BRC M500/14 User manual

M500/14
Stand: 04.04.2023 1 / 4
Instruction manual
– Safety instructions for end users -
•Never carry out independent work on the M500/14 or open the housing for any reason.
•Do not allow unauthorized persons to enter the vicinity of the PV system or the Power Optimizer.
•Please keep the instruction manual for reference during all activities related to the product.
– Safety instructions for electricians –
•All work associated with the product may only be carried out by qualified electricians. The electrician must comply with national and regional regulations.
•Please read and follow all instructions carefully before installation. If there are any uncertainties or detailed information is required, please read the extended user
instructions or call our service telephone.
•Electrical work may only be carried out in compliance with the 5 safety rules of electrical engineering.
•To avoid burns, the electrician should wait a few minutes after switching off the system until the optimizers have cooled down sufficiently when dismantling or
replacing the M500/14.
•Install the M500/14 at a sufficient distance from the roof or other surfaces to ensure adequate heat dissipation.
•Only install intact M500/14 with a complete scope of delivery.
•Do not make any modifications to the M500/14.
•In particular, establish a solid electrical connection between the M500/14 and the modules and/or the PV string.
– General notes –
•The M500/14 may only be operated as intended and following the specified technical data.
•The reverse current flow of the Power Optimizer is excluded from the intended use.
Please observe all instructions provided by BRC Solar GmbH in the instruction manual and the warnings on the M500/14.
The warnings on the M500/14 must always be legible and not be removed, changed, or manipulated.
•Applicable local laws, regulations, directives, and standards must be observed as a priority for operation and during installation, uninstallation, and maintenance.
The safety instructions in the instruction manual are incomplete and only serve as a supplement.
Scope of
delivery
Required
accessories
Service:
+49 7243 924 1486
support@brc-solar.de
1x
Instruction manual
M500/14
1x
M8 screw
1x
1x
Flange nut

M500/14
Stand: 04.04.2023 2 / 4
– How it works –
•Since the modules in PV systems are connected in series, the output - i.e., the energy yield of a system - depends on the current strength of the weakest module. If
shade falls on the part of a photovoltaic system, the entire system’s output is severely weakened. Even a single partially shaded module is enough to reduce the
output of all the others.
•Modern inverters can circumvent this problem by activating the bypass diodes of the modules. When the bypass diode is activated, the maximum possible current
(the short-circuit current) flows through the shaded cell string. The difference to the string current flows through the bypass diode and the affected cell string
produces no power.
•Since a short-circuit current still flows through the shaded cell string, the most heavily shaded cell heats up. As a result, there is a risk of a hot spot. Depending on
the duration and intensity it occurs, this hot spot can damage or, in the worst case, destroy the module. Likewise, the bypass diodes can be overloaded and
destroyed if frequently activated.
•The M500/14 is a DC/DC converter connected in parallel to the module via plug-and-play and requires no configuration or adjustment.
•In the event of shading, it is automatically activated by the inverter, similar to the bypass diode. When activated, the Power Optimizer reduces the output voltage
and increases the output current to correspond to the string current. Thus, the BRC Power Optimizer can continue to supply the available module power to the PV
system.
– M500/14 installation –
Step 1: Fastening the M500/14 to the PV module support
1
2
3
Position the flange nut with an M8 screw into the
mounting frame.
Mount the M500/14 on the mounting frame.
Tighten the screw with a torque spanner (9-10 Nm) to
fasten the M500/14.

M500/14
Stand: 04.04.2023 3 / 4
Step 2: Protective measures against electrical shock
Follow the safety instructions on page 1 and the 5 safety rules for electrical work.
Before connecting the M500/14 to the string, check for no string current.
Step 3: M500/14 electrical connection
NOTE:The M500/14 has standard Stäubli MC4 connectors. These must not be connected to other types of connectors.
Step 4: Checking the mounting
After installation, check the fastening of the M500/14 to the mounting frame and the correct electrical connection of the plugs.
Step 5: Startup by switching on the inverter
After completing all the installation work, put the PV system into operation.
1
2
3
If the module is already connected on the string side,
disconnect the connections from the neighboring
modules.
The long cables are connected on the string side.
Pay attention to the polarity.
The short cables are connected to the PV module first.
Pay attention to the polarity.

M500/14
Stand: 04.04.2023 4 / 4
– M500/14 structure –
– Disposal instructions –
•The transport packaging can be recycled under local waste disposal.
•After use, the M500/14 and all associated components must be disposed of as electronic waste following the local laws in force.
– Product conformity –
BRC Solar GmbH, located at Gehrnstraße 7 in D-76275 Ettlingen, Germany, declares that the product M500/14 complies with the basic requirements of the national
directives when the installation instructions are observed and the product is used as intended.
A complete declaration of conformity can be found on the website of BRC Solar GmbH.
– Extended user instructions –
•For more detailed information on the installation, uninstallation, and use of the M500/14, please refer to the extended user instructions.
Scan the QR code or visit our website at (
www.brc-solar.de/
en/
downloads
-en
/
) to go to the extended user instructions.
Table of contents
Popular Portable Generator manuals by other brands

DeVillbiss Air Power Company
DeVillbiss Air Power Company PowerBack A04669 Operator's manual

Power X Generators
Power X Generators 3000 Owner's manual & operating instructions

Troy-Bilt
Troy-Bilt 1924 Illustrated parts list

Mitsubishi
Mitsubishi MGC1101 owner's manual

EcoFlow
EcoFlow R600 PRO user manual

Denver
Denver 4E-180 Series user manual