C.R. Laurence C9ASA User manual

crlaurence.com • Phone Toll Free (800) 421-6144 • Fax Toll Free (800) 458-7496
AVD3992-10/13
C.R. LAURENCE CO., INC.
FOR MODELS: C9ASA C9ABL
E
H
G
J
L
A
D
F
EXTE IO UNIT B
INSTALLATION INSTRUCTIONS FOR COUNTER-TOP COMMUNICATORS
1. Unpack the Interior Unit (A) and Exterior Unit (B). Check to be sure all parts shown on this diagram are included.
2. Use the supplied Security Torx Bit (C) to remove the screws in the lower back corners (D) of both the Interior and
Exterior Units.
3. emove the Mounting Plates (E) from the underside of the Interior and Exterior Units.
4. Position the Mounting Plates on the interior and exterior side of the glass or other partition. The Mounting Plates
are typically installed flush against the partition. Depending on the condition of the partition, the optional rubber
bumpers (F) can be applied to the back of the Mounting Plates if needed.
5. Using a pen or a center punch, mark the counter for the locations of the Mounting Screws (G) and the access holes for
the 2-wire Power Cable (H) and the 5-wire Communication Cable (I). The interior side needs access for both cables.
The exterior side only needs access for the Communication Cable (I).
6. Move the Mounting Plates and pre-drill the counter for the supplied screws. If the counter is made of a solid material
such as granite, drill for installing the optional Screw Anchors (J). Also, drill access holes for the Power Cable (H) and
the Communication Cable (I).
7. One end of the Communication Cable (I) has the five inner wires exposed. Keep 9" - 12" (227mm -305mm) of this end on
the interior unit side, and feed the Communication Cable through its access hole. On the exterior unit side, cut off excess
cable so that about 9" - 12" (227mm -305mm) projects from the hole. Strip the outer gray insulation sheath back to
expose approximately 1-1/2" (38mm) of the five inner wires. Peel the shielding foil away as well. Do not cut the
silver-colored shielding wire. The remaining four wires each have a different color insulation sheath. Strip each sheath
back to expose approximately 1/8" – 3/16" (3mm - 5mm) of bare wire.
M
N
I
C
SPEAKE
K
INTE IO UNIT
FF
F
E
J
D
G
O
TR
P
S
Q
X
D

crlaurence.com • Phone Toll Free (800) 421-6144 • Fax Toll Free (800) 458-7496
SET UP INSTRUCTIONS
1. emove the boom microphone socket cover (M) and install the Boom Microphone (N) by plugging into the socket (O) on the Interior
Unit. etain the socket cover for future use.
2. Confirm that the Communicator starts by pressing the POWE /MUTE button (P). The POWE /MUTE indicator (Q)
should now be illuminated. If the unit does not start, check the wiring and wall outlet.
3. Verify that the Communicator works by talking into the Interior Boom Microphone (N) and the Exterior Microphone (X).
Do not speak into the Interior Boom Microphone from closer than two inches (51 mm). See VOLUME adjustment notes below.
CONTROLS
POWER/MUTE - When the Communicator is off, the POWE /MUTE indicator (Q) will not be lit.
Pushing the POWE /MUTE button (P) will start the Communicator. The POWE /MUTE indicator (Q) will be Green when the
Communicator is ON.
Press again to cycle between ON and MUTE. In the MUTE mode the POWE /MUTE indicator (Q) will be flashing ed.
Depressing the switch for two seconds will turn the unit OFF. The POWE /MUTE indicator (Q) will not be lit when the Communicator is OFF.
VOLUME – To adjust the interior and exterior speaker volume, press the INTE IO volume rocker switch (R) or EXTE IO volume
rocker switch (S). Pressing the rocker switch up will increase the volume, and pressing the switch down will decrease the volume. Try
to keep the volume as low as needed to effectively communicate.
8. One end of the Power Cable (H) has the two inner wires exposed. Keep 9" - 12" (227mm -305mm) of this end on the inner unit
side and feed the Power Cable through its access hole toward where the unit will be plugged into a wall outlet. Cut off an
appropriate amount of excess Power Cable, considering the length of the cable attached to the Transformer (L). Strip the outer
gray insulation sheath back to expose approximately 1-1/2" (38mm) of the two inner wires. Strip back the red and black insulation
from the inner two wires to expose approximately 1/8" – 3/16" (3mm - 5mm) of bare wire.
9 . Install the wires into the terminals on the back of the Interior and Exterior Units. The back of each unit has a color-coded label to
indicate which wire goes into which terminal. Firmly tighten each screw to hold the wires in the terminal. Lightly tug on each wire
to make sure that it is held securely in place.
10. Secure the Mounting Plates (E) to the counter using the supplied Mounting Screws (G). Use the supplied Screw Anchors (J)
if appropriate for the counter material.
11. Install the Interior and Exterior Units onto the Mounting Plates. Feed loose cable back into the access holes. Secure the units to
the plates using the Security Torx Screws from Step 2.
12. Install the Power Adapter (K) onto the free end of the Power Cable. Make sure that the red wire (positive) is inserted into the
terminal under the (+) symbol and the black wire (negative) is inserted under the (-) symbol. Tighten the terminal screws down
on the wires and lightly tug on the wires to make sure they are held securely in place.
13. Plug the Transformer/Power Supply (L) into a normal wall outlet and insert its jack into the Power Adapter (K).
The T ansfo me can be used fo both 115V and 240V outlets ( ange of 100V to 240V). Optional plug adapte s a e available
fo Eu ope (EUSS412) and Aust alia (AUWSS416).