➔Installation, startup, modification and retrofitting of the system may only be carried out by an electrician.
➔Switch off the operating voltage before working on the system.
➔The control unit may only be used to protect against dangers at crushing and shearing points on automatic gates (designated use).
Any other use is prohibited.
➔It is recommended to change the batteries annually.
Radio transmission system for evaluation of safety edges. The system consists of a transmitter unit and a receiver unit.
2
Electrical connection
1
Transmitter Receiver
Transmitter
PCB Transmitter
Terminals
Battery1 CR2032
Battery 2 CR2032
LED (activation)
DIP - Switch
Push button
Antenna
Receiver
PCB Receiver
Terminals
LED 1 (system readiness)
Push button
DIP - Switch
LED 2
(Programming mode)
Buzzer
Antenna
Con iguration Receiver / Transmitter3
1. Transmitter: insert the enclosed batteries (type CR2032). Important: insert battery 1 first and then battery 2! Unless this order is observed,
correct function is not guaranteed. The batteries must be suitable for use at temperatures of -20°C and above.
2. Connect receiver to supply voltage. (Note correct polarity for DC.)
The system has no fuse protection. It is advisable to include a fuse protection of minimum 100mA and maximum 250mA into the external power.
3. Configuration Receiver / Transmitter (➔chapter 3)
4. Carry out programming (➔chapter 4).
At startup, a minimum distance of 1m must be observed between the transmitter and receiver.
Safety edges
Transmitter inputs Receiver Output*
(power off state) Test Remarks
0 V
+ 12 / 24 V
Test
CBS
Output*
1234567
We recommend:
1. Use a cable with a diameter
between 3,5 – 7,0 mm.
2. Use a cable with 6 cores
(from 0,25 mm2to 0,5 mm2).
Receiver functions Setting DIP-Switch Description
Power consumption:
“On”
Standard setting for safety operation
“Off”
Lover power consumption of transmitter ➔For storage only! Not for safety operation!
Transmitting frequency
Frequency 1
Setting MUST match that of transmitter, Frequency 869,85 MHz
(if frequency 2 is disrupted externally)
Frequency 2
Setting MUST match that of transmitter, Frequency 868,95 MHz,
Test input
NC
Test contact NC, activated = contact open (npn transistor off)
NO
Test contact NO, activated = contact closed (npn transistor on)
Automatic
frequency adjustment
“On”
Automatic frequency adjustment switched on (only at very strong disrupted surroundings)
“Off”
Automatic frequency adjustment switched off
*
*
*
*
*Factory settings
Standard:
with current control:
7
6
7
6
npn
open
collector
potentional free contact
or
Transmitter Receiver (Outputs / LEDs)
Safety edge Limit switch LED Out ut C-S Out ut C-B LED 1 LED 2
not actuated open OFF closed 8k2 ON OFF
actuated open flashes open closed OFF OFF
not actuated closed OFF closed 8k2 ON OFF
actuated closed flashes closed 8k2 ON OFF
Signal status (DIP-Switch at factory settings)