Brivis MON2H053 User manual

Brivis
Inverter Multi-Head
R410A
INSTALLATION MANUAL
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLING & USING THIS PRODUCT
Split System

1
CONTENTS
SAFETY PRECAUTIONS
Warning .............................................................................................................................................2
Caution ..............................................................................................................................................2
INSTALLATION INSTRUCTIONS
Selecting installation position .............................................................................................................4
Hi-Wall indoor unit .............................................................................................................................4
Ducted indoor unit ............................................................................................................................9
Outdoor unit installation ...................................................................................................................14
REFRIGERANT PIPE CONNECTION
Refrigerant pipe connection ............................................................................................................15
Inside you will find many helpful hints on how to install, test and operate the Brivis system properly.
All illustrations and specifications in this manual are subject to change without notice.
Please read this manual carefully and retain for future reference
ELECTRICAL INSTALLATION
Electrical installation ........................................................................................................................16
COMMISSIONING AND TEST RUN
Commissioning ................................................................................................................................22
REFRIGERATION
Air purging with vacuum pump ........................................................................................................19
Electrical safety and leak test ..........................................................................................................21
Installation must be carried out by suitably authorised and qualified personnel.
This appliance must be installed in accordance with all local and national wiring regulations.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Young children should be supervised to ensure that they do not play with the system.
Do not install this system in a wet room such as a bathroom or laundry.
CAUTION
Outdoor Hi-Wall Indoor Slim Ducted Indoor
MON2H053 MINHW020 MINSD020
MON3H076 MINHW026 MINSD026
MON4H078 MINHW035 MINSD035
MON5H105 MINHW052 MINSD052
MON5H136 MINHW070 MINSD070
Model Numbers
13.6kW Outdoor Unit available late 2014
SPECIFICATIONS
Technical data ...................................................................................................................................3

2
SAFETY PRECAUTIONS
WARNING
Please read the follow SAFETY PRECAUTIONS carefully before installation.
Electrical work must be installed by a licensed electrician. Be sure to use the correct wiring ratings
for power and communications wiring.
Incorrect or incomplete installation or failure to adhere to these instructions may cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
The items to be followed are classified by the symbols:
Symbol denotes item that is PROHIBITED.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
1) Only qualified personnel shall undertake the installation. If the installation is defective, it may cause water or
refrigerant leaks, electrical shock or fire.
2) Install strictly in accordance with these installation instructions. If installation is defective, it may cause water
or refrigerant leaks, electrical shock or fire.
3) Use the appropriate accessories/parts and specified items for installation. Otherwise, the equipment may fall,
leak refrigerant or water, or cause electrical shock or fire.
4) Install the equipment in a strong, firm location, able to withstand the unit’s operating weight. If the installation
location is insufficient or the installation is incomplete, the equipment may fall and cause injury.
,
5) For electrical work, follow all local and national wiring standards and regulations, and in accordance with the
installation instructions. An independent circuit must be used. If the electrical circuit capacity is insufficient or
defective, it may cause electrical shock or fire.
6) Use the specified cables sizes and connect tightly. Clamp the cable so that no external force can be acted on
the terminals. If the connection or fixing is inadequate, the connections may overheat and cause fire.
7) Wiring routing must be properly arranged so that control board cover is fixed properly. If the control board
is not properly fixed, it may cause the connections to overheat and cause fire or electrical shock.
8) When carrying out piping connection, take care not to let air or other contaminants enter the refrigeration
system. Use only clean, specified refrigerant, otherwise the system will operate at a lower capacity/efficiency,
or at abnormally high pressures causing risk of explosion or injury.
9) Do not modify the length of any power supply cords or use extension cords. Do not share the power
supply with other electrical appliances. Otherwise, it may cause fire or electrical shock.
CAUTION
1) This equipment must be suitably earthed and installed with an appropriate circuit breaker. Electrical shock may
occur if the grounding is inadequate.
2) Do not install the unit in an area where leakage of flammable gases may occur. If the refrigerant leaks and
is allowed to accumulate around the unit, it may cause fire.
3) Install the condensate drain piping as per the installation instructions. If the drainage is inadequate or
incomplete, it may leak into the space and cause damage.
5) Do not install or operate this system in a wet room such as a bathroom or laundry.
4) The appliance shall be installed in accordance with all local and national wiring regulations.

3
SPECIFICATIONS
MON2H053 MON3H076 MON4H078 MON5H105 MON5H136
Qty 2 3 4 5 5
V-Ph-Hz
Rated Capacity (Maximum) 5.3 (6.77) 7.6 (10.18) 7.7 (10.96) 10.4 (12.68) 13.6 (15.12)
Power Input 1.48 2.25 2.23 3.05 3.57
Running Current A 6.6 9.96 9.86 13.36 15.6
AEER W/W 3.48 3.27 3.35 3.33 3.71
2 2 2 2 2.5
Rated Capacity (Maximum) 5.8 (6.86) 8.1 (10.18) 8.4 (11.03) 11.6 (13.48) 14.5 (15.54)
Power Input 1.60 2.16 2.30 3.09 4.327
Running Current A 7.16 9.58 10.22 13.56 18.88
ACOP W/W 3.50 3.62 3.53 3.64 3.618
2.5 2.5 2.5 2.5 2.5
Type Twin-rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary
A 14.5 16.5 17.0 25.0 26.0
67 69 69 73 73
60 60 61 64 64
Net (W x D x H) mm 845 x 320 x 700 900 x 315 x 860 900 x 315 x 860 990 x 345 x 965 938 x 392 x 1369
Gross (W x D x H) mm 965 x 395 x 755 1043 x 395 x 915 1043 x 395 x 915 1120 x 435 x 1100 1095 x 495 x 1505
Net / Gross Weight kg 48 / 52 62 / 66 64 / 68 89 / 93 100 / 112
Refrigerant Type
Connection Size: Liquid Line 2x Ø6.35 3x Ø6.35 4x Ø6.35 5x Ø6.35 5x Ø6.35
Connection Size: Gas 2x Ø9.52 2x Ø9.52
1x Ø12.7
3x Ø9.52
1x Ø12.7
4x Ø9.52
1x Ø12.7
4x Ø9.52
1x Ø12.7
Maximum Total System Pipe Length 30 45 60 75 75
Pre-Charged Length 20 30 40 50 50
Maximum Length Per Indoor Unit 20 25 30 30 30
Maximum Vertical Separation
Outdoor Unit ABOVE Indoor Unit 10 10 10 10 10
Maximum Vertical Separation
Outdoor Unit BELOW Indoor Unit 15 15 15 15 15
Maximum Height Difference
Between Indoor Units 10 10 10 10 10
Cooling
Heating
MINHW020 MINHW026 MINHW035 MINHW052 MINHW070
V-Ph-Hz
Rated Capacity (Range) kW 2.0 (1.71 ~ 3.71) 2.6 (1.90 ~ 4.04) 3.5 (2.21 ~ 4.71) 5.2 (3.03 ~ 6.46) 7.0 (4.25 ~ 9.06)
Power Input W 24 24 24 60 72
Rated Current A 0.11 0.11 0.11 0.27 0.33
Rated Capacity (Range) kW 2.3 (1.78 ~ 3.79) 2.9 (1.97 ~ 4.20) 3.8 (2.25 ~ 4.80) 5.5 (3.13 ~ 6.68) 7.5 (3.93 ~ 8.38)
Input W 24 24 24 60 72
Rated Current A 0.11 0.11 0.11 0.27 0.33
L/s 147 / 128 / 97 147 / 128 / 97 175 / 150 / 120 278 / 222 / 195 389 / 361 / 292
dB(A) 41 / 35 / 25 41 / 35 / 25 45 / 40 / 32 46 / 39 / 32 52 / 48 / 38
Net (W x D x H) mm 750 x 198 x 280 835 x 198 x 280 835 x198 x 280 990 x 218 x 315 1186 x 258 x 340
Gross (W x D x H) mm 830 x 270 x 355 910 x 270 x 355 910 x 270 x 355 1065 x 300 x 400 1265 x 420 x 340
Net / Gross Weight Kg 8 / 10 9 / 11 9 / 11 12 / 14 18 / 23
Refrigeration Pipe Size: Liquid / Gas mm Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø12.7 Ø9.52 + Ø12.7
Type
oC
MINSD020 MINSD026 MINSD035 MINSD052 MINSD070
V-Ph-Hz
Rated Capacity (Range) kW 2.0 (1.71 ~ 3.71) 2.6 (1.90 ~ 4.04) 3.5 (2.21 ~ 4.71) 5.2 (3.03 ~ 6.46) 7.0 (4.25 ~ 9.06)
Power Input W 30 40 50 80 100
Rated Current A 0.13 0.18 0.23 0.37 0.46
Rated Capacity (Range) kW 2.3 (1.78 ~ 3.79) 2.9 (1.97 ~ 4.20) 3.8 (2.25 ~ 4.80) 5.5 (3.13 ~ 6.68) 7.5 (3.93 ~ 8.38)
Input W 30 40 50 80 100
Rated Current A 0.13 0.18 0.23 0.37 0.46
L/s 167 / 150 / 128 167 / 150 / 128 200 / 167 / 150 222 / 170 / 145 389 / 333 / 303
Pa 40 40 40 70 70
dB(A) 36 / 33 / 30 36 / 33 / 30 39 / 36 / 34 42 / 39 / 37 45 / 41 / 38
Net (W x D x H) mm 700 x 635 x 210 700 x 635 x 210 700 x 635 x 210 920 x 635 x 210 920 x 635 x 270
Gross (W x D x H) mm 915 x 655 x 290 915 x 655 x 290 915 x 655 x 290 1135 x 655 x 290 1135 x 655 x 350
Net / Gross Weight kg 18 / 23 18 / 23 18 / 23 23 / 29 28 / 32
Refrigeration Pipe Size: Liquid / Gas mm Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø9.52 Ø6.35 / Ø12.7 Ø9.52 + Ø12.7
mm OD Ø25 OD Ø25 OD Ø25 OD Ø25 OD Ø25
Type
oC
E & OE
OUTDOOR UNIT
Maximum Number of Indoor Units
Power Supply 220~240-1-50
Heating
kW
Star Rating
Cooling
kW
Star Rating
Compressor
Maximum Input Current
Sound Power Level dB(A)
Sound Pressure @ 1m
Dimensions
R410A
Refrigerant Piping
mm
m
220~240-1-50
Cooling
Heating
Ambient
Operating Range
oC-15 ~ 50
-15 ~ 24
Airflow (Hi / Med / Lo)
Sound Pressure (Hi / Med / Lo) @1m
Dimensions
INDOOR UNIT - HIWALL
Power supply
INDOOR UNIT - DUCTED
Power supply 220~240-1-50
Cooling
Heating
Control Wireless Remote Control
Indoor Operating Range 17 ~ 30
Capacities tested in accordance with AS 3823.3, with 5m interconnecting length for all attached Indoor Units.
Condensate Drain Connection
Control Wired Manual Thermostat
Indoor Operating Range 17 ~ 30
Airflow (Hi / Med / Lo)
Maximum External Static Pressure (Hi)
Sound Pressure (Hi / Med / Lo) @1m
Dimensions

4
Selecting installation position
Read completely, then follow step by step.
Indoor unit
Do not expose the indoor unit to external heat or steam.
Select a position where there are no obstacles
in front or around the unit.
Make sure that the condensate drain and pipework can
be conveniently routed.
Do not install near doorways.
Ensure that the clearance to the left and the right
of the unit is more than 12cm.
Use a stud finder to locate studs for secure mounting and prevent damage to the wall.
The indoor unit should be installed on the wall at a height of 2.1 metres or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling above.
Any variations in pipe length may require adjustment to the refrigerant charge.
Install away from direct sunlight. The sun may fade the plastic cabinet and affect its appearance.
If unavoidable, adequate sunlight prevention should be taken into consideration.
Outdoor unit
If an awning is built over the outdoor unit to minimise
direct sunlight or rain exposure, ensure that the
air paths and heat radiation from the condenser is
uninhibited.
Ensure that the clearance to the back of the
unit is more than 30cm and left side is more
than 30cm. The front of the unit should
have more than 100cm of clearance and the
connection side (right side) should have more
than 60cm of clearance.
Do not place animals or plants in the path of the air inlet or outlet.
Take the unit’s operating weight into account and select a suitable position to minimise noise
and vibration both internally and externally.
Select a suitable position so that the air discharge and noise from the unit does not disturb neighbors.
If the outdoor unit is installed on a roof structure, ensure it is installed on a secure level base.
Ensure the roof structure and securing method are adequate for the unit location.
Consult local codes and regulations regarding roof mounting.
If the outdoor unit is installed on roof structures or external walls, this may result in
excessive noise and vibration, it may also be classed as a non serviceable installation, and void
Roof installation:
INSTALLATION INSTRUCTIONS
More than 30cm
More than 60cm
More than 30cm
More than 100cm
Fig.2
More than 210cm
More than 15cm
More than 12cm
More than 12cm
Fig.1
1. Hi-Wall type
the manufacturers warranty.
This manual suits for next models
14
Table of contents
Other Brivis Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual