Brivis HSNBR25 User manual

Due to our policy of continuous improvement, product specification
and details are subject to change without prior notice.
Please contact Brivis on 1300 BRIVIS - 1300 274847 for further information.
USER MANUAL
HSNBR25 - HSNBR32
HSNBR42 - HSNBR50
HSNBR70 - HSNBR80
READ THIS MANUAL FIRST
Please keep this manual in a safe place where you can easily find it. Inside you will find many
helpful hints on how to use and properly maintain your Brivis system. Just a little preventative
care on your part can save you a great deal of time and money over the life of your Brivis system.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review
the troubleshooting tips first, you may not need to call for service.
BRIVIS INVERTER HI-WALL
SPLIT SYSTEM
Thank you for purchasing your Brivis Air Conditioning system.
Please read this user manual carefully prior to operation

CONTENTS
ENVIRONMENTAL RESPONSIBILITY
DISPOSAL: Do not dispose of this product as unsorted municipal waste. Special, separate
collection of this type of product is necessary.
It is prohibited to dispose of this appliance in domestic household waste.
For disposal, consider the following possibilities:
A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) As this product contains valuable resources, they can be recycled and sold to
scrap metal merchants or dealers.
Uncontrolled disposal of waste in forests and landscapes endangers your health when potentially
hazardous substances leak into the ground-water and find their way into the food chain.
ENVIRONMENTAL RESPONSIBILITY
SAFETY PRECAUTIONS
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
OPERATING TIPS
TROUBLESHOOTING GUIDE
Environment.......................................................................................................................2
Warning ..................................................................................................................................3
Caution ...................................................................................................................................4
Component names ....................................................................................................................5
Special functions .....................................................................................................................6
Operating temperature limits ......................................................................................................7
Manual operation ....................................................................................................................7
Airflow direction control ..........................................................................................................8
How the air conditioner works ................................................................................................9
Care and maintenance ..........................................................................................................10
Operating tips .......................................................................................................................12
Troubleshooting tips .............................................................................................................14
Contact an authorised service technician for repair or maintenance of this unit.
This product shall be installed by a suitably qualified installation technician.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by
persons responsible for their safety.
Young children should be supervised to ensure that they do not play with the
air conditioner.
If the power cord needs replacement, this work must be performed by authorised
personnel only.
Installation must be carried out in strict accordance with all local and national wiring
standards by authorised personnel only.
CAUTION

SAFETY PRECAUTIONS
To prevent injury to the user, other people and/or property damage, the following instructions
must be followed. Incorrect operation due to ignorance of instructions may cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Always do this.
Never do this.
CAUTION This symbol indicates the possibility of injury or damage to property.
Connect to the power
supply correctly.
Do not modify power cord
length or share the outlet
with other appliances
Earth the product
properly.
Disconnect the power if
strange sounds, smell, or
smoke are present.
Ventilate room before operating air
conditioner if there is a gas leak
from another appliance.
Incorrect connection may cause
electrical shock or fire due to
overheating.
It may cause electric shock
or fire due to overheating.
Insufficient earthing may
cause electric shock.
It may cause fire and
electric shock.
It may cause explosion, fire or burns.
It may cause electric shock or fire
due to overheating.
It may cause electric shock.
It may cause a failure with
the unit, or electric shock.
It may contain contaminants
and make you sick.
It may cause fire and
electric shock.
It may cause electric shock
or fire.
This may affect your
health.
Intermingled installation may
cause fire or electric shock.
It may cause electric shock.
It may cause explosion or fire.
It may cause failure and
electric shock.
Do not start or stop the
unit by switching on or off
at the power point.
Do not operate with wet
hands or in damp
environment.
Keep water away from any
electrical components.
Do not drink condensate
water from the unit.
Do place the power cord
close to other heating
appliances.
Do not use damaged or
unspecified power cords.
Do not force airflow
directly onto room
occupants.
Always install a circuit
breaker and a dedicated
power circuit.
Do not open the unit
when in operation.
Do not place the power cord near
flammable gases or combustibles, such
as petrol, thinner or cleaning fluids
Do not disassemble or
modify unit.
WARNING
Use the correctly rated
circuit breaker or fuses.
There is risk of fire or
electric shock.
SAFETY PRECAUTIONS
CAUTION
When the air filter is being
removed, do not touch the
metal parts of the unit.
It may cause injury.
Do not clean unit when
power is on as it may cause
fire, electric shock or injury.
There is a risk of water
ingress and electrical failure.
When cleaning the unit,
switch off, and isolate at the
circuit breaker.
Turn unit off in electrical
storms or severe weather.
Use caution when unpacking
and installing this product.
Water may enter the unit and
cause a failure. It may also
cause an electric shock.
It may adversely affect the
pet or plants.
Do not place unit where air
flow is directed onto pets or
plants.
Ventilate the room
when used near gas
appliances etc...
An oxygen shortage
may occur.
Do not use this unit to
preserve precision
devices, food, pets,
plants, or art objects. It
may cause deterioration.
It may cause failure of
the product or fire.
Do not use for any
other purposes other
than intended purpose
Turn off at the mains
when not using for
extended periods.
If water enters the
unit, turn the unit off,
disconnect the power
and contact a qualified
service technician for
inspection.
It may cause failure of
appliance or injury.
Product appearance and/or
integrity may deteriorated due
erosion and/or scratching
of the product.
Do not place obstacles
around air-inlets or inside
of air-outlet.
Do not use strong detergents
such as spirit or thinners. Use
a soft cloth for cleaning.
If the bracket is damaged,
there may be a risk of the
product falling.
There is danger of fire or
electric shock.
Ensure that any installation brackets
are not damaged due to prolonged
exposure to the elements.
Do not place heavy objects on the
power cord. Take care not to
damage or compress the cord.
Operation without filters
or with blocked filters
may cause failure.
Always insert the filters
securely. Clean filter
regularly.
Do not spray or clean the unit
with water.
Do not put place any objects
in the air discharge of the
unit.
It may cause damage to the
rotating fan.
Sharp edges may cause injury
could cause injury.

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS
8. Interconnecting refrigerant pipe (supplied
by installer)
9. Interconnecting wiring cable (supplied by)
installer)
10. Stop valve
Outdoor unit
Outdoor unit
LED Display Window
Indicating lamp on LED Display window
1. Front panel
2. Air inlet
3. Air filter (Behind front panel)
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver (internal)
7. Display window
Signal receiver
Indoor unit
Indoor unit
Special functions
NOTE:
The pictures in this manual are for
explanation purposes only. Your air
conditioner may differ slightly.
Vertical Swing Function
When the unit is turned on, the users can control the swing of the vertical louver swing by
the button on the remote control.
9
10
8
OPERATION indicating lamp
This lamp is illuminates when the air
conditioner is operating.
TIMER indicating lamp
Lit during Timer operation.
DEFROST indication lamp
Lights up when the units enters the defrost
cycle automatically or when the warm
air control feature is activated in heating
mode.
Temperature indicator
Displays the temperature settings when the
unit is operating.
Displays the troubleshooting fault codes.
Self Clean Function
This function operates after the unit has been in cooling mode to clean the Evaporator
and keep it fresh for the next operation.
The unit will operate in the following sequence :
1 - FAN ONLY mode at Low fan speed
2 - HEATING mode at Low fan speed
3 - FAN ONLY operation
4 - Stop Operation
5 - OFF.
Note:
This function is only available in COOL (AUTO COOL, FORCED COOL) and DRY modes.
Before selecting this function, it is recommended to run the unit in Cooling mode for
approximately 30 minutes. Once the Self Clean function is activated, all TIMER
settings will be cancelled.
In Self Clean mode, if the SELF CLEAN button on the remote control is pressed,
the unit will stop and turn off automatically.
Louver Angle Memory Function
Upon restarting the unit, the angle of the horizontal louver will automatically return to
the same position set last time.
In the following circumstances, the louver will return to the standard angle:
1) Pressing the turbo function or manual control button.
2) Turning power off and on to unit
3) Unplugging the unit (if applicable)
Refrigerant Leak Detection
With this technology, the LED display window will display “EC”. The indicating lamp will
continue to flash when the outdoor unit detects a potential refrigerant leak.

OPERATING INSTRUCTIONS
Airflow direction control
Adjust the air flow direction as required so as not to
cause discomfort to the occupant or cause uneven
room temperatures.
Adjust the horizontal/vertical louvers using the remote
control.
To set the horizontal/vertical air flow direction
Perform this function while the unit is in operation.
Use the remote control to adjust the air flow direction.
The vertical/horizontal louvers change 6 degrees in angle
for each press of the button. The louver can also be
set to swing automatically.
Please refer to the Remote Control Manual for details.
:WARNING
IMPORTANT: Please do not insert your fingers or other
objects into the unit. The rotating supply air fan inside
may cause damage or injury.
Do not operate the unit for extended periods with the
air flow direction set downward in cooling or
dehumidifying mode. Condensation may form on the
surface of the horizontal louver causing moisture to
fall from the unit.
When the unit is restarted immediately after being
turned off, the louvers may not respond for up to
10 seconds as they reset their position.
The angle of the horizontal louver should not be set
at an overly acute angle, as this may reduce
performance as a result of restricted air flow.
The horizontal louver should not be positioned by hand.
This will force the horizontal louver out of sync. If this
occurs, please isolate the power supply for 10 seconds,
then restart the unit.
Do not operate the unit with horizontal louver in the
closed position, this will cause a malfunction due to
restricted air flow.
CAUTION
Manual operation can be used temporarily in case the remote control is disabled or
the unit requires service/maintenance.
OPERATING INSTRUCTIONS
Manual operation
NOTE: This manual does not include information regarding the Remote Control, please
see the Remote Control Manual, which is packed with the indoor unit.
Operating temperature limits
Manual control button
Suspension bars
Manual control button
AUTO/COOL
AUTO/COOL
( )1
( )
2
Range
Range
Open and lift the front panel up at an angle
until it clicks and remains in place.
One press of the manual control button will
start forced AUTO operation. If pressed
twice within five seconds, the unit will
operate under forced COOL operation.
Close the panel firmly to its original
position.
This button is used for testing purposes
only. Do not use it for normal operation.
To restore to the remote control operation,
use the remote control directly.
CAUTION:
1
3
2
NOTE: The unit must be turned off before
using the manual control button. If the
unit is operational, hold down the manual
control button until the unit is off.
Mode
Temperature
Room temperature
Outdoor temperature
1. Optimum performance is achieved within these operating temperature limits. If the unit
is used outside the above limits/conditions, certain safety protection features may be
brought into operation and cause the unit to not function as intended.
2. Room relative humidity must be less than 80%. If the unit operates in an environment in
excess of this value, the surface of the unit may attract condensation. In this case, please
set the vertical air flow louver to its maximum angle (vertically to the floor), and set the
fan speed to HIGH.
NOTE:
Cooling Heating Drying
17 C
0
0 C ~ 50 C
0 0 -15 C ~ 30 C
0 0
10 C
0
0 C ~ 50 C
0 0
30 C
0
This manual suits for next models
5
Table of contents
Other Brivis Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual