔶৺⭥㔶㓴Ԧ
Cables and Cable Assemblies
XOOO O O
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
ᱮ⽪㻵㖞
Display Assemblies
XOOO O O
䠁䴦Ԧ
Metal Parts
XOOO O O
ກᯉ઼㚊⢙䴦Ԧ
Plastic and Polymeric Parts
XOOO O O
K-FRM-100C, K-FRM-100CS and K-FRM-PSU
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥㔶৺⭥㔶㓴Ԧ
Cables and Cable Assemblies
XOOO O O
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
㓴㻵仾ᡷ
Fan Assemblies
XOOO O O
䠁䴦Ԧ
Metal Parts
XOOO O O
KSP-PNL-1ME-KBD
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥㔶৺⭥㔶㓴Ԧ
Cables and Cable Assemblies
XOOO O O
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
䠁䴦Ԧ
Metal Parts
XOOO O O
ກᯉ઼㚊⢙䴦Ԧ
Plastic and Polymeric Parts
XOOO O O
K-FRM-100S, K-FRM-100SX, K-FRM-100SX-I and
KOR-PNL-PSU
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)

xii
Notices
⭥㔶৺⭥㔶㓴Ԧ
Cables and Cable Assemblies
XOOO O O
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
䠁䴦Ԧ
Metal Parts
XOOO O O
KAYN-ELITE-PS, KAYN-PRO-PS, K-FRM-100CS-KIT,
K-FRM-CTRL-CS, K-FRM-INPUT, K-FRM-IO, K-FRM-
IO-10GE, K-FRM-ME-DPM-S, K-FRM-OUTPUT and
KRR-PRO-PS
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
䠁䴦Ԧ
Metal Parts
XOOO O O
KOR-PNL-LAN-20
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥㔶৺⭥㔶㓴Ԧ
Cables and Cable Assemblies
XOOO O O
KOR-PNL-KIT
䜘Ԧ〠 Part name
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
(Toxic or hazardous Substances and Elements)
䫵(Pb) ⊎(Hg) 䭹(Cd) භ௴撔
(Cr6)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟
(PBDE)
⭥䐟⁑ඇ
Circuit Modules
XOOO O O
O:
㺘⽪䈕ᴹ∂ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴ䟿൷൘
SJ/T 11364-2014
㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement in GB/T 26572-2011.
X: 㺘⽪䈕ᴹ∂ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴ䟿䎵ࠪ SJ/T 11364-2014 奬⭂䘬旸慷天㯪DŽ
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part is above the
limit requirement in GB/T 26572-2011.
ᢰᵟᶑⅮ䀓䟺˖
↔༠᰾ᡰᦞѻᮠᦞ⭡ Grass Valley ⧟ຳ㇑⨶䜘䰘ᡁԜⲴ䜘Ԧᓄ୶㧧DŽGrass Valley ޜؑ↔ؑⲴ↓⺞ᙗˈն⭡Ҿᮠᦞᶕ
ⓀҾޜཆ䜘ˈᡁԜᰐ⌅؍䇱ᆳⲴᆼᮤ઼߶⺞DŽᡰᴹ䘉Ӌ⢩ᙗ㜭൘ᵚ㧧䙊⸕Ⲵᛵߥлᴤ᭩DŽ!
Technical explanations:
This statement is based on the information provided by our suppliers of components and collected through our Grass Valley’s
environmental management system. Grass Valley believes this environmental information to be correct but cannot guarantee its
completeness or accuracy as it is based on data received from sources outside our company. All specifications are subject to
change without notice.
Registration, Evaluation Authorisation and Restriction of Chemicals (REACH)
Product may contain the following Substances of Very High Concern (SVHCs) above the threshold of
0.1% w/w per article.
CAS # Substance Name Where Used
110-71-4
1,2-dimethoxyethane; ethylene glycol
dimethyl ether (EGDME)
Battery
1303-86-2 Diboron trioxide Crystal
1317-36-8 Lead monoxide (lead oxide) Crystal
1317-36-8 Lead monoxide (lead oxide) Fan
110-71-4
1,2-dimethoxyethane; ethylene glycol
dimethyl ether (EGDME)
Integrated Circuit
117-81-7 Bis (2-ethylhexyl)phthalate (DEHP) Integrated Circuit
12060-00-3 Lead titanium trioxide Integrated Circuit
12626-81-2 Lead titanium zirconium oxide Integrated Circuit
12060-00-3 Lead titanium trioxide Power Supply
1303-86-2 Diboron trioxide Power Supply
1317-36-8 Lead monoxide (lead oxide) Power Supply

xiii
GV K-Frame X
Installation Planning Guide
Waste Electrical and Electronic Equipment (WEEE)
End-user must dispose of any Waste Electrical and Electronic Equipment (WEEE) separately.
Dispose equipment according to your local environmental laws and guidelines.
Battery Disposal
Your Grass Valley equipment usually comes with at least one button battery located on the main printed
circuit board. The batteries are used for backup and should not need to be replaced during the lifetime
of the equipment.
Before disposing of your Grass Valley equipment, please remove the battery pack as follows:
1. Make sure the AC adapter is unplugged from the power outlet.
2. Remove the protective cover from your equipment.
3. Gently remove the battery from its casing using a blunt instrument for leverage such as a
screwdriver if necessary.
4. Dispose of the battery and equipment according to your local environmental laws and
guidelines.
WARNING: Be careful not to short-circuit the batteries by adhering to the appropriate safe handling
practices. Do not dispose of batteries in a fire as they may explode. Batteries may explode if damaged
or overheated. Do not dismantle, open or shred batteries. In the event of a battery leak, do not allow
battery liquid to come in contact with skin or eyes. Seek medical help immediately in case of ingestion,
inhalation, skin or eye contact, or suspected exposure to the contents of an opened battery.
General Caveat
Grass Valley believes this environmental information to be correct but cannot guarantee its
completeness or accuracy since it is based on data received from sources outside our company. All
specifications are subject to change without notice.
If you have questions about Grass Valley environmental and social involvement (WEEE, RoHS, REACH,

xiv
Notices
Electromagnetic Compatibility
This equipment has been tested for verification of compliance with FCC Part 15,
Subpart B requirements for class A digital devices.
This equipment has been tested and found to comply with the requirements of
the EMC directive 2004/108/EC:
• EN 55022 Class A Radiated and conducted emissions
• EN 61000-3-2 Limits for harmonic current emissions
• EN 61000-3-3 Limitation of voltage fluctuations and flicker
• EN 61000-4-2 Electrostatic discharge immunity
• EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity
• EN 61000-4-4 Electrical fast transient immunity
• EN 61000-4-5 Surge transient immunity
• EN 61000-4-6 Conducted disturbances immunity
• EN 61000-4-8 Power frequency magnetic field immunity
• EN 61000-4-11 Voltage dips, short interruptions and voltage variations
immunity
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy, and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.

xv
Table of Contents
Electromagnetic Compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
1Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Grass Valley Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GV K-Frame X Standard Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Kayenne Control Surface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Flat or Curved Control Panel Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Control Panel Stripes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Touch Screen Menu Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Menu Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Basic Single Suite Kayenne Panel System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Multiple Suite Kayenne Panel System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Karrera Control Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Touch Screen Menu Panel Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Karrera K-Frame System Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
GV Korona Control Surface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Multiple Suites and Control Surfaces Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Soft Panel (KSP) Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Menu Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Supported Control Protocols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
2Frame Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
15-RU Video Processor Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
15RU Video Processor Installation and Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
15RU Video Processor Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Power Supply Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Power Supply Frame Rack Installation and Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Power Supply Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Power Supply AC Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Supplied Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
About High Line (208V-240V) Versus Low Line (120V) Operations . . . . . . . . . . . . . .23
About Low Line (120V) Operational Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . .24
3System Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
About the GV K-Frame X System Cabling Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
System Cabling Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Ethernet Tally Versus Serial Tally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

xvi
Table of Contents
Suites and Control Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Ethernet Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Customer Supplied Ethernet Routers and Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Factory Default Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
System Cabling for Kayenne Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Network Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Suites and Control Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Kayenne Control Panel Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Kayenne M/E and Local Aux Stripe Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Kayenne Satellite Panel Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Kayenne Touch Screen Menu Panels (Used with PCU). . . . . . . . . . . . . . . . . . . . . . . . . .32
Suites and Control Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Network Cabling for the Karrera Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Optional Touch Screen Menu Panel Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Optional Karrera Local Aux Panel Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Suites and Control Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
About GV K-Frame X Video Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
IP I/O Fiber Optic Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
SDI Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
IP I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Reference Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Supported Media Port Line and Frame Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
System Video Timing and Delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Timing Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Time Zones and the Autotiming Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
ClipStore Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
ClipStore Video Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Video Processor Frame GPI/Relay Tally Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
GPI and Relay Tally Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
GPI Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Relay Tally/GPI Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
GPI In, GPI Out, Relay Tally Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
RS-422/485 Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
RS-232 Port Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
GV K-Frame X Video Processor Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Appendix B Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Certifications and Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
FCC Emission Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Canadian EMC Notice of Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
EN55022 Class A Warning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Canadian Certified AC Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
FCC Emission Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
DEKRA Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

1
Introduction
Overview
The Grass Valley GV K-Frame X family of multi-format digital production switchers provide
powerful, groundbreaking features designed to meet the widest range of requirements for
live studio, mobile, and post-production applications.
The GV K-Frame X Video Processors are the heart of the system, providing extensive video
switching and signal processing capabilities.
Grass Valley Control Panels
The GV K-Frame X Video Processing Frame can be used with any Control Surface:
• Kayenne,
•Karrera,
•GVKorona,
• the Soft Panel (KSP option), and/or
• the Menu application running on a PC (Menu on PC).
In addition, the GV K-Frame X system supports direct control of external devices (DDRs,
Servers) and bi-directional control to and from routing and automation systems.
Features
General
• Fully digital 10-bit 4:2:2 video switcher including 4K, HDR (HLG and PQ), and1080p
support:
• SDI—1080p level-A or level-B
• IP I/O—1080p level-A
• The optional IP I/O board for the GV K-Frame X video processing engine offers Video-
Over-IP connectivity, using either uncompressed SMPTE 2022-6 or 4K 1-wire
compressed IP.
• 4K UHD processed using 2SI (2 Sample Interleave) or SDQS (Square Division Quad
Split).
• Integrated Macro Builder/Editor allows users to edit macros online or offline on a PC
running the menu application.
• Optional DoubleTake™ (split M/E mode) effectively increases the number of M/Es and
adds flexibility to Suites operation while FlexiKey™ programmable clean feed mode
supports separately programmable configurations of keyers from four M/E outputs.

2
Introduction
GV K-Frame X Standard Frame
• Aux bus transitions for dissolves and wipes on aux bus outputs.
• Interfaces with Grass Valley routers supporting Native Protocol.
• Optional Integrated 10 Channel Image Store capable of delivering up to 64 GB storage
of Stills (3,000 images) or “Movies” (up to 50 seconds) of 1080p video.
• LDK Series and LDX Series camera control with Ethernet tally via Connect Gateway.
• Optional integrated external ClipStore provides multiple channels of video/key pairs
for up to 10+ hours of nonvolatile video/key/audio clip content.
• 999 macros with many new to recall macros from the Control Panel.
• 1,000 E-MEM registers with Define E-MEM for fine control in creation and editing of
effects.
• Optional M/E Previewer provides a method to check and monitor any input to an M/E.
• VDCP Serial and Ethernet connection.
• Ethernet tally connection for integration with external tally systems.
• Optional RGB color correction on M/E buses and aux bus outputs.
• Source Rules:
• Links keyers to sources.
• Settings for On/Off/As Is on every M/E.
• Full look-ahead preview of rules.
• Hot-swappable, front/rear removable modules and power supplies.
• Optional multiple Multiviewer capability with 5 pre-configured layouts (maximum 14
panes per layout) with On-Air and Preview tally.
GV K-Frame X Standard Frame
• Up to 192 inputs and 96 outputs.
• Up to 9 M/Es, accessible across two suites—by using DoubleTake this may be increased
to 18 virtual M/Es.
• Every M/E has six keyers with standard keying modes including Chroma Key, two frame
stores per keyer—every keyer except for Controller M/E can use the pool of floating 3D
iDPMs.
• 2D-DPMs (resizers) on every keyer, with 6 Video/Key pairs per M/E so iDPMs can be
utilized for more complex effects.
• The Controller M/E has a complement of 6 full keyers with Chroma Key and 2D-DPMs.
• Up to 16 iDPMs (Integrated Digital Picture Manipulators), assigned as either floating
iDPMs or within an eDPM at user’s discretion.
Kayenne Control Surface
A Kayenne control surface typically consists of a Control Panel, a Menu Panel with an
included articulated support arm, a Panel Control Unit (PCU) frame, and optional Satellite
Panels. This control surface has an innovative modular design.

3
GV K-Frame X
Installation Planning Guide
Kayenne 4-M/E 35 Control Surface
Kayenne 3-M/E 35 Control Surface
Kayenne 2-M/E 25 Control Surface
Kayenne 1-M/E 15 Control Surface
The modular design and use of a separate PCU supports the hot-replacement of individual
Control Panel components, if necessary, while the rest of the system remains operational.
CAUTION: Do not connect or disconnect the PCU to Control Panel
cables while the system is powered on.
4-ME 35 Control Panel Menu Panel Menu Panel
Articulated
Arm
8623266_01
Panel Control Unit (PCU)
Optional Device
Control Module
Optional
Module
Menu Panel Menu Panel
Articulated
Arm
8623266_02
Panel Control Unit (PCU)
3-ME 35 Control Panel
Optional Device
Control Module
Menu Panel Menu Panel
Articulated
Arm
8623266_03
Panel Control Unit (PCU)
2-ME 25 Control Panel
Menu Panel Menu Panel
Articulated
Arm
8623266_04
Panel Control Unit (PCU)
1-ME 15 Control Panel

4
Introduction
Flat or Curved Control Panel Orientation
Flat or Curved Control Panel Orientation
The main Kayenne Control Panel supports different physical orientations. Besides a
conventional flat surface, a special support design permits a curved working surface, where
the M/Es progressively tilt for improved ergonomics.
Curved and Flat Control Surface Installations
Control Panel Stripes
The main Kayenne Control Panel is organized into from one to five Stripes. Each Stripe
consists of a tray and its complement of drop-in modules. An M/E Stripe has a module for
Source Selection, Transition, and individual E-MEM control. Additional Master E-MEM,
Machine Control, Multi-Function, and Local Aux modules are populated to complete the
control surface functionality.
Portion of Control Panel M/E Stripe
Touch Screen Menu Panel
Each Kayenne control surface includes a Menu Panel that features a wide format 15 in.
touch screen display. An articulated arm is also included, offering a wide variety of
installation options. The Menu Panel has a standard VESA-75 hole pattern and M4 threads,
compatible with this and many other mounting devices.
Flat Control Panel AssemblyCurved Control Panel Assembly
8623266_36
HoldHold
HoldHold A
HoldHold B
U1
U2
HoldHold
FarFarKeyKey
SplSplit
RulesRules
HoldHold EMEMEMEM
SecSec
Aux
Pri
KeyKey
3
KeyKey
1MacroMacro
KeyKey
5
KeyKey
4
KeyKey
2
RtrKeKey
6
EMEMEMEM
MaMacroro
RevRev
RwdRwd
RunRun
Transans
RateRate
Auto
Run
Run
Panelnel
MemMem
MeMenu
Mix Transns
PVW
Transans
Rate
EMEMEMEM
Runun
Ptntn
LimLimi t
Pst
BLK
KeyKey
1
KeyKey
2
KeyKey
3
KeyKey
4
KeyKey
5
KeyKey
6
KeKey 1
CutCut
KeKey 2
CutCut
KeKey 4
CutCut
KeKey 3
CutCut
KeKey 6
CutCut
KeKey 5
CutCut
KeKey1
Auto
Auto
KeKey2
Auto
Auto
KeKey3
Auto
Auto
KeKey4
Auto
Auto
KeKey6
Auto
Auto
CutCut AutoAuto
KeKey5
Auto
Auto
Userer
5Userer
6
Userer
4
Wipeipe
2
Wipeipe
1
Userer
3
Userer
2
Userer
1
Key
Prior
8623266_54
Source Module (35, 25, or 15) Local E-MEM ModuleTransition Module
Table of contents