2Mounting Note BAT-ANT-Protector m-f
Release
04
01/2017
General instructions
If exposed to extreme environmental conditions, especially icy conditions
or a polluted atmosphere, the connectors should be covered with a self-
vulcanizing tape or a cold shrink tube.
If the BAT-ANT-Protector m-f is mated with connectors made of copper-
alloy base material and trimetal or nickel plating the connector area must
be taped to improve long-term durability.
Disclaimer
All pertinent country, state, regional, and local safety regulations must be
observed when installing and using this product. For reasons of safety
and to help ensure compliance with documented system data, only the
manufacturer should perform repairs to components. This equipment
must only be installed and serviced by qualified personnel.
Device description
The BAT-ANT-Protector m-f is recommended for protecting the interior
electronics of BAT devices with outdoor antennas.
Despite outer over voltage protection measures, partial discharges can
still cause over voltages that can damage BAT devices. The BAT-ANT-
Protector m-f should be mounted as close as possible to the BAT device.
BAT-ANT-Protector m-f connectors
The BAT-ANT-Protector m-f provides two connectors, one for connecting
to the access point and one for connecting to the antenna (see fig. 1).
Figure 1: BAT-ANT-Protector m-f connectors
1 - N socket for connection to the antenna (unprotected end)
2 - N plug for connection to the access point (protected end marked in
red)