BTEK BT-470TL User manual

Page | 1
BT-470TL REMOTE DISPLAY
Item# 841-100043 / 841-100044
OPERATION & SETUP GUIDE V1.0

Page | 2
Contents
Introduction................................................................................................................................................... 3
Downloads................................................................................................................................................. 3
Wall and Pole Mounting................................................................................................................................ 4
Autolearn Mode............................................................................................................................................ 6
Embedded User Menu .................................................................................................................................. 7
Factory Default.......................................................................................................................................... 8
Connecting the Display to a Computer for Configuration Purposes.............................................................. 9
WagSet (Windows Operating System only)............................................................................................. 10
Web Panel Configuration Method........................................................................................................... 11
Remote Display Connections....................................................................................................................... 12
Ethernet Settings to Transmit Weight Data ................................................................................................ 13
Replacement Part Item Numbers................................................................................................................ 14

Page | 3
Introduction
BT-470TL remote display is designed to display measurement results transmitted by
weighing terminals. The display operates in the automatic mode by default (see Autolearn)
and in standard installations does not require prior configuration. For advanced options, it is
necessary to adjust the settings via WagSet software (from version v3.00), or through the
user menu embedded in the device, or Web browser.
The WagSet software enables advanced configuration of the device:
•Defining of the communication protocol with any weighing terminal,
•Restoring the default settings, displaying the software version, displaying the saved
communication protocol, and changing the network settings
•Setting the response to events reported by the weighing terminal (e.g. overloading,
underloading, instability, scale error)
•Enabling Alpha characters to be displayed within the data string.
•Setting advertising text in the following languages: EN, PL, RU, DE, CZ, SK, HU, UA,
LT, LV, NO, SE, FR, NL, BR, RO, ES, TR, FI.
•Changing the IP address and port of the weight indicator sending the data.
Default Indicator IP: 192.168.1.12 sending data on port 2102
The detailed information concerning the display configuration from a PC can be found in the
manual supplied with the WagSet software. Click Help > Help or press the F1 button. The way
of connecting the display to a PC is described in the “Connecting the display to a computer for
configuration purposes” section of this manual.
The user menu embedded in the device allows the basic display configuration without using a
PC:
•Manual selection of the communication protocol from the list, enabling the operation with
selected weighing terminals
•Restoring the default settings, displaying the software version, displaying the saved
communication protocol, communication ports, displaying the IP address, and subnet
mask.
Downloads
WagSet: WagSet Software Download
Devicer 2.08: Devicer 2.08 Download
Firmware: Firmware_v3.16

Page | 4
Wall Mounting
The BT-470 Item# 841-100044 can be wall mounted by fastening the two angle brackets to the
side of the display, then attaching to a sturdy wall. When installing without the visor, it is
recommended to install in an area protected from direct sunlight and rain.
Item# 841-100043 includes a visor, and pole mounting hardware. The kit included brackets for
a 3” pole, but other sizes can be purchased as needed. Attach the Unistrut to the back of the
visor, then slide clamps into unistrut, tighten the bolt to secure to the pole. Then attach
scoreboard to the visor, selecting one of the three holes to adjust display angle.
Optional Visor for pole or wall mounting

Page | 5
Pole Mounting
The mounting rails are fitted directly to the rear part of the device housing with the screws included in the set.
They enable the installation of mounting clamps, which are used to install the device on a pole.
Two mounting rails are provided for each remote.
Key:
1- flat bar with threaded pivots to be inserted into the mounting rail,
2- pipe / pole,
3- mounting bolts with a set of nuts and washers,
4- mounting elements of the fastening.
The mounting clamps for pipes are available in the following size:
•107-01-25-001 - Mounting clamps for mounting the device on poles 2” –4” (60 - 129 mm in diameter).
In order to properly install the device on the pole, two rails and two mounting clamps should be used.

Page | 6
Autolearn Mode
The autolearn mode is enabled by default (position no. 0 is set in the 'proto' submenu). To
disable it, the communication protocol must be set manually using the embedded user menu or
the WagSet software.
When autolearn mode is active, each time the device is started, it detects the parameters of the
communication with the weighing terminal and analyses the structure of the data frames it
sends. Then it adjusts the remote display's settings to enable correct communication with the
terminal. The whole operation lasts several seconds, depending on the baud rate and the time
intervals between consecutive frames. All remote display’s communication interfaces are
supported, i.e. RS232/RS485/CL and Ethernet.
The autolearn procedure is as follows:
1. Baud rate detection - dot 1 flashing on the display
2. Baud rate verification - dot 1 solid, dot 2 flashing
3. Analysis of the protocol and its frame structure - dots 1 and 2 solid, dot 3 flashing
During the analysis of the protocol and its frame structure, the measurement unit sent is also
recognized. The following tags are recognized - "kg" 'K' " t" 'T' 't' " g" "gr" 'G' 'g' "lb" 'L' 'l' "oz" 'o'
'O'. In case the terminal does not send a unit or sends a unit that is not recognized by the
autolearn function, the default unit will be set to lb.
The "Autolearn" function detects gross/net measurements if the following markers in the frame:
- for the Net measurement: "N" from the ASCII table,
- for the Gross measurement: "G" from the ASCII table.
The "Autolearn" function detects Traffic Light status if the following markers in the frame:
- Green: "B" from the ASCII table,
- Red: "R" from the ASCII table.
The autolearn mode supports the following transmission parameters:
Baud Rate
2400, 4800, 9600, 19200
Transmission parameters (data bits, parity, stop bits):
8N1, 7E1, 7O1
Note: If the data is sent via the Ethernet to the display and then one of the other interfaces, i.e.
RS232 / RS485 / CL is connected - the autolearn procedure will be carried out again in order to
determine the UART parameters and the protocol (the protocol for serial interfaces may differ
from the Ethernet protocol).

Page | 7
Embedded User Menu
The button used to operate the menu is located on the controller board inside the display
housing and marked B1. To access, unscrew the two philips head screws and slide out the
controller board drawer. Once you have finished the configuration, push the drawer back,
making sure that the seal is not compromised.
Fig. 1
Location of button B1
The user menu has the following options:
▪info
▪proto
▪custm
▪lights
▪reset
To activate a specific option, keep the button pressed until this option appears on the screen
("info", "proto", "custm" or "reset"). The option is entered after releasing the button when its
name is being displayed. If the button is released when the screen is blank between two
consecutive options, the display will return to its normal operation.
"info" option allows you to display the device software version and the network layer settings (IP
address, network mask, communication port for the WagSet software and communication port for
the weighing terminal).

Page | 8
“proto”option allows you to select the display communication protocol to work with the selected
weighing terminals (Tab. 1). You can change the protocol by short pressing the button. Saving
the selected protocol is accomplished by long holding down the button (until the messag
"Saved" appears). Exiting the "proto" option happens automatically after 30 seconds of user
inactivity
“custm” option allows you to select the display communication protocol to work with the
weighing terminals of the selected clients. These protocols have special, custom settings
needed for the given client. Setting the protocol is done in the same way as in the case of the
"proto" option - saving the selected protocol is accomplished by long holding down the button
(until the message "Saved" appears), while exiting the "custm" option happens automatically
after 30 seconds of user inactivity.
"lights" option allows you to choose the configuration of the traffic lights. Three profiles are
available:
•1 –lights: if there is no communication for more than 0.5 second, the red light will show,
•2 –lights: if there is no communication for more than 3 seconds, the "X" characters will be
displayed on both red and green light,
•3 –lights: if there is no communication, the status of the traffic light will not change.
Switching between the individual profiles is done by pressing the "B1" micro button. Saving the
selected profile is accomplished by long holding down the "B1" micro button, until the message
"Saved" appears. Exiting the "lights" option comes after 30 seconds of the user inactivity.
Factory Default
“reset” option allows you to restore the default settings of the remote display and to activate the
autolearn mode. The default network layer settings will also be restored (IP address:
192.168.1.11, network mask: 255.255.255.0, configuration port for the WagSet software: 2101,
communication port for the weighing terminal: 2102). To restore the default settings you should
press the B1 button and hold it down until the message "reset" appears during the normal
operation of the device. Hold the button down until the message "reset" starts flashing and do
not release it until the message "default" is displayed. Releasing the button before the message
"default" appears will result in interrupting the process of restoring the default settings and the
display will continue working according to the previously set parameters. Uploading new
network settings is possible using the WagSet software or via web panel.

Page | 9
List of the supported protocols
Note: “Proto” 53 is the B-TEK string bold font, “Proto” 54 is B-TEK string normal font,
“Custm” 28 is the Bilanciai Extended String.
Note 2: B-TEK strings allow alpha characters to be displayed in place of weight data.
Seq.
no.
Terminal name
Protocol
Seq.
no.
Terminal name
Protocol
0
Autolearn function
28
CAS NT570A
1
Rhewa 83 Plus
29
Cardinal 825
2
Radwag
30
Cardinal 204 225 748P
3
HBM WE2108
31
AMCS Group
4
HBM WE2110
32
A&D AD4329 AD4401
5
Rinstrum 320 420
Auto1
33
Ian Fellows SG0
6
SysTec / Pronova
34
Ian Fellows SG0 Status
7
SysTec
35
Zemic
8
Precia Molen
Master D
36
Pfister DWT800
9
Precia Molen I300 Slave A+
37
Pfister DWT410
10
Precia Molen I300 Master A+
38
Axis Long
11
Dini Argeo
Standard String
39
Avery L225
12
Mettler Toledo IND560
40
T –Scale U8
13
Fawag
P2
41
Rice Lake 480 920i
14
Leon Engineering
W-OUT
42
Vishay VT300
15
Soehnle 3010 3011 3015
13
43
Belt Way
16
Eurobil bilance Iscale
Continua
44
Axtec
17
Compatible with the SMA protocol
SMA
45
GSE 460 465
18
Sartosius
Remote Control
46
GSE 250
AUTO1
19
Sensocar
47
STB-22
20
Flintec
48
Utilcell Matrix II
Format1
21
Schenck
Disomat B
49
Precia Molen i35
Master A+
22
Scheneck Opus Serial
50
Precia Molen i35
Master D
23
Gravex GX2SS
51
SMART SWIFT
24
Gravex GX18
52
Epelsa: BC, BI, Dexal, Cyber, Orion, Orion
Plus, Cyber Plus, V-36
Epelsa Cada
LetraB1
25
IHG TMI LP7510
53
B-tek String - Bold Font
Serial String
26
Arpege MasterK
54
B-tek String –Normal Font
Serial String
27
Bilanciai D410

Page | 10
Connecting the Display to a Computer for
Configuration Purposes
WagSet (Windows Operating System only)
WagSet Software Download
Before configuring the display from WagSet, connect it to a computer via Ethernet or RS232.
When using RS232, connect to the port of the computer as shown in the fig. below. See
“Remote Display Connections” for location of the RxD and GND connections.
To display alpha characters, select one of the B-TEK strings in configuration. Open the file, then
select the measurement result tab, then select “display” under “Display every character in the
result area”. Send configuration to the display. In your weight data stream, characters 3 thru 9
(same as weight digits) can be used to display messages on the display.

Page | 11
Web Panel Configuration Method
To access the web panel, follow the instructions below:
1. In the network card properties select “Internet Protocol Version 4 (TCP/IPv4), and click
“Properties”.
2. In the “Internet Protocol Version 4 Properties”, select “Use the following IP address”
option, and then complete the following fields: IP address: 192.168.1.55, Subnet mask:
255.255.255.0 and confirm changes.
3. Download Devicer 2.08 Devicer 2.08 Download.
4. Open Devicer program, then click the binocular icon to search.
5. Double click the IP address of your scoreboard.
6. When the web browser opens enter: login: admin pass: dbps
In the web browser, network settings can be modified, password can be changed (not
recommended), Protocols can be selected, Status information, Update firmware, and
factory default the display.
Note: The BT-470 works best with a Google Chrome browser. Other types might not connect
correctly.

Page | 12
Remote Display Connections
NOTICE! The controller board should only be accessed when the power supply is disconnected.
Take special care when doing this because of the danger of electric shock.
Interface / Function
Connector
marking
Notes
RS-232
RxD
RxD line of the RS-232 interface. The line should be connected with the
weighing terminal TXD output.
GND
GND line of the RS-232 interface.
0/20mA (CL) digital
current loop
CL+
CL line of the current loop. The line should be connected with the weighing
terminal TXD output.
CL-
GND line of the current loop interface.
RS-485
RS-422
D+
RS-485 and RS-422 interface non-inverting line.
D-
RS-485 and RS-422 interface inverting line.
GND
GND line of the RS-485 and RS-422 interfaces for use at risk of a significant
difference in the potentials of the display and the weighing terminal.
Dry-contact
GND
GND line of the operator panel.
C1
Signal line activating the red light.
C2
Signal line activating the green light.
5V
- not used -
Ethernet
Ethernet
RJ-45 socket.
Power supply
110 ÷ 230 VAC
L
Phase conductor.
N
Neutral conductor.
PE
Protective conductor.

Page | 13
Ethernet Settings to Transmit Weight Data
•Default display IP is 192.168.1.11, default gateway to 192.168.1.1
•Default weighing terminal IP set to 192.168.1.12. Data port 2102. Select “Proto 53”,
or “Proto 54” protocol, then send the B-TEK String for easy setup. When using these
protocols, the indicator must be set as server, the remote is client.
•The transmitting indicator IP address can be changed using the Devicer or Wagset
software.

Page | 14
Replacement Part Numbers
Part
Numbers
Description
841-100040
BT-470 4.7" LED ARRAY REMOTE DISPLAY w/VISOR, 3" POLE MNT
BRACKETS, & ANNUNCIATORS
841-100041
BT-470 4.7" LED ARRAY REMOTE DISPLAY w/ ANNUNCIATORS
841-100043
BT-470TL 4.7" LED ARRAY REMOTE DISPLAY w/VISOR, 3" POLE MNT
BRACKETS, ANNUNCIATORS, & TRAFFIC LIGHT
841-100044
BT-470TL 4.7" LED ARRAY REMOTE DISPLAY w/ ANNUNCIATORS, &
TRAFFIC LIGHT
841-500074
BT-470 4.7" VISOR
841-500083
BT-470TL VISOR
841-500075
BT-470 4.7" POLE MOUNT KIT
841-500076
2" POLE MOUNT BRACKETS (ORDER TWO PER SCOREBOARD)
841-500077
3" POLE MOUNT BRACKETS (ORDER TWO PER SCOREBOARD)
841-500078
4" POLE MOUNTBRACKETS (ORDER TWO PER SCOREBOARD)
841-500079
5" POLE MOUNTBRACKETS (ORDER TWO PER SCOREBOARD)
841-500080
BT-470 MAIN BOARD
1
841-500081
BT-470 DISPLAY BOARD
2
841-500082
BT-470 POWER SUPPLY BOARD
3
3
2
1
This manual suits for next models
2
Table of contents
Other BTEK Monitor manuals