Bticino 322032 User manual

1
322032
12
3
6
4
5
9
8
7
A C
B
A (mm) B (mm) C (mm)
125 325 44,5
D45 System
Description
Additional 16 call pushbuttons panel
D45 System additional 16 pushbuttons panel. Equipped with 16 backlighted call
pushbuttons and possibility to direct call to the porter switchboard. Setup key functions
via programming,phisical configurators insertion or through the dedicated software
supplied with the product. Flush mounting installation with dedicated box (supplied
with the product).
Related items
322030 10 pushbuttons colour video entrance panel
Technical data
Power supply: 30 Vdc
Stand by absorption: ≤ 5 mA @ 30 V
Max. operating absorption: ≤ 28 mA @ 30 V
Operating temperature: (-25) – (+55) °C
Protection index: IP54
Protection index against mechanical impact: IK07
Dimensional data
Legend
1. Call pushbuttons
2. Backlighted nameplates
3. Configurators socket
4. Mode jumper socket
5. Status jumper socket
6. RJ45 main entrance panel connection
7. RJ45 additional pushbuttons panel connection
8. Room number reset pushbutton
9. ISP : device software upgrade connector
Front view
Rear view
BT00767-a-EN 03/06/2013

2
322032
→702
→701
→604
→603
→602
→601
→504
→503
→502
→501
→404
→403
→402
→401
→304
→303
N
#I
N
#I F F I I
SCS RM
CF NA
Additional 16 call pushbuttons panel
Additional pushbuttons panel status setting
Configuration
Two different configuration ways available :
Configuration by inserting phisical configurators - WAY 1
Configuration by using SF2 software and PC connection - WAY 2
Pushbuttons panel have two status, one is work status, another is setting status.
In work status, pushbuttons panel can call internal unit and work with internal unit.
Pushbuttons panel usually is in this status.
In setting status, can’t call and work with internal unit,but can set room number or SCS
address of corresponding pushbutton.
After finished set, exit setting status by jumper insertion (NA).
By inserting jumper (NA), pushbuttons panel is in work status. By inserting jumper (CF),
pushbuttons panel is in setting status.
Call mode
D45systemhavetwocall modalities,one is roomnumber mode,another isSCS address
mode (direct call mode). In room number mode, internal unit can be set according to
the room number; visitor type room number in entrance panel to call resident.
Factory default is in room number mode.
In SCS address mode (direct call mode),internal unit can be set according to SCS address.
Visitor just type SCS address to call resident, for example just type 1.
For pushbuttons panel, must be defined each pushbutton math a room number or SCS
address.
Configuration define in setting status as for below table:
Configuration define in work status as for below table:
Configuration settings by inserting physical resistor configuration - WAY 1:
Factory default is room number.
See pushbutton corresponding room number as follows:
Setting of additional pushbuttons panel number:
Jumper select (NA) enter in work status - insering the jumper between (NA pins), NN
configurators indicates the additional pushbuttons panel number (range from 01 to 80).
Reset of factory default pushbutton correspondance:
device in stand by status - press and mantain for about 6 seconds the key located
on the back of the entrance panel until one long tone is heard. This indicates that the
reset has been successfully completed.
Example - set the additional pushbuttons panel number as 03:
while additional pushbuttons panel power supply is OFF, insert a jumper between NA
pins, put configurators 03 in NN sockets. Then put power supply ON, the entrance panel
will save the 03 number.
NOTE (A) : phisical configurator insertion has higher priority. If NO configurator inserted,
the device number is the last value we got by configurators or by SF2 software. Default
number is 01.
NOTE (B) : the additional pushbuttons panel number MUST BE the same as for the as-
sociated main entrance panel.
POSITION VALUE FOR CONFIGURATOR REMARKS
N 0 NN is 01(default)
When no jumper on“CF”
N 3
ROOM NUMBER MODE SCS ADDRESS MODE
#I#I maximum apartment quantity
per floor
Don’t use
FF floor number of corresponding
pushbutton
SCS address high digit of corre-
sponding pushbutton
II apartment number corresponding
pushbutton
SCS address low digit of
corresponding pushbutton
DEFINE
NN Entrance panel number
FF Don’t use
II Don’t use
BT00767-a-EN 03/06/2013

3
SCS RM CF NA
SCS RM CF NA
Configuration
Configuration by using SF2 Software and PC connection- WAY 2 :
This is the enhanced way to download the device configuration to additional pushbut-
tons panel previously created by using SF2 configuration software and a personal com-
puter. To transfer use the configuration hardware tool 323020 serial interface
WARNING : to ensure that the communication is successful, additional pushbut-
tons panel must be powered and NOT phisically configured.
323020
configuration
tool
BT00767-a-EN 03/06/2013
Room mode number
First select (CF) entering setting status, than select (RM) entering room number mode,
insert configurators, last press the pushbutton which you want to set in the front of the
panel until a long tone be heard. A long tone will indicates that room number has been
successfully completed.
Repeat configurators insertion to set all room number corresponding pushbutton.
After finished to set all room number, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 203 - number of aparments per floor = 06 :
- jumper select (CF) enter setting status, jumper select (RM) enter room number mode
- insert configurators 02 in FF sockets and configurators 03 in II sockets and insert con-
figurators 06 in #I #I
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (We cannot set
FF and II as 00).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
Setting of ROOM NUMBER or SCS ADDRESS for each pushbutton
POSITION VALUE FOR CONFIGURATOR
N 0
N 6
F 0
F 2
I 0
I 3
(SCS) - SCS address mode
(RM) - Room number mode
(CF) - Setting status
(NA) - Work status
POSITION VALUE FOR CONFIGURATOR
N
N
F 0
F 1
I 2
I 3
SCS address mode (direct call mode)
First, jumper select (CF) entering setting status, than jumper select (SCS) entering SCS
address mode. Insert configurators, last press the pushbutton which you want to set in
the front of panel until a long tone be heard. A long tone will indicates SCS address has
been successfully completed.
Repeat configurators insertion to set all SCS address corresponding pushbutton.
After finished to set all SCS address, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 0123:
- jumper select (CF) enter setting status, jumper select (CF) enter SCS address mode
- insert configurators 0123 in FFII sockets
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (Max. SCS
configuration address is 4000).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
Setting of porter switchboard call :
same procedure as for the SCS address mode setting but porter switchboard address is
fixed to 4000. Means that FFII must be set as 4000.