Ma ufacturer: Bircher Reglomat AG
Wiesengasse 20
CH-8222 Beringen
Switzerland
www.bircher-reglomat.com
info@bircher.com
Phone +41 (0)52 687 1111
Fax +41 (0)52 687 1112
4
Manufacturer: Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen declares that the
product, Typ: ProLoop2 11-pin
Model: ProLoop2 1.S.xxxxxx, ProLoop2 2.S.xxxxxx, ProLoop2 1.S.78.xxxxxx, ProLoop2 2.S.78.xxxxxx, 24AC C, 115AC, 230AC
Intended purpose: Programmable loop detector for controlling gates and barriers as well as for regulating and counting cars in parking areas
if used in accordance with the intended purpose, complies with the basic requirements acc. to:
R&TTE irective, Appendix III 1999/5/EC
9Declaratio of co formity
10 Co tact data
ProLoop2 11-pi
Supply voltage /
Current consumption /
Power consumption
24 VAC –20% to +10%, 84 mA, max. 1.8 VA
24 V C –10% to +20%, 84 mA, max. 1.3 W
115 VAC –15% to +10%, 30 mA, max. 3.5 VA
230 VAC –15% to +10%, 16 mA, max. 3.7 VA
Loop inductance max. 20 to 1000 µH,
ideally 80 to 300 µH
Loop connection wiring
At 20-40 µH: max. 100 m at 1.5 mm2
At >40 µH: max. 200 m with 1.5 mm2
min. twisted 20x/m
Loop resistance < 8 Ohm with connection wire
Output relay (loop) AC-1: max. 240 VAC; 2 A / C-1: max. 30 V C; 1 A
imensions 36 x 74 x 88 mm (W x H x )
Housing mounting Mounting rail installation via 11-pin base ES 12
Connection type Screw terminals base ES 12
Protection class IP 20
Approvals, safety See declaration of conformity at www.bircher-reglomat.com
Operating temperature –20°C to +60°C
Storage temperature –40°C to +70°C
Air humidity <95% non-condensing
Changeover to simulations mode Press «Sim1»
button
Press «Sim2»
button
Press «Sim2»
button
Press «Sim2»
button Anmerkungen
Changeover to simulation mode:
Press the Sim1 + Sim2 buttons
simultaneously for 2 seconds.
+
Simulation mode:
Activation of the loop
L0 -No loop activation (time functions are active)
L1 -Loop activation (time functions are active)
- Loop 1 - Loop 2
Activation of the output relay
00 - Activation of output
01 - Activation of output
- Loop 1 - Loop 2
Alarm output activation
A0 -Switch off alarm relay
A1 -Switch on alarm relay
Inductance of loop 1
Measurement of the inductance, value in µH
Inductance of loop 2
Measurement of the inductance, value in µH
Exiting simulation mode
Return to function mode
5Simulatio mode
If an error occurs, operating mode «A» and error display «E» light up alternately and an error code such as E 012 is displayed. The LE changes to
flashing red, the 4 most recent errors are stored and can be interrogated.
Display E001 E002 E011 E012 E101 E102 E201/E202 E301 E302 E311 E312
Error Interruption
Loop 1
Interruption
Loop 2
Short circuit
Loop 1
Short circuit
Loop 2
Under -
voltage
Over-
voltage
Saving
error
Loop 1
too large
Loop 2
too large
Loop 1
too small
Loop 2
too small
Briefly pressing the « ata» button shows the last of 4 errors on the display. Another short press switches to the error before that, and so on. When
the button is pressed for the 5th time, the device switches back to automatic mode. If you press the « ata» button for 4 seconds during the query,
all error messages are deleted. The figure shows memory slot 1 in which error 001, Interruption loop 1, has been stored (example).
6Troubleshooti g
7Reset
Reset 1 (recalibratio )
The loop(s) is/are recalibrated.
Mode
Sim1
8 Sekunden
Data
Sim2
Reset 2 (factory setti g)
All values (except the error memory) are reset to the factory
settings (see Table 4.11a). The loop(s) is/are recalibrated.
8Most importa t tech ical data
Danish seller: Swissdoor ApS
Stenhuggervej 2
DK-5471 Soendersoe
Danmark
Tel.: +45 86 28 00 00
www.swissdoor.dk