Bosch RF835E Series User manual

© 2012 Bosch Security Systems, Inc. F01U254570 | 03 | 2012.11 | 1
Installation. Gently insert a flat-
bladed screwdriver into notch for
the section you wish to remove, and
then lift on the section to unhinge.
NOTICE:
Do not twist. NOTICE:
The mounting height must be 2 m (6.5 ft) and the vertical
angle must be set at -5° for installations containing pets.
Mounting
Height
Range
6.1 m (20 ft) 10.7 m (35 ft)
2 m (6.5 ft) - 7 ° - 5 °
7.0 ft (2.1 m) - 9 ° - 6 °
8.0 ft (2.4 m) - 10 ° - 7 °
Height and Adjustment
Loosen the Vertical Adjust Screw. Adjust the board to the desired angle.
Choose mounting height and desired range and set the vertical angle.
INT
STD
Vertical
Adjust
Screw
- 6
- 10
- 6
- 10
MW
MIN
MAX
For pet immune
applications, adjust
the angle to -5.0.
INT
STD
INT
STD
PIR Sensitivity Selection Pins
Set the PIR Senstivity Vertical adjusing
screw must be securely tightened after
setting the angle.
123
Specifications
General
• Dimensions (HxWxD): 13.9 cm x 7.2 cm x 6.9 cm (5.4 in x 2.8 in x 2.7 in)
• Power supplied by four 1.5V AA Alkaline Batteries. Recommended Batteries:
Panasonic AM-3,Duracell MN1500, or PC1500 Energizer E91.
• Typical current draw is 100 μA with the LED disabled. The LED is automatically
disabled except during walk tests.
• Typical battery life is two to three years.
• Operating temperature range of 0°C to +49°C (+32°F to +120°F).
• Relative humidity range of 0% to 95% (non-condensing).
• Microwave Frequency: RF835E is 10.525 GHz, RF835E-C is 10.588 GHz
• RF Transmit Frequency: 433.0 MHz.
TriTech Motion Sensor
• Coverage area 10.7 m by 10.7 m (35 ft by 35 ft).
• Internal coverage pointability -4° to -10° Vertical.
• Field selectable sensitivity options of Standard and
the more sensitive setting of Intermediate.
• Three minute transmitter lockout time after alarm
extends battery life.
• Timed Walk Test Mode automatically disables LED
after setup to extend battery life.
• Cover activated Tamper indication. Optional wall-acti-
vated Tamper is included.
RF Transmitter
• Integral RF transmitter capable of transmitting 150
m (500 ft) in open air. (Actual acceptable transmit-
ter range should be verified for each installation). In
normal operation, it is recommended that the RF835 be
within 30 m (100 ft) of the receiver.
• Transmits low battery reports and tamper reports to the
control panel.
• Transmits supervisory signal to the control panel every
13 minutes.
2.0 m - 2.4 m
(6.5 ft - 8 ft)
Recommended:
2,2 m (7.5 ft)
Pet Friendly
1 dog ≤ 45 kg (100 lb),
2 dogs ≤ 27 kg (60 lb),
or up to 10 cats
Mount the detector
2 m (6.5 ft) above the floor.
Do not point where
pets can climb.
The upper areas are
not pet immune.
Receiver
1
Receiver Range: 150 m (500 ft)
Recommended: 30 m (100 ft)
6.5 ft.
(2 m)
RF835E Series Wireless
TriTech PIR/Microwave
Intrusion Detector with
Pet Immunity
en Installation Guide
Optional Bracket:
B328, B335, B338, B800
Batteries must not be disposed of in household
waste. Dispose batteries at suitable collection
points. For further information refer to
http://boschsecurity.com/standards.
Notice:
Product must be installed in accordance with
NFPA70, Local Authorities Having Jurisdiction
(AHJ’s) and all local codes.

© 2012 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 F01U254570| 03 | 2012.11 | 2
Countries of Intended Use:
These poducts are intended for use in
the following countries within the Euro-
pean Union and in countries outside the
European Union:
RF835E Austria, Belgium, Denmark, Fin-
land, Greece, Luxembourg, Netherlands,
Norway, Spain, and Sweden.
RF835E-C United Kingdom, Ireland, and
France.
Uncover the Look Down Lens
NOTICE:
In non-pet applications only, If look-down
is desired, peel away the look-down mask.
Do not remove the clear plastic lens.
Mount the Detector Base
NOTICE:
The Wall Tamper cannot be used in
corner mount installations or when
using the swivel bracket.
The batteries are not installed in
the detector when it is shipped.
When installing the batteries it is
necessary to observe proper polar-
ity or the sensor may not function.
LED Condition Cause
Steady Red Unit Alarm
Steady Yellow Microwave
Activation
(Walk Test)
Steady Green PIR Activation
(Walk Test)
Flashing Red Warm-Up Period
After Power-Up
Flashing Red
(four-pulse
sequence)
Microwave or PIR
Failure
Replace Unit
If the Wall Tamper is desired, gently
press the spring onto the tapered shaft.
Do not force it down onto the shaft. As
you place the unit onto its base, be sure
the spring extends through the knock-out
to the wall.
When the batteries are installed, wait at
least 5 min before activating the Walk
Test Mode. The LED will stop flashing
when the detector is ready to test (the
sensor requires “lack of motion” to stabi-
lize on startup). Refer to LED Conditions
chart.
LED Conditions
Install the Battery
+++++
+
+
+
--
-
-
---
-
Walk test the detector.
Perform this test at the time of installation and monthly thereafter. To ensure contin-
ual daily operation, the end user should be instructed to walk through the far end of
the coverage pattern. This ensures an alarm output prior to arming the system.
Remove and replace the cover to start a 90-sec Walk Test Mode.
During this Test Mode, any activity in the sensor’s coverage pattern will cause a trans-
mitted alarm and LED activation. Each alarm will also extend the Test Mode.
Watch for the yellow LED to indicate the edges of the Microwave pattern. Adjust as
necessary.
Green =
PIR detect
Yellow =
MW detect
Red =
Alarm
INT
STD
MIN
MAX
Set the adjustment
as low as possible
for proper catch
performance
MIN
MAX
Program the control panel.
There is a two-part ID sticker lo-
cated on the
housing of the RF835E. You will
need the number on this sticker to
program the Detector into the
control panel. Refer to your panel’s
Programming Guide for program-
ming information on wireless type
devices.
ID Number
167770187
167770187
NOTICE:
Insert security screws after testing to
prevent covers from separating.
NOTICE:
The protective zone
is the area where the
PIR and Microwave
technologies overlap.
NOTICE:
Masking only
eliminates the PIR
portion of the
coverage and has no
effect on the
Microwave pattern.
Coverage Patterns
Masking Lens
Remove
masking for
Look-Down LZ W-X R-U, Z N-Q
B-L
0 m 2 m 10 m8 m
6 m
4 m 11 m
7.8 ft
7 ft
0 ft
0 ft 35 ft33 ft
26 ft
20 ft
13 ft
7 ft
2.4 m
2 m
0 m
Top View
45 6
78
Reading Bosch Security Systems, Inc.
Product Date Codes
For Product Date Code information, refer to the
Bosch Security Systems, Inc. Web site at:
http://www.boschsecurity.com/datecodes/.
Other Bosch Carbon Monoxide Alarm manuals
Popular Carbon Monoxide Alarm manuals by other brands

Firex
Firex COQ3 owner's manual

First Alert
First Alert co614 user manual

Shenzhen Yongchangda Electronics
Shenzhen Yongchangda Electronics OJB-CR701-YZ quick start guide

System Sensor
System Sensor CO1224T Installation and maintenance instructions

Defender
Defender CA6150 quick start guide

BRK electronic
BRK electronic CO250RVA-48B user manual