BluWater Technology Genesis Blu Fusion User manual


Genesis BLU FUSION User Manual
Never your spanon-chlorine !
Never use C or cyanuric in your spa!
Never enter a spa when bromine is NOT present!
Children should always be supervised around your spa!
Always cover your spa when not in use!
1. WARNINGS .......................................................................... 3
2. G SYSTEM COMPONENTS.................... 4
3. INSTALLATION INSTRUCTIONS ............................................ 5
4. HOW DOES MY WORK .......................................... 6
5. START-UP/OPERATING INSTRUCTIONS ............................... 7
6. MAINTENANCE AND OPERATION…............................……….8
7. HOW AND WHEN TO ADD SODIUM BROMIDE……….. ....... 10
8. UNDERSTANDING YOUR CONTROLLER ............................. 11
9. CHECKING FOR CONDUCTIVITY ........................................ 12
10. QUICK REFERENCE DOS AND DON’TS ............................... 12
11. APPENDIX I: GLOSSARY ...................................................... 13
12. APPENDIX II: SPA WATER MANAGEMENT ........................ 14
13. QUICK TROUBLESHOOTING YOUR BROMINE ................... 14
14. PHOSPHATE TEST……………………………………………………………16

Genesis BLU FUSION Use nul
3
WARNINGS:
When using this electrical equipment, basic safety precautions should always be followed, including the
following:
BEFORE CONNECTING YOUR SYSTEM READ AND FOLLOW ALL INSTRUCTIONS
Genesis must be connected to a circuit protected by a ground fault circuit
interrupter (GFCI) in the US. In Canada, the appliance be connected through a residual
current device (RCD) that has a rated residual operating current not exceeding 30 mA.
A terminal marked Earth/Ground, or the is located inside the supply terminal box or
compartment.
To reduce the risk of electric shock, this terminal must be connected to the grounding means
provided in the electric supply service panel with a continuous copper wire equivalent in size to
the circuit conductors supplying this equipment.
parts, except parts supplied lowvoltage not exceeding 12volts, must beinaccessible
to a person in the spa
Earth/Ground appliances must be permanently connected to fixed wiring.
Parts incorporating electrical components, except remote control devices, must be located or
fixed so that they cannot fall into the bath.
Genesis shall be attached with screws. Make sure that the screws do not contact
internal circuitry. Make sure that the screws do not allow the ingress of liquid.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or
similarly qualified persons in order to avoid a hazard.
In the US, Genesis must only be used with Sodium Bromide registered with the EPA. In
Canada, the Sodium Bromide must be scheduled or registered under the Pest Control Product Act.
Always clean and/or replace your filter at least once every
Your Genesis unit should be installed after the heater in the circulation pump line.
WARNING – To reduce the risk of injury, do not permit children to use this product unless they
are closely supervised at all times.
System is for outdoor use only

3
3
SC

Genesis
INSTALLATION INSTRUCTIONS
NEVER Horizontal
ALWAYS Vertical
• Electrode must be installed VERTICALLY!
ELECTRICAL:
PLUMBING:
MUST NEVER
½
5

Genesis
How does my Genesis BLU FUSION Unit Work?
are
t
6


Genesis BLU FUSION User Manual
Genesis BLU FUSION Maintenance and Operation
WATER CHEMISTRY
pH, Alkalinity and Bromine levels are in the proper range.
HOW MANY HOURS A DAV SHOULD MY LOW SPEED PUMP CIRCULATE?
Circulation time is a very important element
f
or clean and inviting
w
ater. Eight (8) hours is the minimum
circulation time needed
f
or Genesis BLU FUSION to create the proper amount o
f
b
romine
f
or your
spa. Your system should only
b
e po
w
ered on and producing Bromine
w
hen your spa is circulating. It is
recommended to use a
24-
hour circulation pump
f
or spas over
1
,
000
US Gallons.
FINDING THE RIGHT POWER SETTING
8

Genesis BLU FUSION User Manual
CLEANING THE SPAS FILTERS
IMPORTANT POINTS TO REMEMBER
before
V
NEVER USE CHLORINE OF
ANY KIND IN A SPA OR HOT TUB.
Remove the
phosphates by thoroughly cleaning the filter.
9

Genesis BLU FUSION User Manual
How and when to add Genesis TRU BLU Salt (NaBr
Sodium Bromide):
Y
Y
WA
Use a BROMINE TEST KIT to test bromine levels re
g
ularly!
Bromine s
h
oul
d
be maintaine
d
bet
w
een
3-5PP
M
10

Genesis
Intelligent Controller Codes r BLU FUSION Automated Bromine Generator
g(Boost)
accumulated eight
hours of pump circulation
time.
E
a
11

Genesis BLU FUSION User Manual
n
4
24
/2
Dos
Don'ts
non-chlorine
12


Genesis BLU FUSION Use nul
14
Appendix II: Spa Water Management Spreadsheet
When you first install your Spa, it is very important to understand your water chemistry. Use this tool to track your
water. Your spa dealer can test your water and provide the information. You can also conduct your own tests using
proper testing equipment.
Week 1
Week 2
Week 3
Week 4
Week 5
Week 6
Week 7
Week 8
90 Days
pH:
Total
Alkalinity:
Calcium
Hardness:
Phosphates:
Week 1
Week 2
Week 3
Week 4
Week 5
Week 6
Week 7
Week 8
90 Days
pH:
Total
Alkalinity:
Calcium
Hardness:
Phosphates:
How many hours is the spa circulating? (Minimum of 8 hours)
What is the Genesis NaBr)level? (1300-1500 PPM)?
900
)
Water source? (""""?)
()
()

Genesis BLU FUSION Use nul
15
WARRANTY INFORMATION CARD
BEFORE SUBMITTING ANY CLAIM, CONTACT YOUR SPA DEALER WITH QUESTIONS IN ORDER TO ENSURE YOU
HAVE COMPLETED APPROPRIATE TROUBLESHOOTING STEPS FOR YOUR UNIT.
Dealer
where purchased:
Contact:
Telephone:
Date of
purchase:
Spa
Brand:
S install: Pre-Installed After Market
Start up Water
Chemistry:
pH:
Were you provided bromine test strips?
Yes
No
Total Alkalinity:
Were you provided Tru Blu test strips?
Yes
No
TDS:
Did you fill your spa with municipal or well water? Well City
Calcium Hardness:
Comments:
Metals:
Phosphates:
Questions? Contact you Dealer.
You may also contact Tech support at 1 8 or visit us online at www.m
For all warranty issues, concerns, or claims, make certain that this form is complete in its entirety and submitted
with your system.

0 PPB � � GOOD!
200 PPB 0� HIGH
500 PPB � HIGH
Hot Tub Solutions DBA
BluWater Technology, Inc.
BluTech®
P .0. Box 2315
Humble, TX 77347
www.bluwatertechnology.com
Toll Free: 855-447-8772
Table of contents
Popular Portable Generator manuals by other brands

Daewoo
Daewoo GDA 3500 manual

Krüger Technology
Krüger Technology KGVC4000 instruction manual

Baumer
Baumer GT 7 Mounting and operating instructions

Champion Global Power Equipment
Champion Global Power Equipment 100455 Operator's manual

Forbes
Forbes DiWa-2500 user manual

Power X Generators
Power X Generators 3000 Owner's manual & operating instructions

Buffalo Tools
Buffalo Tools SPORTSMAN GEN4000TRI instruction manual

Hyundai power products
Hyundai power products HY3100L user manual

FAR
FAR GGC 950 Original manual translation

MULTIQUIP
MULTIQUIP Power WHISPERWATT DCA-100SSVU Operation and parts manual

Gopel Electronic
Gopel Electronic basicCON 4115 user manual

Chicago Electric
Chicago Electric 96898 Set up and operating instructions