CamTron CTNC-5353H Manual

H.264 IP Camera Cywatch
1
INFORMATION - This equipment has been tested and found to comply with
limits for a Class A digital device, pursuant to part 15 of the FCC Rules & CE Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
◆
Do NOT use power sources other than those specified.
◆
Do NOT expose this appliance to rain or moisture.
This installation should be made by a qualified service person and
should conform to all local codes.
The lightning flash with an arrowhead symbol, within an equilateral
triangle is intended to alert the user to the presence of uninsulated
dangerous voltage within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert
the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the appliance.
WARNING - Changes or modifications not expressly approved by the
manufacturer could void the user's authority to operate the equipment.
CAUTION : To prevent electric shock and risk of fire hazards:

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
2
3
■Contents
Features
Precautions
Names and Functions of Parts
Installation
■Front View
■Bottom View
■Rear View
04
06
09
12
09
10
11
■Lens
ㆍUsing the auto iris
ㆍUsing a C/CS mount lens
■Connecting to a monitor
■Connecting to power
12
15
15
Components 08
How to Use the Camera
Troubleshooting
■Function Menu Structure
■How to Set up the Functions
ㆍLENS
ㆍSHUTTER
ㆍWHITE BALANCE
ㆍBLC (Back Light Compensation)
ㆍAGC (Automatic Gain Control)
ㆍDNR (Digital Noise Reduction)
ㆍSENS UP (Low illuminance)
ㆍCAM ID
ㆍEXIT
16
34
16
17
18
20
21
22
23
24
24
26
33
ㆍSPECIAL 27
Specifications 35

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
4
5
■Features Warning ■
D.Zoom
The camera has a function of 8x digital zoom.
Horizontal Resolution of 540 TV
Lines
Clear image quality has been achieved by
employing a SONY CCD with 410,000
(effective) pixels, which provides a horizontal
resolution of 540 TV lines.
DAY & NIGHT
This camera has a function that automatically
selects the mode that is appropriate for daytime
or night-time conditions. The COLOR mode
operates in daytime conditions to provide
optimum colors, and BW mode operates in
nighttime conditions to enhance the definition
of the image.
Electronic IRIS
The electronic IRIS function enables continuous
automatic control of the shutter between
1/50(60)~1/120,000 seconds.
High Sensitivity
The built-in high sensitivity SONY COLOR
CCD enables a clear image even in
0.3Lux(0.1Lux B/W) or as low as 0.002Lux
with SENS-UP.
PRIVACY Function
The PRIVACY function conceals the areas not
required to appear on the image.
DNR (Digital Noise Reduction)
The amount of low illuminance noise has been
significantly reduced, and the signal-to-noise
ratio (S/N ratio) as well as horizontal resolution
have been improved, resulting in clear and sharp
images displayed even in low light.
Controlled by OSD Menu
The camera functions are controlled by selecting
text displayed on the monitor screen.
Additional Functions
SENS-UP, MOTION DETECTION, MIRROR,
SHARPNESS and SYNC (INT/LL) functions are
also available.
Video
- High-quality compression algorithm, H.264
-
Compression in various resolution: CIF, Half-D1, D1
-
Wide range of video transmission rate: 32kbps~4Mbps
- Various transmission mode: CBR, VBR
- Motion detection
Audio
Multi-transmission mode: Uni-direction (CTNC-5353H ->
Client PC or Decoder, Client PC or Decoder ->
CTNC-5353H), Bi-direction
Network
- Static IP and Dynamic IP(DHCP,)
- One to one and one to many connection
- Multicasting
-
Automatic transmit rate control according to
network condition
The camera requires periodic inspection.
Contact an authorised technician to carry out the inspection.
Stop using your camera when you find it malfunctioning.
If the camera emits smoke or is unusually hot for a long period,
a fire may be caused.
Do not Install the camera on a surface that can not support it.
If the camera is installed on an inappropriate surface, it may fall
and cause injury.
Do not hold plug with wet hands.
It could cause an electric shock.
Do not dis-assemble the camera.
It may result in an electric shock or other hazards.
Do not use the camera close to a gas or oil leak.
It may result in a fire or other hazards.

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
6
7
■Precautions
Do not install the camera in
extreme temperature conditions.
Do not install the camera under
unstable lighting conditions.
Do not touch the front lens of the
camera.
Only use the camera under conditions
where temperatures are between
-10˚C and +50˚C. Be especially
careful to provide ventilation when
operating under high temperatures.
It can cause the image quality to be
poor.
Severe lighting change or flicker can
cause the camera to work improperly.
This is one of the most important parts of
the camera. Be careful not to leave
fingerprints on the lens cover.
Do not install or use the camera in an
environment where the humidity is high.
ㆍIf the camera is exposed to spotlight or an object reflecting strong light,
smear or blooming may occur.
ㆍPlease check the power supply satisfies the normal specification before
connecting the camera.
It can cause malfunctions to occur.
If it gets wet, wipe it dry immediately.
Liquids can contain minerals that
corrode the electronic components.
If exposed to radioactivity the CCD
will fail.
It can damage the CCD.
Do not drop the camera and protect
it from physical shocks.
Do not expose the camera to rain
or spill beverage on it.
Do not expose the camera to
radioactivity.
Never keep the camera pointed
directly at strong light.

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
8
9
■Components
Names and Functions of Parts ■
2.
AUTO IRIS LENS CONNECTION PLUG
3. L-WRENCH
4. C-MOUNT ADAPTOR
Front
①Lens protection cap
Cover the lens when not using it.
②CS-Mount lens adaptor
Attach the CS-Mount lens here.
③Back Focus clamp screw
Loosen the clamp screw with a screwdriver before adjusting the Back
Focal length.
1. COLOR BOX CAMERA
① ② ③


H.264 IP Camera Cywatch H.264 IP Camera Cywatch
12
13
■Installation
Installation ■
Lenses are sold separately. Lenses such as auto iris lens, CS-Mount lens
and C-Mount lens can be used.
1. Peel off about 8mm of the outer skin of the auto iris lens cable.
2. Peel off about 2mm of the outer skin of the insulated conductor inside the
lens cable.
■
Lens
Note
ㆍUse of the DC auto iris lens is recommended to achieve the best
results for operating this product effectively.
ㆍKeep the lens clean.
ㆍAny foreign objects and fingermarks on the lens can cause inferior
image quality in low light level conditions.
When using an auto iris lens
3. Remove the cover of the auto iris lens connection plug and solder the
lens cable to the connector pin in the plug.
4. Replace the auto iris lens connection plug cover and take off the lens
protection cap, and then attach the auto iris lens to the camera by
screwing it in clockwise.
5. Insert the connection plug that is connected to the auto iris lens cable into
the auto lens connector, which is located on the side of the camera.
Pin No. LENS
DC
No.1 Pin Damping-
No.2 Pin Damping+
No.3 Pin Drive+
No.4 Pin Dreve-

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
14
15
■Installation
Take off the lens protection cap and attach
the CS-Mount lens to the camera by screwing it in
clockwise.
Note
ㆍUse the specified lens connection parts as shown in the picture below.
The use of the wrong sized parts may cause damage
to the inside of the camera or result in poor fitting.
ㆍUse of a lens which is too heavy affects the balance
of the camera and may cause a malfunction. Please
use a lens that weighs less than 450g.
ㆍSelect Av mode if possible when adjusting
the automatic light control (ALC) of an auto lens.
Use of PK mode may cause hunting.
When using a CS-Mount lens
1. Take off the lens protection cap and
attach the C-mount adaptor.
2. Attach the C-Mount lens to the
camera by screwing it in clockwise.
When using a C-Mount lens
Connect the video output terminal located on the back of the camera to
the monitor.
■
Connecting to a monitor
Check the standard power requirement before connecting to power.
■
Connecting to power
DC power adapter (DC12V,1A↑)
VIDEO
RELAY
RS485
SENSOR
POWER
RESET
DC 12V IN
MIC
LAN
SPEAKER
DC 12V IN
WAN
Network Switch
VIDEO
RELAY
RS485
SENSOR
POWER
RESET
DC 12V IN
MIC
LAN
SPEAKER
IP Camera
PC

1. Settings for analog part of the camera can be configured. Camera-specific
menu is displayed using OSD on video display, and this menu can be
operated with 5 buttons on the page.
• Web View page → Setup → Camera
H.264 IP Camera Cywatch H.264 IP Camera Cywatch
16
17
How to Set up the FunctionsFunction Menu Structure
■How to Use the Camera
2. Select a menu item from the list available by using the UP and DOWN
buttons.
•
The cursor can be moved up or down by using the UP and DOWN
buttons. Position the cursor to point to the function requiring adjsutment.
SETUP menu
LENS (selection)
SHUTTER
(condition and speed control)
WHITE BALANCE control
BACKLIGHT
(Backlight Compensation)
AGC (Auto Gain Control)
DNR
(Digital Noise Reduction)
SENS-UP (Low illuminance)
CAM ID
SPECIAL
EXIT
•
MANUAL
•
DC
•
ESC
•
MANUAL
•
FLK
•
ATW
•
AWC
•
MANUAL
•
OFF
•
LOW
•
MIDDLE
•
HIGH
•
OFF
•
LOW
•
MIDDLE
•
HIGH
•
OFF
•
LOW
•
MIDDLE
•
HIGH
•
OFF
•
AUTO
• 0~255
•
CAMERA TITLE
•
COLOR
•
DZOOM
•
SYNC
•
MOTION DET
•
PRIVACY
•
MIRROR
•
SHARPNESS
•
RESET
•
RETURN
Modes can be changed
using the LEFT and
RIGHT buttons.
Select any function you
wish to operate by
using the UP and
DOWN buttons.

●DC/Video : Select Auto Iris Lens
•When DC is selected, you can control screen brightness. The range
of brightness control is between 1 and 70 (40 in case of WDR mode).
Adjust the brightness appropriately for optimal screen brightness.
●
Manual : Select Manual Lens
Note
•Some lenses may not work properly, depending on the setting of the
BRIGHTNESS LEVEL.
•When Using a Video-Type Auto Iris Lens
①Adjust the ALC adjustment terminal on the lens appropriately. In
general, set it to AV (Average).
②It may not work properly depending on the installed lens. Set the
Level VR of the lens to the optimal value.
③Set AGC / SENS-UP to OFF and adjust the Lens VR to an
appropriate brightness.
④Adjust the Lens VR, adjust the BRIGHTNESS, and then check if
the screen brightness changes properly. Otherwise, adjust the Lens
VR again.
■How to Use the Camera
H.264 IP Camera Cywatch H.264 IP Camera Cywatch
18
19
Using this function, you can control screen brightness.
1. When the SETUP menu screen is displayed, select LENS by using the Up
and Down buttons so that the arrow indicates LENS .
2. Select the connected lens type by using the Left and Right buttons.
LENS
3. Set up a selected item by using the Left and Right buttons.
4. To finish the setting, select 'EXIT' and press the SET button.
Note
•An item with the icon also has sub menus. To select a sub menu,
select an item with the icon and press the SET button.
• An item with the - - - icon is unavailable due to function settings.

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
20
21
■How to Use the Camera
Auto or manual control can be selected.
1. When the SETUP menu is on the screen, position the cursor to point to
'SHUTTER' by using the UP and DOWN buttons.
2. Select the shutter mode by pressing the LEFT or RIGHT button.
●FLK : Select 'FLK' mode when flickering occurs on the screen
due to an imbalance between illumination and frequency.
NTSC Model:1/100, PAL Model: 1/120
●ESC : Auto control of the shutter speed is enabled.
When ESC mode is on, the shutter speed is controlled automatically
according to the brightness of the scene.
●MANUAL: The shutter speed can be controlled manually.
3. Select 'MANUAL' mode for manual shutter speed adjustment.
ㆍ
Selectable speeds are from '1/60' to '1/120,000'sec (NTSC) and '1/50'
to '1/120,000'sec (PAL).
4. Press the SETUP button when the settings are completed.
ㆍWhile using the internal synchronous system, if the shutter setting is on
'ESC' and the camera is directly facing bright fluorescent lights the
image on the screen can be adversely affected - therefore choose
the installation location carefully.
ㆍWhen 'MANUAL' mode is on, the SENS UP function cannot be used.
Note
The screen colours can be adjusted using the WHITE BALANCE function.
1. Position the cursor to point to 'WHITE BAL' on the SETUP menu by using the
SHUTTER (condition and speed control)
UP and DOWN buttons.
2. Select the mode you wish to adjust by pressing the LEFT or RIGHT buttons.
※Select one of the 3 modes below.
●
ATW(Auto Tracking White Balance) : This mode can be used within the color
temperature range 1,800˚K ~ 10,500˚K (eg, fluorescent light, outdoor, sodium
vapour lamp etc.)
●
AWC(Auto White Balance Control) : Press the SETUP button while the
camera is directed at a piece of white paper to obtain the optimum state under
current illumination. If the environment, including the light source, changes the
white balance will need to be adjusted again.
●
MANUAL : The manual adjustment mode enables finer adjustment.
Select ATW or AWC first then change to manual adjustment mode and press
the SETUP button. Set the appropriate colour temperature then increase /
decrease the red and blue colour values and monitor the color changes of the
object.
ㆍUnder the following conditions the WHITE BALANCE function may not operate
properly. In such cases, please select the AWC mode.
①
When the object's surroundings have a very high colour temperature
(eg, a clear sky and sunset)
②
When the object's surroundings are dark
③
If the camera directly faces a fluorescent light or is installed in a place where
there are considerable changes in illumination, the WHITE BALANCE
function may become unstable.
Note
WHITE BALANCE

BLC (Back Light Compensation) AGC (Automatic Gain Control)
H.264 IP Camera Cywatch H.264 IP Camera Cywatch
22
23
■How to Use the Camera
1.
Position the cursor to point to 'AGC' on the SETUP menu by using the
UP and DOWN buttons.
2.
Select the value required by pressing the LEFT or RIGHT button. As the
level of gain increases the screen gets brighter but the level of noise will
also increase.
●HIGH
: The gain varies between the range of 6dB ~ 42dB.
●MIDDLE
: The gain varies between the range of 6dB ~ 30dB.
●LOW
: The gain varies between the range of 6dB ~ 18dB.
●OFF
: The gain is fixed at 6dB.
When there is a strong backlight behind the object, clear images of the
background as well as the object can still be obtained by using the
BACKLIGHT function.
1. Position the cursor to point to 'BACKLIGHT' on the SETUP menu by using
the UP and DOWN buttons.
2. Select the value required by pressing the LEFT or RIGHT button.
●HIGH : The gain increases from 0dB up to 42dB.
●
MIDDLE
: The gain increases from 0dB up to 30dB.
●LOW : The gain increases from 0dB up to 18dB.
●OFF : BACKLIGHT function does not operate.

DNR (Digital Noise Reduction)
SENS UP (Low illuminance)
H.264 IP Camera Cywatch H.264 IP Camera Cywatch
24
25
■How to Use the Camera
The level of background noise in low light decreases automatically as the
level of gain changes.
1. Position the cursor to point to 'DNR' on the SETUP menu by using the
UP and DOWN buttons.
2. Select the value required by pressing the LEFT or RIGHT button.
●OFF : There is no reduction in noise level.
●LOW : There is a small reduction in noise level with almost no
ghost image.
●MIDDLE: The most effective mode. There is a sufficient reduction in
noise levels without causing significant ghosting.
●HIGH : The level of noise is reduced greatly, however there is an
increase in ghosting.
SENS UP helps maintain a bright, clear screen image by automatically
detecting changes in the level of light in low light level conditions.
ㆍWhen AGC is turned off, DNR does not operate.
Note
1. Position the arrow to point to 'SENS UP' on the SETUP menu by using
the UP and DOWN buttons.
2. Select the value required by pressing the LEFT or RIGHT button.
●AUTO : Low light level automatic mode.
●OFF : The function does not operate.
3. Press the SETUP button when all the settings are complete.
ㆍWhen SHUTTER is in the manual or flk mode, SENS UP does not operate.
ㆍWhen AGC is turned off, SENS UP does not operate.
Note
ㆍThe maximum storage magnification in low light level movement situations
can be adjusted by pressing the SETUP button in 'AUTO' mode.(X2~X128)
ㆍAs the magnification increases the screen gets brighter; however the after
image also increases.
ㆍIf storage magnification is increased while SENS UP is operational, it may
cause noise and spots may appear; this is normal.
Note

CAM ID SPECIAL
H.264 IP Camera Cywatch H.264 IP Camera Cywatch
26
27
■How to Use the Camera
OSD settings of this camera can be remote controlled by RS-485 communication.
- Protocol : Exclusive Protoclo
- Controller : Exclusive Controller(option)
1. Please press the SETUP button
2. Please select the ID of the Camera by pressing the LEFT or RIGHT button
ㆍThe available ID number of the Camera is 0 ~ 255
1. Position the cursor to point to 'SPECIAL' on the SETUP menu by using
the UP and DOWN buttons.
2. Select the mode required by pressing the UP or DOWN button.
●CAMERA TITLE : If an TITLE is input, this camera TITLE appears on
the monitor and recorded footage.
1) Position the cursor to point to 'CAMERA TITLE' by using the
UP or DOWN button.
2) Select 'ON' by pressing the LEFT or RIGHT button.
ㆍIf 'OFF' is selected, the TITLE does
not appear on the monitor even if it
has been input.
Note

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
28
29
■How to Use the Camera
ㆍIf the wrong name has been input.....
Press the SET button after moving the cursor to CLR and all the letters will be
erased. If you want to correct a letter move the cursor to the arrow at the bottom
left of the screen and press 'SET'.
Position the cursor above the letter you wish to correct and then move the cursor
onto the letter you wish to choose and press the SET button.
Note
3) Press the SET button.
4) Up to 15 characters can be used for the camera TITLE.
①Move the cursor to the letter required by using the UP and DOWN button.
②Select an TITLE from A,B~Y,Z, a,b~y,z, 0,1~8,9 by using the UP,
DOWN, LEFT and RIGHT buttons.
③Lock in the characters by using the SET button.
ㆍOnce locked in the cursor moves to the next space in the TITLE.
④Repeat the above steps until the TITLE is complete.
5) When the camera TITLE is complete, select a position for the name to be
displayed.
①Move the cursor onto 'POS' and then press the SET button.
②The TITLE will appear in the top left
corner.
③Select the position where the TITLE is
to be displayed by using the 4 directional
buttons, and then press the SET button.
6)
Select 'END' and press the SET button to complete
TITLE
input.

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
30
31
■How to Use the Camera
●COLOR
- AUTO : This camera has an IR Cut Filter and automatically changes
to the appropriate mode dependant on lighting levels.
COLOR mode is selected during daylight and B/W mode at
night time.
- ON : The color mode is selected by default, and the modes do not
change automatically.
- BW : The black&white mode is selected by default, and the modes
do not change automatically.
●DZOOM : This camera has a 8x digital zoom function.
Digital zoom just enlarges a portion of the image.
In so doing, it sacrifices the quality of image.
- OFF : Cancels the DZOOM mode.
- ON : Operate the DZOOM mode.
ㆍ
Please press the SET button
ㆍ
The available range of level is 10(X1,0) ~ 80(X8.0)
ㆍWhen the AGC is turned off, COLOR does not operate.
ㆍWhen an infrared light is used, there may be a problem with focusing.
Note
●
SYNC : Two sychronisation modes are available, INTERNAL and
EXTERNAL LINE-LOCK. In LINE-LOCK mode, it synchronises the
video signal between cameras without a synchronous generator.
The line-lock synchronisation is only used in areas of 60Hz
(NTSC Models) / 50Hz (PAL Models).
- INT : Internal synchronisation
- LL : External line-lock synchronisation
ㆍIf 'LL' is selected, it can be adjusted to the desired phase.
Press the SET button.
ㆍAdjust to the desired phase from 0 to 359.
ㆍ
When the mains frequency is 50Hz, the line-lock mode (NTSC Models) cannot be used.
ㆍ
When the mains frequency is 60Hz, the line-lock mode (PAL Models) cannot be used.
Note

H.264 IP Camera Cywatch H.264 IP Camera Cywatch
32
33
■How to Use the Camera
●MOTION DETECTION:
This product has a feature that allows you to observe movements of objects
in 4 different areas on the screen, and the words 'MOTION DETECTED'
appear on the screen when movement is detected; hence a single individual
can conduct supervision efficiently. The camera detects an object's
movement by sensing disparity of outline, and level of brightness and color.
ㆍPlease press the SET button.
- OFF : MOTION DETECTION mode is cancelled.
- ON : Any motion in the selected areas is observed.
ㆍPlease select the area you wish to observe from the 4 areas in AREA
SEL mode.
ㆍPlease select ON mode for the chosen area.
ㆍPlease adjust the size of the area to be observed by using the UP,
DOWN, LEFT or RIGHT button.
ㆍPlease press the SET button to save the changes and complete the setting.
●
PRIVACY :This mode conceals the areas you do not wish to appear on the screen.
- OFF : Cancels the PRIVACY mode. - ON : Operates the PRIVACY mode.
ㆍPlease press the SET button.
ㆍPlease select the area you do not wish to appear from the 4 areas in
AREA SEL mode.
ㆍPlease select ON mode for the chosen area.
ㆍPlease adjust the size of the area to be concealed by using the UP, DOWN,
LEFT or RIGHT button.
●MIRROR
- ON : Sets a horizontal image inversion.
- OFF : Cancels the inversion.
●SHARPNESS :The outline of the video image becomes cleaner and
more distinctive as the level of SHARPNESS increases. If the level goes
up excessively, however, it may affect the video image and generate noise.
ㆍPlease press the SET button.
ㆍThe available range of level is 0 ~ 31.
●RESET :Returns to the level which was set by the manufacturer for shipment.
●RETURN :Saves the SPECIAL menu and returns to the SETUP menu.
Saves all the setting menus and then exits.
EXIT

NETWORK
Interface Ethernet 10/100 Base-T
Connector RJ-45
Protocols TCP/IP, UDP, Multicast, DHCP, PPPoE, SMTP, HTTP, SNMP
VIDEO
Output 1 Composite (1 Vpp 75 Ohm, BNC)
Compression H.264
Resolutions NTSC : 720x480, 720x240, 352x480, 352x240
PAL : 720x576, 720x288, 352x576, 352x288
Frame rate NTSC : Max 30fps, PAL : Max 25fps
Frame Rate Range NTSC : 0.2~30fps, PAL : 0.2~25fps
Bandwidth Configurable between 32 kbps and 4 Mbps
AUDIO
Input 1 Line-in (Mini-stereo)
Output 1 Line-in (Mini-stereo)
Standards G.711
Data rate 32Kbps ~ 128Kbps
CONNECTORS
RS-485 1 port
Sensor 1 port
Relay 1 port
MANAGEMENT S/W
Web viewer and 16ch viewer free, 36 ch viewer optional
OPTIONS PoE
H.264 IP Camera Cywatch H.264 IP Camera Cywatch
34
35
■Troubleshooting
If there are problems with the camera operation, check the tables below. If
the problem persists, please contact the agent who supplied the product.
Problems
Nothing appears on the
screen.
The video image is not
clear.
There is a problem with
the camera operation.
The camera surface is
too hot and black stripes
appear on the screen.
ㆍCheck the power connection.
ㆍCheck the LAN Cable.
ㆍMake sure that the lens is clean.
Clean the lens with a clean lint free cloth or
brush.
ㆍMake sure that the screen is not exposed
directly to a bright light.
Re-position the camera if necessary.
ㆍCheck if an appropriate power source to
the camera complies with the manufacturer's
standard requirement, or if the voltage is
fluctuating. Check for ground loops.
Troubleshooting
The MOTION
DETECTION function is
not working.
Colors are not quite
The image on the
screen is black
ㆍCheck the video format of the your camera
(NTSC / PAL)
right.
COLOR mode is not
working.
ㆍCheck that motion detection of setup on the
web view is 'OFF'
ㆍCheck the 'WHITE BAL' setting.
ㆍCheck if the AGC menu is set to the OFF
position.
SENS-UP function is not
working.
ㆍCheck if the AGC menu is set to the OFF
position.
ㆍCheck if the SHUTTER menu is set to
MANUAL mode.
Specification
■

H.264 IP Camera Cywatch
36
■Specification
CAMERA
Effective Pixels 380K(NTSC), 440K(PAL)
Resolution 540TVL
Min. Illumination Color - 0.3Lux, B/W - 0.002Lux (Sense-up) at F1.2
Shutter Speeds 1/60(N) or 1/50(P) ~ 1/120,000sec.
S/N Ratio More than 50dB (AGC off)
OSD Functions
Main Mode Lens (Manual, DC/Video) , Shutter, White Balance,
BLC, AGC, DNR, Sense-Up (Auto 2X~128X,Off)
Special Mode Camera ID, Color(On, Auto), SYNC, Sharpness(0~31),
Privacy & Motion Detection(4 Programmable Zone),
Mirror, D.Zoom
POWER
Supply voltage 12V DC +/- 10%
Consumption Max. 5W
PHYSICAL
Lens Mount CS mount
Size 63(W) X 145(D) X 53(H)mm
Weight about 0.4Kg (without Lens)
Environmental 0˚C to 50˚C (32˚F to 122˚F)
Humidity 95% non condensing at 50˚C (122˚F)
RECOMMENDED LENSES (NOT INCLUDED)
Any good quality C (with adaptor) or CS mount 1/3 inch format, manual or
DC auto iris lens