Additional 16 call pushbuttons panel
Additional pushbuttons panel status setting
Configuration
Two different configuration ways available :
Configuration by inserting phisical configurators - WAY 1
Configuration by using SF2 software and PC connection - WAY 2
Pushbuttons panel have two status, one is work status, another is setting status.
In work status, pushbuttons panel can call internal unit and work with internal unit.
Pushbuttons panel usually is in this status.
In setting status, can’t call and work with internal unit,but can set room number or SCS
address of corresponding pushbutton.
After finished set, exit setting status by jumper insertion (NA).
By inserting jumper (NA), pushbuttons panel is in work status. By inserting jumper (CF),
pushbuttons panel is in setting status.
Call mode
D45systemhavetwocall modalities,one is roomnumber mode,another isSCS address
mode (direct call mode). In room number mode, internal unit can be set according to
the room number; visitor type room number in entrance panel to call resident.
Factory default is in room number mode.
In SCS address mode (direct call mode),internal unit can be set according to SCS address.
Visitor just type SCS address to call resident, for example just type 1.
For pushbuttons panel, must be defined each pushbutton math a room number or SCS
address.
Configuration define in setting status as for below table:
Configuration define in work status as for below table:
Configuration settings by inserting physical resistor configuration - WAY 1:
Factory default is room number.
See pushbutton corresponding room number as follows:
Setting of additional pushbuttons panel number:
Jumper select (NA) enter in work status - insering the jumper between (NA pins), NN
configurators indicates the additional pushbuttons panel number (range from 01 to 80).
Reset of factory default pushbutton correspondance:
device in stand by status - press and mantain for about 6 seconds the key located
on the back of the entrance panel until one long tone is heard. This indicates that the
reset has been successfully completed.
Example - set the additional pushbuttons panel number as 03:
while additional pushbuttons panel power supply is OFF, insert a jumper between NA
pins, put configurators 03 in NN sockets. Then put power supply ON, the entrance panel
will save the 03 number.
NOTE (A) : phisical configurator insertion has higher priority. If NO configurator inserted,
the device number is the last value we got by configurators or by SF2 software. Default
number is 01.
NOTE (B) : the additional pushbuttons panel number MUST BE the same as for the as-
sociated main entrance panel.
POSITION VALUE FOR CONFIGURATOR REMARKS
N 0 NN is 01(default)
When no jumper on“CF”
N 3
ROOM NUMBER MODE SCS ADDRESS MODE
#I#I maximum apartment quantity
per floor
Don’t use
FF floor number of corresponding
pushbutton
SCS address high digit of corre-
sponding pushbutton
II apartment number corresponding
pushbutton
SCS address low digit of
corresponding pushbutton
DEFINE
NN Entrance panel number
FF Don’t use
II Don’t use