
EXTERIOR & IN-LINE BLOWER MOUNTING PLATE
KIT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone num-
ber listed in the warranty.
2. Beforeservicingorcleaningunit,switchpoweroff
atservicepanelandlockservicepaneltoprevent
powerfrombeingswitchedonaccidentally.When
the service disconnecting means cannot be
locked, securely fasten a prominent warning de-
vice, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
allapplicablecodesandstandards,includingfire-
rated construction codes and standards.
4. Sufficientairisneededforpropercombustionand
exhaustingofgasesthroughtheflue(chimney)of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's
guideline and safety standards such as those
published by the National Fire Protection Asso-
ciation (NFPA), and the American Society for
Heating,RefrigerationandAirConditioningEngi-
neers (ASHRAE), and the local code authorities.
5. Whencuttingordrillingintowall,orceiling,donot
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the out-
doors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
2. Toavoidmotorbearingdamageandnoisyand/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.
3. Your hood motor has a thermal overload which
will automatically shut off the motor if it becomes
overheated. The motor will restart when it cools
down. If the motor continues to shut off and
restart, have the hood serviced.
4. Please read specification label on product for
further information and requirements.
MODEL 335
EXTERIOR BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND
DUCT
SOFFIT
24" or 27"
18" ROUGH-IN
PLATE
DUCT
OPENING
COVER PLATE
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
NOTE: Horizontal discharge requires relocation of the duct opening cover plate. See hood manual
for instructions.
MODEL
335
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
ROUGH-IN
PLATE
24" or 27"
18"
10" ROUND ELBOW
DUCT OPENING
COVER PLATE
12" MIN.
ABOVE ANY
OBSTRUCTION
SOFFIT
MODEL 335
EXTERIOR
BLOWER
10" ROUND DUCT
24" or 27"
18"
DUCT
OPENING
COVER
PLATE
WALL HOOD
CANOPY
(island canopy
available)
ROUGH-IN
PLATE 12" MIN.
ABOVE ANY
OBSTRUCTION
SOFFIT