Brave BRI4100IER User manual

ITEM NUMBER
SERIAL NUMBER
Model BRI4100IER
Please read this manual carefully before operating your new inverter generator.
50 State and CSA Certied
Operating Instructions
& Owner’s Manual

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
2BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
2
Operating Instructions
& Owner’s Manual
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
BRI4100IER
PLEASE KEEP AND READ THIS MANUAL
CAREFULLY BEFORE OPERATING YOUR NEW
BRAVE DIGITAL INVERTER
GENERATOR
RECORD PURCHASE HERE
MODEL # __________________________
ENGINE ID # _______________________
DATE OF PURCHASE _______________
PURCHASE LOCATION _____________
50 STATE AND
CSA CERTIFIED
ENGINE ID # IS STAMPED
ON CRANK CASE

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 3
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 3
Operating Instructions
& Owner’s Manual
ATTENTION:
Rental Companies and Private Owners
who loan this equipment to others!
All persons to whom you rent/loan this inverter generator must have
access to and read this manual. Keep this owner’s manual with the inverter
generator at all times and advise all persons who will operate the machine
to read it. You must also provide personal instruction on how to safely
set-up and operate the inverter generator and remain available to answer
any questions a renter/borrower might have.
Only Trained Adults should set up and operate this equipment.
DO NOT LET CHILDREN OPERATE THIS EQUIPMENT!
Always wear safety apparel when operating this equipment,
safety glasses, ear protection, insulated waterproof gloves, and non-slip
protective shoes are recommended. When using any cleaning chemicals
refer to the chemical label for safety instructions concerning those chemicals
for use of a respiration mask.
Never operate or let anyone operate this equipment while under the
inuence of any alcohol, drugs, medication or when fatigued.
Owner’s Manuals are available on our website at
www.braveproducts.com

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
4BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
4
Operating Instructions
& Owner’s Manual
SPECIAL HAZARDS
• CO Poisoning: Exhaust from engine contains carbon monoxide, a poisonous gas that can
cause carbon monoxide poisoning and possible death if inhaled.
• Injection Injury: High-pressure spray can pierce skin and underlying tissues, leading
to serious injury and possible amputation. Such an injection injury can result in blood
poisoning and/or severe tissue damage.
• Flying Debris: High-pressure spray can cause ying debris and possible surface damage.
• Electric shock: Operating equipment in wet conditions or near water can cause electric
shock.
• Chemical Exposure: Cleaning chemical vapors or contact with skin may be hazardous.
• Fire/Explosion: Engine sparking can ignite fuel or other ammable liquids or vapors in the
vicinity. Hot exhaust from engine can ignite combustible materials.
• Burns: Inverter Generator pump & engine are hot surfaces that can cause burn injuries.
EQUIPMENT PROTECTION FACTS
Inspect Upon Delivery:
FIRST! Inspect for missing or damaged components. See “Initial Set-Up/
Installation” section for where to report missing or damaged parts.
Add Engine Oil:
Engine is shipped without oil. See the “Engine Manual” section of this
manual for instructions on capacity and viscosity recommendations.
Maintenance Schedule:
Engine requires periodic inspection and servicing to keep generator
functioning efciently. See “Maintenance Schedule Summary” for frequency
of servicing.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 5
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 5
Operating Instructions
& Owner’s Manual
TABLE OF CONTENTS
Preface . . . . . . . . . . . . .
6Maintenance . . . . . . . . . . . . . . . . . . . . 31
Product Specications . . . . . . . . . . . 7Transporting The Unit . . . . . . . . . . . . . . 36
Safety Instructions . . . . . . . . . . . 8Long-Term Storage . . . . . . . . . . . . . . . . . . . 36
Automotive Type Electronic Fuel Injection System 11 Short-Term Storage . . . . . . . . . . . . . . . . . . . 37
Controls and Features . . . . . . . . . . . 12 Exercising The Generator . . . . . . . . . . . . . . . . . 38
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 38
PRE-OPERATING INSTRUCTIONS AC Application . . . . . . . . . . . . . . . 39
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Low Oil Alert System . . . . . . . . . . . . . . . 39
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Powering 12V DC Devices . . . . . . . . . . . . . . . 40
Understanding Your Battery . . . . . . . . . . . . . . 22 Jump-Starting The Generator . . . . . . . . . . . . . 41
Battery Assembly & Maintenance . . . . . . . . . . 23 Digital Display . . . . . . . . . . . . . . . . . . . . . . . . 42
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Error & Fault Codes . . . . . . . . . . . . . . . . . . . . . 43
Starting Your Generator . . . . . . . . . . . . . . . . . . 26 Wattage Chart . . . . . . . . . . . . . . 44
Limited Warranty Policy . . . . . . . . . . . . . . . 48
Operation of Generator . . . . . . . . . . . . . 27 Exploded View / Parts List . . . . . . . 52
Storing The Unit . . . . . . . . . . . . . . 30 Wiring Diagram . . . . . . . . . . . . . . . 58
PLEASE READ THE
FOLLOWING INSTRUCTIONS!
1. Unit Shipped without engine oil. See Pre-operating Instructions for further
information.
2. For repair under Warranty or questions concerning Warranty, DO
NOT RETURN this product to the Store where purchased. Follow the
procedures as outlined in the “WARRANTY POLICY” and “WARRANTY
REGISTRATION” in the Owner’s Manual. For any questions call
1-888-980-4938, Option 2 (Warranty and Service).
3. Read the “Owner’s Manual” prior to operating any equipment and
familiarize yourself with the Proper and safe operation of the equipment.
If you have any questions, or call 1-888-980-4938, Option 2 (Warranty
and Service).

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
6BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
6
Operating Instructions
& Owner’s Manual
PREFACE
Thank you for choosing BRAVE for your Power Equipment needs. BRAVE prides itself
on providing quality products at affordable pricing, creating the “Best Equipment Value
on Today’s Market!”
Your Digital Inverter Generator utilizes our Industrial Grade Gasoline Engines and is
intended for OUTDOOR USE ONLY.
All BRAVE products are manufactured utilizing the latest technology. Built with quality
components, your new Power Equipment Product will give you years of dependable
service. Your unit, along with all of BRAVE products are designed, engineered, and
manufactured with an Industrial Grade Gasoline Engine.
This Owner’s Manual will provide you with all of your needed information for your new
Power Equipment Product, including Safe Operation and Maintenance of your unit.
Please keep and read this Owner’s Manual completely and carefully prior to operation.
Keep this Owner’s Manual for assistance in the future, such as proper maintenance
schedules and tips to prolong the life and effective use of your unit. If you require
assistance, call toll free 1-888-980-4938 Option 2, Warranty and Service.
This Owner’s Manual contains information with respect to the newest products at the
time of publication. Due to revision and modications, the information noted in the
Owner’s Manual might vary from the actual status. This Owner’s Manual is subject to
change without notice. The copyright of the Owner’s Manual belongs to BRAVE. Any
group or individual is forbidden to reprint or copy any of this Owner’s Manual without
the written consent of BRAVE.
FOR ALL WARRANTY AND SERVICE RELATED ISSUES/QUESTIONS DO NOT
RETURN YOUR UNIT TO THE STORE OR DEALER WHERE THE ITEM WAS
PURCHASED. FOR SERVICE CALL 1-888-980-4938 Option 2, Warranty and Service.
WE WILL BE HAPPY TO HANDLE YOUR WARRANTY ISSUE OR DIRECT YOU TO
THE NEAREST “AUTHORIZED SERVICE CENTER.”

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 7
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 7
Operating Instructions
& Owner’s Manual
POWERED
BY
Voltage 120V AC & 12V DC
AC Surge Output1 4100 watts
Rated AC Output2 3800 watts
Maximum AC Amperage 30 amps
AC Cycle 60Hz
12V 8.3amp DC Receptacle 1 ea. (T-type)
120V 20a AC Receptacles 2 ea. with ground
120V 30a RV Receptacles 1 ea.
120V 30a 3-Prong Twist Lock 1 ea.
Sine Wave Distortion 2% or Less
Auto Idle Feature Power On Demand
AC Overload Yes
Exhaust Spark Arrestor3 Yes
Parallel “Duo-Power” Ready N/A
ENGINE
Manufacturer FME
Model 177
Engine Displacement 270cc
Starting System Remote Recoil / Electric
Remote Start Yes
Fuel Tank Capacity 3 1/2 gallons
Fuel Gauge Yes
Run Time (@ 50% load) 4 hours
Sound Level (@ 7m / 23ft.) 57db
Engine Type 4-Stroke OHV
Fuel Type (Automotive Grade) Unleaded Gasoline
Fuel Compliance 10% Ethanol Mix or less
Oil Type & Amount SAE 10W30 32 oz.
Low Oil Shutoff Protection Yes
CARB Certied 50 State & Canada Compliant
UNIT DIMENSIONS
Length x Width x Height 23.5 in. x 18.5 in. x 20.5 in.
Weight (Lbs.) 112.5 Lbs.
ACCESSORIES
Battery Charger/Maintainer Included
12V Cord, Plug & Clips 1 ea.
Mobility / Wheel Kit 4 Lock Down Caster
PRODUCT SPECIFICATIONS

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
8BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
8
Operating Instructions
& Owner’s Manual
BRAVE

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 9
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 9
Operating Instructions
& Owner’s Manual
ONLY operate generators outdoors.
Exhaust gas must be prevented from
entering conned areas.
Direct exhaust gas away from
windows, doors, ventilation, and
other openings.
Do not operate this generator inside
or under any buildings.
WHEN ADDING OR DRAINING FUEL
• Turn inverter generator off and let it cool for at least three minutes before removing fuel cap. Loosen
cap slowly in order to relieve pressure in the fuel tank.
• Fill or drain fuel tank outdoors. Do not excessively inhale fuel vapors.
• Keep away from open ames or sparks and other sources of ignition.
• Do NOT smoke while lling fuel tank.
• Do NOT overll tank. Allow space for fuel expansion.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
• Transport inverter generator with the fuel valve in the off position.
• Repair inverter generator with the fuel tank empty or the fuel valve in the off position.
• Disconnect spark plug wire before transport or service.
WHEN STORING FUEL OR EQUIPMENT CONTAINING FUEL
• Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot
light or other ignition source because they can ignite fuel vapors.
WHEN STARTING EQUIPMENT
• Ensure spark plug, mufer, air cleaner, and fuel cap are in place.
• Do NOT crank engine with spark plug removed.
• If fuels spills, wait until it evaporates before starting engine.
WHEN OPERATING EQUIPMENT
• Do NOT choke carburetor to stop engine.
• Do NOT tip engine or equipment at an angle, which causes fuel to spill.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
10 BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
10
Operating Instructions
& Owner’s Manual
CAUTION!
Improper use and care of this inverter generator will cause damage and shorten
its lifespan. Failure to follow these actions will void all warranties.
• Use inverter generator only for appropriate and designated purposes.
• The dealer or customer helpline (1-888-980-4938) can instruct you on intended
uses.
• Inverter generator must be placed on a level surface.
• Do NOT expose inverter generator to extreme conditions. Excessive dust, moisture,
and corrosive vapors will damage unit.
• Engine cooling slots must be kept clear of debris.
• Shut off inverter generator and take to a qualied service center if the unit fails to
operate properly.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 11
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 11
Operating Instructions
& Owner’s Manual
Automotive Type Electronic
Fuel Injection System
This generator has a computer-controlled fuel and ignition system. An on-board
computer, referred to in this manual as an ECU (Engine Control Unit) utilizes a
series of virtual maps (lookup tables) that provide values for various aspects of
engine performance. The ECU analyzes data provided through the various
engine sensors to determine the best combination of values from these lookup
tables to provide optimum performance. This is communicated to the generator
components through the use of digital signals. This is in contrast to non-
computer-controlled ignition systems that rely on mechanical feedback, and
sometimes vacuum, to control the motion of the various components.
This generator is equipped with an Electronic Fuel Injection (EFI) system, which
provides increased efciency over carbureted fuel systems. In a carbureted fuel
system, the fuel and air are mixed in a carburetor that relies on a mechanical choke
system controlling the rate of air intake to maintain the vacuum necessary to mix the
fuel with air for combustion.
In a fuel injection system, the ECU calculates and adjusts the fuel mixture
directly, based on real-time feedback, allowing for greater fuel and emissions
efciency. The ECU also controls the timing for the spark plug, dynamically
controlling the speed of the engine depending on requirements for power
generation.
When there is a problem reported by a generator component (such as an engine
sensor), the ECU stores a fault code for it. These fault codes can be read in the
Wattage (P) eld of the digital display, and then used to identify the issue and
correct it. For more information on fault codes and how to access them, refer to the
Fault codes section of this manual. For more information on the digital
display and its use, refer to the Digital display section of this manual.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
12 BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
12
Operating Instructions
& Owner’s Manual
CONTROLS AND FEATURES
FUEL CAP
FOLDING HANDLE
LOCKING CASTER
WHEELS
CONTROL
PANEL

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 13
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 13
Operating Instructions
& Owner’s Manual
LOCKING CASTER
WHEELS
EXHAUST PORT
CONTROLS AND FEATURES
FUEL LEVEL METER FUEL CAP
CONTROL
PANEL RECOIL
STARTER
LOCKING CASTER
WHEELS

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
14 BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
14
Operating Instructions
& Owner’s Manual
CONTROLS AND FEATURES
LOCKING CASTER
WHEELS
RECOIL
STARTER
HANDLE
FOLDING HANDLE
OIL FILL
ACCESS

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 15
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 15
Operating Instructions
& Owner’s Manual
CONTROLS AND FEATURES
LOCKING CASTER
WHEELS
FOLDING HANDLE
ACCESS PANEL
(remove for maintenance of air cleaner
element, spark plug, valve adjustment,
etc.)

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
16 BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
16
Operating Instructions
& Owner’s Manual
CONTROLS AND FEATURES
120V AC RECEPTACLES
DC SOCKET
STATUS DISPLAY
NEUTRAL
GROUND
TERMINAL
BOX CONTENTS
• Generator
• Accessory Kit
(1) Spark Plug Removal Tool
(1) Oil Drain Tube
(1) 12 Volt Power Cord with Plug & Alligator Clips
(1) NEMA14-30 Male Twist Lock Plug
(1) RV Adapter Plug for 120 Volt 30 amp Service
(1) Owner’s Manual & Warranty Card

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 17
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 17
Operating Instructions
& Owner’s Manual
PRE-OPERATING
INSTRUCTIONS: ASSEMBLY
3-PRONG
NEMA MALE
TWIST-LOCK
PLUG
ALLIGATOR CLIPS 12V DC
2 PC.
SCREWDRIVER
SPARK PLUG
WRENCH
OIL DRAIN
TUBE
EXTENSION
REMOTE START
KEY FOBS
BATTERY CHARGER
SPARK
PLUG
FUSE
Your BRAVE Generator is packaged without fuel and oil. Some assembly is required before operating
your BRAVE Generator.
For further assistance in assembling your generator, please call 1-888-980-4938 between the hours
of 9am-5pm Monday-Friday.
UNPACKING THE GENERATOR:
1. Set the Carton on a Flat, Rigid Surface.
2. Remove All Contents from Carton EXCEPT Inverter Generator.
3. Open Box Completely by lifting box cover.
4. Carefully lift the Inverter Generator off the remaining box and onto the Flat, Rigid Surface.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
18 BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
18
Operating Instructions
& Owner’s Manual
PRE-OPERATING
INSTRUCTIONS: SETUP
CAUTION: Any attempt to start the generator before it has been properly serviced may result
in engine failure and void warranty.
ADD ENGINE OIL: Refer to the diagrams below.
1. Place generator on level surface.
2. Remove the Right Access Panel (Refer to Controls and Features section).
3. Clean area around Oil Hole Dipstick/Plug & Unscrew Oil Hole Dipstick/Plug.
4. Use Supplied Funnel to Fill with appropriate type and amount of oil using Oil Fill Bottle. Refer
to Chart below for recommended oil type based on Environmental temperature.
NOTE: Refer to “Product Specications” section for universal recommended oil type and oil
amount.
5. Replace Oil Hole Dipstick/Plug and tighten securely.
6. Replace the Right Access Panel.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 19
BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938 19
Operating Instructions
& Owner’s Manual
PRE-OPERATING
INSTRUCTIONS: SETUP
WHEN ADDING FUEL
• Turn generator off and let it cool for a minimum of three minutes before removing fuel cap.
• Turn and remove cap slowly in order to relieve residual tank pressure.
• Always ll the fuel tank with the unit outdoors.
• DO NOT overll tank. Allow room for fuel expansion.
• Keep fuel away from sparks, open ames, heat, pilot lights, and other ignition sources.
ADD FUEL: Refer to Controls and Features section for diagrams.
1. Clean area around fuel cap, then remove fuel cap.
2. Pour fresh, clean regular automotive grade unleaded fuel with a minimum octane
rating of 85 into fuel tank. Do NOT mix fuel with oil. Fuel must have ethanol blend
of 10% or less. Pay close attention to the storage requirements of these fuels. Do
NOT overll fuel tank.
3. Install the fuel cap. Rotate the fuel cap clockwise until
it is in its locked position. Wipe away any spilled fuel.
CAUTION: Alcohol-blended fuels (gasohol, ethanol, or methanol) will attract
moisture, which leads to separation and formation of acids during storage. Acidic gas
can damage the fuel system of an engine while in storage. To avoid engine problems,
the fuel system should be treated with a fuel stabilizer or drained if the generator will
not be started for thirty (30) days. If using a fuel stabilizer, follow the manufacturer’s
recommended instructions for use.
NEVER use chemical solvents or cleaners in the fuel tank for damage may occur.

BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
20 BRAVE GENERATOR PRODUCT SUPPORT 1-888-980-4938
20
Operating Instructions
& Owner’s Manual
CAUTION: Any attempt to start the generator before it has been properly serviced may result
in engine failure and void warranty.
CHECK AIR CLEANER ELEMENT: Refer to diagram below.
1. Remove the Left Access Cover (Refer to Controls and Features section).
2. Remove the Air Cleaner Case.
3. Pull out the Air Cleaner Cartridge, following the direction of the arrow.
4. Check the cleanliness of the Air Cleaner Element.
5. Clean/Replace if needed.
6. Reinstall the Air Cleaner Element.
7. Reinstall the Air Cleaner Case.
8. Reinstall the Left Access Cover.
AIR CLEANER CARTRIDGE
AIR CLEANER ELEMENT
SCREWS
ACCESS
PANEL
SCREWS
PRE-OPERATING
INSTRUCTIONS: SETUP
Table of contents
Other Brave Portable Generator manuals
Popular Portable Generator manuals by other brands

Firman
Firman P03612 Quick reference guide

TSI Instruments
TSI Instruments 8026 Operation and service manual

Parkside
Parkside PGI 1200 A1 Operating and safety instructions

Kohler
Kohler OnCue Plus quick start guide

Northern Lights
Northern Lights M944WF3 Operator's manual

Natural Ozone
Natural Ozone PURIMAX 5G user manual