16
8. BURNER OPERATING
8.1. Ignion.
Aer the start up of the burner from
the control panel, the main pellet auger
conveys certain amount of fuel from the
pellet hopper to the burner. This specic
amount of pellets is set by the installer
and depends on the fuel characteriscs.
The fed-in quanty of pellets is conveyed
from the auger conveyor built in the
burner to the combuson chamber
where it is being ignited using hot air.
8.2.Burning.
The burning process takes place in
the combuson chamber and, aer
it has been fed into the combuson
chamber, the fuel is then transported
from the internal auger conveyor to
the combuson chamber in porons.
This allows for constant and opmal
burning rate of the fuel . Flame intensity
is monitored by a photosensor which
monitors the burning and feeds data
into the control unit which enables the
starng or stopping of the combuson
process, if necessary. The output of the
burner is determined by the intervals
preset on the control panel taking into
account the heang value, size and
density of the pellets.
8.3. Automaccleaningsystem.
The “Pell” pellet burner is equipped with
innovave automac cleaning system
for the combuson chamber. Thanks to
a powerful cleaning motor built in the
burner body, air is being blown in at high
speed and rate thus removing all residues
– ash, noncombusble inclusions, etc.
built up into the combuson chamber
of the boiler. These automac cleaning
cycles last several seconds and can be
addionally adjusted as well as their
repeat rate depending on the load of the
burner.
8.4. Installer prescripons regarding
burnerservicingandmaintenance
Before the heang season it is mandatory
to check up and clean the burner and its
components.
It is mandatory to clean up the
combuson chamber of burner using the
scraper brush from the maintenance kit.
In case of combuson chamber orices
clogged by non-combusve material,
those should be released using a bodkin.
Clean thoroughly the inner combuson
chamber using the scraper brush to
remove all deposits on the metal surface.
Use a vacuum cleaner to remove all sand
and ashes from inside the combuson
chamber. Check integrity of gasket
between outer combuson chamber and
closing hatch, replace if compromised.
It is mandatory to clean dust o main
fanandcontrollerboard
8.5. Important recommendaons for
long-lasngandcorrectoperaonofthe
boiler
- For assembly and installaon of the
burner follow the requirements in this
manual.
- Use only recommended in this manual
fuel.
- Disassemble the burner from the boiler
body before clean it. Depending on fuel
and burner sengs, clean the pellet
burner once a month.
- User`s training for operaon and
maintenance of burner is performed by
an authorized installer or service shop.
Failure to observe the
installation and operating
requirements described in the
manualandtheservicebooklet
voidsthewarranty.