INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Bisolid GP xx_B hc> . OM-BSGPHCV02/07/2017/EN12
Switch on or off the pellet burner. It is recommended to do it by the key Start, located
on the boiler’s control panel.
Check the pellet burner condition.
After initializing the pellet burner into operation the servicing technician is obligated to
introduce the user with the operation and maintenance of the appliance. Attendance of
children without supervision near the pellet burner is not allowed. Any interventions or
activities over the burner construction that may endanger the life or health of the handling or
attending personal are strictly forbidden.
Usage of flammable liquids for easier firing as well as any activities related to increase of the
pellet burner’s nominal heating output (overloading) are strictly forbidden. Positioning of
flammable objects near the burner is also not allowed.
In case of danger from penetration of flammable vapors or gasses in the boiler
room or any activities that may lead to fire or explosion (gluing the flooring,
varnishing with flammable paints or others), the pellet burner must be led out of
operation before starting any of these activities.
3.2. SAFE OPERATION OF THE PELLET BURNER
All safety prescriptions must be observed when the pellet burner series Bisolid GP xx_B hc> is
operating. The pellet burner must not be used for any other purposes except the ones
introduced in this operation manual.
The surface of the pellet burner should be cleaned only with standard inflammable cleaners.
Positioning of objects made of flammable materials over or near the pellet burner, at shorter
than the safe distance is not allowed.
It is not allowed to store flammable materials (wood, paper, oil and other flammables) in the
same room, where the pellet burner and the boiler are situated.
The recommended safe distance between the boiler, with installed pellet burner series Bisolid
GP xx_B hc>, and the fuel must be minimum 1000 mm.
The minimum allowed distance between the pellet burner’s outer parts and easy or medium
flammable materials, also including fuel, must be at least 400 mm.
Removal of the ash remainings from the burner should be performed by taking out the
combustion chamber fire-grate. The fire-grate, where the ash deposits gather, must be
emptied on time, before its complete filling. All activities related to removal of the ash from the
pellet burner should be performed after cooling of the fire-grate, as the usage of metal pliers is
strongly suggested. Please also use protection gloves as a safety measure.
When installing the pellet burner and the elements for safety and control please
do not forget that all installation works must comply with the safety labor
principles. If a pellet burner or fuel transport auger component replacement is
necessary, please use the recommended elements. In case of using any other
type of component you should ask the manufacturer company first. The pellet
burner and fuel transport auger functionallity must be checked by authorized
servicing specialist once per year.