3
1 OPERATING INSTRUCTIONS............................................... 4
1.1 Denitionofterms/abbreviations ................................ 4
1.2 Symbols....................................................................... 4
2 INTENDED USE .................................................................... 5
2.1 Exapproval.................................................................. 5
3 GENERAL SAFETY INSTRUCTIONS.................................... 6
4 GENERAL NOTES................................................................. 7
4.1 Contactaddresses ...................................................... 7
4.2 Warranty ...................................................................... 7
4.3 Informationonline........................................................ 7
5 PRODUCT DESCRIPTION .................................................... 8
5.1 Structure...................................................................... 8
5.2 Solenoidwithcableoutlet........................................... 9
5.3 Solenoidwithterminalbox.......................................... 9
6 DEVICE USAGE CONDITIONS ........................................... 10
6.1 Specialconditions..................................................... 10
6.2 Operatingconditions................................................. 10
6.3 Operatingtemperaturerange .................................... 10
7 TECHNICAL DATA............................................................... 11
7.1 Safetyinstructions..................................................... 11
7.2 Conformity................................................................. 11
7.3 Standards .................................................................. 11
7.4 Labellingofsolenoidwithcableoutlet...................... 11
7.5 Labelofsolenoidwithterminalbox........................... 12
7.6 Typesofprotection.................................................... 13
7.7 Electricaldata............................................................ 14
8 ACCESSORIES ................................................................... 15
8.1 Cableglandforterminalboxes ................................. 15
8.2 Externalearthconnectionforterminalbox ............... 15
9 INSTALLATION AND DISASSEMBLY.................................. 16
9.1 Installingthevalve..................................................... 16
9.2 Electricalconnection ................................................. 17
9.3 Disassembly .............................................................. 18
10 START-UP............................................................................ 19
11 MAINTENANCE, REPAIRS, TROUBLESHOOTING............ 19
11.1 Maintenance.............................................................. 19
11.2 Repair ........................................................................ 19
11.3 Troubleshooting......................................................... 19
12 TRANSPORT, STORAGE, PACKAGING ............................. 20
Contents
english
EPS 16 ATEX 1072 X

4
Operating instructions
1 OPERATING INSTRUCTIONS
Theoperatinginstructionsdescribetheentirelifecycleofthedevice.
Keeptheseinstructionsinalocationwhichiseasilyaccessibleto
everyuserandmakethemavailable toevery new owner of the
device.
Important safety information!
▶Carefullyreadtheseinstructions.
▶Observeinparticularthesafetyinstructions,intendeduse
andoperatingconditions.
▶Personswhoworkonthedevicemustreadandunderstand
theseinstructions.
1.1 Denition of terms/abbreviations
Theterm‘device’usedintheseinstructionsalwaysreferstothe
TypeAC19solenoid.
Theabbreviation‘Ex’usedintheseinstructionsalways
standsfor“potentiallyexplosiveatmosphere”.
1.2 Symbols
Thefollowingsymbolsareusedintheseinstructions.
DANGER!
Warns of an immediate danger.
▶Failuretoobservetheseinstructionswillresultindeathor
seriousinjuries.
WARNING!
Warns of a potentially hazardous situation.
▶Failuretoobservetheseinstructionsmayresultinserious
injuriesordeath.
CAUTION!
Warns of a potential danger.
▶Failuretoobservetheseinstructionsmayresultinmoderate
orminorinjuries.
NOTE!
Warns of damage
Importanttipsandrecommendations.
Referstoinformationintheseoperatinginstructionsorin
otherdocumentation.
▶Designatesinstructionstoavoidadanger.
→Highlightsaprocedurewhichyoumustcarryout.
english
EPS 16 ATEX 1072 X

5
Intended use
2 INTENDED USE
Improper use of the AC19 solenoid may be dangerous to
people, nearby equipment and the environment.
The TypeAC19 solenoid is used to operate valves that
control gaseous or liquid media.
▶AvalveoperatedbytheAC19solenoid istobeusedexclusively
withthepermissiblemediaspeciedinthedatasheetandfor
useinexplosiongroupIIC,category2Gorexplosiongroup
IIIC,category2DandtemperatureclassT4(seedetailsonthe
typelabelfortheExarea).
▶Thesolenoidmayonlybeusedfortheapplicationsspecied
in chapter “6 Device usage conditions” and in connection
withtheexternaldevicesandcomponentsrecommendedand
permittedbyBürkert.
▶Thetypeofprotectionused is the Ex encapsulation‘m’for
coilswithcableconnections.
▶Thetypeofprotectionfortheoptionallyinstalledterminalboxes
is‘e’forgasand‘t’fordust.
▶Prerequisitesforsafeandtrouble-freeoperationofthesystem
arepropertransport,storageandinstallationaswellascareful
operationandmaintenance.Anyotheroradditionaluseisnot
consideredpartoftheintended use.Bürkertwillnotbeliable
foranydamageresultingfromthis.Theuseralonebearsthe
risk.
▶Onlyusethedeviceasintended.
2.1 Ex approval
The explosion protection approval is only valid if you use the
modulesandcomponentsauthorisedbyBürkertasdescribedin
theseoperatinginstructions.
TheAC19solenoidmaybeusedonlyincombinationwiththeaddi-
tionalcomponentsapprovedbyBürkert,otherwisetheexplosion
protection approval is terminated. In the event of unauthorised
changes to the device, modules or components, the explosion
protectionapprovalisalsoterminated.
ThefollowingECtypeapprovaltestcerticateandIECExcerti-
cateshavebeenissuedby:
BureauVeritas
ConsumerProducts
ServicesGermanyGmbH
BusinessparkA96
86842Türkheim,Germany
AC19solenoid: EPS16ATEX1072X
IECExEPS16.0030X
Terminalbox: PTB15ATEX1011U
IECExPTB15.0037U
Productionwillbeauditedby:CE102PTB
(PhysikalischTechnischeBunde-
sanstalt)
Bundesallee100
38116Braunschweig,Germany
You can find the EC type approval test certificate online at:
www.burkert.com
english
EPS 16 ATEX 1072 X

6
General safety instructions
3 GENERAL SAFETY
INSTRUCTIONS
Thesesafetyinstructionsdonottakeintoaccountany
unforeseencircumstancesandeventsthatoccurduringinstal-
lation,operationandmaintenance.
Theoperatorisresponsibleforobservingthelocation-specic
safetyregulations,alsowithreferencetopersonnel.
Risk of injury due to high pressure in the system or device.
▶Beforeworkingonthesystemordevice,switchothepressure
andventilateoremptythelines.
Risk of injury due to electric shock.
▶Beforeworkingonthesystemordevice,switchothepower
supplyandsecureitagainstreactivation.
▶Observetheapplicableaccidentpreventionandsafetyregu-
lationsforelectricaldevices.
Risk of burns or re from hot device surfaces due to prolonged
operation.
Thesolenoidcanbecomeveryhotduringcontinuousoperation.
▶Keepthedeviceawayfromhighlyammablesubstances
andmediaanddonottouchwithbarehands.
Risk of explosion.
Solenoidsandvalvebodiesformaclosedsystemafterinstal-
lation.Whenusedinapotentiallyexplosiveatmosphere,thereisa
riskofexplosionwhenthesystemisopenedintheoperatingstate.
▶Donotdismantleoropenthesystemduringoperation.
Risk of explosion due to electrostatic discharge.
Ifthereisasuddendischargeofelectrostaticallychargeddevices
orpersons,thereisariskofexplosionintheExarea.
▶Usesuitablemeasurestoensurethatelectrostaticchargescannot
occurintheExarea.
▶The device must not be used in areas with processes that
generateheavycharges,involveautomatedgrindingorcut-
ting,thesprayingofelectrons(e.g.nearelectrostaticpainting
equipment)orgeneratepneumaticallypropelleddust.
▶Cleanthedevicesurfacebygentlywipingitwithadampor
anti-staticclothonly.
To avoid the risk of explosions, the following must be observed
in the Ex area:
▶Informationabouttemperatureclass,ambienttemperature,
degreeofprotectionandvoltageonthetypelabelfortheEx
area.
▶Installation,operationandmaintenancemayonlybeper-
formedbyqualiedpersonnel.
▶Observe applicable safety regulations (also national safety
regulations) as well as the general rules for the technology
duringsetupandoperation.
english
EPS 16 ATEX 1072 X

7
General notes
▶Repairsmaybecarriedoutbythemanufactureronly.
▶Do not subject the device to mechanical and/or thermal
stresseswhichexceedthe limits describedintheoperating
instructions.
▶Theterminalboxmayonlybeopenedwhenthepoweriso.
General hazardous situations.
Topreventinjuries,ensurethatyou:
▶Securethedeviceagainstunintentionalactivation.
▶Notetheowdirectionwheninstalling.
▶Followinganinterruptioninthepowersupply,ensurethatthe
processisrestartedinacontrolledmanner.
▶Donotusethedeviceasaleverwhenscrewingthevalveinto
theline.
4 GENERAL NOTES
4.1 Contact addresses
Germany
BürkertFluidControlSystems
SalesCentre
Christian-Bürkert-Str.13-17
D-74653Ingelngen
Tel.+49(0)7940-1091111
Fax+49(0)7940-1091448
E-mail:[email protected]
International
Thecontact addressescan be found on theback pages ofthe
printedoperatinginstructions.
Theyarealsoavailableonlineat:www.burkert.com
4.2 Warranty
ApreconditionforthewarrantyisthattheAC19solenoidisusedas
intendedinconsiderationofthespeciedapplicationconditions.
4.3 Information online
OperatinginstructionsanddatasheetsforBürkertproducts can
befoundonlineat:www.burkert.com
english
EPS 16 ATEX 1072 X

8
Product description
5 PRODUCT DESCRIPTION
5.1 Structure
Components of the
AC19 solenoid with
cable outlet:
Retainingplate
Connectionline
Components of
the valve:
Nut
Coreguidetube
Valvebodywith
portconnection
Coilhousing
Unionnut
Fig. 1: Type AC19 solenoid with cable outlet
Valvebodywith
portconnection
Coreguidetube
Nut
Components of
the valve:
Components of the
AC19 solenoid with
terminal box:
Coilhousing
Retainingplate
Terminalbox
Screw
Springlockwasher
Lockingscrew
Flatwasher
Ringterminalwith
cable
Fig. 2: Type AC19 solenoid with terminal box
english
EPS 16 ATEX 1072 X

9
Product description
5.2 Solenoid with cable outlet
TheTypeAC19solenoidisanelectromagneticvalveactuatorfor
various Bürkert valves. As a so-called central screwed coil it is
100%separatefromthevalve.Thevalveitselfisaclosedsystem
evenwhenthecoilisremoved.
Thesolenoidconsistsof:
• coilwinding,
• coilhousing(madeofepoxide),
• electricalconnectioncable,
• controlelectronics.
Actuationispossiblewithalternatingordirectcurrentduetothe
integratedbridgerectier.Aversionwithelectronicpowerswitching
toreducethepowerconsumptionintheoperatingstateisoptionally
available.
Thecoilisplacedoverthecoreguidetubeofthevalveandfastened
withanut.Itispositivelysecuredagainstrotationtowardthevalve.
Theoutletoftheelectricalconnectionlineisperpendiculartothe
coilaxis.Thecableisrmlyintegratedintothecoil.Theunionnut
isnotintendedtoberemoved.
Themetal valve components arebroughtintoelectrical contact
withthecoilattheinterfacebetweenthecoilandthevalve.The
metalcomponentsmustbeearthedviatheprotectiveconductor
ontheconnectionline.
5.3 Solenoid with terminal box
The solenoid setup is identical to the description under “5.2”,
buthereaterminalboxisadditionallybuiltin(see“Fig.2”).The
terminal box is certified by EU type approval test certificate
PTB15ATEX1011UorIECExPTB15.0037U.
Thecableoutletdirectioncanbeselectedbasedontheordering
information.Thecableoutletdirectioncanbealteredlater,buta
specialtoolis needed for that1). Aconnection set for additional
potentialequalisation is optionally included,seetheinformation
inchapter“8.2”.
1) Get in touch with your assigned Bürkert contact person
english
EPS 16 ATEX 1072 X

10
Device usage conditions
6 DEVICE USAGE CONDITIONS
6.1 Special conditions
6.1.1 Avoiding electrostatic charge
WARNING!
Hazard due to electrostatic discharge.
Ifthereisasuddendischargeofelectrostaticallycharged
devicesorpersons,thereisariskofexplosionintheExarea.
▶Use suitable measures to ensure that electrostatic charges
cannotoccurintheExarea.
▶The device must not be used in areas with processes that
generateheavycharges,involveautomatedgrindingorcut-
ting,thesprayingofelectrons(e.g.nearelectrostaticpainting
equipment),orgeneratepneumaticallypropelleddust.
▶Cleanthedevicesurfacebygentlywipingitwithadampor
anti-staticclothonly.
6.1.2 Block installation
The AC19 coil is fundamentally designed for single installation.
Withblockinstallation,itisessentialthattheuserensuresthatthe
permittedambienttemperatureisnotexceededduetoreciprocal
heating.
6.2 Operating conditions
Thevalvefullsacoolingfunctionforthesolenoid.
Thesolenoidmustnotbeoperatedwithoutavalve.Thevalve
bodymustmeetthefollowingprerequisites:
• Material
Metal(brass,aluminium,stainlesssteel)orpolyamide
• Minimumdimensions
55mmx36mmx30mm
Alargervalvebodywithbetterthermalconductivitymaybeused
atanytime.
6.3 Operating temperature range
Pay attention to the operating temperature range for each type
listedintheelectricaldata.
english
EPS 16 ATEX 1072 X

11
Technical data
7 TECHNICAL DATA
7.1 Safety instructions
DANGER!
Risk of explosion.
Ifthetechnicalsafetyinformationandvalueslistedonthetype
labelarenotobservedandcompliedwith,dangeroussituations
couldoccur.
▶Observethedegreeofprotectionandtemperatureclassfor
operatingthedevice.
Exceeding the voltage stated on the type label is a technical
safetyriskthatcancausethedevicetooverheat.
▶Donotconnectthedevicetovoltagehigherthanwhatisspec-
iedonthetypelabel.
7.2 Conformity
TheTypeAC19solenoidconformstotheEUDirectivesasperthe
EUDeclarationofConformity.
7.3 Standards
TheappliedstandardsusedtoverifycompliancewiththeEUDirec-
tivescanbefoundintheEUtypeexaminationcerticateand/or
theEUDeclarationofConformity.
7.4 Labelling of solenoid with cable
outlet
Typelabelwith
detailsofvalve
AC19 solenoid with example valve and
the position type labels:
Typelabelwithdetailsof
AC19solenoid
1
2
3
4
5
6
8
7
9
10
Fig. 3: Location and description of the Ex type label
english
EPS 16 ATEX 1072 X

12
Technical data
Legend:
Position Description
1ATEX,certicateauthorandcerticatenumber
2ATEX,identicationoftheExprotection
3IECEx,certicateauthorandcerticatenumber
4IECEx,identicationoftheExprotection
5TypelabelwithExcode
6Nominalvoltage,nominalpower
7Ambienttemperaturerange
8Serialnumber
9Dateofmanufacture
10 Identicationnumber
7.5 Label of solenoid with terminal box
NOTE!
Thetypeofprotectionchangeswhentheterminalboxisattached.
AC19 solenoid with
terminal box with
example valve and the type label
positions:
1
2
3
4
5
6
7
8
9
10
Fig. 4: Location and description of the Ex type labels
english
EPS 16 ATEX 1072 X

13
Technical data
Legend:
Position Description
1ATEX,certicateauthorandcerticatenumber
2ATEX,identicationoftheExprotection
3IECEx,certicateauthorandcerticatenumber
4IECEx,identicationoftheExprotection
5TypelabelwithExcode
6Nominalvoltage,nominalpower
7Ambienttemperaturerange
8Serialnumber
9Dateofmanufacture
10 Identicationnumber
7.6 Types of protection
TheExlabelindicatesthetypesofprotectionofeachcomponent
used.
Variant Ex labelling Internal code
ATEX
Cable
outlet
II2GExmbIICT4Gb
II2DExmbIIICT130°CDb
JJ04+JWxx2)
+PX38
Terminal
box
II2GExebmbIICT4Gb
II2DExmbtbIIICT130°CDb
JA13+PX38
IECEx
Cable
outlet
ExmbIICT4Gb
ExmbIIICT130°CDb
JJ04+JWxx2)
+PX38
Terminal
box
ExebmbIICT4Gb
ExmbtbIIICT130°CDb
JA13+PX38
2) Varying cable lengths
english
EPS 16 ATEX 1072 X

14
Technical data
7.7 Electrical data
Version Bridgerectier Powerswitching
Internalcode CZ24 CZ05
Nominal
voltage/
frequency
24VDC/50,60Hz
110VDC/50,60Hz
120V/60Hz
230VDC/50,60Hz
240V/60Hz
24VDC/50,60Hz
110V/50,60Hz
120V/60Hz
230V/50,60Hz
240V/60Hz
Nominalpower 15W 44W
Reduced
nominalpower
n/a 6.5W
Ambienttem-
peraturerange
–40...+55°C –40...+70°C
Temperature
class
T4/130°C
Max.switching
frequency
n/a 30/min
Min.cur-
rentlessbreak
n/a 1s
Operatingmode
(accordingto
DINVDE0580)
Continuousoperation
Intermittentoperation
Short-termoperation
7.7.1 Electrical connection
Technicaldataofthecable:
Material3): Polyolen
Operatingtemperature
range3): –55...+145°Cwithxedinstallation
Minimumbendingradius3): 4xexternaldiameterwithxed
installation
Externaldiameter3): 6.2mm
Setup/function: 3xcopperstrands,0.5mm²/LNPE
Halogen-freeaccordingtoIEC60754-1
Variants Internalcode
Permanentlyinstalledcable JJ04+JWxx4)
TerminalboxwithinternalthreadM20x1.5 JA13
3) Details according to the manufacturer
4) Varying cable lengths
english
EPS 16 ATEX 1072 X

15
Accessories
8 ACCESSORIES
8.1 Cable gland for terminal boxes
Suitablecableglandsareavailableforusewiththeterminalbox.
Plasticcableglandisincludedinthescopeofdeliveryof
thevalve.Brasscableglandmustbeorderedseparately.
Cableglandsfromothermanufacturerscanalsobeusedif
thecableglandsaredesignedforthelocationandcorrect
installation.Pleasenotethattheoperatingtemperatureof
thecableglandmustbemin.15Kabovethemax.ambient
temperature.
Material Clamping
area [mm]
Operating
temperature
Order
number
Certif-
icate No.
Plastic 7–13 –40...+75°C 773277 5)
Brass 6–13 773278 6)
Material IP
protection
Dust labelling Gas labelling
Plastic IP66 II2DExtbIIICDb II2GExeIICGb
Brass
5) PTB13ATEX1015X; IECExPTB13.00034X
6) PTB04ATEX1112X; IECExPTB13.00027X
8.2 External earth connection for
terminal box
Connectionterminalsareprovidedforexternalearthconnection
onsolenoidswithterminalboxes.
Ifitisnotpossibletoconnectthepotentialequalisationviapipeline
ortheuseofaplasticvalve,thereisthepossibilityofestablishingthe
connectionviatheexternalearthconnection.Theuseistherefore
optionalandistheresponsibilityoftheoperator.
Theconnectioncapacityoftheringterminalis4–6mm2.The
connectionisestablishedasshownin“Fig.6”.
english
EPS 16 ATEX 1072 X

16
Installation and disassembly
9 INSTALLATION AND
DISASSEMBLY
DANGER!
Risk of injury due to high pressure in the system or device.
▶Beforeworkingonthesystemordevice,switchothepressure
andventilateoremptythelines.
Risk of injury due to electric shock.
▶Beforeworkingonthesystemordevice,switchothepower
supplyandsecureagainstreactivation.
▶Observetheapplicableaccidentpreventionandsafetyregu-
lationsforelectricaldevices.
Risk of burns or re from hot device surfaces due to prolonged
operation.
▶Keepthedeviceawayfromhighlyammablesubstances
andmediaanddonottouchwithbarehands.
Danger of short circuit due to damaged connection cables.
▶Coilconnectioncablesmustbeattachedrmlyandprotected
fromdamage.
Risk of explosion.
Solenoidsandvalvebodiesformaclosedsystemafterinstallation.
WhenusedinanExarea,thereisariskofexplosionwhenthe
systemisopenedintheoperatingstate.
▶Donotdismantleoropenthesystemduringoperation.
DANGER!
Risk of explosion due to electrostatic discharge.
Ifthereisasuddendischargeofelectrostaticallychargeddevices
orpersons,thereisariskofexplosionintheExarea.
▶Usesuitablemeasurestoensurethatelectrostaticcharges
cannotoccurintheExarea.
▶The device must not be used in areas with processes that
generateheavycharges,involveautomatedgrindingorcut-
ting,thesprayingofelectrons(e.g.nearelectrostaticpainting
equipment),orgeneratepneumaticallypropelleddust.
▶Cleanthesurfaceofthesolenoidvalvedevicebygentlywiping
itwithadamporanti-staticclothonly.
WARNING!
Risk of injury due to improper installation.
▶Installationmayonlybecarriedoutbytrainedtechnicians
withtheappropriatetools.
▶Securethesystemagainstunintentionalactivation.
▶Followinginstallation,ensureacontrolledrestart.
9.1 Installing the valve
Anexactdescriptionoftheinstallationcanbefoundin
theoperatinginstructionsforthevalveinquestionand/or
onlineat:www.buerkert.de
english
EPS 16 ATEX 1072 X

17
Installation and disassembly
9.2 Electrical connection
DANGER!
Risk of injury due to electric shock.
▶Beforereachingintothesystem,switchothepowersupply
andsecureagainstreactivation.
▶Observetheapplicableaccidentpreventionandsafetyregu-
lationsforelectricaldevices.
Ifthereisnoelectricalcontactbetweenthemetalvalvecom-
ponentsandtheprotectiveconductorofthecoil,thereisarisk
ofelectricshock.
▶Alwaysconnectprotectiveconductor.
▶Checkelectricalcontinuitybetweentheprotectiveconductor
ofthecoilandthecoreguidetubeofthevalve.
With solenoids with terminal boxes, you must also ensure
that you:
▶Onlyinsertpermanentcablesandlines.
▶Usesuitablecableandwiringguides(seechapter“8”).Pay
attentiontotheprovisionsintheoperatinginstructionsincluded.
▶Intheterminalboxes,onlyconnectwireswithterminalconnec-
tionsmeasuringbetween0.5mm2and2.5mm2.
▶Tightentheterminalscrewswith0.25Nm.
▶Lockhousinglidproperly.Tightenlockingscrewwith2Nm.
▶Checktheconsistencyoftheprotectiveearthconnection.
▶Onlyopenthehousinglidwhenthepoweriso.
▶Thetemperatureresistanceofthecablemustbemin.15K
abovethemax.ambienttemperature.
▶Usecableendsleevesonexiblelines.
▶Theexternalearthconnectionterminals,suppliedinabag
andgluedintothehousinglid,mustberemovedwhen
installingthedevice.
9.2.1 Solenoids with cable outlet
TheconnectioncableiscastwiththeTypeAC19
solenoidandcannotberemoved.
Observethevoltagelistedonthetypelabel.
Wire colour Pin assignment
Green-yellow Protectiveconductor
Black Phase/positivepole(+)
Black Neutralconductor/negative
pole(–)
english
EPS 16 ATEX 1072 X

18
Installation and disassembly
9.2.2 Solenoids with terminal box
Black
Black
Green-
yellow
Position Pin assignment of the
supply line
Protectiveconductor
Neutralconductor/neg-
ativepole(–)
Phase/positivepole(+)
Fig. 5: Terminal box
Screw
Springlockwasher
Flatwasher
Flatwasher
Ringterminalwithcable
Fig. 6: Connection of external potential equalisation
9.3 Disassembly
DANGER!
Risk of injury due to high pressure in the system or device.
▶Beforeworkingonthesystemordevice,switchothepressure
andventilate/emptythelines.
Risk of injury due to electric shock.
▶Beforeworkingonthesystemordevice,switchothepower
supplyandsecureitagainstreactivation.
▶Observetheapplicableaccidentpreventionandsafetyregu-
lationsforelectricaldevices.
WARNING!
Risk of injury due to improper disassembly.
▶Disassembly must be performed only by trained personnel
usingsuitabletools.
Risk of injury due to medium leaking out of leaky
connections.
▶Carefullysealconnectionlines.
→Disconnectelectricalconnection.
→Disconnectvalvebodyfromthepipeline.
NOTE!
Malfunctions due to contamination!
•Fornewinstallations,removeoldPTFEtapefromtheconnec-
tions.Taperesiduemustnotgetintothepipeline.
english
EPS 16 ATEX 1072 X

19
Start-up
10 START-UP
WARNING!
Risk of injury due to improper operation.
Improperoperationmayresultininjuriesaswellasdamageto
thedeviceandtheareaaroundit.
▶Beforestart-up,ensurethattheoperatingpersonnelare
awareofandhavecompletelyunderstoodthecontentsof
theoperatinginstructions.
▶Thesafetyinstructionsmustbefollowedandthedeviceused
onlyasintended.
▶Onlyadequatelytrainedpersonnelmaystartupthesystem
ordevice.
Before start-up, ensure that
→thedevicehasbeeninstalledcorrectly,
→theconnectionhasbeenproperlyexecuted,
→thedeviceisnotdamaged,
→allscrewshavebeentightened.
11 MAINTENANCE, REPAIRS,
TROUBLESHOOTING
11.1 Maintenance
TheAC19solenoidismaintenance-freeiftheoperatingconditions
describedintheinstructionsareobserved.
11.2 Repair
DANGER!
Risk of injury due to improper repair.
ThesafetyandfunctionoftheAC19solenoidandtheaccompa-
nyingsolenoidvalveareonlyensuredafterarepairiftherepairs
weredonebythemanufacturer.
▶Onlyhavethedevicerepairedbythemanufacturer.
11.3 Troubleshooting
Inthecaseofmalfunction,ensurethat
→thedevicehasbeeninstalledcorrectly,
→theconnectionhasbeenproperlyexecuted,
→thedeviceisnotdamaged,
→voltageandpressurehavebeenapplied,
→thepipelinesarefree,
→allscrewshavebeentightened.
english
EPS 16 ATEX 1072 X

20
Transport, storage, packaging
12 TRANSPORT, STORAGE,
PACKAGING
NOTE!
Transport damage.
Inadequatelyprotecteddevicesmaybedamagedduring
transport.
•Protectthedeviceagainstmoistureanddirtinshock-re-
sistantpackagingduringtransport.
•Avoidexceedingordroppingbelowthepermittedstorage
temperature.
Incorrect storage may damage the device.
•Storethedeviceinadryanddust-freelocation.
•Storagetemperature:–40°C...+80°C.
Damage to the environment caused by device parts contam-
inated with media.
•Disposeofthedeviceandpackaginginanenvironmentally
friendlymanner.
•Observeapplicabledisposalandenvironmentalregulations.
english
EPS 16 ATEX 1072 X
This manual suits for next models
5
Table of contents
Popular Servo Drive manuals by other brands

LinMot
LinMot E1400-GP-QN installation guide

SMC Corporation
SMC Corporation LEFS25 Operation manual

Rockwell Automation
Rockwell Automation Allen-Bradley Ultra3000 manual

Moons'
Moons' Applied Motion Products SSDC-ECX-H Hardware manual

Siemens
Siemens SIMOTICS S-1FL6 operating instructions

Baldor
Baldor VS1SD Installation & operating manual

Mitsubishi
Mitsubishi MR-JE series instruction manual

Control Techniques
Control Techniques Unidrive Regen installation guide

Rockwell Automation
Rockwell Automation Allen-Bradley Kinetix 7000 user manual

YASKAWA
YASKAWA E-II Series user manual

Technosoft
Technosoft iPOS3602 BX-CAN Technical reference

Siemens
Siemens SINAMICS S120 Equipment manual