Replacing Batteries & Maintenance
USE ONLY ALKALINE BATTERIES
Expected Battery Life
Timer: 200 hours
Wand: 300 hours
Photocell A: 200 hours
Photocell B: 250 Hours - Low setting – 10 Meters.
220 Hours - Medium – 22 Meters.
100 Hours - High – 38 Meters.
Changing Batteries
DO NOT INSTALL BATTERIES BACKWARDS!!!
Timer: Remove the 4 screws holding the backplate. Attach tripod to the
backplate. Remove backplate to reveal the batteries. Replace with: 3 AA
Energizer Alkaline batteries.
Wand: Remove the 4 screws holding the bottom plate and open the Wand
like a book. When removing the battery brace make sure to loosen the set
screw at the base of the back with an allen wrench. Replace the batteries
and re-assemble in reverse order. Replace with: 3 AA Energizer Alkaline
batteries.
Photocell A and Photocell B: With a screwdriver, remove the setscrew on
the bottom of the unit. Press on the face of the unit below the lens to slide
the guts of the unit out of the housing. Replace with: 3 AAA Energizer
Alkaline batteries.
Maintenance
The Photocell A and Photocell B are susceptible to water inltration in
heavy rain or wet snow. If water does get inside, remove the housing and
remove the batteries. Let stand until dry. Replace batteries.
Crystal Calibration (once a year)
The RL System uses ultra high precision clock crystals to insure accurate
timing. Over 1-2 years the crystals can age and loose small amounts of
accuracy. It is suggested that the Wand and Photocell A units be calibrated
at the beginning of every season. (New systems do not require calibration)
Open the Timer, Wand, and Photocell A units and locate each unit’s USB
jack. Use the male to male USB cable to connect the Timer and Wand.
The calibration starts automatically and takes 30 seconds. Repeat the
process for each Photocell A.
Electrical Specications
Radio frequency 433.425MHz 25kHz spacing.
Modulation method FM.FSK. 32 Channels
Temperature rating - 20 degrees C.
Receiver sensitivity .18 uV
Transmitter power Low 10 mW, High 135 mW
Transmission distance 5 miles line-of-sight
Memory capacity all components store 499 skiers times
Warranty
All products have a 1 year warranty. Brower Timing will repair or replace
any failed product at no charge for 1 year from time of purchase. Damage
caused by user is not covered by the warranty.
Customer will pay the cost to ship to Brower, Brower will pay for return
shipping.
Diagnose Malfunction and Return Procedure
Go to www.browertiming.com to complete the return checklist.
1- Determine which component is failing and call or email Brower Timing
to conrm that it must be returned.
2- To reduce shipping cost, send only the failed component packaged in
the smallest box available.
3- Include all your contact information and Visa or Mastercard number
with expiration date and last 3 digits on the back of the card. Also it is
very important to write a description of the problem
4- If shipping from outside of the USA send by Post ofce and label the
package “Return for repair, Charge no duties”. Expected turnaround time
is 16 days, and shipping cost will be minimal.
5- If a faster turn around time is required (8 days) 2 way shipping costs
can reach $300.00 to some countries.
6- Send all repairs directly to Brower Timing Systems.